L-2022-125, Cycle 31 Core Operating Limits Report

From kanterella
(Redirected from L-2022-125)
Jump to navigation Jump to search
Cycle 31 Core Operating Limits Report
ML22249A008
Person / Time
Site: Saint Lucie 
Issue date: 09/06/2022
From: Strand D
Florida Power & Light Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-2022-125
Download: ML22249A008 (15)


Text

U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-00001 Re:

St. Lucie Nuclear Plant, Unit 1 Docket 50-335 Cycle 31 Core Operating Limits Report L-2022-125 10 CFR 50.36 Pursuant to St. Lucie Unit 1 Technical Specification (TS) 6.9.1.11.d, Florida Power & Light Company (FPL) is submitting the Core Operating Limits Report (COLR) for operating cycle 31.

Should there be any questions concerning this submittal, please contact Timothy Falkiewicz at (772) 429-3756.

Sincerely, Dianne Strand General Manager Regulatory Affairs Enclosure cc:

USNRC Regional Administrator, Region II USNRC Project Manager, St. Lucie Nuclear Plant USNRC Resident Inspector, St. Lucie Nuclear Plant Florida Power & Light Company 6501 S. Ocean Drive, Jensen Beach, FL 34957

Verified by:

EC 297378, Rev. 0, Page' 1 of 14 ST. LUCIE UNIT 1, CYCLE 31 CORE OPERATING LIMITS REPORT Revision 0 or;, /14-/z.o zz_

Date R. Hunter Date

~..1aJ-'

Approved by:

6/14/2022

. N. Kabadi Date

EC 297378, Rev. 0, Page 2 of 14 St. Lucie Unit 1 CYCLE 31 COLR Rev. 0 Page 2 of 14 Table of Contents Description Page 1.0 Introduction 3

2.0 Core Operating Limits 2.1 Moderator Temperature Coefficient 4

2.2 Full Length CEA Position - Misalignment > 15 inches 4

2.3 Regulating CEA Insertion Limits 4

2.4 Linear Heat Rate 4

2.5 TOTAL INTEGRATED RADIAL PEAKING FACTOR 5

2.6 DNB Parameters 5

2.7 Refueling Operations - Boron Concentration 5

2.8 SHUTDOWN MARGIN - Tavg Greater Than 200 0F 5

2.9 SHUTDOWN MARGIN - Tavg Less Than or Equal To 200 0F 5

3.0 List of Approved Methods 13 List of Figures Figure Title Page 3.1-1a Allowable Time To Realign CEA vs. Initial FrT 7

3.1-2 CEA Insertion Limits vs. THERMAL POWER 8

3.2-1 Allowable Peak Linear Heat Rate vs. Burnup 9

3.2-2 AXIAL SHAPE INDEX vs. Maximum Allowable Power Level 10 3.2-3 Allowable Combinations of THERMAL POWER and FrT 11 3.2-4 AXIAL SHAPE INDEX Operating Limits vs. THERMAL POWER 12 List of Tables Table Title Page 3.2-1 DNB Margin Limits 6

EC 297378, Rev. 0, Page 3 of 14 St. Lucie Unit 1 CYCLE 31 COLR Rev. 0 Page 3 of 14

1.0 INTRODUCTION

This CORE OPERATING LIMITS REPORT (COLR) describes the cycle-specific parameter limits for the operation of St. Lucie Unit 1. It contains the limits for the following, as provided in Section 2.0:

Moderator Temperature Coefficient Full Length CEA Position - Misalignment > 15 Inches Regulating CEA Insertion Limits Linear Heat Rate TOTAL INTEGRATED RADIAL PEAKING FACTOR - FrT DNB Parameters Refueling Operations - Boron Concentration SHUTDOWN MARGIN - Tavg Greater Than 200 0F SHUTDOWN MARGIN - Tavg Less Than or Equal To 200 0F This report also contains the necessary tables and figures which give the limits for the above listed parameters.

Terms appearing in capitalized type are DEFINED TERMS as defined in Section 1.0 of the Technical Specifications.

This report is prepared in accordance with the requirements of Technical Specification 6.9.1.11.

EC 297378, Rev. 0, Page 4 of 14 St. Lucie Unit 1 CYCLE 31 COLR Rev. 0 Page 4 of 14 2.0 CORE OPERATING LIMITS 2.1 Moderator Temperature Coefficient (TS 3.1.1.4)

The moderator temperature coefficient (MTC) shall be less negative than -32 pcm/0F at RATED THERMAL POWER.

2.2 Full Length CEA Position - Misalignment > 15 Inches (TS 3.1.3.1)

The time constraints for full power operation with the misalignment of one full length CEA by 15 or more inches from any other CEA in its group are shown in Figure 3.1-1a.

2.3 Regulating CEA Insertion Limits (TS 3.1.3.6)

The regulating CEA groups shall be limited to the withdrawal sequence and to the insertion limits shown on Figure 3.1-2, with CEA insertion between the Long Term Steady State Insertion Limits and the Power Dependent Insertion Limits restricted to:

a.

< 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> per 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> interval, b.

< 5 Effective Full Power Days per 30 Effective Full Power Day interval, and c.

< 14 Effective Full Power Days per calendar year.

2.4 Linear Heat Rate (TS 3.2.1)

The linear heat rate shall not exceed the limits shown on Figure 3.2-1.

The AXIAL SHAPE INDEX power dependent control limits are shown on Figure 3.2-

2.

During operation, with the linear heat rate being monitored by the Excore Detector Monitoring System, the AXIAL SHAPE INDEX shall be maintained within the limits of Figure 3.2-2.

During operation, with the linear heat rate being monitored by the Incore Detector Monitoring System, the Local Power Density alarm setpoints shall be adjusted to less than or equal to the limits shown on Figure 3.2-1.

EC 297378, Rev. 0, Page 5 of 14 St. Lucie Unit 1 CYCLE 31 COLR Rev. 0 Page 5 of 14 2.5 TOTAL INTEGRATED RADIAL PEAKING FACTOR - FrT (TS 3.2.3)

The calculated value of FrT shall be limited to < 1.65 The power dependent FrT limits are shown on Figure 3.2-3.

2.6 DNB Parameters (TS 3.2.5)

The following DNB-related parameters shall be maintained within the limits shown on Table 3.2-1:

a.

Cold Leg Temperature

b.

Pressurizer Pressure

c.

AXIAL SHAPE INDEX 2.7 Refueling Operations - Boron Concentration (TS 3.9.1)

With the reactor vessel head unbolted or removed, the boron concentration of all filled portions of the Reactor Coolant System and the refueling cavity shall be maintained uniform and sufficient to ensure that the more restrictive of the following reactivity conditions is met:

a.

Either a Keff of 0.95 or less, which includes a 1000 pcm conservative allowance for uncertainties, or

b.

A boron concentration of > 1900 ppm, which includes a 50 ppm conservative allowance for uncertainties.

2.8 SHUTDOWN MARGIN - Tavg Greater Than 200 0F (TS 3.1.1.1)

The SHUTDOWN MARGIN shall be greater than or equal to 3600 pcm.

2.9 SHUTDOWN MARGIN - Tavg Less Than or Equal To 200 0F (TS 3.1.1.2)

The SHUTDOWN MARGIN shall be greater than or equal to 2000 pcm.

EC 297378, Rev. 0, Page 6 of 14 St. Lucie Unit 1 CYCLE 31 COLR Rev. 0 Page 6 of 14 Table 3.2-1 DNB MARGIN LIMITS PARAMETER FOUR REACTOR COOLANT PUMPS OPERATING Cold Leg Temperature

< 551oF Pressurizer Pressure*

> 2225 psia AXIAL SHAPE INDEX COLR Figure 3.2-4 Limit not applicable during either a THERMAL POWER ramp increase in excess of 5% per minute of RATED THERMAL POWER or a THERMAL POWER step increase of greater than 10% of RATED THERMAL POWER.

EC 297378, Rev. 0, Page 7 of 14 St. Lucie Unit 1 CYCLE 31 COLR Rev. 0 Page 7 of 14 FIGURE 3.1-1a Allowable Time to Realign CEA vs. Initial FrT 1.55 1.57 1.59 1.61 1.63 1.65 1.67 0

10 20 30 40 50 60 70 Time at Full Power to Realign CEA, Minutes (60, 1.65)

Measured Pre-Misaligned FTr

EC 297378, Rev. 0, Page 8 of 14 St. Lucie Unit 1 CYCLE 31 COLR Rev. 0 Page 8 of 14 7

5 3

GROUPS 137 110 82 55 28 0

137 110 82 55 28 0

137 110 82 55 28 6

4 137 110 82 55 28 0

137 110 82 55 28 0

CEA GROUP POSITION (INCHES WITHDRAWN) 0 SHORT TERM STEADY STATE INSERTION LIMIT LONG TERM STEADY STATE INSERTION LIMIT FRACTION OF RATED THERMAL POWER 1.00 0.90 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0

(Group 7 @ 69 in., 0.75)

(Group 7 @ 55 in., 0.70)

(Group 7 @ 103 in., 1.00)

Group 7 @ 103 in. withdrawn Group 7 @ 28 in. withdrawn (Group 5 @ 55 in., 0.0)

FIGURE 3.1-2 CEA Insertion Limits vs. THERMAL POWER (4 Reactor Coolant Pumps Operating)

EC 297378, Rev. 0, Page 9 of 14 St. Lucie Unit 1 CYCLE 31 COLR Rev. 0 Page 9 of 14 FIGURE 3.2-1 Allowable Peak Linear Heat Rate vs. Burnup 13.0 14.0 15.0 16.0 17.0 Cycle Life UNACCEPTABLE OPERATION ACCEPTABLE OPERATION BO L EO L Allowable Peak Linear Heat Rate, kw/ft

EC 297378, Rev. 0, Page 10 of 14 St. Lucie Unit 1 CYCLE 31 COLR Rev. 0 Page 10 of 14 (Not Applicable Below 40% Power)

Note: AXIAL SHAPE INDEX limits for Linear Heat Rate when using Excore Detector Monitoring System)

FIGURE 3.2-2 AXIAL SHAPE INDEX vs. Maximum Allowable Power Level (0.05,0.85)

(0.5,0.45)

(-0.5,0.45)

(-0.08,0.85)

Region of Acceptable Operation 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10

-0.6

-0.4

-0.2 0.0 0.2 0.4 0.6 Peripheral AXIAL SHAPE INDEX Fraction of Maximum Allowable Power Level Region of Unacceptable Operation

(-0.08,0.78)

(0.05,0.78)

Region of Unacceptable Operation

EC 297378, Rev. 0, Page 11 of 14 St. Lucie Unit 1 CYCLE 31 COLR Rev. 0 Page 11 of 14 FIGURE 3.2-3 Allowable Combinations of THERMAL POWER and FrT

EC 297378, Rev. 0, Page 12 of 14 St. Lucie Unit 1 CYCLE 31 COLR Rev. 0 Page 12 of 14 (Not Applicable Below 40% Power)

(AXIAL SHAPE INDEX limits for DNB)

FIGURE 3.2-4 AXIAL SHAPE INDEX Operating Limits vs. THERMAL POWER (Four Reactor Coolant Pumps Operating)

(0.15,1.0)

(0.5,0.65)

(-0.5,0.65)

(-0.08,1.0)

Region of Acceptable Operation Region of Unacceptable Operation 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10

-0.6

-0.4

-0.2 0.0 0.2 0.4 0.6 Peripheral AXIAL SHAPE INDEX (Y1)

Fraction of RATED THERMAL POWER Region of Unacceptable Operation

EC 297378, Rev. 0, Page 13 of 14 St. Lucie Unit 1 CYCLE 31 COLR Rev. 0 Page 13 of 14 3.0 LIST OF APPROVED METHODS The analytical methods used to determine the core operating limits are those previously approved by the NRC, and are listed below.

1.

WCAP-11596-P-A, "Qualification of the PHOENIX-P/ANC Nuclear Design System for Pressurized Water Reactor Cores," June 1988 (Westinghouse Proprietary).

2.

NF-TR-95-01, "Nuclear Physics Methodology for Reload Design of Turkey Point &

St. Lucie Nuclear Plants," Florida Power & Light Company, January 1995.

3.

XN-75-27(A) and Supplements 1 through 5, [also issued as XN-NF-75-27(A)],

"Exxon Nuclear Neutronic(s) Design Methods for Pressurized Water Reactors,"

Exxon Nuclear Company, Inc. / Advanced Nuclear Fuels Corporation, Report and Supplement 1 dated April 1977, Supplement 2 dated December 1980, Supplement 3 dated September 1981 (P), Supplement 4 dated December 1986 (P), and Supplement 5 dated February 1987 (P).

4.

Deleted.

5.

XN-NF-82-21(P)(A) Revision 1, "Application of Exxon Nuclear Company PWR Thermal Margin Methodology to Mixed Core Configurations," Exxon Nuclear Company, Inc., September 1983.

6.

Deleted.

7.

XN-75-32(P)(A) Supplements 1 through 4, "Computational Procedure for Evaluating Fuel Rod Bowing," Exxon Nuclear Company, Inc., October 1983.

8.

Deleted.

9.

XN-NF-78-44(NP)(A), "A Generic Analysis of the Control Rod Ejection Transient for Pressurized Water Reactors," Exxon Nuclear Company, Inc., October 1983.

10.

XN-NF-621(P)(A) Revision 1, "Exxon Nuclear DNB Correlation for PWR Fuel Designs," Exxon Nuclear Company, Inc., September 1983.

11.

Deleted.

12.

XN-NF-82-06(P)(A) Revision 1, and Supplements 2, 4 and 5, Qualification of Exxon Nuclear Fuel for Extended Burnup, Exxon Nuclear Company, Inc., October 1986.

13.

ANF-88-133(P)(A) and Supplement 1, Qualification of Advanced Nuclear Fuels PWR Design Methodology for Rod Burnups of 62 GWd/MTU, Advanced Nuclear

EC 297378, Rev. 0, Page 14 of 14 St. Lucie Unit 1 CYCLE 31 COLR Rev. 0 Page 14 of 14 Fuels Corporation, December 1991.

14.

XN-NF-85-92(P)(A), Exxon Nuclear Uranium Dioxide/Gadolinia Irradiation Examination and Thermal Conductivity Results, Exxon Nuclear Company, Inc.,

November 1986.

15.

Deleted.

16.

Deleted.

17.

EMF-92-116(P)(A), Revision 0, and Supplement 1(P)(A), Revision 0, Generic Mechanical Design Criteria for PWR Fuel Design, February 1999 and February 2015.

18.

EMF-92-153(P)(A) Revision 1, HTP: Departure from Nucleate Boiling Correlation for High Thermal Performance Fuel, Siemens Power Corporation, January 2005.

19.

EMF-96-029(P)(A) Volumes 1 and 2, Reactor Analysis System for PWRs Volume 1

- Methodology Description, Volume 2 - Benchmarking Results, Siemens Power Corporation, January 1997.

20.

EMF-1961(P)(A), Revision 0, Statistical Setpoint/Transient Methodology for Combustion Engineering Type Reactors, Siemens Power Corporation, July 2000.

21.

EMF-2310(P)(A), SRP Chapter 15 Non-LOCA Methodology for Pressurized Water Reactors, Revision 1, as supplemented by ANP-3000(P), St. Lucie Unit 1 EPU -

Information to Support License Amendment Request, Revision 0.

22.

EMF-2328(P)(A), PWR Small Break LOCA Evaluation Model, S-RELAP5 Based, Revision 0, as supplemented by ANP-3000(P), St. Lucie Unit 1 EPU - Information to Support License Amendment Request, Revision 0.

23.

EMF-2103(P)(A), Realistic Large Break LOCA Methodology for Pressurized Water Reactors, Revision 0, as supplemented by ANP-2903(P), St. Lucie Nuclear Plant Unit 1 EPU Cycle Realistic Large Break LOCA Summary Report with Zr-4 Fuel Cladding, Revision 1.

24.

BAW-10240(P)(A) Revision 0, Incorporation of M5 Properties in Framatome ANP Approved Methods, Framatome ANP, Inc., May 2004.