L-2016-044, Inservice Inspection Program Owners Activity Report
| ML16109A158 | |
| Person / Time | |
|---|---|
| Site: | Turkey Point |
| Issue date: | 02/26/2016 |
| From: | Summers T Florida Power & Light Co |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| L-2016-044 | |
| Download: ML16109A158 (7) | |
Text
U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555-00001 Re:
Turkey Point Unit 3 Docket No. 50-250 lnservice Inspection Program Owner's Activity Report (OAR-1)
FEB 2 6 2016 L-2016-044 10 CFR 50.55a Attached find the Owner's Activity Report (Form OAR-1), for Turkey Point Unit 3 Fifth lnservice Inspection Interval, First Period, Second Refueling Outage (PTN 3-28). The Form OAR-1, Owner's Activity Report, implements Code Case N-532-5.
Should there be any questions concerning this report, please contact Mr. Mitch Guth, Licensing Manager, at 305-246-6698.
Sincerely,
~l~...---, -
A~mas Summers Vice President Turkey Point Nuclear Plant SM Attachment Florida Power & Light Company 9760 S.W. 344'" Street Homestead, FL 33035
FORM OAR-'1 OWNER'S ACTMTY REPORT ReportNumb~r. ISl'-PTN3~28,
- p f~nt:
Turkev Point Nuclear Power Plant Unit 3 9760 SW 344th Street Homestead. Florida* 33035 L-2016-044, Attachment Co'r'nrriet'yial Service' Date: December 14. 1972 Refueling Outage No.i PTN 3,...2a Curreritlnsp~ctiof).lnterv'al.: ISi-Fifth. IWE-Secohd CurrenUnspectlori Periqd: ISi Fifth Interval-First Period and IWE Second lnterv'al ""Third' Period.
Ed.i.tio11 and Add~oda of Section XI applicable tq the inspection plans: ISi Fifth lnterval;.zb(ri t=dition.with Addenda through 2b08 and* IWE-2001 with Addenda through 2003; Date and Revision of Inspection Plans: I Si Fifth.Interval Effective-Februarv*2212014:' Rev. o and IWE Second Interval Effective March 3, 2009; Rev,o
. Edition and Aqc;fenda of$~ction XI applJcable tt> repairs and repla~inents, if differentthan the iiJspectlon* plan: ASME Section Xl2oo7 EditioMhrough 2008 Addenda.
Code* ea~es Used: As Referenced in the IS I Program Plan and Schedule
. CERTIFICATE' OF CONFORMANCE I certify that. (a). the* statem,ents *made ih: this report are correct;_ (b) th.e examjn~tions ang tests 111eetthe Inspection plan; as required.by the'.ASfy1J: Cqde *. section XI; ancl (c)_t~e
~epairlr'epl~cemen.t activities and eyalllatfons supporting the completibn of PTN3'-2S conform to. the requirements of *Section Xi.
..£ Date
,4/?z.. /tc.
I Signed.:£; P., <1*~.. P#r /.tu&;Ac.. (._t.c;~... * /'<&if,
- Owner:or Owner's oe*slgne~~-Title' CERTIFICATE' OF INSgRVICE INSPECTIQN I, the* lindersign.ed1 holding a valid commission issued by the National Board *of Boller and Pressure Vessel Inspectors and the Stater or Province of Georgia and employed by the Hartford Steam Boiler lqspection and Insurance Company c;if Connecti94t Jiave iiispe.cfe~ the items ciescribed in this *owner's ActivitY Report, and state that, to th~ Qest of my knowledge and b~lief, the* OV'liner' lias p~iforme9 all activities Jepresent~d by ftiis report in accordance wit_h the reqLiiremeh~s ofSection XI.
Sy signing this. certificate n~ither the Inspector nor his employer makes any warranty; e:>(pre.sseQ Qr implied, -conceming*the repair/replacement activities and evalur~tion described in this report. Furthermore; neither the inspector nor his employer shall be liable in any:.manner for any personalinjury or roperty daltiage or loss of anyJ<irid arising from or connected With this irisp.ection, Date./&~!M:j
L-2016-044, Attachment FORM OAR-1 OWNER'S ACTIVITY REPORT TABLE 1 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Examination Category and Item Description Evaluation Description Item Number NONE NONE NONE 2
L-2016-044, Attachment FORM OAR-1 OWNER'S ACTIVITY REPORT TABLE2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code Class Item Description Date Repair/Replacement Description Of Work Completed Plan Number Snubbers Replace 1,2,3 Various Snubbers and 11/19/2015 RR40351819-01 Load Pins 1
Valve Replace 11/30/2015 RR37020966-01 3-385 1
Valve Replace Bonnet 11/30/2015 RR40160997-01 CV-3-200B Bolting 1
Safety Valve Replace Bonnet 11/30/2015 RR40352529-01 RV-3-551B Nut Support Remove 2
indication from 11/21/2015 RR40425245-01 8080-R-006-01 support 2
Valve Replace Valve 11/30/2015 RR40161364-01 SGWL-3-025 2
Valve Replace bonnet 11/30/2015 RR40272223-26 CV-3-303A bolting 2
Valve Replace bonnet 11/30/2015 RR40355834-26 CV-3-303B bolting 2
Valve Replace bonnet 11/30/2015 RR40355835-26 CV-3-303C bolting 3
L-2016-044, Attachment FORM OAR-1 OWNER'S ACTIVITY REPORT TABLE2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code Class Item Description Date Repair/Replacement Description Of Work Completed Plan Number 2
Relief Valve Replace Flange 11/30/2015 RR40034113-01 RV-3-858B Bolting Piping near Remove tooling 2
Valve 3-293C marks in pipe 11/21/2015 RR40428318-01 2
Piping near Remove Arc 11/21/2015 RR40428320-01 Valve 3-293A Strikes on piping Piping Modify Piping 2
3ARCP during RCP 11/30/2015 RR40272223-21 modification Piping Modify Piping 2
3BRCP during RCP 11/30/2015 RR40355834-18 modification Piping Modify Piping 2
during RCP 11/30/2015 RR40355835-18 3CRCP modification 3
Relief Valve Replace Bolting 12/04/2015 RR404197 44-01 RV-3-1412 3
Relief Valve Replace Valve 11/15/2015 RR40281615-02 RV-3-707 with New 3
Heat Exchanger Retube Heat 2/20/2015 RR40088991-01 3E207A Exchanger 3
Heat Exchanger Retube Heat 03/06/2015 RR40088994-01 3E207B Exchanger 4
L-2016-044, Attachment FORM OAR-1 OWNER'S ACTIVITY REPORT TABLE 2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code Class Item Description Date Repair/Replacement Description Of Work Completed Plan Number 3
Heat Exchanger Retube Heat 2/07/2015 RR40088995-01 3E207C Exchanger 3
Valve Replace Valve 07/10/2015 RR40243391-01 3-50-321 3
Piping Add FLEX-11/26/2014 RR40295266-10 FLEX CST-1 Connection 3
Piping Add FLEX~
9/22/2015 RR40295266-11 FLEX CST-2 Connection 3
Piping Add FLEX-7/2/2015 RR40295266-13 FLEX SFP-1 Connection 3
Piping Add FLEX-4/11/2015 RR40295266-01 FLEXAFW-1 Connection 3
Piping Add FLEX-4/11/2015 RR40295266-02 FLEXAFW-2 Connection 3
Tank Manway Replace Bolting 09/26/2014 RR40295266-23 3T8 CST on Manway Piping Install 3
Temporary 8/25/2014 RR40329808M02 ICW Piping Cooling 3
Basket Strainer Install Blind 08/22/2014 RR40329808-03 BS-3-1402 Flanges 5
L-2016-044, Attachment FORM OAR-1 OWNER'S ACTIVITY REPORT TABLE2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code Class Item Description Date Repair/Replacement Description Of Work Completed Plan Number 3
Basket Strainer Install Blind 08/22/2014 RR40329808-06 BS-3-1403 Flanges 3
Basket Strainer Reinstall 11/19/2014 RR40329808-08 BS-3-1402 Backwash Piping 3
Basket Strainer Reinstall 11/19/2014 RR40329808-09 BS-3-1403 Backwash Piping 3
Piping Install Temp 05/30/2015 RR40376230-11 ICW Piping Cooling 3
Basket Strainer Install Blind 5/25/2015 RR40376230-12 BS-3-1402 Flanges 3
Basket Strainer Reinstall 5/26/2015 RR40376230-15 BS-3-1403 Backwash Piping ccw 3
Piping Supports Supplemental 8/11/2015 RR40369651-23 CCW Supports Cooling Modification ccw 3
Piping Supplemental 9/3/2015 RR40369651-57 CCW Piping Cooling Modification ccw 3
Piping Supplemental 9/3/2015 RR40369651-20 CCWPiping Cooling Modification 6
U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555-00001 Re:
Turkey Point Unit 3 Docket No. 50-250 lnservice Inspection Program Owner's Activity Report (OAR-1)
FEB 2 6 2016 L-2016-044 10 CFR 50.55a Attached find the Owner's Activity Report (Form OAR-1), for Turkey Point Unit 3 Fifth lnservice Inspection Interval, First Period, Second Refueling Outage (PTN 3-28). The Form OAR-1, Owner's Activity Report, implements Code Case N-532-5.
Should there be any questions concerning this report, please contact Mr. Mitch Guth, Licensing Manager, at 305-246-6698.
Sincerely,
~l~...---, -
A~mas Summers Vice President Turkey Point Nuclear Plant SM Attachment Florida Power & Light Company 9760 S.W. 344'" Street Homestead, FL 33035
FORM OAR-'1 OWNER'S ACTMTY REPORT ReportNumb~r. ISl'-PTN3~28,
- p f~nt:
Turkev Point Nuclear Power Plant Unit 3 9760 SW 344th Street Homestead. Florida* 33035 L-2016-044, Attachment Co'r'nrriet'yial Service' Date: December 14. 1972 Refueling Outage No.i PTN 3,...2a Curreritlnsp~ctiof).lnterv'al.: ISi-Fifth. IWE-Secohd CurrenUnspectlori Periqd: ISi Fifth Interval-First Period and IWE Second lnterv'al ""Third' Period.
Ed.i.tio11 and Add~oda of Section XI applicable tq the inspection plans: ISi Fifth lnterval;.zb(ri t=dition.with Addenda through 2b08 and* IWE-2001 with Addenda through 2003; Date and Revision of Inspection Plans: I Si Fifth.Interval Effective-Februarv*2212014:' Rev. o and IWE Second Interval Effective March 3, 2009; Rev,o
. Edition and Aqc;fenda of$~ction XI applJcable tt> repairs and repla~inents, if differentthan the iiJspectlon* plan: ASME Section Xl2oo7 EditioMhrough 2008 Addenda.
Code* ea~es Used: As Referenced in the IS I Program Plan and Schedule
. CERTIFICATE' OF CONFORMANCE I certify that. (a). the* statem,ents *made ih: this report are correct;_ (b) th.e examjn~tions ang tests 111eetthe Inspection plan; as required.by the'.ASfy1J: Cqde *. section XI; ancl (c)_t~e
~epairlr'epl~cemen.t activities and eyalllatfons supporting the completibn of PTN3'-2S conform to. the requirements of *Section Xi.
..£ Date
,4/?z.. /tc.
I Signed.:£; P., <1*~.. P#r /.tu&;Ac.. (._t.c;~... * /'<&if,
- Owner:or Owner's oe*slgne~~-Title' CERTIFICATE' OF INSgRVICE INSPECTIQN I, the* lindersign.ed1 holding a valid commission issued by the National Board *of Boller and Pressure Vessel Inspectors and the Stater or Province of Georgia and employed by the Hartford Steam Boiler lqspection and Insurance Company c;if Connecti94t Jiave iiispe.cfe~ the items ciescribed in this *owner's ActivitY Report, and state that, to th~ Qest of my knowledge and b~lief, the* OV'liner' lias p~iforme9 all activities Jepresent~d by ftiis report in accordance wit_h the reqLiiremeh~s ofSection XI.
Sy signing this. certificate n~ither the Inspector nor his employer makes any warranty; e:>(pre.sseQ Qr implied, -conceming*the repair/replacement activities and evalur~tion described in this report. Furthermore; neither the inspector nor his employer shall be liable in any:.manner for any personalinjury or roperty daltiage or loss of anyJ<irid arising from or connected With this irisp.ection, Date./&~!M:j
L-2016-044, Attachment FORM OAR-1 OWNER'S ACTIVITY REPORT TABLE 1 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Examination Category and Item Description Evaluation Description Item Number NONE NONE NONE 2
L-2016-044, Attachment FORM OAR-1 OWNER'S ACTIVITY REPORT TABLE2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code Class Item Description Date Repair/Replacement Description Of Work Completed Plan Number Snubbers Replace 1,2,3 Various Snubbers and 11/19/2015 RR40351819-01 Load Pins 1
Valve Replace 11/30/2015 RR37020966-01 3-385 1
Valve Replace Bonnet 11/30/2015 RR40160997-01 CV-3-200B Bolting 1
Safety Valve Replace Bonnet 11/30/2015 RR40352529-01 RV-3-551B Nut Support Remove 2
indication from 11/21/2015 RR40425245-01 8080-R-006-01 support 2
Valve Replace Valve 11/30/2015 RR40161364-01 SGWL-3-025 2
Valve Replace bonnet 11/30/2015 RR40272223-26 CV-3-303A bolting 2
Valve Replace bonnet 11/30/2015 RR40355834-26 CV-3-303B bolting 2
Valve Replace bonnet 11/30/2015 RR40355835-26 CV-3-303C bolting 3
L-2016-044, Attachment FORM OAR-1 OWNER'S ACTIVITY REPORT TABLE2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code Class Item Description Date Repair/Replacement Description Of Work Completed Plan Number 2
Relief Valve Replace Flange 11/30/2015 RR40034113-01 RV-3-858B Bolting Piping near Remove tooling 2
Valve 3-293C marks in pipe 11/21/2015 RR40428318-01 2
Piping near Remove Arc 11/21/2015 RR40428320-01 Valve 3-293A Strikes on piping Piping Modify Piping 2
3ARCP during RCP 11/30/2015 RR40272223-21 modification Piping Modify Piping 2
3BRCP during RCP 11/30/2015 RR40355834-18 modification Piping Modify Piping 2
during RCP 11/30/2015 RR40355835-18 3CRCP modification 3
Relief Valve Replace Bolting 12/04/2015 RR404197 44-01 RV-3-1412 3
Relief Valve Replace Valve 11/15/2015 RR40281615-02 RV-3-707 with New 3
Heat Exchanger Retube Heat 2/20/2015 RR40088991-01 3E207A Exchanger 3
Heat Exchanger Retube Heat 03/06/2015 RR40088994-01 3E207B Exchanger 4
L-2016-044, Attachment FORM OAR-1 OWNER'S ACTIVITY REPORT TABLE 2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code Class Item Description Date Repair/Replacement Description Of Work Completed Plan Number 3
Heat Exchanger Retube Heat 2/07/2015 RR40088995-01 3E207C Exchanger 3
Valve Replace Valve 07/10/2015 RR40243391-01 3-50-321 3
Piping Add FLEX-11/26/2014 RR40295266-10 FLEX CST-1 Connection 3
Piping Add FLEX~
9/22/2015 RR40295266-11 FLEX CST-2 Connection 3
Piping Add FLEX-7/2/2015 RR40295266-13 FLEX SFP-1 Connection 3
Piping Add FLEX-4/11/2015 RR40295266-01 FLEXAFW-1 Connection 3
Piping Add FLEX-4/11/2015 RR40295266-02 FLEXAFW-2 Connection 3
Tank Manway Replace Bolting 09/26/2014 RR40295266-23 3T8 CST on Manway Piping Install 3
Temporary 8/25/2014 RR40329808M02 ICW Piping Cooling 3
Basket Strainer Install Blind 08/22/2014 RR40329808-03 BS-3-1402 Flanges 5
L-2016-044, Attachment FORM OAR-1 OWNER'S ACTIVITY REPORT TABLE2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code Class Item Description Date Repair/Replacement Description Of Work Completed Plan Number 3
Basket Strainer Install Blind 08/22/2014 RR40329808-06 BS-3-1403 Flanges 3
Basket Strainer Reinstall 11/19/2014 RR40329808-08 BS-3-1402 Backwash Piping 3
Basket Strainer Reinstall 11/19/2014 RR40329808-09 BS-3-1403 Backwash Piping 3
Piping Install Temp 05/30/2015 RR40376230-11 ICW Piping Cooling 3
Basket Strainer Install Blind 5/25/2015 RR40376230-12 BS-3-1402 Flanges 3
Basket Strainer Reinstall 5/26/2015 RR40376230-15 BS-3-1403 Backwash Piping ccw 3
Piping Supports Supplemental 8/11/2015 RR40369651-23 CCW Supports Cooling Modification ccw 3
Piping Supplemental 9/3/2015 RR40369651-57 CCW Piping Cooling Modification ccw 3
Piping Supplemental 9/3/2015 RR40369651-20 CCWPiping Cooling Modification 6