L-82-326, Forwards Info in Response to IE Bulletin 82-02, Degradation of Threaded Fasteners in RCPB of PWR Plants. Control Rod Drive Flanges Have Omega Seal Weld Design.No Injection Sealant Matl Used
| ML20062J117 | |
| Person / Time | |
|---|---|
| Site: | Turkey Point |
| Issue date: | 08/02/1982 |
| From: | Robert E. Uhrig FLORIDA POWER & LIGHT CO. |
| To: | James O'Reilly NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| References | |
| REF-SSINS-6820 IEB-82-02, IEB-82-2, L-82-326, NUDOCS 8208160267 | |
| Download: ML20062J117 (3) | |
Text
.
P O. BO x 14000, JUNO GE ACH, F L 33agg W
5
,yl FLORIDA POWER & LIGHT eOMPANY
~
August 2, 1982 L-82-326 Mr. James P. O'Reilly Regional Administrator, Region II U. S. Nuclear Regulatory Commission 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303
Dear Mr. O'Reilly:
Reference:
Turkey Point Units 3 & 4 Docket Nos. 50-250, 50-251 IE Bulletin 82-02 Florida Power & Light has reviewed IE Bulletin 82-02 (Degradation of Threaded Fasteners in the Reactor Coolant Pressure Boundary of PWR Plants) as. it pertains to Turkey Point Units 3 & 4.
In response to Action Item 3 of the subject bulletin, we have 1) identified the bolted closures of the Reactor Coolant Pressure Boundary (RCPB) having a nominal diameter of 6 inches or greater as dictated by the scope of this bulletin; 2) identified those bolted closures of the RCPB that have experienced leakage during the most recent plant operating cycle; and
- 3) identified those closures where fastener lubricants have been or are being used including types of lubricants.
Table 1 is a summary of the above information.
Please note that our control rod drive flanges have an omega seal weld design and thus are excluded from this bulletin action. The type and manufacturer names of lubricants associated with each item are listed in Table 1.
Never Sieze is a nickel powder in a mineral oil carrier. Molykote Z is made up primarily of molybdenum disulfide.
Neolube consists of colloidal graphite in isopropanol.
Fel-Pro N-5000 is a proprietary nickel graphite mixture.
Injection sealant materials are not used on reactor coolant pressure boundary bolted closures at Turkey Point.
Fifty-four manhours were required to review he Bulletin and to prepare this portion of the response.
Very truly yours,
&bN y
Robert E. Uhrig Vice President Advanced Systems & Technology REU/PLP/ cab cc: Harold Reis, Esquire Attachment 8208160267 820802 ggfI es PDR ADOCK 05000250 G
PDR PEOPLE.. SERVING PEOPLE
-TABLE 1
SUMMARY
OF BOLTED CLOSURES OF THE RCPB AS Y
DESCRIBED IN THE SCOPE OF IE BULLETIN 82-02 EXPERIENCED LEAKAGE BOLTED CLOSURE IN RCPB DURING RECENT CYCLE
- CORRECTIVE ACTION FASTENER LUBRICANT USED Unit 3 Unit 4 Unit 3 Unit 4 RHR lsolation Valve Studs MOV-750 No Leakage No Leakage N/A N/A Nuclear Grade Never Seize /
(Loop C hot leg to RHR system gate Fel-Pro-N-5000 valve)
Reactor Coolant Pump Closure Studs No Leakage No Leakage N/A N/A Nuclear Grade Never Seize /
Fel-Pro-N-5000 Safety Injection Check Valve Studs Valve 375A (SI to loop A cold leg)
No Leakage No Leakage N/A N/A Huron Industries Incorporated's Neolube/Fel-Pro-N-5000 Valve 875B (SI to loop B cold leg)
No Leakage No Leakage N/A N/A Huron Industries Incorporated's Neolube/Fel-Pro-N-5000 Valve 875C (SI to loop C cold leg)
No Leakage No Leakage N/A N/A Huron Industries Incorporated's Neolube/Fel-Pro-N-5000 Reactor Vessel Head Closure Studs No Leakege No Leakage N/A N/A Dow-Corning's Molykote Z Pressurizer Manway Closure Studs No Leakage No Leakage N/A N/A Nuclear Grade Never Seize Primary Steam Generator Manway Closure Studs Loop A Hot Leg No Leakage Gasket Leak N/A Gaskets and Nuclear Grade Never Seize /
Loop A Cold Leg No Leakage Gasket Leak N/A 2 galled bolts Fel-Pro-N-5000 replaced on 2/6/82 Loop B Hot Leg No Leakage Gasket Leak N/A Gaskets replaced Nuclear Grade Never Seize /
Loop B Cold Leg No Leakage Gr_sket Leak N/A on 2/4/82 Fel-Pro-N-5C00 Loop C Hot Leg No Leakage Gasket Leak N/A Gaskets and Nuclear Grade Never Seize /
Loop C Cold Leg No Leakage Gasket Leak N/A 1 galled bolt Fel-Pro-N-5000 replaced on 2/4/82
- Unit 3: Present operating cycle (April,1982 to present)
Unit 4: Present operating cycle (October,1981 to present)
Vt L
STATE OF FLORIDA
)
)
ss.
COUNTY OF DADE
)
J. A. Deltastry
, being first duly sworn, deposes and says:
j That he is Manager, Nuclear Licensing of Florida Power &
Light Company, the herein; That he has executed the foregoing document; that the state-ments made in this said document are true and correct to the best of his knowledge, information,-and belief, and that he is authorized to execute the document on behalf of said mmh k
J.A.DeMastr[
i Subscribed and sworn to before me this M
day of b j_c d 19 B4 g
1 5.
/LL4LM L NOTARY PUBLIC, i @ nd for the County of Dade, State of Florida tsec.,y Pde Et?.ts cf Persia et Lvge th C a n c,c, Ex p e Octe er 30, 11 0 My Commission expires: ew i ti.re *4yr.srd Bcad ng Agency 6
6
?
i g
.m..
.y
-we e
m
-