L-2020-075, Relief Request No. 6 Notification to Withdraw Relief Request for Train a CCW Return Piping

From kanterella
(Redirected from L-2020-075)
Jump to navigation Jump to search

Relief Request No. 6 Notification to Withdraw Relief Request for Train a CCW Return Piping
ML20110A000
Person / Time
Site: Turkey Point NextEra Energy icon.png
Issue date: 04/19/2020
From: Hess R
Florida Power & Light Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-2020-075
Download: ML20110A000 (2)


Text

Florida Power & Light Company 9760 S.W. 344th Street Homestead, FL 33035 April 19, 2020 L-2020-075 10 CFR 50.55a U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555-0001 Re:

Turkey Point Unit 3 Docket Nos. 50-250 Subsequent Renewed License No. DPR-31 Relief Request No. 6 Notification to Withdraw Relief Request for Train A CCW Return Piping

References:

1. Florida Power & Light Company (FPL) letter L-2020-056, Turkey Point Unit 3, Fifth Ten-Year Inservice Inspection Interval Relief Request No. 6, dated March 30, 2020.

NRC's document management system (ADAMS) ML accession number:

ML20090K520

2. Florida Power & Light Company (FPL) letter L-2020-073, Turkey Point Unit 3, Fifth Ten-Year Inservice Inspection Interval Revised Relief Request and Supplemental Information for Train B CCW Return Piping, dated April 13, 2020. NRC's document management system (ADAMS) ML accession numbers: ML20104B999 for the nonproprietary submission and ML20104C000 for the proprietary submission.
3. Electronic Mail, from NRCs Senior Project Manager Turkey Point, Ms. Eva Brown to Mr. Robert Hess Licensing Manager Turkey Point, Titled DRAFT: Turkey Point Unit 3 - Relief Request Concerning CCW Header Weld Repairs (EPID L-2020-LLR-0040),

dated April 14, 2020

4. Florida Power & Light Company (FPL) L-2020-074, Response to Request for Additional Information for Relief Request No. 6, dated April 15, 2020. NRC's document management system (ADAMS) ML accession number: ML20106F200 In Reference 1, FPL requested relief from the applicable American Society of Mechanical EngineersSection XI Code (ASME Code) requirements to repair certain sections of the degraded Unit 3 Component Cooling Water (CCW) supply and return piping by installing a welded proprietary repair device, PMCap Restoration Method - US Patent 6,860,297 without removing the sections of degraded piping.

In Reference 2, FPL submitted the Revised Relief Request No.6 for the Trains A and B return piping, and provided supplemental information for the Train B CCW return piping.