L-84-190, Informs That 840330 Submittal Incorrectly Identified 840801 as Effective Date for Revised Inservice Insp & Testing Program for Pumps & Valves.Date Should Be 840930.Pages Reflecting Correct Effective Date Encl

From kanterella
(Redirected from L-84-190)
Jump to navigation Jump to search
Informs That 840330 Submittal Incorrectly Identified 840801 as Effective Date for Revised Inservice Insp & Testing Program for Pumps & Valves.Date Should Be 840930.Pages Reflecting Correct Effective Date Encl
ML17346A436
Person / Time
Site: Turkey Point  
Issue date: 07/26/1984
From: Williams J
FLORIDA POWER & LIGHT CO.
To: Eisenhut D
Office of Nuclear Reactor Regulation
References
L-84-190, NUDOCS 8407310122
Download: ML17346A436 (8)


Text

P OX 14000, JUNO BEACH, FL 33408

~~y)lfjir~

+/I]i<A+

FLORIDA POWER. & LIGHT COMPANY July 26, 1984 L-84-190 Office of Nuclear Reactor Regulation Attention:

Mr. Darrell G. Eisenhut, Director Division of Licensing U.S. Nuclear Regulatory Commission Washi ngton, D.C.

20555

Dear Mr. Eisenhut:

Re'.

Turkey Point Units 3 and 4

Docket Nos. 50-250 and 50-251 Revisions to Inservice Test Progr an for Pumps and Valves In the Abstracts for the Turkey Point Units 3 and 4 Valve Test Progr aII and Pump Test Program submitted with our letter, L-84-84, dated March 30,

1984, we inadvertently identified the effective date of the revised prograIIs as August 1, 1984.

It had been our intention to make the progran effective six months after the submittal date as we did with the submittal for St. Lucie Unit 1.

Our draft of the report had set the 6 month date as, August 1, 1984 and this date was not corrected in our final letter.

To correct the effective date discussed

above, we have attached revised abstract pages for the IST program which set the effective date as six months after the submittal of the progr an.

For the current submittal, the effective date wil.l therefore be September 30, 1984.

l<e have also attached page 119 of the submittal.

This page m@

have been inadvertently omitted from some copies of the program.

Should you or your staff have any questions on this information, please contact us.

Very truly yours, ggd~~u>

J.W. Willians, Jr.

Group Vice President Nuclear Energy JWW/PLP/djc Attachment CC:

Mr. Janes P. O'Reilly, Region II Harold F. Reis, Esqu1r e PNS-L I-84-259 8407310122 840726'DR ADOCK 05000250 6

PDR PEOPLE... SERVING PEOPLE

0

TURKEY POINT UNIT 3 ABSTRACT The, planned inservice inspection and testing programs were developed employing the R.G. 1.26, Revision 2, criteria for quality group classifications and standards (Quality Group A is the same as ASME Class 1, etc.).

Section I.

Valve Test Procrram Outline The valve test program shall be conducted in accordance with Subsection IWV of Section XI of the 1980 Edition of the ASME Boiler and Pressure Vessel Code thru Winter 198l Addenda, except for specific relief requested in accordance with 10 CFR 50.55a (g) (5) (iii) which is identified in Subsections I.G.

The period for this valve test program starts December 14, 1982, and ends December 14,.1992.

The effective date of this revised valve test program shall be six (6) months after the submittal date.

Section II.

~Pum Test Procrram Outline The pump test, program shall be conducted in accordance with Subsection IWP of Section XI of the 1980 Edi'tion of the ASME

Boiler and Pressure Vessel Code thru: Winter 1981 Addenda, except for specific relief.requested in accordance with 10 CPR 50.55a (g) (5) (iii) which is identified in Subsection II.A.

The period for the pump test program starts. December 14,

1982, and ends December 14, 1992.

The effective date of this revised pump test program shall be six (6) months after the submittal date.

ik r

l P

f

TURREY POINT UNIT 4 ABSTRACT The planned inservice inspection and testing programs, were developed employing the R.G. 1.26, Revision 2, criteria for quality group classifications and standards.

(Quality Group A is the same as ASME Class 1, etc.).

'Section E.

Valve Test Procrram Outline The valve test program shall be conducted in accordance with Subsection IWV of Section XI of the 1980 Edition of the ASME Boiler and Pressure Vessel Code thru Winter 1981 Addenda, except for. specific relief requested in.accordance with 10 CFR 50.55a (g) (5) (iii) which. is identified in Subsections I.G.

The.period for this valve test program starts September 7, 1983, and ends September 7, 1993.

The effective date of this revised'alve test program shall be six (6) months after the submittal date.

Section ZZ.

~pum Test procrram Outline The pump test program shall 'be conducted in accordance with J

Subsection IWP of Section XI of the 1980. Edition of the ASME Boiler and Pressure Vessel Code thru Winter 1981 Addenda, except for specific relief requested in accordance with 10 CPR 50.55a (g) (5).(iii) which is identified in Subsection II.A.

The period for the pump test program starts September 7, 1983, and ends September 7, 1993.

The effective date of this revised pump test program ashall be six (6) months after the submittal date.

0 r

TURKEY POINT UNIT NO.

3

& 4 PAGE 1

OF 2

FLORIDA POWER

& LIGHT COMPANY TABLE IV PUMP TEST PROGRAM PUMP PUMP NO.

Speed, H

Inlet Pressure TEST PARAMETERS Dxfferentxal Pressure DELTA P Plow Rate

()

V bratxon Bearing RRB Amplitude, Temperature NO.

V Tb(>>

Auxiliary Feed P2A P2B P2C Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes"'es"'es"'es Yes Yes Yes Yes Yes Intake Cooling Water

  • -P9A
  • -P98
  • -P9C Yes Yes Yes Yes Yes Yes Yes"'es"'es(3)

Yes Yes Yes No Residual Heat Removal

  • -P210A

<<-P210B Yes Yes Yes Yes No

"'o"'es Yes 1&3 1&3 Component Cooling

  • -P211A

<<'>>'P211B

  • -P211C Yes Yes Yes Yes Yes Yes Yes"'es'(3)

Yes Yes Yes Yes Yes Yes Yes Containment Spray

  • -P214A
  • -P214B Yes Yes Yes Yes No

"'o (2)

Yes Yes Yes Yes

-119-

0 0

~ 7 J

I 1

f