L-2014-519, ESLO2014-002, NPDES Receiving Water Monitoring Program: 2013 Annual Report

From kanterella
Jump to navigation Jump to search
ESLO2014-002, NPDES Receiving Water Monitoring Program: 2013 Annual Report
ML14133A624
Person / Time
Site: Diablo Canyon  
Issue date: 03/31/2014
From:
Tenera Environmental Services
To:
Office of Nuclear Reactor Regulation, Pacific Gas & Electric Co
Shared Package
ML14133A631 List:
References
DCL-2014-519 ESLO2014-002
Download: ML14133A624 (137)


Text

Pacific Gas and Electric Company Diablo Canyon Power Plant NPDES RECEIVING WATER MONITORING PROGRAM: 2013 ANNUAL REPORT March 31, 2014 Submitted to: Pacific Gas and Electric Company Diablo Canyon Power Plant Avila Beach, CA 93424 Prepared by: TiNiR Environmental 141 Suburban Rd., Suite A2 San Luis Obispo, CA 93401 0 ESL02014-002 Table of Contents Table of Contents

1.0 INTRODUCTION

....................................................................................................................

1 2.0 TEMPERATURE M ONITORING

.............................................................................................

4 3.0 INTERTIDAL ALGAE AND INVERTEBRATES

....................................................................

9 4.0, INTERTIDAL FISHES ...........................................................

11 5.0 SUBTIDAL ALGAE AND INVERTEBRATES

.....................................................................

12 6.0 SURFACE CANOPY K ELPS .................................................................................................

14 7.0 SUBTIDAL FISHES .........................................................................................................

15 8.0 RWMP PROJECT PERSONNEL

......................................................................................

17 9.0 LITERATURE CITED ......................................................................................................

18 APPENDIX A. Intertidal Temperatures APPENDIX B. Subtidal Temperatures APPENDIX C. Intertidal Algae, Invertebrates and Substrates (HBTMethod)

APPENDIX D. Intertidal Fishes (VBTMethod)

APPENDIX E. Subtidal Algae and Invertebrates (SAQ Method)APPENDIX F. Subtidai Algae (SLC Method)APPENDIX G. Subtidal Invertebrates (SFQ Method)APPENDIX H. Subtidal Fishes (SFO Method)ESLO2014-002

___N PG&E

  • DCPP-RWMP 2013 Annual Report Table of Contents List of Tables Table 1. Tasks, stations, and frequency of surveys for the DCPP RWMP, 2013. (See text for sampling m ethod descriptions and station locations)

.....................................................................................

2 List of Figures Figure 1. Location of the Diablo Canyon Power Plant .........................................................................

3 Figure 2. Locations of intertidal temperature monitoring stations ........................................................

6 Figure 3. Locations of subtidal temperature monitoring stations ...........................

6 Figure 4. Seawater temperatures in 2013 recorded in South Control, south Diablo Cove, north Diablo Cove, and Field's Cove for: a) intertidal; and b) subtidal.

Mean, maximum, and minimum temperatures are shown by month for each area ..............................................................................

7 Figure 5. DCPP average daily intake and discharge seawater temperatures

(°C) and the daily cooling w ater discharge volum e (M G D ) .....................................................................................................

8 Figure 6. Locations of horizontal band transect stations .......................................................................

9 Figure 7. Locations of vertical band transect stations ................................................................................

11 Figure 8. Locations of subtidal benthic stations ...................................................................................

13 Figure 9. Map of surface kelp in Diablo Cove on October 1, 2013 .....................................................

14 Figure 10. Locations of subtidal fish observation transects

..................................................................

15 9(p, ESLO2014-002 431-. PG&E

  • DCPP-RWMP 2013 Annual Report

1.0 Introduction

1.0 Introduction

Monitoring of the marine environment near the Diablo Canyon Power Plant (DCPP) is required by WDR Order No. 90-09 (National Pollutant Discharge Elimination System (NPDES) Permit No. CA000375 1), as revised in a letter from the Central Coast Regional Water Quality Control Board in December 1998. Changes in the marine environment in the vicinity of DCPP (Figure 1)are monitored by the Receiving Water Monitoring Program (RWMP) in accordance with the NPDES Permit.This report presents seawater temperature and biological data collected in 2013 from the program's intertidal and subtidal monitoring tasks (Table 1). The sampling methods for each task are described, and the results are presented in the report's appendices.

The biological monitoring tasks were completed at fixed stations in areas that experience increased seawater temperatures from the DCPP thermal discharge, and in areas outside the influence of the discharge (Table 1). With the exception of the habitat-forming kelp survey task, the sampling frequency for the tasks was four surveys per year. A survey consisted of sampling several locations (stations) over a period of time, which varied depending on logistics, staffing resources, weather, sea state, and tide conditions.

The survey date listed in the appendix tables for any particular task represents the mean date of the time period the stations were sampled for that survey. All monitoring tasks and surveys were completed in 2013 as planned.This report does not include analysis or discussion of the results of the biological or temperature monitoring.

Comprehensive analyses of changes in the marine environment resulting from the DCPP discharge have been presented in Tenera (1988, 1997, 1999a, 1999b, 2002).ESL02014-002 PG&E

  • DCPP-RWMP 2013 Annual Report

1.0 Introduction

Table 1. Tasks, stations, and frequency of surveys for the DCPP RWMP, 2013. (See text for sampling method descriptions and station locations).

Task and Sampling Frequency Stations Temperature Monitoring (measurements every 20 min)NC 2, FC 1, FC 2, FC 3, NDC 1, NDC 2, NDC 3, SDC 1, SDC 2, SDC 3, SDP 1, SDP 2, SC 1, and SC 1V NC 1 -3m, FC 1 -3m, NDC 2 -3m, NDC 3 -3m, NDC 4 -4m, SDC 1 -3m, SDC 4 -4m, SC 1 -3m, and SC 2 -6m Intertidal Horizontal Band Transects (algae, seagrasses, invertebrates, substrate)

NC 1, NC 2, FC 1, FC 2, FC 3, NDC 1, NDC 2, NDC 3, SDC 1, 4 surveys per year SDC 2, SDC 3, SDP !, SDP 2, and SC I Intertidal Vertical Band Transects (fishes)4 surveys per year NC 1V, FC 1V, NDC 1V, SDC 2V, and SC 1V Subtidal Benthic Stations (algae, invertebrates, substrate)

FC 1 -3m, NDC 2 -3m, NDC 3 -3m, NDC 4 -4m, SDC 2 -3m, SDC 3 -4m, 4 surveys per year SC 1 -3m, and SC 2 -6m Subtidal Fish Observations (fishes)FC FO-1, FC FO-2, FC FO-3, NDC FO-1, NDC FO-2, NDC FO-3, SDC FO-1, 4 surveys per year SDC FO-2, SDC FO-3; SC FO-1, SC FO-2, and SC FO-3 Habitat-Forming Kelp Survey (bull kelp, giant kelp)1 survey per year Diablo Cove fi' ESL02014-002 PG&E

  • DCPP-RWMP 2013 Annual Report 2

1.0 Introduction

Figure 1. Location of the Diablo Canyon Power Plant./j ESLO2014-002 PG&E -DCPP-RWMP 2013 Annual Report 3 2.0 Temperature Monitoring 2.0 Temperature Monitoring Intertidal and subtidal seawater temperatures were recorded at permanent stations located along the Diablo Canyon coastline.

Temperature units at intertidal stations were located along the rocky shore at the +0.6 m (+2.0 ft) mean lower low water (MLLW) elevation (Figure 2).Subtidal temperature recorders were located at depths from -3 m to -6 m (-10 ft to -20 ft) MLLW (Figure 3). The naming designation of individual stations reflects the area location and station number, and for the subtidal stations includes the station's depth relative to MLLW (e.g., NDC 1-3 m is north Diablo Cove subtidal Station I at a depth of-3 m MLLW).The following 13 stations were located in Diablo Cove, and were contacted regularly by the discharge plume: Intertidal:

NDC 1, NDC 2, NDC 3, SDC 1, SDC 2, SDC 3, SDP 1, and SDP 2.Subtidal:

NDC 2 -3m, NDC 3 -3m, NDC 4 -4m, SDC 1 -3m, and SDC 4 -4m.The following four stations were located in Field's Cove, approximately one kilometer upcoast from Diablo Cove, and were contacted intermittently by the discharge plume: Intertidal:

FC 1, FC 2, and FC 3.Subtidal:

FC I -3m.The following six control stations measured ambient ocean temperatures at locations beyond the influence of the discharge:

Intertidal:

NC 2, SC 1, and SC 1V.Subtidal:

NC 1 -3m, SC 1 -3m, and SC 2 -6m.Each instrument synchronously logged temperatures every 20 minutes throughout its deployment period. Instrument precision was 0.025'C with an accuracy of +/- 0.05'C. Temperature units were deployed at a station for approximately 60-90 days and then exchanged with a serviced, calibrated unit. Intertidal temperature units recorded water temperatures only when tide levels were higher than about +0.6 m MLLW. Air temperatures were removed from the database by matching the temperature records with the times that the tide level dropped below +0.6 m MLLW, using a tidal height database derived from NOAA tide gauges at Morro Bay and Port San Luis.Seawater temperatures recorded at the intertidal and subtidal temperature monitoring stations in 2013 are presented in Appendix A and Appendix B, respectively.

Below is a summary of seawater temperatures recorded in the year, based on data from a subset of the temperature recording stations in the control areas, north Diablo Cove, south Diablo Cove, and Field's Cove.ESLO2014-002 PG&E ° DCPP-RWMP 2013 Annual Report 4 2.0 Temperature Monitoring Intertidal monthly mean, maximum, and minimum temperatures recorded in 2013 at the +0.6 m (+2.0 ft) (MLLW) elevation at stations in South Control (SC 1), south Diablo Cove (SDC 1), north Diablo Cove (NDC 2), and Field's Cove (FC 2) are shown in Figure 4a. Monthly mean ambient seawater temperatures at the South Control station ranged from a low of 1 .0°C (51.8°F) in February and April to a high of 13.8°C (56.8°F) in October. Intertidal seawater temperatures were generally warmest at the Diablo Cove stations in late summer-early fall.Compared to the control station, intertidal seawater temperatures averaged 4.5°C (8.1°F) warmer in south Diablo Cove and 4.3 0 C (7.7°F) warmer in north Diablo Cove. Intertidal seawater temperatures at the Field's Cove station were 1.3°C (2.3°F) warmer than the control station, on average.Subtidal monthly mean, maximum, and minimum temperatures recorded in 2013 at -3 m MLLW in South Control (SC I -3m), south Diablo Cove (SDC 1 -3m), north Diablo Cove (NDC 2 -3m), and Field's Cove (FC 1 -3m) are shown in Figure 4b. Monthly mean ambient seawater temperatures at the South Control station ranged from a low of 11 .0C (51.8°F) in April to a high of 13.8°C (56.8°F) in October. Subtidal temperatures were generally warmest at the Diablo Cove stations in summer-early fall. Compared to the control station, subtidal temperatures averaged 3.0°C (5.4°F) warmer in south Diablo Cove and 4.3°C (7.7°F) warmer in north Diablo Cove.Subtidal temperatures at the Field's Cove station were I.I°C (2.0°F) warmer than the control station on average.DCPP typically operates at full capacity, but there were several periods in 2013 when one or two of the four main circulating water pumps (CWP) were not in service because of scheduled and unscheduled outages or curtailments.

This resulted in lower volumes of heated seawater flowing into Diablo Cove. These periods can be seen in Figure 5, and include such activities as the curtailment of Unit 1 on June 26-28 to repair a boric acid leak, a Unit 2 outage on July 10-12 to repair a damaged transformer, and the cleaning of biofouling from the walls of the Unit 1 cooling water conduits during the period from October 27 through November 2. During the brief leak repair curtailment and transformer maintenance outage, and the cooling water conduit cleaning curtailment, only one of the two affected unit's circulators remained in service. During the 2R17 refueling outage that ran from February 3 through March 23, both of the CWPs for Unit 2 were out of service. This resulted in the total volume of heated seawater flowing into Diablo Cove being reduced by approximately one-half during this period.ESLO2014-002 f"mV PG&E -DCPP-RWMP 2013 Annual Report 5 2.0 Temperature Monitoring North Control Lion Rock Field's Cove Diablo Rock NDC 1 Diablove SIDP I Cv SDP 2 Intake Cove Point San Luis \South Control (Patton Cove.Figure 2. Locations of intertidal temperature monitoring stations.North Control Lion Rock FC 1-3m Field's Cove Diablo Rock% Diablo Cove Point San Luis \tIC71N, Intake Cove South Control /(Patton Cove)Figure 3. Locations of subtidal temperature monitoring stations.ESLO2014-002 PG&E

  • DCPP-RWMP 2013 Annual Report 6 2.0 Temperature Monitorinq a) Intertidal Temperatures 25.0 21.0 0 17.0 C)E 9-I 0 0.9 0'.1 13.0 9.0 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 2013 UControl 0 South Diablo Cove o North Diablo Cove 13 Field's Cove b) Subtidal Temperatures 25.0 77.0 21.0 69.8 o 17.0 62.6 E I0 13.0 56.4 9.0 ---48.2 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 2013 Figure 4. Seawater temperatures in 2013 recorded in South Control, south Diablo Cove, north Diablo Cove, and Field's Cove for: a) intertidal; and b) subtidal.

Mean, maximum, and minimum temperatures are shown by month for each area. (See text for temperature recording stations used in this figure).Ii' ESLO2014-002 PG&E ° DCPP-RWMP 2013 Annual Report 2.0 Temperature Monitoring 30 25 20 15 10 0.E)I..3000 2500 2000 1500 CD 0 1000 500 0 5 0 4 1 1 1 1 1 -I Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 2013 Figure 5. DCPP average daily intake and discharge seawater temperatures (0 C) and the daily cooling water discharge volume (MGD).I" ESLO2014-002 PG&E

  • DCPP-RWMP 2013 Annual Report 8 3.0 Intertidal Algae and Invertebrates 3.0 Intertidal Algae and Invertebrates Intertidal algae, seagrasses, and invertebrates were sampled using the horizontal band transect (HBT) sampling method at the locations shown in Figure 6. Most HBT stations consisted of two 30 m long transects oriented parallel to the waterline, one at the +0.9 m (+3 ft) MLLW tide level and the other at the +0.3 m (+I ft) MLLW tide level. Stations SDP 1 and SDP 2 each consisted of one transect at the +0.9 m tide level. The substrate at the +0.9 m MLLW level at Station SDC I was mainly uncolonized cobble. Therefore, the upper transect at that station was located at a lower elevation at the +0.6 m MLLW tide level, and on bedrock where intertidal species were more abundant.

The sampling area of each transect consisted of ten 1.0 m 2 permanent quadrats.

The quadrats were mainly located on bedrock and boulders, but various amounts of cobble and sand that occurred seasonally were also sampled. Three control stations were located beyond the range of thermal discharges from DCPP, while the remaining 11 stations in Field's Cove, Diablo Cove, and on South Diablo Point (south headland of Diablo Cove) received varying levels of contact with warm water from the discharge.

North Control Lion Ro l Field's Cove NDC 1 Diablo Roctk. Diablo Cove SDP I" SDP 2 *Horizontal Band Transect Stations Each station has a +0.3 m and +0.9 m MLLW transect Station with a +0.3 and +0.6 rn MLLW transect Intake Cove Stations with only a +0.9 MLLWtransect South Control (Patton Cove)Point San Luis Figure 6. Locations of horizontal band transect stations.In sampling, visual estimates of percent cover were made for all algal species, seagrasses, and bare substrate.

Overstory species were sampled first for coverage estimates, and then the overstory branches and blades were moved aside to allow estimation of the percent cover of the understory species and bare substrates.

Species that occupied less than 0.7% of the area of the I ESLO2014-002 PG&E e DCPP-RWMP 2013 Annual Report 9 3.0 Intertidal Algae and Invertebrates quadrat were recorded as 'present'.

Total algal cover plus bare substrate cover almost always exceeded 100 percent in a quadrat, due to overlapping layers of multiple plant taxa.Intertidal invertebrates Were sampled concurrently in the same quadrats as the algae. In five of the ten quadrats, all species were recorded as either present or absent, except individuals that were larger than 2.5 cm (1 in) in greatest dimension, which were counted. In the remaining five quadrats ('count quadrats'), the same method was used except that select species of invertebrates were counted regardless of size. The percent cover of sessile invertebrates, such as sponges and tunicates, was estimated using the same methods used for the algae. All invertebrates, algae, and seagrasses were identified to the lowest taxonomic level practical.

Black abalone of all sizes were counted in the ten permanent quadrats and in five additional quadrats on each transect.The survey mean and standard deviation, and annual mean abundance for each taxon at each transect level are presented in Appendix C. Survey statistics for algae and substrates were calculated from all ten quadrats along the transect, while statistics for the invertebrates were calculated from the five 'count' quadrats.

If a taxon was only recorded as present in a quadrat, its abundance was given a value of 0.000001 for calculating summary statistics.

ESL02014-002 PG&E -DCPP-RWMP 2013 Annual Report 10 4.0 Intertidal Fishes 4.0 Intertidal Fishes Intertidal fishes were sampled using the Vertical Band Transect (VBT) sampling method. At each of five stations (Figure 7), three transects were positioned perpendicular to the shoreline at fixed locations.

Each transect originated in the high intertidal zone (approximately

+1.5 m MLLW) and terminated in the low intertidal zone (approximately

-0.2 m MLLW). Transects at each station were separated by approximately 3 m. Each transect was used as a reference line to position twelve 1.0 m 2 permanent sampling quadrats, for a total of thirty-six 1.0 m 2 quadrats per station. Two control stations were located beyond the range of thermal discharges from DCPP, while the remaining three stations in Field's Cove and Diablo Cove received varying amounts of warm water influence from the discharge.

In sampling, moveable rocks were carefully lifted and any fishes seen were captured in small hand nets. Foliose algae were also searched for cryptic fishes. Fishes were identified to the lowest practical taxonomic level, measured, and returned to the quadrat following sampling.Newly settled juvenile fishes were not identified to the species level but were grouped into composite taxa (e.g., Pholididae/Stichaeidae, Anoplarchus/Cebidichthys).

The total numbers observed at each station during the four surveys of the year, and annual mean abundance and standard deviation of fishes for each taxon are presented in Appendix D.North Control NC IV Lion Rock r Field's Cove Diablo Rock,. Diablo V Cove Point San Luis \SDC 2V Intake Cove South Control-U., , 'Ovel Figure 7. Locations of vertical band transect stations.'\ ESLO2014-002 f.AMN PG&E

  • DCPP-RWMP 2013 Annual Report 11 5.0 Subtidal Algae and Invertebrates 5.0 Subtidal Algae and Invertebrates Eight permanent subtidal benthic sampling stations located in depths ranging from -3 m to -6 m (-10 ft to -20 fi) MLLW were sampled during the year (Figure 8). Two control stations were located in Patton Cove, beyond the range of thermal discharges from DCPP, while the remaining six stations received varying amounts of warm water influence from the discharge.

Stations were circular with a radius of 3.15 m and a sampling area of 28.0 m 2.The center 3.1 mi 2 of each station, which surrounded a mooring anchor (railcar wheel), was not sampled in order to avoid any unnatural algal and invertebrate growth associated with the mooring. Each station was divided into four equal sections, or 'arc quadrants', 7.0 m2 in area. All stations were established primarily on substrates of mixed bedrock and boulders with small amounts of cobble and sand.Divers used three sampling methods at each station to sample the benthic algae and invertebrates.

In the first method, individual species of kelp (brown algae of the order Laminariales and Fucales) and macroinvertebrates were counted in each subtidal arc quadrant (SAQ sampling method). Kelp plants and individuals of select invertebrate taxa were counted regardless of their size. Individuals of other non-encrusting invertebrates were counted if they were larger than 2.5 cm (1.0 in) (length or width). Juvenile kelp plants that could not be identified to the species level were counted and recorded as 'Laminariales.'

Five common species that generally occurred in numbers too high to accurately count in a large area were sampled in the same one-third area (2.33 m 2) of each quadrant, each survey. The count for each of these species was multiplied by three to provide an abundance estimate for the entire quadrant.In the second sampling method (subtidal line contact or SLC) all understory algal species were quantified at the stations as percent cover using a series of pre-selected random points. A radius line with ten lead markers positioned at decreasing intervals toward the station perimeter was attached to the center of the station and used to locate sampling loci in each quadrant.

Fifty random contact points were sampled within each quadrant (total of 200 points per station), and the same pre-selected set of points was used at all stations.

Random sampling points were changed for each survey. The presence of all algal species, sessile invertebrates, and substrates observed directly under or over the points was recorded.

Holdfasts of kelp species were also included when contacted by the sample points. The percent cover of each species and substrate type was calculated by dividing the number of 'contacts' by the number of points sampled. All algal species on the station were identified to the lowest taxonomic level practical.

In each quadrant, algal species that were present but not contacted by the sample points were noted separately as being 'present' in the quadrant.In the third method, invertebrates were sampled using the subtidal fixed quadrat (SFQ) method in four permanent circular 0.25 m 2 quadrats at each station. The method quantified species composition and abundance of all invertebrate taxa visible to the naked eye. One permanent quadrat was located within each of the four SAQ quadrants, generally on bedrock or boulder substrate.

Depending upon the degree of topographical relief, two quadrats were located onESL02014-002 PG&E

  • DCPP-RWMP 2013 Annual Report 12 5.0 Subtidal Algae and Invertebrates horizontal-aspect surfaces and two quadrats were located on vertical-aspect surfaces.

All non-encrusting taxa were identified and counted. The coverage of encrusting taxa (e.g., colonial/social tunicates) was quantified in square inch units if the total equaled or exceeded 1 square inch (6.5 cm2). Otherwise, the encrusting taxon was recorded as 'present'.

The survey mean and standard deviation for each taxon at each station from the four surveys completed during the year are presented in Appendices E (SAQ), F (SLC), and G (SFQ). The means are based on the data from the four quadrats or quadrants at each station. The tables also list annual mean taxa abundances by station based on the average of all surveys sampled over the year. Algal taxa in the SLC study, and encrusting taxa in the SFQ study, that were recorded as only present (no numeric value) were given a value of 0.000001 for calculating abundance statistics.

North Control Lion Rock Field's Cove FC 1-3m Diablo Rock*. Diablo Cove Point San LUis \ta o Intake Cove South Control '1Iatotn r-\Figure 8. Locations of subtidal benthic stations.I" ESLO2014-002 PG&E

  • DCPP-RWMP 2013 Annual Report 13 6.0 Surface Canopy Kelps 6.0 Surface Canopy Kelps The locations and extent of the surface kelp canopies of Nereocystis luetkeana (bull kelp) and Macrocystis pyrifera (giant kelp) in Diablo Cove within and outside the fixed benthic stations were mapped from direct observations.

This task has been completed annually since the 1970s to document long-term changes in the annual maximum extent of the surface kelp canopies in Diablo Cove. Near the end of the annual growth cycle in October, nearly all bull kelp plants have reached the surface and can be counted. Surface canopies of giant kelp also tend to be abundant during this period. Two observers at the headland of north Diablo Cove and two observers at the headland of south Diablo Cove (south Diablo Point) counted and mapped the distribution of individual bull kelp plants and mapped the spatial extent of giant kelp canopies (Figure 9). Bull kelp plants with bare bulbs only and no attached fronds, indicating senescence in the plants, were noted when possible.The annual habitat-forming kelp survey was conducted on October 1, 2013. No bull kelp plants were observed in Diablo Cove during the survey; giant kelp canopies occurred in both north and south Diablo Cove (Figure 9). There are no appendix figures or data tables associated with this task.0~0.25 Mthe 0 SO0.Figure 9. Map of surface kelp in Diablo Cove on October 1, 2013.0 ESLO2014-002 PG&E

  • DCPP-RWMP 2013 Annual Report 14 7.0 Subtidal Fishes 7.0 Subtidal Fishes Visual counts of fishes were conducted by divers at 12 permanent subtidal stations (three stations in each of four areas) located within and outside of Diablo Cove (Figure 10). Three control stations located in Patton Cove were beyond the range of thermal discharges from DCPP, while the remaining nine stations in Field's Cove, north Diablo Cove, and south Diablo Cove received varying amounts of warm water influence from the discharge.

Each station consisted of a benthic transect 50 m long by 4 m wide by 1 m above the bottom, and a 50 m long by 4 m diameter midwater transect located above and parallel to the benthic transect approximately midway between the surface and the bottom. A station was sampled by first deploying a fiberglass measuring tape to delineate the centerline of the benthic transect, beginning at a permanent station buoy and extending 50 m away from the buoy along a pre-determined compass course. Some transects crossed over each other where a transect parallel to the depth contour crossed over a transect positioned perpendicular to the depth contour. The area common to both transects in these cases was approximately 2%. This small overlap did not affect the data summaries because the numbers of fish counted were averaged by area, and the mobility of most fish added to the independence of transects.

North Control FC FO-2 Field's Cove 7<FC FO-3 'Diablo Rockd Diablo*Cove Point San Luis \Intake Cove South Control IPatton rove-Figure 10. Locations of subtidal fish observation transects.

/j' ESLO2014-002 PG&E -DCPP-RWMP 2013 Annual Report 15 7.0 Subtidal Fishes A survey team consisted of two divers. Each diver counted fish along the benthic and midwater transect sampling areas, swimming in opposite directions along the transects.

This sampling technique allowed a more thorough inspection of potential fish habitats from all angles of view than would have been possible by a single diver progressing along a transect in only one direction.

Fish were identified to species if possible, but juveniles of some species with similar appearances were combined into broader categories if necessary.

The resulting survey data per transect were the combined species counts of both divers, divided by two. This yielded an average count for each taxon per 50 m by 4 m benthic transect and per 50 m long by 4 m diameter midwater transect.

During each survey, the stations (midwater and benthic transects) were usually sampled a second time (replicate

2) within two weeks of the initial sampling effort (replicate 1), unless adverse sea conditions precluded a second replicate.

The replicate 1 and 2 data per area were pooled separately for the three midwater transects and the three benthic transects for each survey.The survey mean abundance and standard deviation for each taxon within each of the four sampling areas for the four surveys during the year are presented in Appendix H. The tables are further divided according to midwater and benthic transects in each area. The tables also show overall mean abundances for the entire year. The survey dates shown for each area in the tables represent the average date of the combined stations sampled in replicates 1 and 2.__,ESLO2014-002 PG&E -DCPP-RWMP 2013 Annual Report 16 8.0 Project Personnel 8.0 RWMP Project Personnel Project Personnel 2013 Tenera Environmental Principal Investigator Project Manager: Project Scientists:

Project Staff-Mr. John Steinbeck Mr. Jay Carroll Mr. Gery Cox Mr. Dan Dugan Mr. Chris Ehrler Mr. Andrew Harmer Mr. Rick Hernandez Mr. Scott Kimura Dr. Joe Phelan Mr. Steve Pengilley Ms. Shelly Witters Ms. Kristen Sanchez Mr. Jim Strampe Ms. Susan Helberg Pacific Gas and Electric Company Program Manager: Mr. Jim Kelly ESL02014-002 PG&E

  • DCPP-RWMP 2013 Annual Report 17 9.0 Literature Cited 9.0 Literature Cited Tenera Environmental, Inc. 1988. Diablo Canyon Power Plant, Final Report, Thermal Effects Monitoring Program, Volume 1. Pacific Gas and Electric Company, San Francisco, CA.Tenera Environmental, Inc. 1997. Thermal effects monitoring program, analysis report: Chapter 1 -Changes in the marine environment resulting from the Diablo Canyon Power Plant discharge.

Pacific Gas and Electric Company, San Francisco, CA.Tenera Environmental, Inc. 1999a. Receiving Water Monitoring Program -1995-1997 Progress Report. Pacific Gas and Electric Company, San Francisco, CA.Tenera Environmental, Inc. 1999b. Receiving Water Monitoring Program -1995-1998 Progress Report. Pacific Gas and Electric Company, San Francisco, CA.Tenera Environmental, Inc. 2002. Diablo Canyon Power Plant, Receiving Water Monitoring Program -1995-2002 Analysis Report. Pacific Gas and Electric Company, San Francisco, CA ESL02014-002 PG&E -DCPP-RWMP 2013 Annual Report 18 Diablo Canyon Power Plant Appendix A Intertidal Temperatures Appendix A -Intertidal Temperatures Table Al. Monthly statistical summary of intertidal temperatures

(°C), January-December 2013, North Control Station NC 2 +0.6m (2+2).Month Max Min Mean Std. Dev N Station: NC 2 +0.6m Jan 13.73 9.77 11.82 0.82 1158 Feb 13.00 9.73 11.06 0.63 1012 Mar 14.48 9.90 11.30 0.77 1087 Apr 14.57 9.38 11.60 1.27 1054 May 15.18 9.60 12.50 1.35 1095 Jun 15.70 9.90 12.82 1.30 1091 Jul 15.98 11.48 14.03 0.89 1193 Aug 16.38 12.40 14.32 0.79 1287 Sep 16.83 10.93 13.69 1.34 1243 Oct 15.55 11.52 13.87 0.89 1268 Nov 15.20 11.55 13.48 0.66 1190 Dec 14.65 9.85 12.76 0.82 1192 0MW ESLO2014-02 A-1 Appendix A -Intertidal Temperatures Table A2. Monthly statistical summary of intertidal temperatures

(°C), January-December 2013, Field's Cove Stations FC I +0.6m (4+2), FC 2 +0.6m (5+2) and FC 3+0.6m (6+2).Month Max Min Mean Std. Dev N Station: FC 1 +0.6m Jan 15.07 6.20 12.75 0.92 1402 Feb 14.27 9.73 11.39 0.88 1230 Mar 15.90 9.93 11.81 1.03 1317 Apr 16.55 9.00 12.43 1.71 1268 May 17.55 10.02 13.28 1.83 1308 Jun 18.10 10.88 13.86 1.43 1321 Jul 18.42 12.05 15.30 1.18 1468 Aug 18.73 13.18 15.69 1.08 1506 Sep 18.90 11.45 14.73 1.60 1433 Oct 17.52 11.82 14.94 1.16 1437 Nov 16.92 12.43 14.71 0.85 1381 Dec 17.00 10.77 14.02 0.90 1436 Station: FC 2 +0.6m Jan 15.07 10.77 12.79 0.90 1158 Feb 14.20 9.82 11.39 0.85 1012 Mar 15.75 9.93 11.79 1.00 1087 Apr 16.58 9.02 12.33 1.68 1054 May 17.02 10.10 13.15 1.77 1095 Jun 18.10 10.88 13.69 1.37 1091 Jul 18.35 12.05 15.07 1.06 1193 Aug 19.15 12.98 15.53 1.00 1287 Sep 18.45 11.48 14.59 1.51 1243 Oct 17.25 11.80 14.94 1.16 1268 Nov 17.02 12.68 14.76 0.84 1190 Dec 16.98 10.98 14.14 0.87 1192 Station: FC 3 +0.6m Jan 14.88 7.53 12.77 0.91 1158 Feb 14.27 9.82 11.35 0.85 1012 Mar 15.32 9.88 11.74 0.98 1087 Apr 16.13 9.00 12.24 1.63 1054 May 16.90 10.07 13.03 1.72 1095 Jun 17.35 10.85 13.57 1.33 1091 Jul 17.55 12.02 14.90 1.00 1193 Aug 18.30 12.90 15.38 0.98 1287 Sep 18.17 11.45 14.50 1.48 1243 Oct 17.23 11.77 14.91 1.15 1268 Nov 17.08 12.68 14.73 0.84 1190 Dec 16.90 11.40 14.14 0.85 1192 m-W ESLO2014-02 A-2 Appendix A -Intertidal Temperatures Table A3. Monthly statistical summary of intertidal temperatures

(°C), January-December 2013, North Diablo Cove Stations NDC I +0.6m (7+2), NDC 2 +0.6m (8+2)and NDC 3 +0.6m (9+2).Month Max Min Mean Std. Dev N Station: NDC I +0.6m Jan 19.17 10.70 15.53 1.73 1402 Feb 18.70 10.13 13.11 2.06 1230 Mar 20.42 10.45 14.59 2.03 1317 Apr 21.13 9.43 14.99 2.52 1268 May 21.20 10.02 15.94 2.33 1308 Jun 21.63 11.73 16.52 1.88 1321 Jul 21.35 13.10 17.95 1.37 1468 Aug 21.45 15.32 18.38 0.95 1506 Sep 21.08 11.75 17.65 1.88 1433 Oct 21.85 11.75 17.98 1.72 1437 Nov 21.00 13.65 17.69 1.23 1381 Dec 21.73 13.52 17.34 1.27 1436 Station: NDC 2 +O.6m Jan 19.05 10.73 15.55 1.73 1117 Feb 18.33 10.20 13.29 2.12 980 Mar 20.67 10.75 15.03 2.05 1050 Apr 21.27 9.43 15.25 2.56 999 May 21.73 10.10 16.29 2.28 1050 Jun 22.10 11.80 16.79 1.97 1053 Jul 21.33 13.27 18.25 1.34 1152 Aug 21.33 15.48 18.42 0.87 1232 Sep 21.25 11.88 17.86 1.75 1208 OcL 21.92 11.95 18.20 1.67 1229 Nov 20.95 13.85 17.90 1.16 1163 Dec 21.70 13.73 17.42 1.25 1148 Station: NDC 3 +0.6m Jan 19.73 10.77 15.79 1.77 1421 Feb 18.67 10.25 13.75 2.30 1242 Mar 20.77 10.85 15.24 2.01 1333 Apr 21.55 9.45 15.32 2.48 1288 May 21.80 10.07 16.29 2.21 1320 Jun 22.13 11.98 16.83 1.95 1333 Jul 21.45 13.23 18.05 1.35 1488 Aug 21.35 15.38 18.30 0.87 1517 Sep 21.35 11.90 17.89 1.71 1443 Oct 22.42 12.00 18.28 1.64 1450 Nov 21.83 13.85 17.97 1.19 1400 Dec 22.00 13.63 17.54 1.26 1448 MW ESLO2014-02 A-3 Appendix A -Intertidal Temperatures Table A4. Monthly statistical summary of intertidal temperatures

(°C), January-December 2013, South Diablo Cove Stations SDC 1 +0.6m (10+2), SDC 2 +0.6m (11+2)and SDC 3 +0.6m (12+2).Month Max Min Mean Std. Dev N Station: SDC 1 +0.6m Jan 23.02 12.52 16.71 2.19 1438 Feb 20.90 12.55 16.20 1.82 1259 Mar 21.27 11.07 15.39 2.32 1355 Apr 22.92 11.77 16.01 2.26 1295 May 23.23 13.15 16.98 2.03 1340 Jun 23.38 13.55 17.45 1.83 1351 Jul 22.83 13.35 17.58 1.62 1504 Aug 21.90 14.80 17.80 1.20 1530 Sep 23.40 14.43 17.38 1.49 1461 Oct 23.95 14.90 17.73 1.62 1460 Nov 24.55 14.23 17.23 1.77 1409 Dec 24.20 13.75 16.91 1.87 1465 Station: SDC 2 +0.6m Jan 20.90 12.75 15.76 1.30 1158 Feb 19.75 11.95 15.14 1.56 1012 Mar 20.23 11.18 14.96 1.98 1087 Apr 22.70 11.93 15.82 2.13 1054 May 22.63 13.30 17.13 2.01 1095 Jun 23.05 13.63 17.56 1.80 1091 Jul 22.42 13.65 17.85 1.58 1193 Aug 22.00 14.77 18.05 1.22 1287 Sep 20.30 17.17 18.69 0.87 123 Oct -----Nov -----Dec 22.98 14.57 16.79 1.37 752 Station: SDC 3 +0.6m Jan 18.67 11.88 15.18 0.98 1294 Feb 17.15 11.48 14.18 1.20 1137 Mar 18.35 10.90 13.99 1.39 1219 Apr 19.73 11.30 14.71 1.69 1166 May 20.52 12.80 15.82 1.48 1213 Jun 20.98 13.13 16.33 1.40 1222 Jul 20.60 12.95 16.88 1.37 1333 Aug 20.65 14.52 17.25 1.01 1414 Sep 19.75 13.45 16.50 1.37 1349 Oct 20.58 13.82 16.90 1.14 1361 Nov 19.67 13.88 16.46 1.00 1303 Dec 20.38 13.02 16.24 1.23 1332%NW ESLO2014-02 A-4 Appendix A -Intertidal Temperatures Table A5. Monthly statistical summary of intertidal temperatures

('C), January-December 2013, South Diablo Point Stations SDP 1 +0.6m (22+2) and SDP 2 +0.6m (14+2).Month Max Min Mean Std. Dev N Station: SDP 1 +0.6m Jan 18.67 12.32 15.20 0.97 1493 Feb 17.35 11.23 14.09 1.26 1303 Mar 17.45 10.93 13.90 1.32 1395 Apr 19.42 10.75 14.61 1.63 1333 May 20.27 12.77 15.67 1.37 1389 Jun 20.40 13.02 16.08 1.34 1391 Jul 19.98 12.75 16.56 1.37 1548 Aug 19.85 14.32 16.93 1.02 1573 Sep 19.95 13.35 16.32 1.38 1488 Oct 20.52 13.65 16.84 1.16 1497 Nov 19.90 13.93 16.49 0.99 1442 Dec 20.25 13.63 16.30 1.19 1521 Station: SDP 2 +0.6m Jan 17.08 11.80 14.24 0.91 622 Feb -----Mar Apr -----May 17.92 10.32 14.22 1.16 1162 Jun 18.70 10.32 14.58 1.70 1321 Jul 18.90 11.38 14.79 1.51 1468 Aug 19.02 12.13 15.24 1.46 358 Sep -----Oct -----Nov 18.95 13.65 15.92 0.66 1177 Dec 18.42 12.80 15.36 0.77 1436 0OW-ESLO2014-02 A-5 Appendix A -Intertidal Temperatures Table A6. Monthly statistical summary of intertidal temperatures

(°C), January-December 2013, South Control Stations SC I +0.6m (19+2) and SC IV.Month Max Min Mean Std. Dev N Station: SC I +0.6m Jan 13.88 10.43 11.91 0.63 1263 Feb 12.60 9.75 11.02 0.53 1119 Mar 13.40 9.75 11.07 0.68 1204 Apr 14.15 8.88 11.02 1.21 1150 May 15.05 9.43 11.60 1.22 1194 Jun 15.18 9.75 12.26 1.27 1204 Jul 15.48 11.02 13.24 0.94 1316 Aug 16.23 11.82 13.46 0.86 1395 Sep 15.95 10.88 13.11 1.11 1337 Oct 15.25 11.38 13.75 0.79 1338 Nov 14.68 11.90 13.50 0.49 1291 Dec 14.95 10.75 12.87 0.66 1314 Station: SC 1V Jan 13.85 9.07 11.80 0.85 1612 Feb 13.80 9.57 11.29 0.75 1383 Mar 15.35 9.80 11.79 1.06 1490 Apr 17.38 9.05 12.54 1.80 1423 May 18.02 9.68 13.45 2.00 1491 Jun 18.95 9.98 14.13 1.78 1512 Jul 18.67 11.85 15.15 1.37 1644 Aug 18.90 13.15 15.60. 1.13 1666 Sep 19.45 11.20 14.68 1.58 1582 Oct 17.50 11.95 14.44 1.00 1578 Nov 16.55 12.01 13.74 0.77 1525 Dec 15.48 9.10 12.59 1.04 1618 4 k--ESLO2014-02 A-6 Diablo Canyon Power Plant Appendix B Subtidal Temperatures Appendix B -Subtidal Temperatures Table 131. Monthly statistical summary of subtidal temperatures

(°C), January-December 2013, North Control Station NC I -3m (l-10).Month Max Min Mean Std. Dev N Station: NC I -3m Jan 13.57 10.32 11.96 0.71 2232 Feb 12.60 9.80 11.11 0.55 2016 Mar 13.88 9.90 11.19 0.71 2232 Apr 14.25 9.27 11.32 1.24 2160 May 15.13 9.57 11.99 1.33 2231 Jun 15.20 9.60 12.15 1.18 2160 Jul 15.23 11.35 13.53 0.82 2232 Aug 15.57 12.23 13.68 0.66 2232 Sep 16.23 10.82 13.32 1.25 2160 Oct 15.75 11.45 13.85 0.89 2232 Nov 15.00 11.50 13.57 0.62 2160 Dec 15.07 10.38 12.97 0.74 2232 Table B2. Monthly statistical summary of subtidal temperatures

(°C), January-December 2013, Field's Cove Station FC I -3m (22-10).Month Max Min Mean Std. Dev N Station: FC I -3m Jan 14.93 10.77 12.90 0.89 2232 Feb 14.65 9.85 11.42 0.84 2016 Mar 14.68 9.95 11.68 0.85 2232 Apr 15.70 9.00 12.12 1.49 2160 May 16.60 9.70 12.67 1.57 2231 Jun 16.02 10.50 13.06 1.20 2160 Jul 16.42 11.98 14.24 0.88 2232 Aug 16.83 12.73 14.53 0.71 2232 Sep 17.90 11.45 14.22 1.30 2160 Oct 17.27 11.85 14.91 1.13 2231 Nov 17.13 12.50 14.81 0.81 2160 Dec 17.50 12.25 14.32 0.80 2232 031-w ESLO2014-02 B-1 Appendix B -Subtidal Temperatures Table B3. Monthly statistical summary of subtidal temperatures

('C), January-December 2013, North Diablo Cove Stations NDC 2 -3m (8-10), NDC 3 -3m (9-10), and NDC 4 -4m (9-15).Month Max Min Mean Std. Dev N Station: NDC 2 -3m Jan 20.17 10.73 15.96 1.91 2232 Feb 19.23 10.20 14.04 2.30 2016 Mar 20.70 10.85 15.31 1.93 2232 Apr 21.50 9.30 15.27 2.46 2160 May 21.42 10.07 16.11 2.25 2232 Jun 22.05 11.35 16.36 1.96 2160 Jul 21.63 13.15 17.52 1.42 2232 Aug 21.17 14.60 17.77 1.08 2232 Sep 21.15 11.80 17.55 1.65 2160 Oct 22.80 11.95 18.18 1.73 2231 Nov 22.30 13.52 17.99 1.35 2160 Dec 22.38 13.52 17.73 1.41 2232 Station: NDC 3 -3m Jan 21.42 10.73 16.29 1.95 2232 Feb 19.63 10 25 14.76 2.39 2015 Mar 20.55 10.75 15.63 1.97 2232 Apr 21.60 9.40 15.40 2.44 2160 May 21.17 10.07 16.22 2.18 2232 Jun 21.92 11.45 16.39 1.97 2160 Jul 21.83 13.02 17.26 1.49 2232 Aug 21.23 13.98 17.30 1.24 2232 Sep 21.38 11.80 17.33 1.60 2160 Oct 22.98 12.35 18.18 1.78 2231 Nov 22.75 13.63 18.04 1.43 2160 Dec 22.73 13.65 17.86 1.51 2232 Station: NDC 4 -4m Jan 20.27 10.65 15.89 1.90 2232 Feb 18.85 10.15 13.83 2.13 2016 Mar 20.38 10.60 14.78 1.86 2232 Apr 21.48 9.27 14.83 2.37 2160 May 21.05 10.05 15.52 2.10 2232 Jun 21.65 11.23 15.87 1.94 2160 Jul 21.52 12.98 16.48 1.56 2232 Aug 21.17 12.85 16.31 1.49 2232 Sep 20.50 11.73 16.52 1.65 2160 Oct 22.60 12.07 17.42 1.88 2230 Nov 21.95 13.60 17.44 1.45 2160 Dec 22.30 12.98 17.42 1.54 2232 m ESL02014-02 B-2 Appendix B -Subtidal Temperatures Table B4. Monthly statistical summary of subtidal temperatures

(°C), January-December 2013, South Diablo Cove Stations SDC 1 -3m (11-10) and SDC 4 -4m (11-15).Month Max Min Mean Std. Dev N Station: SDC 1 -3m Jan 23.08 11.80 16.03 1.97 2231 Feb 19.13 11.85 14.78 1.35 2016 Mar 19.83 10.98 14.15 1.79 2232 Apr 22.10 10.50 14.77 2.14 2160 May 21.17 11.63 15.44 1.83 2232 Jun 21.55 11.38 15.29 2.08 2160 Jul 21.92 11.93 14.93 1.84 2231 Aug 20.73 11.68 14.70 1.66 2232 Sep 21.05 12.07 15.27 1.70 2160 Oct 22.83 13.10 16.23 1.81 2231 Nov 23.42 12.98 16.09 1.94 2160 Dec 25.20 12.48 16.28 2.38 2232 Station: SDC 4 -4m Jan 21.83 10.95 15.23 2.00 2231 Feb 17.35 11.23 13.88 1.21 2016 Mar 17.30 10.60 13.17 1.53 2232 Apr 20.05 9.57 12.89 2.09 2160 May 18.77 9.93 13.36 1.93 2232 Jun 19.95 9.77 13.11 2.03 2160 Jul 19.75 10.98 13.26 1.34 2232 Aug 18.67 11.25 13.05 0.99 2232 Sep 20.13 11.05 13.66 1.62 2160 Oct 22.35 11.80 14.66 1.65 2231 Nov 21.92 12.00 14.55 1.67 2160 Dec 23.30 1"i.63 14.55 2.02 2232 0MW ESLO2014-02 B-3 Appendix B -Subtidal Temperatures Table B5. Monthly statistical summary of subtidal temperatures

(°C), January-December 2013, South Control Stations SC 1 -3m (19-10) and SC 2 -6m (20-20).Month Max Min Mean Std. Dev N Station: SC 1 -3m Jan 13.95 10.55 11.99 0.63 2232 Feb 12.63 9.8 11.12 0.55 2016 Mar 13.45 9.75 11.13 0.66 2232 Apr 14.27 8.93 11.03 1.21 2160 May 15.07 9.23 11.48 1.24 2231 Jun 15.27 9.73 11.98 1.24 2160 Jul 15.43 11.02 13.03 0.95 2232 Aug 15.23 11.45 13.05 0.68 2232 Sep 15.77 10.88 13.01 1.04 2160 Oct 15.45 11.38 13.81 0.82 2232 Nov 14.85 11.85 13.58 0.51 2160 Dec 15.15 11.05 12.95 0.68 2232 Station: SC 2 -6m Jan 13.75 10.50 11.93 0.62 2227 Feb 12.65 9.85 11.04 0.49 2016 Mar 13.38 9.63 10.90 0.62 2232 Apr 14.00 8.95 10.74 1.13 2160 May 15.07 9.18 11.06 1.25 2231 Jun 14.90 9.40 11.44 1.25 2160 Jul 14.93 10.55 12.49 0.96 2232 Aug 14.95 10.98 12.51 0.71 2231 Sep 15.43 10.70 12.56 0.93 2160 Oct 15.13 11.45 13.65 0.76 2232 Nov 14.77 11.77 13.50 0.51 2159 Dec 14.98 11.48 13.01 0.63 2232 0-- ESLO2014-02 B-4 Diablo Canyon Power Plant Appendix C Intertidal Algae, Invertebrates and Substrates Appendix C -Intertidal Algae, Invertebrates and Substrates Table Cl. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for North Control Station NC 1+0.3m (1+1).Survey 172 173 174 175 Survey Date 21-Feb-13 8-May-13 11-Jul-13 15-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Cover Mazzaella flaccida 18.6 12.9 39.9 13.3 43.1 18.0 11.0 7.9 28.1 Phyllospadixspp.

20.6 20.4 16.8 19.3 18.7 22.0 32.2 32.5 22.0 non-coralline crust 22.8 11.3 19.6 13.7 20.6 17.8 24.9 19.0 22.0 Chondracanthus canaliculatus 12.2 9.1 9.2 5.3 12.5 7.8 7.7 7.7 10.4 Mazzaella affinis 13.3 10.3 13.5 10.6 9.1 9.8 5.1 4.0 10.3 Gastroclonium subarticulatum 10.8 8.2 4.1 8.3 7.4 7.1 8.3 9.4 7.6 Gelidium coulteri 5.1 4.8 4.3 4.5 4.9 3.9 3.4 3.1 4.4 Codium setchellii 2.9 6.5 1.1 1.9 2.3 4.1 6.5 12.0 3.2 coralline crust 1.9 4.0 2.6 4.3 3.1 4.3 2.6 1.9 2.6 Mastocarpus papillatus 2.0 1.9 3.4 3.1 3.7 4.1 1.2 1.4 2.6 filamentous red algae complex 2.6 3.1 3.3 4.4 2.9 3.7 1.0 1.8 2.4 Cryptopleura violacea 1.3 1.0 2.3 2.8 2.4 5.4 0.6 0.9 1.6 Endocladia muricata 1.4 4.4 2.8 4.8 0.8 2.6 0.3 0.9 1.3 Egregia menziesii

<0.1 0.2 --1.4 3.5 3.7 10.9 1.3 Ulva spp. <0.1 <0.1 <0.1 <0.1 3.6 4.6 <0.1 0.2 0.9 Mastocarpusjardinii 0.9 1.4 <0.1 <0.1 2.1 2.3 0.4 0.7 0.9 Prionitis spp. 0.9 2.6 0.6 2.0 0.3 0.9 0.7 1.1 0.6 Corallina vancouveriensis 1.2 2.0 0.5 1.5 0.2 0.7 0.5 1.3 0.6 Calliarthron/Bossiella spp.-complex 0.3 0.6 0.5 1.0 0.2 0.7 0.7 2.0 0.4 Mazzaella leptorhynchos 0.6 1.2 0.2 0.7 0.3 0.8 0.3 0.7 0.4 Porphyraspp.

0.7 1.2 0.3 0.9 <0.1 <0.1 --0.2 Pterosiphonia dendroidea

<0.1 <0.1 ----0.7 1.5 0.2 Gelidium pusillum 0.2 0.5 <0.1 <0.1 --0.4 0.9 0.2 Mazzaella oregona 0.4 0.6 <0.1 <0.1 0.2 0.5 --0.2 Mazzaella splendens


0.2 0.7 0.3 0.9 0.1 juv. articulated coralline algae <0.1 0.2 <0.1 <0.1 0.1 0.4 0.3 0.6 0.1 Callithamnionpikeanum

<0.1 <0.1 <0.1 0.2 0.4 0.9 --0.1 Microcladia coulteri --<0.1 <0.1 0.1 0.4 0.3 0.9 0.1 Osmundeaspp.

0.1 0.4 0.1 0.4 --<0.1 <0.1 <0.1 Corallina chilensis

<0.1 <0.1 0.1 0.4 <0.1 <0.1 0.1 0.4 <0.1 Smithoranaiadum

--<0.1 <0.1 0.2 0.5 <0.1 <0.1 <0.1 Sarcodiotheca gaudichaudii

<0.1 0.2 0.1 0.4 <0.1 <0.1 <0.1 <0.1 <0.1 Halymenia/Schizymenia spp.-complex


0.1 0.4 <0.1 Cladophora spp. <0.1 0.2 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Grateloupia californica

<0.1 0.2 ------<0.1 Chlorophyta (filamentous)

--<0.1 <0.1 <0.1 Cystoseira osmundacea

<0.1 <0.1 --<0.1 Microcladia borealis --<0.1 <0.1 <0.1 Melobesia mediocris

--<0.1 <0.1 <0.1 Invertebrate Counts Ch/orostoma funebralis 33.8 27.1 6.4 8.1 3.8 4.8 12.8 15.7 14.2 Pagurus spp. 12.8 4.4 9.6 8.0 5.6 6.0 17.4 9.8 11.4 Tetraclita rubescens 5.2 11.6 ----6.0 13.4 2.8 Chlorostoma brunnea 1.8 3.5 1.2 1.6 0.8 1.3 0.6 0.9 1.1 (table continued)

W ESL02014-02 C-1 Appendix C -Intertidal Algae, Invertebrates and Substrates Table Cl (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for North Control Station NC +0.3m (1+1).Survey 172 173 174 175 Survey Date 21-Feb-13 8-May-13 11-Jul-13 15-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Leptasterias spp.Pachygrapsus crassipes Nemertea Pugettia spp.Anthopleura elegantissima Ocinebrina spp.Lottia scabra Fissurella volcano Epiactis prolifera Serpulorbis squamigerus Pseudomelatoma torosa Lacuna spp.Alia spp.Crepidula spp.Lottiidae Lirobittium spp.Heptacarpus spp.Lissothuria nutriens Grapsidae Lottia instabilis Pycnogonida Petrolisthes spp.Phidiana hi/toni Ischnochitonidae Barleeia spp.Homolo. luridum/Lirulafia succincta 0.8 1.8 0.2 0.4 0.4 0.5 0.2 0.4 0.6 1.3 0.2 0.4<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 6.5 10.9<0.1 0.2 0.2 0.7<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 3.8 4.6 3.0 4.0 0.8 1.4 0.6 0.9 1.2 2.7 0.4 0.5 0.6 0.5<0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 0.2 0.2 0.4<0.1 0.2 0.2 0.2<0.1<0.1<0.1<0.1<0.1 5.3 0.1<0.1<0.1<0.1<0.1<0.1 4.9 2.1 0.1 0.4 0.4 0.9<0.1 0.4 0.4 0.4<0.1<0.1<0.1<0.1<0.1 4.1 0.3<0.1<0.1<0.1<0.1<0.1 4.1 2.4 0.4 1.0 0.2 0.4 0.2 0.4 0.2 0.2 0.2<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 28.5 1.2 0.7<0.1<0.1i<0.1<0.1<0.1<0.1 1.0 0.4 0.5 0.4 0.5 0.4 0.4 0.4<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 20.6 2.9 1.4 0.2 0.2<0.1<0.1<0.1 0.7 0.4 0.4 0.3 0.2 0.2 0.1 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 11.2 0.4 0.2<0.1<0.1<0.1<0.1<0.1<0.1 6.0 4.4 0.4 Invertebrate Cover Pista spp.tunicates, compound/social Phragmatopoma califomica bryozoa (encrusting)

Porifera (encrusting)

Spirorbidae Salmacina tribranchiata Chthamalus fissus Haliclona spp.Substrate Cover sand (shell gravel)rock cobble 4.5<0.1<0.1<0.1<0.1<0.1<0.1<0.1 6.0 11.2 0.5 4.4<0.1<0.1<0.1<0.1<0.1<0.1<0.1 4.5 11.5 1.0 9.4 7.7 1.3 1.9<0.1 0.2 WOWESLO2014-02C-C-2 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C2. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for North Control Station NC 1+0.9m (1+3).Survey 172 173 174 175 Survey Date 21-Feb-13 8-May-13 11-Jul-13 15-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Cover Endocladia muricata Mazzaella flaccida Mastocarpus papillatus non-coralline crust coralline crust Silvetia compressa Codium setchellii Gelidium coulteri Mazzaella affinis Mastocarpus jardinhi Gelidium pusillum Phyllospadix spp.Chondracanthus canaliculatus Cryptopleura violacea Corallina vancouveriensis juv. articulated coralline algae Prionitis spp.Ulva spp.Porphyra spp.filamentous red algae complex Analipus japonicus Gastrocloniurn subarticulatum Mazzaella oregona Calliarthron/Bossiella spp.-complex Mazzaella leptorhynchos Corallina chilensis Cladophora spp.Callithamnion pikeanum Smithora naiadurn Neorhodomela larix Melobesia mediocris Invertebrate Counts Chlorostoma funebralis Pagurus spp.Pol/icipes polymerus Lottia scabra Lottia limatula Tetraclita nibescens Nuttallina califomica Pachygrapsus crassipes Anthopleura elegantissima Lottia scutum Fissurella volcano Mooalia son.28.1 22.8 18.7 23.7 10.6 4.4 3.9 3.0 2.7 1.9 1.7 0.4 1.5 1.5 0.6<0.1 0.2<0.1<0.1 0.1<0.1 0.3<0.1<0.1<0.1<0.1 54.0 7.8 6.4 3.8 2.4 0.6 1.6 0.6 0.4 0.2 0.4 19.1 11.9 8.0 9.4 11.5 9.2 8.3 1.7 4.6 2.7 1.6 1.3 1.8 3.0 1.1<0.1 0.5<0.1<0.1 0.4<0.1 0.9<0.1 0.2<0.1 61.2 13.8 14.3 6.5 4.8 1.3 2.3 0.5 0.5 0.4 0.5 26.1 20.4 26.7 16.3 27.2 14.1 17.2 9.5 4.2 3.0 6.6 15.3 1.7 4.2 1.9 2.7 1.6 4.8 1.5 2.2 0.3 0.9<0.1 <0.1 0.2 0.5 1.1 2.6 0.5 0.9<0.1 0.2 0.1 0.3<0.1 <0.1 0.6 1.2<0.1 0.2<0.1 <0.1<0.1 <0.1<0.1 <0.1 40.4 35.7 11.6 13.5 3.6 8.0 0.8 1.3 2.6 5.3 0.8 1.8 1.2 1.8 1.0 1.0 0.4 0.9 23.7 28.7 32.1 14.9 7.0 5.6 3.4 2.1 1.4 1.0 0.5 1.0 0.1<0.1<0.1 0.2<0.1 0.2 0.3 0.2 0.2<0.1 0.1<0.1<0.1<0.1<0.1 27.8 3.0 6.0 3.0 1.2 4.6 0.4 0.2 0.6 0.4 0.2 0.4 16.2 20.8 14.7 11.4 6.7 11.9 7.8 3.6 1.6 1.7 0.7 2.2 0.4<0.1 0.2 0.7<0.1 0.7 0.7 0.7 0.7<0.1 0.4<0.1<0.1<0.1 6.4 3.7 13.4 4.2 2.2 6.3 0.9 0.4 1.3 0.5 0.4 0.5 21.8 14.4 13.7 26.9 13.7 5.6 3.3 5.0 1.1 1.9 2.5 1.7 1.0 0.3 1.1 0.7 0.6 0.6 0.6 0.2 0.6 0.1<0.1<0.1<0.1<0.1 15.4 6.2 5.0 0.2 1.2 0.8 0.2 0.8 0.2 0.6 16.6 10.9 8.7 10.3 7.2 11.8 7.1 6.7 2.1 2.5 3.2 4.1 1.0 0.9 1.4 1.0 1.2 2.0 2.0 0.7 1.3 0.4 0.2 0.2<0.1<0.1 10.5 7.2 11.2 0.4 0.8 1.3 0.4 0.4 0.4 0.5 24.9 23.1 22.9 20.7 8.9 5.6 3.1 3.0 1.7 1.6 1.3 0.8 0.7 0.7 0.6 0.2 0.2 0.2 0.2 0.2 0.2 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 34.4 7.2 5.3 2.0 1.9 1.5 1.0 0.5 0.5 0.3 0.2 0.2 (table continued) 0EW-ESLO2014-02 C-3 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C2 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for North Control Station NC 1+0.9!n (1+3).Survey 172 173 174 175 Survey Date 21-Feb-13 8-May-13 11-Ju1-13 15-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continuedl Leptasterias spp. --0.2 0.4 0.4 0.5 --0.2 Ocinebrina spp. 0.2 0.4 --0.2 0.4 0.2 0.4 0.2 Pugettia spp. 0.2 0.4 0.2 0.4 --0.2 0.4 0.2 Hemigrapsus nudus 0.6 0.9 ------0.2 Haliotis spp. 0.1 0.3 0.1 0.3 0.1 0.3 0.1 0.3 0.1 Epiactis prolifera


0.2 0.4 --<0.1 Acanthinucella spp. --0.2 0.4 <0.1 Lottia pefta 0.2 0.4 <0.1 Chlorostoma brunnea 0.2 0.4 <0.1 Lottiidae

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Crepidula spp. <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Lacuna spp. <0.1 <0.1 ----<0.1 <0.1 <0.1 Barleeia spp. ----<0.1 <0.1 <0.1 Mytilus spp. <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Sipuncula

--<0.1 <0.1 <0.1 <0.1 <0.1 Grapsidae

<0.1 <0.1 <0.1 <0.1 -<0.1 Cyanoplaxspp.

--<0.1 <0.1 -<0.1 Aliaspp. <0.1 <0.1 <0.1 Ischnochitonidae

<0.1 <0.1 <0.1 Lirobittium spp. <0.1 <0.1 <0.1 Homolo. luridum/Urularia succincta

--<0.1 <0.1 --<0.1 Invertebrate Cover Phragmatopomacalifomica 0.3 0.8 <0.1 <0.1 <0.1 <0.1 0.3 1.1 0.2 Spirorbidae

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Chthamalus fissus <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 tunicates, compound/social

<0.1 <0.1 ---<0.1 <0.1 <0.1 Porifera (encrusting)

-- <0.1 <0.1 <0.1 Salmacina tribranchiata

<0.1 <0.1 <0.1 <0.1 <0.1 bryozoa (encrusting)

-<0.1 <0.1 <0.1 Pista spp. --<0.1 <0.1 <0.1 Substrate Cover rock 6.5 6.0 18.5 15.6 7.8 4.2 6.7 7.1 9.9 cobble 1.0 2.3 1.9 5.9 0.7 2.2 2.0 2.9 1.4 sand (shell gravel) 0.3 0.7 <0.1 <0.1 0.2 0.5 0.6 1.2 0.3 MEW 4 ESL02014-02 C-4 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C3. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m 2) survey means, standard deviations and 2013 annual means for North Control Station NC 2+0.3m (2+1).Survey 172 173 174 175 Survey Date 26-Feb-13 29-May-1 3 6-Aug-13 13-Dec-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Cover Mazzaella flaccida non-coralline crust Chondracanthus canaliculatus Phyllospadix spp.Egregia menziesii Mazzaella affinis Gastroclonium subarticulatum Mastocarpus papillatus Codium setchellii Gelidium coulteri coralline crust filamentous red algae complex Mastocarpus jardinii Neorhodomela larix Ulva spp.Smithora naiadum Porphyra spp.Cryptopleura violacea Mazzablla oregona Mazzaella leptorhynchos Prionitis spp.24.1 19.2 17.1 14.5 1.4 10.2 6.1 10.1 16.5 3.9 Corallina vancouveriensis Gelidium pusillum Microcladia coulteri Mazzaella splendens Laminaria setchellii Calliarthron/Bossiella spp.-complex juv. articulated coralline algae Pterosiphonia dendroidea Endocladia muricata Acrosiphonia spp.Cryptosiphonia woodii Osmundea spp.Gelidium spp.Cladophora spp.Soranthera ulvoidea Corallina chilensis Sarcodiotheca gaudichaudii Melobesia mediocris Callithamnion pikeanum Microcladia borealis Chondracanthus corvmbiferus 15.1 6.6 6.7 8.5 4.0 4.0 4.4 7.8 1.7 2.0 3.4 5.4 6.5 6.9 1.0 2.1 2.6 5.5 0.1 0.3<0.1 <0.1 0.7 1.8 0.3 0.9 1.0 1.5 0.6 1.1 0.8 2.2 0.1 0.4<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 36.5 14.1 22.4 13.8 21.7 9.9 14.2 10.3 9.5 12.4 7.4 5.9 5.0 6.7 3.3 2.7 3.2 6.1 4.2 2.6 2.3 2.0 1.2 2.6 2.4 3.7 2.4 4.5 1.7 2.5 0.2 0.5 2.5 5.9<0.1 0.2 1.1 1.8 0.8 1.9 0.1 0.4<0.1 0.2<0.1 0.2 0.3 0.7 0.3 0.9<0.1 <0.1<0.1 0.2<0.1 0.2<0.1 0.2<0.1 0.2<0.1 0.2<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 23.4 11.0 19.8 16.9 24.3 4.3 7.1 3.5 2.5 5.3 4.9 0.3 2.6 0.3 3.1 4.2 1.2 2.0<0.1 0.3<0.1 0.3<0.1<0.1 0.3 0.2<0.1<0.1<0.1<0.1<0.1<0.1<0.1 5.4 11.1 12.7 13.6 24.8 3.9 7.5 4.6 4.6 6.0 7.8 0.9 4.6 0.7 3.9 4.0 3.2 2.3<0.1 0.6<0.1 0.8<0.1<0.1 0.9 0.5<0.1<0.1<0.1<0.1<0.1<0.1<0.1 8.4 4.9 21.4 11.8 13.0 10.8 18.1 18.6 1.0 1.6 6.4 5.4 7.0 6.6 4.9 6.6 3.8 5.3 1.7 1.7 1.3 1.5 1.4 3.4 2.0 2.9 0.2 0.7 0.3 0.4<0.1 <0.1 1.0 1.4 0.2 0.5 0.6 1.3<0.1 0.2 0.2 0.7<0.1<0.1 <0.1<0.1 0.2<0.1 0.2<0.1 <0.1<0.1 <0.1<0.1 <0.1 23.1 18.5 17.9 15.9 9.0 8.3 6.5 3.9 3.5 3.2 3.0 2.4 2.0 1.4 1.3 1.1 0.9 0.7 0.6 0.6 0.3 0.3 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 (table continued) f/wM-WESLO2014-02 C-5 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C3 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for North Control Station NC 2+0.3m (24-1).Survey 172 173 174 175 Survey Date 26-Feb-13 29-May-13 6-Aug-13 13-Dec-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts Pagurus spp. 7.8 6.6 11.2 9.0 5.4 3.8 5.0 5.7 7.4 Chlorostoma funebralis 13.2 7.3 5.0 5.0 4.2 4.8 2.2 1.8 6.2 Chlorostoma brunnea 2.2 2.7 3.2 2.6 1.6 2.1 12.2 24.5 4.8 Anthopleura elegantissima 3.6 6.4 5.2 11.1 3.4 7.1 3.0 3.2 3.8 Tetraclita rubescens 1.4 2.6 2.4 5.4 --2.4 3.3 1.6 Epiactis prolifera 0.8 0.8 --0.2 0.4 4.6 6.1 1.4 Lottia pelta 0.8 1.8 0.4 0.9 1.2 2.7 1.2 2.2 0.9 Lottia scutum 0.6 0.9 1.0 1.7 1.2 1.3 0.4 0.9 0.8 Leptasterias spp. 0.2 0.4 0.4 0.9 1.2 1.8 0.4 0.5 0.6 Romaleon antennarius


1.8 3.5 --0.5 Fissurella volcano ----0.4 0.9 1.2 0.8 0.4 Lottia limatula 0.8 1.1 0.2 0.4 --0.4 0.9 0.4 Nemertea --0.6 0.5 0.6 0.5 --0.3 Pugettia spp. 0.4 0.5 -0.2 0.4 0.2 Lottia scabra --0.2 0.4 0.2 0.4 --0.1 Acanthinucella spp. ----0.2 0.4 <0.1 Mopalia spp. --0.2 0.4 <0.1 Nereididae 0.2 0.4 --<0.1 Pisaster ochraceus

--0.2 0.4 <0.1 Crepidulaspp.

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Lacuna spp. <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 --<0.1 Lottiidae

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Ischnochitonidae

--<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Alia spp. --<0.1 <0.1 <0.1 <0.1 <0.1 Pycnogonida

<0.1 <0.1 <0.1 <0.1 --<0.1 Cyanoplaxspp.

--<0jI <0.1 <0.1 <0.1 <0.1 Lottia insessa <0.1 <0.1 <0.1 <0.1 ----<0.1 Phidiana hi/toni ----<0.1 <0.1 <0.1 Lirobittium spp. ----<0.1 <0.1 <0.1 Invertebrate Cover Pista spp. 3.8 5.3 14.8 10.2 6.0 4.9 16.8 9.4 10.3 Porifera (encrusting)

<0.1 <0.1 <0.1 <0.1 <0.1 0.2 <0.1 <0.1 <0.1 Phragmatopoma califomica

<0.1 -<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Spirorbidae

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 tunicates, compound/social

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 bryozoa (encrusting)

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Chthamalus fissus <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Salmacina tribranchiata

<0.1 <0.1 ------<0.1 Substrate Cover sand (shell gravel) 3.3 3.1 4.9 4.7 19.5 18.3 2.6 2.2 7.6 rock 3.1 3.4 6.9 5.9 6.5 6.1 4.5 5.0 5.2 cobble 2.4 3.5 0.8 1.3 0.3 1.1 5.1 8.8 2.2 mm-- ESL02014-02 C-6 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C4. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for North Control Station NC 2+0.9m (2+3).Survey 172 173 174 175 Survey Date 26-Fe Sd13 29-May-13 6-Aug-13 13-Dec-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Cover Endocladiamuricata 41.0 21.3 40.6 23.7 29.4 17.1 34.7 21.1 36.4 Mastocarpus papillatus 14.2 7.7 24.5 11.6 21.0 8.1 16.7 8.0 19.1 non-coralline crust 21.4 8.8 16.6 6.9 15.5 7.5 22.8 10.8 19.1 Mazzaella flaccida 11.7 11.2 16.5 11.5 17.9 9.7 5.3 5.8 12.9 Mazzaella affinis 7.3 6.5 9.6 9.3 4.2 4.6 6.8 6.3 7.0 coralline crust 5.3 8.0 1.0 1.4 2.6 4.0 8.7 7.9 4.4 Mastocarpusjardinii 1.7 1.7 1.9 2.7 3.2 6.9 2.1 3.1 2.2 Gelidium coulteri 1.5 1.4 1.0 1.3 2.1 3.9 1.8 2.3 1.6 Chondracanthus canaliculatus 0.6 1.3 0.4 0.9 1.6 5.1 0.8 1.7 0.9 Gastroclonium subarticulatum

<0.1 0.2 --1.1 3.5 0.6 1.5 0.4 Silvetia compressa 0.2 0.7 0.4 1.3 0,2 0.7 0,2 0.7 0.3 Gelidiumpusillum 0.3 0.5 0.1 0.3 <0.1 0.2 0.1 0.4 0.2 Mazzaella oregona <0.1 0.2 0.6 1.5 <0.1 <0.1 <0.1 <0.1 0.2 Corallina vancouveriensis

<0.1 <0.1 <0.1 0.2 0.1 0.4 0.5 1.0 0.2 Calliarthron/Bossiella spp.-complex

<0.1 <0.1 --0.4 1.3 0.1 0.4 0.1 Fucus gardneri <0.1 <0.1 <0.1 0.2 0.1 0.4 <0.1 0.2 <0.1 juv. articulated coralline algae <0.1 0.2 <0.1 <0.1 <0.1 <0.1 <0.1 0.2 <0.1 Porphyra spp. --<0.1 0.2 <0.1 0.2 --<0.1 Cryptopleura violacea 0.1 0.4 --<0.1 <0.1 -<0.1 Cladophora spp. <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Ulvaspp. <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 --<0.1 Mazzaella leptorhynchos

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Prionitis spp. <0.1 <0.1 <0.1 <0.1 --<0.1 <0.1 <0.1 Osmundea spp. ------<0.1 <0.1 <0.1 Invertebrate Counts Ch/orostoma funebralis 76.6 42.6 216.2 208.0 66.4 21.6 104.4 83.9 115.9 Anthopleura elegantissima 21.6 23.3 20.6 26.7 7.8 10.0 7.2 5.2 14.3 Pagurus spp. 9.2 8.2 14.8 13.3 9.6 9.0 11.0 8.9 11.2 Lottia scabra 4.8 4.3 4.6 7.1 3.4 2.7 1.4 2.1 3.6 Lottia scutum 1.4 1.7 1.8 1.3 1.2 1.8 1.0 0.7 1.4 Lottia limatula 0.4 0.9 1.8 2.2 2.0 2.1 0.8 0.8 1.3 Ocinebrina spp. 1.8 2.2 1.0 1.4 0.6 1.3 0.4 0.9 1.0 Tetraclita rubescens

--2.4 5.4 0.4 0.9 --0.7 Lottia pelta 0.4 0.9 0.2 0.4 --1.6 3.0 0.6 Pachygrapsus crassipes 0.2 0.4 0.6 0.9 0.2 0.4 --0.3 Leptasterias spp. --0.4 0.5 0.4 0.9 0.2 0.4 0.3 Nemertea --0.4 0.9 0.4 0.5 --0.2 Acanthinucella spp. 0.4 0.9 ----0.2 0.4 0.2 Hemigrapsus nudus 0.2 0.4 --0.2 0.4 --0.1 Lottiidae

<0.1 -0.2 0.4 <0.1 <0.1 <0.1 -<0.1 Cyanoplaxspp.


0.2 0.4 <0.1 Mopalia spp. 0.2 0.4 --<0.1 Pisaster ochraceus 0.2 0.4 -I <0.1 (table continued)

W- ESL02014-02 C-7 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C4 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m 2) survey means, standard deviations and 2013 annual means for North Control Station NC 2+0.9m (2+3).Survey 172 173 174 175 Survey Date 26-Feb-13 29-May-13 6-Aug-13 13-Dec-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Serpulidae

--0.2 0.4 --<0.1 Littorinaspp.

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Crepidula spp. <0.1 <0.1 <0.1 <0.1 --<0.1 Ischnochitonidae

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Grapsidae

--<0.1 <0.1 <0.1 Lirobittiurn spp. <0.1 <0.1 --<0.1 Lacuna spp. ----<0.1 <0.1 <0.1 Barleeia spp. <0.1 <0.1 --<0.1 Pachycheles spp. <0.1 <0.1 --<0.1 Invertebrate Cover Phragmatopoma califomica

<0.1 -<0.1 <0.1 0.1 0.4 <0.1 0.2 <0.1 Chtharnalus fissus <0.1 <0.1 <0.1 <0.1 0.1 0.3 <0.1 -<0.1 tunicates, compound/social

--<0.1 <0.1 0.1 0.4 <0.1 <0.1 <0.1 Porifera (encrusting)

--<0.1 <0.1 <0.1 <0.1 <0.1 0.2 <0.1 Spirorbidae

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 -<0.1 bryozoa (encrusting)

--<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Haliclona spp. <0.1 <0.1 <0.1 <0i ---<0.1 Salmacina tribranchiata

<0.1 <0.1 --<0.1 <0.1 -<0.1 Substrate Cover rock 5.7 6.6 4.9 4.6 13.1 3.9 10.7 7.8 8.6 cobble 8.4 7.0 8.1 10.5 5.3 6.7 11.1 11.6 8.2 sand (shell gravel) 0.7 1.8 0.4 1.1 <0.1 <0.1 0.5 1.5 0.4 0f MM0"ESLO2014-02 C-8 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C5. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for Field's Cove Station FC 1+0.3m (4+1).Survey 172 173 174 175 Survey Date 8-Mar-13 12-Apr-13 10-Jul-13 20-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Cover non-coralline crust Mazzaella flaccida Gastroclonium subarticulatum Phyllospadix spp.coralline crust Chondracanthus canaliculatus Cryptopleura violacea Egregia menziesii Endocladia muricata Mastocarpus papillatus Gelidium coulteri Corallina vancouveriensis Mazzaella affinis Prionitis spp.Mastocarpus jardinii juv. articulated coralline algae Calliarthron/Bossiella spp.-complex Mazzaella oregona Cryptosiphonia woodii Gelidium pusillum Porphyra spp.Callithamnion pikeanum Mazzaella splendens Cladophora spp.Ulva spp.Microcladia coulteri Mazzaella leptorhynchos Melobesia mediocrns Osmundea spp.Sarcodiotheca gaudichaudii Halymenia/Schizymenia spp.-complex Pterosiphonia dendroidea Laminaria setchellii Halosaccion americanum Microcladia borealis Grateloupia californica Smithora naiadum Laminariales Invertebrate Counts Chlorostoma funebralis Tetraclita rubescens Pagurus spp.Chlorostoma brunnea Fissurella volcano 26.7 18.1 20.1 10.7 6.9 8.1 12.8 1.3 4.4 3.5 3.6 6.4 3.4 2.3 1.7 1.7 0.5 0.1 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 87.2 32.2 11.8 2.0 4.0 5.4 7.2 6.7 12.5 4.0 6.0 8.6 4.2 6.0 3.5 1.8 5.5 7.0 2.7 3.1 1.3 0.8 0.3 0.3 0.2<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 49.3 49.7 8.3 1.7 2.1 19.7 5.0 24.6 13.3 18.5 11.0 11.0 11.0 5.4 4.9 6.5 4.0 4.0 2.8 1.7 4.8 7.8 11.6 7.1 5.9 2.8 3.0 3.6 4.8 3.7 5.7 2.4 4.9 0.9 1.0 1.3 1.2<0.1 0.2 0.1 0.3 0.7 0.9<0.1 0.2 0.2 0.5<0.1 0.2<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 22.8 14.5 34.6 14.2 20.4 13.7 10.6 12.3 4.8 5.1 10.2 5.8 8.5 6.6 15.8 15.6 5.6 7.9 7.3 8.4 8.0 8.4 0.3 0.5 3.6 6.0 0.2 0.5 1.0 1.5 0.3 0.6 0.5 1.1 0.3 0.5<0.1 <0.1<0.1 0.2 0.1 0.3<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 5.4 7.6 12.8 22.5 1.2 1.1 13.6 16.5 3.0 2.5 28.2 13.7 11.9 9.3 16.8 8.0 13.9 17.7 14.6 8.4 6.0 7.3 4.7 4.7 11.0 10.3 5.6 9.2 2.2 3.3 4.9 3.8 5.6 4.3 4.2 5.0 0.8 1.1 0.8 1.0 0.8 0.8 0.1 0.3 0.2 0.7 0.2 0.7<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 24.3 22.3 19.0 11.5 7.9 7.7 7.5 7.5 5.9 5.0 4.8 4.0 3.7 1.4 1.1 1.0 0.3 0.2 0.2<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 35.8 29.4 7.4 5.7 3.1 48.8 10.0 0.8 1.2 1.0 28.3 16.5 1.3 1.6 2.2 1.6 62.6 15.6 5.8 4.4 3.0 133.9 6.4 7.2 1.7 (table continued)

MOW--P' ES LO2014-02 C-9 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C5 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for Field's Cove Station FC 1+0.3m (4+1).Survey 172 173 174 175 Survey Date 8-Mar-13 12-Apr-13 10-JuA-13 20-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Anthopleura elegantissima Strongylocentrotus purpuratus Epiactis prolifera Pachygrapsus crassipes Nuttallina califomica Lottia scutum Ocinebrina spp.Leptasterias spp.Lottia limatula Nemertea Lottia scabra Caprellidea Serpulorbis squamigerus Lottia pelta Pugettia spp.Serpulidae

" Romaleon antennarius Mitra idae Pseudomelatoma torosa Hemigrapsus nudus Phidiana hiltoni Pelecypoda boring Pisaster giganteus Platyhelminthes Lottiidae Lacuna spp.Crepidula spp.Sipuncula Alia spp.Grapsidae Lirobittium spp.Pisaster/Henricia spp. juv.)Acmaea mitra Heptacarpus spp.Lissothuria nutriens Homolo. luridunm/irulaia succincta Invertebrate Cover Pista spp.tunicates, compound/social Phragmatopoma califomica Spirorbidae Chthamalus fissus Porifera (encrustinq) 4.4 3.6 4.0 4.6 2.0 2.9 2.0 1.2 1.2 1.8 0.6 0.5 1.0 1.7 0.2 0.4 0.4 0.5 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4<0.1 <0.1 0.2 0.4 0.2 0.4<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1.3.2 2.3 1.4 1.7 1.2 1.6 0.6 0.9 1.2 2.2 1.0 1.0 0.8 0.8 0.4 0.5 0.4 0.9 0.2 0.4<0.1 <0.1<0.1 <0.1<0.1 <0.1 0.6 1.1<0.1 <0.1<0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 1.4 0.9 1.6 1.5 2.2 2.9 0.4 0.5 0.2 0.4 1.0 1.7 0.4 0.5 0.4 0.9 0.6 0.9 0.4 0.9 0.8 1.3 0.2 0.4<0.1 <0.1<0.1 <0.1 0.4 0.5 0.2 0.4<0.1 <0.1<0.1 <0.1<0.1 <0.'1<0.1 <0.1<0.1 <0.1<0.1 <0.1 2.6 1.8 1.0 1.8 1.2 0.4 0.6 1.4 0.8 0.4 0.4 0.6<0.1 0.4 0.4 0.2 0.2 0.2 0.2<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 3.2 0.8 0.4<0.1<0.1<0.1 1.8 2.0 1.2 2.5 2.2 0.5 0.9 1.1 0.8 0.9 0.9 0.9<0.1 0.9 0.5 0.4 0.4 0.4 0.4<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 7.8 1.2 1.1<0.1<0.1<0.1 2.9 2.2 1.6 1.2 1.0 0.8 0.7 0.5 0.5 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 1.7 0.4 0.2<0.1<0.1<0.1 1.0<0.1 0.2<0.1<0.1<0.1 1.6<0.1 0.7<0.1<0.1 2.2 5.9 0.6 2.0<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 (table continued)

%N-'ESLO2014-02 C-10 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C5 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m 2) survey means, standard deviations and 2013 annual means for Field's Cove Station FC 1+0.3m (4+1).Survey 172 173 174 175 Survey Date 8-Mar-13 12-Apr-13 10-Jul-13 20-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Cover (continued) bryozoa (encrusting)

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Salmacina tribranchiata


<0.1 <0.1 <0.1 Substrate Cover rock 3.7 5.4 2.9 1.8 4.8 4.2 2.0 1.1 3.4 sand (shell gravel) 1.2 2.2 1.7 3.9 --1.3 2.5 1.1 cobble 0.4 0.9 <0.1 <0.1 -0.3 0.9 0.2 wx--WESLO2014-02 C-11 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C6. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for Field's Cove Station FC 1+0.9m (4+3).Survey 172 173 174 175 Survey Date 24-Jan-13 13-Jun-13 18-Sep-13 20-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Cover Endocladia muricata 33.7 18.5 38.1 22.1 37.8 27.7 35.1 23.6 36.2 non-coralline crust 28.0 11.8 19.5 11.8 26.2 12.3 22.9 13.5 24.2 Mastocarpus papillatus 5.6 4.2 11.5 8.5 10.5 4.4 7.8 7.9 8.9 Mazzaella flaccida 0.4 0.7 3.3 7.0 5.6 6.1 0.5 1.0 2.4 Gelidium coulteri 0.6 1.2 1.2 1.7 4.8 6.3 1.7 2.3 2.0 coralline crust 2.4 2.2 1.1 1.6 1.9 5.0 1.8 3.8 1.8 Calliarthron/Bossiella spp.-complex 0.6 2.0 0.5 1.5 0.6 2.0 0.8 2.6 0.6 Corallina vancouveriensis 1.0 1.5 0.3 0.9 0.3 0.9 0.5 0.9 0.5 Phyllospadixspp.

0.3 0.6 0.3 0.8 0.9 2.1 0.5 1.0 0.5 Mastocarpusjardinii


1.9 2.1 <0.1 0.2 0.5 Prionitis spp. 0.1 0.4 0.2 0.5 0.3 1.1 0.3 0.8 0.3 Gelidiumpusillum

<0.1 -0.3 0.7 <0.1 0.2 0.3 0.7 0.2 Silvetia compressa 0.1 0.4 0.2 0.7 --0.2 0.7 0.1 Mazzaella leptorhynchos

--<0.1 <0.1 0.5 1.0 <0.1 <0.1 0.1 juv. articulated coralline algae 0.2 0.5 <0.1 <0.1 <0.1 <0.1 0.2 0.5 0.1 Mazzaella oregona <0.1 <0.1 <0.1 <0.1 0.3 0.6 <0.1 0.2 0.1 Mazzaella affinis 0.1 0.4 --0.2 0.5 <0.1 <0.1 <0.1 Cryptosiphonia woodii --0.3 0.9 ----<0.1 Chondracanthus canaliculatus

<0.1 <0.1 <0.1 <0.1 0.2 0.5 <0.1 <0.1 <0.1 Cladophoraspp.

<0.1 <0.1 <0.1 -<0.1 0.2 <0.1 <0.1 <0.1 Porphyra spp. <0.1 <0.1 <0.1 <0.1 <0.1 0.2 <0.1 <0.1 <0.1 Criptopleura violacea <0.1 <0.1 -<0.1 0.2 --<0.1 Callithamnion pikeanum --<0.1 <0.1 ----<0.1 Invertebrate Counts Anthopleura e/egantissima 301.8 204.6 375.4 335.2 225.2 280.3 392.4 419.8 323.7 Chiorostoma funebralis 195.4 100.0 152.4 104.7 170.0 43.7 289.6 108.7 201.9 Lottia scabra 13.8 21.8 36.0 43.9 43.0 65.0 25.6 30.3 29.6 Pagurusspp.

39.0 15.5 19.2 9.7 17.4 15.0 31,8 15.1 26.9 Lottia limatula 1.6 2.1 4.2 4.6 20.0 28.5 4.6 4.7 7.6 Pachygrapsus crassipes 0.6 0.9 1.6 1.3 1.6 1.1 3.0 2.0 1.7 Acanthinucella spp. 2.8 2.7 0.6 0.5 0.2 0.4 2.2 1.5 1.5 Lottia scutum 0.8 0.8 1.8 1.9 0.6 0.9 0.2 0.4 0.9 Ocinebrina spp. 1.2 1.8 0.6 0.9 0.2 0.4 1.2 0.8 0.8 Lottia pefta 0.6 0.9 --0.4 0.9 1.8 0.8 0.7 Cyanoplax spp. 0.2 0.4 0.4 0.9 0.6 0.9 0.2 0.4 0.4 Pisaster ochraceus

--0.2 0.4 0.8 1.3 0.4 0.5 0.4 CirratulidaefTerebellidae


1.0 2.2 0.3 Nemertea 0.2 0.4 0.2 0.4 0.4 0.5 0.2 Hemigrapsus nudus 0.8 1.3 ----0.2 Haliotis spp. 0.1 0.3 0.1 0.3 0.1 0.3 0.2 0.6 0.1 Mopalia spp. --0.2 0.4 --0.2 0.4 0.1 Lottiidae

<0.1 <0.1 -0.2 0.4 <0.1 <0.1 Epiactis prolifera

--0.2 0.4 -<0.1 Fissurella volcano 0.2 0.4 --<0.1 (table continued)

N ESL02014-02 C-12 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C6 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for Field's Cove Station FC 1+0.9m (4+3).Survey 172 173 174 175 Survey Date 24-Jan-13 13-Jun-13 18-Sep-13 20-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Chlorostoma brunnea 0.2 0.4 --<0.1 Tonicella lineata ----0.2 0.4 <0.1 Serpulidae

--0.2 0.4 --<0.1 Littorinaspp.

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Grapsidae

--<0.1 <0.1 <0.1 <0.1 <0.1 Epitoniurn/Opaliaspp.

<0.1 <0.1 <0.1 <0.1 <0.1 Sipuncula

<0.1 <0.1 --<0.1 <0.1 <0.1 Crepidulaspp.

<0.1 <0.1 ------<0.1 Ischnochitonidae

--<0.1 <0.1 <0.1 Majidae <0.1 <0.1 <0.1 Pugettia spp. -<0.1 <0.1 <0.1 Platyhelminthes

--<0.1 <0.1 <0.1 Barleeiaspp.

<0.1 <0.1 --<0.1 Eupentacta quinquesemita

--<0.1 <0.1 --<0.1 Invertebrate Cover Phragmatopoma califomica 1.3 2.1 0.6. 1.2 1.8 3.2 3.3 4.2 1.8 Chthamalus fissus 0.3 0.6 0.1 0.4 0.2 0.5 0.3 0.9 0.2 Spirorbidae

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Haliclona spp. ------<0.1 <0.1 <0.1 Substrate Cover rock 21.0 9.1 23.4 15.0 14.8 7.2 20.8 11.9 20.0 cobble 2.0 3.9 2.1 3.2 3.3 5.2 2.8 4.7 2.6 sand (shell gravel) 2.9 4.1 0.6 1.2 1.5 2.6 1.3 3.0 1.6 C-13 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C7. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m:) survey means, standard deviations and 2013 annual means for Field's Cove Station FC 2+0.3m (5+ 1).Survey 172 173 174 175 Survey Date 7-Mar.13 12-Apr.13 10-Jul-13 7-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Cover non-coralline crust 27.4 7.6 20.3 11.0 23.7 11.3 33.0 11.5 26.1 Mazzaella flaccida 11.2 8.1 18.7 12.1 26.0 17.3 6.3 5.4 15.6 coralline crust 13.4 7.4 7.9 5.5 7.2 7.7 10.6 10.1 9.8 Gelidium coulteri 6.3 3.4 5.3 2.8 16.9 11.3 8.3 4.0 9.2 Endocladia muricata 8.0 9.9 11.6 17.1 9.2 12.8 7.2 9.1 9.0 Corallina vancouveriensis 8.7 7.3 7.5 7.9 3.5 6.2 10.5 8.5 7.6 Gastroclonium subarticulatum 7.0 8.2 8.6 8.9 8.0 8.0 6.3 9.0 7.5 Phyllospadixspp.

5.1 11.2 5.8 15.2 6.5 14.0 8.1 15.3 6.4 Mastocarpus papillatus 3.3 2.3 6.7 5.2 7.2 6.4 4.5 6.5 5.4 Cryptopleura violacea 8.0 7.1 3.5 4.0 4.8 4.6 3.6 4.2 5.0 Egregia menziesii 0.9 1.6 1.5 2.3 6.0 6.9 8.3 11.0 4.1 Calliarthron/Bossiella spp.-complex 4.4 7.1 4.9 10.4 3.4 8.3 2.8 5.2 3.9 Chondracanthus canaliculatus 5.5 5.9 4.1 6.2 5.3 4.1 0.8 1.2 3.9 Prionitis spp. 2.0 1.9 2.8 5.7 1.8 3.3 3.9 3.6 2.6 juv. articulated coralline algae 1.7 1.7 0.9 1.3 2.2 3.7 1.4 2.1 1.6 Mastocarpusjardinii 0.5 0.7 0.8 1.4 1.5 2.2 1.7 2.3 1.1 Mazzaella oregona 0.2 0.5 0.6 0.5 2.0 3.1 1.3 3.1 1.0 Mazzaella affinis 1.0 2.4 0.4 0.9 1.5 2.1 0.1 0.3 0.8 Smithora naiadum ----1.0 2.0 0.3 1.1 0.3 Cryptosiphonia woodii 0.4 0.7 <0.1 <0.1 0.3 1.1 --0.2 Microcladia coulteri ----0.4 0.7 <0.1 <0.1 0.1 Mazzaella leptorhynchos

<0.1 0.2 0.1 0.3 <0.1 0.2 <0.1 Acrosiphonia spp. --0.3 0.9 --<0.1 Microcladia borealis --0.3 0.6 <0.1 filamentous red algae complex <0.1 0.2 0.2 0.7 <0.1 Porphyraspp.

<0.1 <0.1 0.1 0.4 <0.1 <0.1 <0.1 Chondracanthus corymbife,"us


0.1 0.4 <0.1 Pterosiphonia dendroidea 0.1 0.4 --<0.1 Macrocystis pyrifera --<0.1 0.2 <0.1 0.2 <0.1 Osmundeaspp.

<0.1 0.2 <0.1 <0.1 <0.1 <0.1 <0.1 Laminaria setchellii

--<0.1 0.2 <0.1 <0.1 <0.1 Cryptopleura ruprechtiana


<0.1 0.2 .<0.1 Halymenia/Schizymenia spp.-complex

<0.1 0.2 ---<0.1 Cladophora spp. <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Gelidiumpusillum

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Callithamnionpikeanum

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Ulvaspp. <0.1 <0.1 --<0.1 <0.1 <0.1 Sarcodiotheca gaudichaudii


<0.1 <0.1 <0.1 Callithamnion spp./Pleonosporium spp. <0.1 <0.1 <0.1 <0.1 --<0.1 Chlorophyta (filamentous)

<0.1 <0.1 --<0.1 Corallina chilensis

<0.1 <0.1 <0.1 Bryopsis spp. <0.1 <0.1 <0.1 (table continued) f --rESLO2014-02 C-14 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C7 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for Field's Cove Station FC 2+0.3m (5+1).Survey 172 173 174 175 Survey Date 7-Mar-13 12-Apr-13 10-Jul-13 7-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts Chlorostoma funebralis 83.8 67.3 78.4 90.3 7.0 5.8 17.6 19.4 46.7 Anthopleura elegantissima 19.2 25.6 15.6 23.2 21.4 34.1 42.2 72.2 24.6 Strongylocentrotus purpuratus 30.2 27.1 14.0 13.1 12.6 12.4 23.0 26.4 20.0 Pagurus spp. 11.8 8.7 7.0 11.6 5.4 7.4 9.4 9.3 8.4 Nuttallina califomica 5.8 5.8 3.6 4.5 3.4 6.5 2.6 4.2 3.9 Tetraclita rubescens 7.8 12.3 --1.0 2.2 4.8 10.7 3.4 Fissurella volcano 4.4 2.1 0.6 0.9 1.0 1.0 5.0 7.5 2.8 Chlorostoma brunnea 1.6 2.2 0.8 1.1 2.0 2.7 4.2 7.8 2.2 Leptasterias spp. 2.2 1.1 1.6 1.8 0.6 1.3 1.4 0.5 1.5 Pachygrapsus crassipes 0.2 0.4 1.2 2.2 2.0 2.5 1.0 1.4 1.1 Lottia limatula 0.6 0.5 1.2 1.3 0.2 0.4 1.2 1.8 0.8 Lottia scabra 0.6 0.9 1.8 2.2 --0.4 0.9 0.7 Lottia scutum 0.6 0.9 0.8 1.1 0.4 0.9 --0.5 Pisaster ochraceus 0.4 0.5 1.0. 1.2 --0.4 0.5 0.5 Epiactis prolifera


1.0 2.2 0.4 0.9 0.4 Nemertea 0.2 0.4 0.8 0.8 0.2 0.4 0.2 0.4 0.4 Ocinebrina spp. 0.6 0.9 0.4 0.5 --0.4 0.5 0.4 Lottia pelta --C.6 0.9 0.2 0.4 0.4 0.5 0.3 Nucella spp. 0.4 0.9 0.4 0.9 ----0.2 Hemigrapsus nudus ------0.4 0.9 0.1 Pelecypoda borng <0.1 <0.1 <0.1 <0.1 0.2 0.4 <0.1 Pugettia spp. 0.2 0.4 --<0.1 <0.1 <0.1 Nereididae 0 -0.2 0.4 --<0.1 Acanthinucella spp. 0.2 0.4 <0.1 Mopalia spp. 0.2 0.4 <0.1 Serpulorbis squamigerus 0.2 0.4 --<0.1 Pycnopodia helianthoides

--0.2 0.4 <0.1 Lottiidae

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Lacuna spp. <0.1 <0.1 <0.1 <0.1 <0. <0.1 <0.1 <0.1 <0.1 Sipuncula

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Ischnochitonidae

-<0.1 <0.1 -<0.1 <0.1 <0.1 Grapsidae

<0.1 <0.1 <0.1 <0.1 <0.1 Lirobittium spp. <0.1 <0.1 <0.1 <0.1 <0.1 Heptacarpus spp. <0.1 <0.1 <0.1 Mytilus spp. <0.1 <0.1 <0.1 <0.1 --<0.1 Acmaea mitra ----<0.1 <0.1 <0.1 Cyanoplax spp. <0.1 <0.1 -<0.1 Lottia ochracea <0.1 <0.1 <0.1 Epitonium/Opalia spp. --<0.1 <0.1 <0.1 Pycnogonida

-<0.1 <0.1 <0.1 Pisaster/Henricia spp. (juv.) --<0.1 <0.1 <0.1 Serpulidae

<0.1 <0.1 --<0.1 Amphissa spp. --<0.1 <0.1 <0.1 Barleeia spp. <0.1 <0.1 -<0.1 (table continued)

I=- ESL02014-02 C-15 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C7 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m 2) survey means, standard deviations and 2013 annual means for Field's Cove Station FC 2+0.3m (5+1).Survey 172 173 174 175 Survey Date 7-Mar-13 12-Apr-13 10-Jul-13 7-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Cover Pista spp. 0.3 0.9 0.5 1.0 0.2 0.7 0.6 1.8 0.4 Phragmatopoma califomica 0.4 0.9 <0.1 <0.1 <0.1 <0.1 0.7 2.0 0.3 bryozoa (encrusting)

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 0.6 2.0 0.2 Chthamalus fissus <0.1 0.2 <0.1 -<0.1 <0.1 0.1 0.3 <0.1 Dodecaceria fewkesi --<0.1 <0.1 <0.1 <0.1 0.1 0.4 <0.1 Spirorbidae

<0.1 -<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 tunicates, compound/social

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Porifera (encrusting)

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Salmacina tribranchiata

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Haliclona spp. ----<0.1 <0.1 --<0.1 Substrate Cover rock 8.1 7.8 6.9 6.0 8.8 6.6 5.9 5.5 7.4 sand (shell gravel) 1.0 1.9 1.0 1.7 0.6 1.5 5.4 7.7 2.0 cobble 0.8 1.1 <0.1 <0.1 0.3 1.1 0.1 0.4 0.3 W-ESLO2014-02 C-16 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C8. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for Field's Cove Station FC 2+0.9m (5+3).Survey 172 173 174 175 Survey Date 24-Jan-13 13-Jun-13 18-Sep-13 7-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Cover Endocladiamuricata 35.0 11.2 39.5 12.1 35.5 20.6 26.5 4.8 34.1 non-coralline crust 20.6 14.9 17.0 10.9 20.6 9.8 19.4 13.7 19.4 Mastocarpus papillatus 5.8 2.9 11.5 4.5 15.5 7.2 9.5 7.9 10.6 Silvetia compressa 2.4 4.7 1.1 2.1 2.8 5.3 3.5 5.4 2.4 Mazzaella flaccida 0.2 0.5 1.8 4.8 3.1 3.8 0.3 0.5 1.4 Gelidium coulteri <0.1 <0.1 <0.1 0.2 2.8 4.3 <0.1 0.2 0.7 Fucus gardneri 0.5 1.5 1.1 3.5 0.2 0.7 0.6 1.8 0.6 Mastocarpusjardinii 0.1 0.4 --0.8 1.0 0.8 1.4 0.4 Prionitis spp. 0.1 0.4 0.2 0.7 0.2 0.5 0.6 1.1 0.3 Porphyraspp.

<0.1 <0.1 <0.1 0.2 0.2 0.5 0.5 1.1 0.2 Hesperophycus californicus 0.1 0.4 <0.1 <0.1 --0.3 0.8 0.1 coralline crust 0.4 0.6 <0.1 -<0.1 -<0.1 -0.1 Cladophora spp. <0.1 <0.1 <0.1 0.2 <0.1 0.2 0.2 0.5 <0.1 Gelidiumpusillum

<0.1 -<0.1 <0.1 <0.1 0.2 <0.1 0.2 <0.1 Cryptopleura violacea ---0.1 0.4 --<0.1 Mazzaellaoregona

<0.1 <0.1 <0.1 <0.1 0.1 0.4 <0.1 Halymenia/Schizymenia spp.-complex

--0.1 0.4 --<0.1 Mazzaella affinis <0.1 <0.1 <0.1 <0.1 <0.1 0.2 <0.1 <0.1 <0.1 Mazzaella leptorhynchos

--<0.1 <0.1 <0.1 0.2 -<0.1 juv. articulated coralline algae <0.1 <0.1 --<0.1 <0.1 -<0.1 Corallina vancouveriensis

<0.1 <0.1 --<0.1 <0.1 <0.1 <0.1 <0.1 Cryptosiphonia woodii <0.1 <0.1 <0.1 <0.1 -. -<0.1 Chondracanthus canaliculatus

<0.1 <0.1 --<0.1 <0.1 <0.1 Ulva spp. --<0.1 <0. --<0.1 Invertebrate Counts Ch/orostoma funebralis 101.6 42.1 97.2 21.5 318.8 235.3 206.8 50.3 181.1 Anthopleura elegantissima 87.0 40.1 58.8 65.3 46.8 29.0 99.8 77.2 73.1 Lottiascabra 16.4 17.6 11.6 10.1 21.8 23.5 14.0 15.8 16.0 Lottia limatula 0.8 1.3 4.8 7.0 1,;.4 16.1 6.6 10.9 5.9 Pagurus spp. 5.6 10.9 4.8 2.6 1.8 2.7 9.2 9.6 5.4 Pachygrapsus crassipes 0.8 1.3 1.0 1.0 1.6 2.1 1.0 1.0 1.1 Cyanoplax spp. <0.1 <0.1 <0.1 <0.1 3.4 2.7 0.2 0.4 0.9 Ocinebrina spp. 1.4 1.3 0.4 0.5 0.6 0.9 1.0 0.7 0.9 Lottia pelta 1.6 1.5 --0.2 0.4 1.2 1.3 0.8 Acanthinucella spp. 1.2 1.6 0.4 0.9 0.4 0.5 0.8 1.1 0.7 Pollicipes polymerus

--2.4 5.4 ----0.6 Lottiidae 0.4 0.9 0.4 0.9 1.2 2.7 0.2 0.4 0.6 Lottia scuturn 0.2 0.4 0.6 0.9 0.4 0.9 0.4 0.5 0.4 Nemertea 0.2 0.4 --0.8 1.3 0.2 0.4 0.3 Cirratulidae/Terebellidae 0.2 0.4 0.2 0.4 --0.4 0.9 0.2 Nucella spp. 0.4 0.9 ----0.1 Mytilus spp. --0.4 0.9 ----0.1 Lacuna spp. 0.2 0.4 <0.1 <0.1 <0.1 (table continued)

--ES LO 2014-02 C-17 v ,.

Appendix C -Intertidal Algae, Invertebrates and Substrates Table C8 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for Field's Cove Station FC 2+0.9m (5+3).Survey 172 173 174 175 Survey Date 24-Jan-13 13-Jun-13 18-Sep-13 7-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Epiactis prolifera 0.2 0.4 --<0.1 Fissurella volcano --0.2 0.4 <0.1 Mopalia spp. 0.2 0.4 <0.1 Pisasterochraceus

--0.2 0.4 ----<0.1 Littorina spp. <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Ischnochitonidae


<0.1 <0.1 <0.1 Sipuncula

<0.1 <0.1 <0.1 <0.1 ----<0.1 Barleeia spp. ----<0.1 <0.1 <0.1 <0.1 <0.1 Grapsidae

<0.1 <0.1 <0.1 <0.1 --<0.1 Crepidula spp. ----<0.1 <0.1 <0.1 Epitonium/Opalia spp. <0.1 <0.1 --<0.1 Pelecypoda boring <0.1 <0.1 <0.1 Amphissa spp. <0.1 <0.1 ----<0.1 Triopha spp. ----<0.1 <0.1 <0.1 Invertebrate Cover Phragmatopoma californica

<0.1 -0.6 1.1 0.5 0.7 1.9 1.9 0.8 Chthamalus fissus 0.1 0.4 <0.1 -0.1 0.4 <0.1 -<0.1 Spirorbidae

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 -<0.1 Haliclonaspp.

<0.1 <0.1 --<0.1 <0.1 <0.1 Porifera (encrusting)

<0.1 <0.1 <0.1 Substrate Cover rock 28.1 11.4 27.3 15.7 29.0 20.3 31.0 17.9 28.9 sand (shell gravel) 8.1 15.9 2.4 7.0 2.1 3.3 5.4 10.0 4.5 cobble 0.6 1.3 0.2 0.7 <0.1 0.2 <0.1 <0.1 0.2ESL12014-02 C-18 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C9. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for Field's Cove Station FC 3+0.3m (6+1).Survey 172 173 174 175 Survey Date 5-Feb-13 15-May-13 7-Aug-13 14-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Cover non-coralline crust 39.4 7.5 25.8 9.7 18.2 6.7 47.6 17.7 32.7 Mazzaella flaccida 20.2 16.6 43.9 27.5 39.2 22.0 21.9 20.5 31.3 Gastrocloniumsubarticulatum 15.3 11.9 16.4 18.2 17.3 18.1 13.3 11.0 15.6 coralline crust 12.0 6.1 4.4 5.4 9.0 8.5 8.3 4.8 8.4 Phyllospadixspp.

4.9 9.2 6.1 10.9 7.9 15.5 6.4 11.1 6.3 Cryptopleura violacea 8.3 7.8 2.3 2.4 10.9 8.2 2.6 3.3 6.0 Gelidium coulteri 1.5 2.4 4.7 5.3 11.0 9.1 3.4 2.8 5.2 Chondracanthus canaliculatus 3.2 2.5 6.0 4.5 7.8 6.5 2.0 2.5 4.8 Mastocarpus jardinii 2.9 3.7 3.5 3.9 4.7 7.6 4.1 3.9 3.8 Calliarthron/Bossiella spp.-complex 2.8 3.9 4.5 7.7 3.7 7.0 4.0 6.2 3.8 Mastocarpus papillatus 1.2 1.2 7.4 6.6 3.8 4.9 0.9 1.0 3.3 Mazzaella oregona 0.7 1.0 4.9 5.4 0.3 0.7 0.8 1.1 1.7 Mazzaella affinis 1.2 2.3 2.4 3.4 1.6 4.3 1.0 1.0 1.5 Corallina vancouveriensis 1.5 1.6 0.5 1.1 2.1 3.0 1.8 3.0 1.5 Prionitis spp. 1.3 1.1 1.0 0.7 1.1 1.4 2.2 3.8 1.4 Smithora naiadum ----3.8 7.9 <0.1 <0.1 1.0 juv. articulated coralline algae 0.3 0.6 0.6 1.0 0.6 1.2 0.8 1.2 0.6 Endocladia muricata 0.9 2.1 0.4 0.9 0.2 0.5 0.6 1.7 0.5 filamentous red algae complex 0.3 0.9 0.4 1.1 0.3 0.9 1.2 2.5 0.5 Egregia menziesii

<0.1 <0.1 --1.1 2.4 --0.3 Chondracanthus corymbiferus 0.3 0.9 0.1 0.4 <0.1 0.2 0.3 0.9 0.2 Porphyraspp.

<0.1 <0.1 --0.6 2.0 --0.2 Cryptosiphonia woodii 0.2 0.5 0.4 1.1 <0.1 <0.1 0.2 Microcladia coulteri ----0.6 1.3 --0.1 Gelidiumpusillum 0.3 0.9 --<0.1 <0.1 <0.1 <0.1 <0.1 Sarcodiotheca gaudichaudii 0.2 0.7 <0.1 0.2 <0.1 <0.1 --<0.1 Mazzaellaleptorhynchos

<0.1 <0.1 0.1 0.3 <0.1 <0.1 <0.1 0.2 <0.1 Osmundeaspp.

<0.1 <0.1 <0.1 <0.1 <0.1 0.2 0.1 0.4 <0.1 Corallina chilensis

<0.1 0.2 --0.1 0.4 --<0.1 Pterosiphonia dendroidea 0.2 0.7 ----<0.1 Microcladia borealis --<0.1 0.2 <0.1 0.2 <0.1 Ulva spp. <0.1 <0.1 --<0.1 0.2 <0.1 Callithamnion pikeanum <0.1 <0.1 <0.1 0.2 <0.1 <0.1 <0.1 Cladophora spp. <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Colpomenia spp. ---<0.1 <0.1 <0.1 Chrysophyta

<0.1 <0.1 <0.1 <0.1 <0.1 Halymenia/Schizymenia spp.-complex

-- .<0.1 <0.1 <0.1 Chlorophyta (filamentous)

<0.1 <0.1 <0.1 Bryopsis spp. <0.1 <0.1 -<0.1 (table continued) wA-- ESL02014-02 C-19 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C9 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 amnual means for Station FC 3+0.3m (6+ 1).Survey 172 173 174 175 Survey Date 5-Feb-13 15-May-13 7-Aug-13 14-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts Strongylocentrotuspurpuratus 24.4 37.3 32.6 71.2 19.4 35.3 48.0 101.8 31.1 Chlorostoma funebralis 90.6 49.9 10.2 12.6 4.4 6.2 15.2 8.4 30.1 Tetraclita rubescens 20.6 20.1 2.6 2.8 2.6 5.8 17.4 16.8 10.8 Chlorostoma brunnea 9.0 8.4 4.8 3.3 18.0 10.5 2.0 1.4 8.5 Pagurus spp. 10.0 6.4 3.8 3.4 11.4 2.9 8.4 10.7 8.4 Anthopleura elegantissima 5.2 1.3 5.2 3.8 4.8 3.3 16.6 15.8 8.0 Fissurella volcano 5.0 4.9 2.4 1.8 6.2 5.3 2.4 2.6 4.0 Pachygrapsus crassipes 0.6 0.5 1.4 1.9 1.2 0.8 0.4 0.5 0.9 Leptasterias spp. 1.4 1.7 0.2 0.4 1.2 1.3 0.4 0.5 0.8 Nemertea 0.2 0.4 --1.0 1.2 1.0 1.2 0.6 Lottia pelta 0.6 0.9 0.8 1.1 0.6 1.3 0.2 0.4 0.6 Ocinebrina spp. 1.2 1.6 0.2 0.4 0.6 0.9 0.2 0.4 0.6 Serpulidae 1.0 1.0 <0.1 <0.1 0.4 0.9 0.6 0.9 0.5 Serpulorbis squamigerus 0.8 0.8 0.4 0.5 ----0.3 Pugettia spp. 0.4 0.5 --0.4 0.5 --0.2 Lottia limatula 0.2 0.4 0.4 0.5 0.2 0.4 0.2 Pisaster ochraceus 0.2 0.4 0.2 0.4 0.2 0.4 0.2 Epiactis prolifera 0.6 1.3 ----0.2 Lottia scabra 0.4 0.9 --0.1 Lottia scutum --0.2 0.4 0.2 0.4 0.1 Acanthinucella spp. --0.2 0.4 --<0.1 Calliostoma ligatum 0.2 0.4 --<0.1 Hemigrapsus nudus 0.2 0.4 --<0.1 Romaleon antennarius

--0.2 0.4 <0.1 Pseudomelatoma torosa 0.2 0.4 --<0.1 Lottiidae

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Aliaspp. <0.1 <0.1 --<0.1 <0.1 <0.1 <0.1 <0.1 Lacuna spp. <0.1 <0.1 <0.1 <0.1 --<0.1 <0.1 <0.1 Sipuncula

<0.1 <0.1 --<0.1 <0.1 --<0.1 Acmaeamitra

<0.1 <0.1 --<0.1 <0.1 <0.1 Epitonium/Opalia spp. <0.1 <0.1 <0.1 <0.1 -<0.1 Pelecypoda bodng --<0.1 <0.1 <0.1 Crepidula spp. <0.1 <0.1 --<0.1 Heptacarpus spp. <0.1 <0.1 <0.1 <0.1 <0.1 Grapsidae

--<0.1 <0.1 -<0.1 Homolo. luridum/Lirularia succincta

<0.1 <0.1 --<0.1 <0.1 <0.1 Cyanoplaxspp.

-<0.1 .<0.1 --<0.1 Lirobittiumspp.

<0.1 <0.1 <0.1 Amphissa spp. <0.1 <0.1 -<0.1 Platyhelminthes

<0.1 <0.1 <0.1 (table continued)

M- ESL02014-02 C-20 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C9 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m 2) survey means, standard deviations and 2013 annual means for Station FC 3 0.3m (6+1).Survey 172 173 174 175 Survey Date 5-Feb-13 15-May-13 7-Aug-13 14-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Cover Pista spp. 0.1 0.3 0.3 1.1 2.4 6.0 4.4 6.6 1.8 Phragmatopoma califomica 1.9 3.0 0.6 1.1 1.0 3.3 0.8 2.4 1.1 Porifera (encrusting)

<0.1 <0.1 <0.1 <0.1 0.2 0.5 <0.1 <0.1 <0.1 tunicates, compound/social

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 0.2 0.7 <0.1 Chthamalus fissus <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Spirorbidae

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 -<0.1 bryozoa (encrusting)

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Salmacina tribranchiata

<0.1 <0.1 ----<0.1 <0.1 <0.1 Substrate Cover rock 1.2 1.2 1.6 2.3 1.5 1.3 1.5 1.3 1.4 sand (shell gravel) 1.7 3.9 1.0 1.9 1.5 2.2 1.3 2.6 1.4 cobble 0.3 0.6 <0.1 0.2 <0.1 <0.1 <0.1 <0.1 <0.1 WEW SLO2014-02 C2 (1-21 Appendix C -Intertidal Algae, Invertebrates and Substrates Table CIO. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m 2) survey means, standard deviations and 2013 annual means for Field's Cove Station FC 3+0.9m (6+3).Survey 172 173 174 175 Survey Date 5-Feb-13 15-May-13 7-Aug-13 14-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Cover Endoc/adia muricata non-coralline crust Mastocarpus papillatus Mazzaella flaccida Silvetia compressa Gelidium coulteri Mastocarpus jardinii coralline crust Gelidium pusillum Mazzaella affinis Chondracanthus canaliculatus Prionitis spp.Mazzaella oregona Corallina vancouver/ensis Cryptosiphonia woodii Mazzaella leptorhynchos Cryptopleura violacea Gastroclonium subarticulatum Porphyra spp.Cladophora spp.juv. articulated coralline algae Ulva spp.Calliarthron/Bossiella spp.-complex Chlorophyta (filamentous)

Invertebrate Counts Ch/orostoma funebra/is Anthopleura elegantissima Pagurus spp.Lottia scabra Ocinebrina spp.Pachygrapsus crassipes Lottia limatula Lottia scutum Acanthinucella spp.Lottia pe/ta Strongylocentrotus purpuratus Cyanoplax spp.Nemertea Cirratulidae/Terebellidae Lottiidae Nereididae Tetraclita rubescens LeDtasterias SDD.32.7 42.6 9.9 3.6 2.1 1.7 2.7 1.5 1.2 1.4 0.8<0.1 0.3 0.5 0.3 0.1<0.1<0.1<0.1<0.1<0.1<0.1 16.1 11.2 7.1 3.5 3.5 2.9 3.2 1.6 1.5 3.3 1.8<0.1 0.6 1.1 1.1 0.3<0.1 0.2<0.1<0.1<0.1 42.9 22.8 22.2 9.6 2.8 1.7 0.3 0.2 1.1<0. "<0.1 0.7 0.3<0.1<0.1<0.1<0.1<0.1<0.1<0.1 207.0 8.6 5.8 2.2 0.2 0.4 0.6 0.6 0.4 0.8 0.6<0.1<0.1 21.1 16.3 12.3 8.2 3.9 2.4 0.6 0.5 2.1<0.1 0.2 2.0 0.5 0.2 0.2<0.1<0.1<0.1<0.1<0.1 75.8 10.0 9.2 1.8 0.4 0.5 1.3 1.3 0.9 1.8 1.3<0.1<0.1 25.9 14.9 45.0 18.5 3.3 2.7 0.6 0.4<0.1 0.3<0.1<0.1 0.3 0.1<0.1<0.1 0.2<0.1<0.1<0.1<0.1 409.8 8.2 9.2 5.0 0.8 1.0 0.4 1.0 0.2 0.8 0.2 0.6 0.4 0.4 0.2 0.2 13.3 5.3 15.9 7.5 5.8 4.9 0.8 0.6 0.5<0.1 0.2 0.4 0.4 0.2 0.2 0.7<0.1 0.2<0.1 212.1 10.3 9.4 3.6 1.1 1.0 0.5 1.0 0.4 1.1 0.4 1.3 0.9 0.9 0.4 0.4 24.0 43.5 19.7 2.6 2.7 1.7 0.7 1.8<0.1<0.1 0.3 0.3<0.1<0.1 0.1<0.1<0.1<0.1<0.1 8.5 8.7 6.3 1.3 4.2 2.2 1.1 2.2 0.2<0.1 0.6 0.6 0.2 0.2 0.4<0.1<0.1<0.1<0.1 31.4 30.9 24.2 8.6 2.7 1.9 1.1 1.0 0.6 0.4 0.3 0.3 0.3 0.2 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 249.9 13.3 11.5 2.5 0.9 0.9 0.6 0.6 0.6 0.5 0.3 0.2 0.1 0.1<0.1<0.1<0.1<0.1 247.0 111.2 23.0 44.3 4.4 5.6 1.2 1.1 2.0 2.3 1.4 1.5 0.4 0.9 0.8 1.8 1.0 1.0<0.1 <0.1 0.2 0.4 0.2 0.4 135.8 61.1 13.2 17.7 26.6 12.8 1.4 2.6 0.6 0.5 0.8 1.1 1.0 1.0 0.6 0.9 0.4 0.5 0.2 0.4<0.1 <0.1<0.1 (table continued)

MW ESLO2014-02 C-22 Appendix C -Intertidal Algae, Invertebrates and Substrates Table CIO (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for Field's Cove Station FC 3+0.9m (6+3).Survey 172 173 174 175 Survey Date 5-Feb-13 15-May-13 7-Aug-13 14-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Pisaster ochraceus 0.2 0.4 --<0.1 Serpulidae


0.2 0.4 <0.1 Grapsidae

<0.1 <0.1 --<0.1 Lacuna spp. <0.1 <0.1 --<0.1 <0.1 <0.1 Crepidula spp. --<0.1 <0.1 --<0.1 Epitonium/Opalia spp. <0.1 <0.1 --<0.1 Barleeia spp. ----<0.1 <0.1 <0.1 Invertebrate Cover Phragmatopoma califomica 1.6 2.2 0.1 0.3 0.3 0.5 3.6 3.2 1.4 Chthamalus fissus 0.3 1.1 <0.1 <0.1 0.1 0.4 <0.1 0.2 0.1 Pista spp. -----<0.1 <0.1 <0.1 Porifera (encrusting)

<0.1 <0.1 ------<0.1 Substrate Cover rock 6.8 9.4 9.6 12.7 5.9 5.5 7.8 6.1 7.5 sand (shell gravel) 4.0 6.5 3.8 7.9 1.4 2.5 0.6 2.0 2.4 cobble <0.1 0.2 0.2 0.5 <0.1 0.2 <6.1 0.2 0.1 WNWESLO2014-02 C-23 Appendix C -Intertidal Algae, Invertebrates and Substrates Table ClI. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for North Diablo Cove Station NDC 1+0.3m (7+1).Survey 172 173 174 175 Survey Date 6-Mar-13 7-Jun-13 16-Sep-13 16-Dec-13 Std. Std. Std. Std. ' Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Al-gae Cover non-coralline crust 53.6 6.7 54.9 13.0 30.3 13.9 38.0 16.3 44.2 U/va spp. 0.8 1.3 9.5 7.5 7.2 4.1 <0.1 <0.1 4.4 filamentous red algae complex 3.6 5.1 1.7 3.7 3.9 5.1 7.2 6.9 4.1 Codium fragile subsp. Californicum 2.3 3.6 1.6 2.6 4.3 5.6 4.9 5.0 3.3 coralline crust 3.1 4.7 1.9 2.7 1.9 2.6 2.5 2.3 2.3 Gelidium coutteri 0.3 0.6 0.7 0.8 5.3 4.3 0.3 1.1 1.7 Mastocarpus papillatus 1.4 1.6 1.2 2.9 0.7 1.1 0.5 1.0 1.0 Colpomenia spp. <0.1 <0.1 0.2 0.3 2.6 2.9 --0.7 Corallina vancouveriensis 0.8 1.5 0.3 0.7 <0.1 <0.1 0.1 0.4 0.3 Pterosiphonia dendroidea 0.6 1.3 --<0.1 <0.1 --0.2 Mazzaella affinis <0.1 <0.1 <0.1 0.2 0.5 0.8 <0.1 <0.1 0.1 Gelidium pusillum 0.3 0.7 0.1 0.4 --<0.1 <0.1 0.1 Cladophoraspp.

--<0.1 <0.1 0.4 0.4 <0.1 <0.1 0.1 Chondracanthus canaliculatus

<0.1 <0.1 0.1 0.4 <0.1 <0.1 0.2 0.7 <0.1 Porphyraspp.

0.2 0.3 <0.1 <0.1 ----<0.1 Chlorophyta (filamentous)


0.2 0.5 <0.1 <0.1 <0.1 Mastocarpus jardinii <0.1 <0.1 <- 0.I <0.1 0.1 0.3 <0.1 Cryptopleura violacea 0.1 0.3 <0.1 <0.1 --<0.1 <0.1 <0.1 juv. articulated coralline algae <0.1 0.2 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Prionitis spp. ---<0.1 0.2 <0.1 <0.1 <0.1 Chondracanthus corymbiferus

--<0.1 0.2 --<0.1 Cystoseira osmundacea

<0.1 0.2 --<0.1 Calliarthron/Bossiella spp.-complex

--<0.1 <0.1 <0.1 Bryopsis spp. --<0.1 <0.1 <0.1 Laminariales

<0.1 <0.1 <0.1 <0.1 --<0.1 Acrosiphoniaspp.


<0.1 <0.1 <0.1 Chrysophyta

<0.1 <0.1 --<0.1 Macrocystis pyrifera --<0.1 <0.1 <0.1 Invertebrate Counts Tetraclita rubescens 212.4 138.9 424.2 152.0 211.2 227.2 472.6 180.3 330.1 Lottia scabra 18.8 14.6 62.0 25.9 148.2 141.8 137.6 175.9 91.7 Pagurus spp. 43.0 20.1 25.6 14.5 4.6 6.3 106.2 178.6 44.9 Strongylocentrotus purpuratus 4.8 2.7 14.8 11.3 24.4 21.8 6.4 5.8 12.6 Fissurella volcano 12.0 6.3 21.2 8.7 3.8 1.3 12.6 7.8 12.4 Lottia pe/ta 4.0 2.5 8.6 7.5 8.8 7.9 13.2 3.3 8.7 Anthopleura elegantissima 4.0 3.2 5.0 3.7 2.6 1.5 6.4 4.3 4.5 Chlorostoma brunnea 2.8 4.1 11.0 10.7 2.6 3.7 1.4 2.2 4.5 Chlorostoma funebralis

--6.6 14.2 0.8 1.8 3.2 6.1 2.7 Lottia limatula 2.4 1.8 1.0 1.0 3.8 4.1 2.6 2.6 2.5 Pachygrapsus crassipes 0.6 0.5 1.4 0.9 5.6 2.7 1.4 1.7 2.3 Lottia scutum 1.2 0.8 0.6 0.9 1.8 2.5 1.0 2.2 1.2 Anthopleura xanthogrammica 0.6 0.9 0.2 0.4 0.6 0.5 0.4 0.5 0.5 Ocinebrina spp. 0.2 0.4 0.4 0.5 --0.6 0.9 0.3 Lottia gigantea 0.6 0.5 <0.1 <0.1 0.4 0.5 0.3 (table continued)" -- ESL02014-02 C-24 Appendix C -Intertidal Algae, Invertebrates and Substrates Table CII (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for North Diablo Cove Station NDC 1+0.3m (7+ 1).Survey 172 173 174 175 Survey Date 6-Mar-13 7-Jun-13 16-Sep-13 16-Dec-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Nuttallina califomica

--0.2 0.4 0.6 0.9 0.2 Diodora spp. 0.2 0.4 --0.2 0.4 0.1 Epiactis prolifera

--0.2 0.4 0.2 0.4 0.1 Hemigrapsus nudus 0.4 0.9 ----0.1 Serpulidae

--0.2 0.4 0.2 0.4 0.1 Natantia ----0.4 0.9 --0.1 Acanthinucella spp. 0.2 0.4 ----<0.1 Mopalia spp. --0.2 0.4 --<0.1 Diopatra ornata --0.2 0.4 <0.1 Pisaster ochraceus 0.2 0.4 <0.1 Lottiidae

<0.1 -<0.1 <0.1 -<0.1 -<0.1 Ischnochitonidae

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Grapsidae

-<0.1 -----<0.1 Alia spp. --<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Littorinaspp.

<0.1 <0.1 <0.1 <0.1 --<0.1 <0.1 <0.1 Mytilus spp. ------<0.1 <0.1 <0.1 Homolo. luridum/Lirularia succincta

<0.1 <0.1 --<0.1 Cyanoplaxspp.

-<0.1 <0.1 <0.1 Pollicipes polymerus

<0.1 <0.1 <0.1 Crassadoma gigantea <0.1 <0.1 -<0.1 Heptacarpus spp. <0.1 <0.1 <0.1 Sipuncula

<0.1 <0.1 <0.1 Invertebrate Cover Phragmatopoma califomica 7.8 3.4 4.9 3.0 5.2 4.4 5.6 3.5 5.9 Chthamalus fissus 1.7 2.0 4.0 7.2 4.0 6.0 7.7 6.6 4.3 Spirorbidae

<0.1 -<0.1 <0.1 <0.1 <0.1 <0.1 -<0.1 tunicates, compound/social

<0.1 <0.1 --<0.1 <0.1 <0.1 Pistaspp.

-<0.1 <0.1 <0.1 Salmacina tribranchiata

<0.1 <0.1 ----<0.1 Substrate Cover rock 11.2 5.2 15.5 8.2 30.3 13.7 27.4 12.2 21.1 sand (shell gravel) 4.7 2.2 5.9 3.7 7.4 5.9 9.0 4.4 6.7 cobble 8.7 4.5 4.4 1.5 5.3 4.3 5.3 4.0 5.9 W- ESL02014-02 C-25 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C12. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for North Diablo Cove Station NDC 1+0.9m (7+3).Survey 172 173 174 175 Survey Date 6-Mar-13 7-Jun-13 16-Sep-13 16-Dec-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Al-gae Cover non-coralline crust Endocladia muricata Mastocarpus papilatus Ulva spp.Gelidium coulteri Mazzaella affinis coralline crust Mazzaella leptorhynchos Prionitis spp.Gelidium pusillum Cladophora spp.Porphyra spp.Chondracanthus canaliculatus Mastocarpus jardinli filamentous red algae complex Invertebrate Counts Chlorostoma funebralis Anthop/eura elegantissima Lottia scabra Pagurus spp.Lottia pelta Lottia limatula 57.7 4.3 1.1<0.1<0.1 0.3<0.1<0.1<0.1<0.1<0.1<0.1 129.4 25.8 11.4 1.4 0.6 1.8 2.8 2.0 0.2 0.8 0.2 0.2 0.2 0.2<0.1<0.1<0.1<0.1<0.1 26.8 7.9 1.3<0.1 0.2 0.7 0.2<0.1<0.1<0.1<0.1 68.1 25.8 14.8 1.3 0.5 2.5 1.6 1.6 0.4 0.8 0.4 0.4 0.4 0.4<0.1<0.1<0.1<0.1 53.7 19.1 5.1 9.7 4.4 3.3 4.9 8.9<0.1 <0.1 0.4 0.7 0.1 0.4<0.1 0.2<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 178.0 183.9 36.4 44.0 6.2 3.0 6.6 9.5 1.4 2.2 0.6 0.9 0.6 1.3 0.2 0.4 0.4 0.9 1.0 1.4 0.6 0.9 0.2 0.4 0.2 0.4 0.6 1.3 0.2 0.4<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 50.7 7.2 11.2 0.2 2.7 1.0 0.1 0.4<0.1<0.1<0.1 18.0 13.7 6.3 0.5 2.7 1.8 0.3 0.9<0.1<0.1<0.1<0.1 Fissurella volcano Ocinebrina spp.Lottia scutum Acanthinucella spp.Pachygrapsus crassipes Mopalia spp.Cyanoplax spp.Chlorostoma brunnea Tetraclita rubescens Nuttallina califomica Cirratulidae/Terebellidae Mytilus spp.Lottiidae Littorina spp.Grapsidae Ischnochitonidae Sipuncula Amphissa spp.233.8 214.3 27.8 26.5 40.8 31.1 4.8 4.2 7.4 2.6 8.2 9.0 0.6 0.9 0.4 0.9 2.6 'i.9 0.2 0.4 1.8 1.5 0.2 0.4 1.2 0.8<0.1<0.1 <0.1 50.0 4.7 4.1<0.1<0.1 0.3 0.1<0.1<0.1<0.1<0.1 209.0 47.4 51.8 22.8 7.0 5.6 1.6 1.4 0.6 1.0 0.4 0.8 0.2 0.4<0.1<0.1<0.1<0.1 15.6 8.3 3.5<0.1 0.2 0.9 0.3 0.2 0.2<0.1<0.1 129.1 52.3 28.9 23.7 5.4 3.6 1.5 1.7 0.9 1.2 0.5 1.3 0.4 0.9<0.1<0.1<0.1 53.0 5.3 5.2 1.3 0.7 0.5 0.2 0.2<0.1<0.1<0.1<0.1<0.1<0.1<0.1 187.6 34.4 27.6 8.9 4.1 4.1 1.4 1.0 1.0 0.8 0.8 0.4 0.4 0.2 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 (table continued)

WMWESLO2014-02 C2 C-26 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C12 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for North Diablo Cove Station NDC 1+0.9m (7+3).Survey 172 173 [ 174 175 Survey Date 6-Mar-13 7-Jun-13 16-Sep-13 16-Dec-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Cover Chthamalus fissus 3.1 5.9 3.3 7.7 4.8 7.9 5.5 8.8 4.2 Phragmatopoma califomica 0.3 0.5 <0.1 <0.1 1.3 4.0 0.3 0.7 0.5 Spirorbidae

<0.1 <0.1 <0.1 <0.1 --<0.1 <0.1 <0.1 Substrate Cover rock 24.7 31.2 21.8 22.4 21.4 17.2 25.3 13.8 23.3 sand (shell gravel) 6.1 6.3 8.9 7.0 6.7 6.0 7.4 5.7 7.3 cobble 2.6 2.2 3.4 2.5 2.8 2.0 4.4 3.1 3.3%-- ESLO2014-02 C-27 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C13. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for North Diablo Cove Station NDC 2+0.3m (8+1).Survey 172 173 174 175 Survey Date 25-Feb-13 30-Apr-13 8-Jul-13 6-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Cover Phyllospadix spp.non-coralline crust filamentous red algae complex Codium fragile subsp. Californicum coralline crust Ulva spp.Gastroclonium subarticulatum Gelidium coulteri Corallina vancouveriensis juv. articulated coralline algae Chrysophyta Prionitis spp.Pterosiphonia dendroidea Cryptopleura violacea Chondracanthus canaliculatus Mastocarpus papillatus Mazzaella affinis Gelidiurn pusillum Smithora naiadum Calliarthron/Bossiella spp.-complex Mazzaella leptorhynchos Osmundea spp.Cladophora spp.Sarcodiotheca gaudichaudii Melobesia mediocris Porphyra spp.Bryopsis spp.Macrocystis pyrifera Endocladia muricata Grateloupia califomica Chlorophyta (filamentous)

Invertebrate Counts Tetrac/ita rubescens Lottia scabra Strongylocentrotus purpuratus Fissurella volcano Anthopleura elegantissima Lottia pelta Lottiidae Lottia lirnatula Lottia gigantea Lottia scuturn Balanus spp.Pachvaraosus crassioes 25.3 31.0 33.1 22.6 25.1 18.3 15.0 19.6 5.4 4.7 0.7 0.9 2.2 5.5 0.9 1.6 1.5 3.9 0.3 0.7 2.9 3.8 0.3 0.9<0.1 0.2 0.7 1.4 0.4 1.3<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 0.2 0.5<0.1 0.2<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.!<0.1 <0.1 23.5 32.6 28.7 14.5 24.9 12.0 16.6 16.7 5.1 7.0 8.5 8.7 1.8 4.3 2.1 2.1 0.8 1.4 0.5 1.1 0.1 0.3 0.1 0.3 0.3 0.8 0.2 0.3 0.1 0.3 0.6 0.5<0.1 <0.1<0.1 <0.1<0.1 <0.1 0.1 0.4<0.1 <0.1<0.1 <0.1 97.8 139.2 58.6 70.1 23.2 32.5 24.6 41.3 5.2 5.8 5.8 11.9 0.4 0.9 0.6 0.5 1.0 1.7 0.2 0.4 0.4 0.9 31.6 36.0 25.4 19.5 21.7 13.6 15.9 15.1 4.8 4.3 6.8 8.8 4.8 11.6 2.4 4.0<0.1 <0.1 1.4 4.4 0.4 0.7 1.4 2.1 0.2 0.5 0.9 1.0 1.0 0.9 0.9 1.2 0.1 0.4<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 208.0 355.1 38.4 57.6 29.2 40.6 9.2 7.2 3.2 6.6 5.8 6.1 6.6 14.8 5.4 7.1 1.0 2.2 1.4 1.1 31.5 15.7 19.3 17.5 7.2 0.3 4.7 1.1 2.2 1.0 1.3 0.3 0.7 0.3 0.3 1.1 0.6 0.3<0.1<0.1<0.1<0.1<0.1 101.0 86.6 47.2 6.8 23.0 6.4 2.0 0.4 0.2 5.0 0.6 35.7 6.6 16.0 16.4 10.3 0.7 8.7 3.0 4.7 1.6 2.0 0.6 1.3 0.6 0.5 2.0 2.0 0.9<0.1<0.1<0.1<0.1<0.1 183.8 142.0 56.9 7.2 37.1 7.8 2.8 0.9 0.4 11.2 1.3 28.0 25.7 22.7 16.2 5.6 4.1 3.4 1.6 1.1 0.8 0.7 0.5 0.5 0.5 0.5 0.4 0.4 0.3 0.2 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 151.6 57.5 28.0 12.1 10.0 5.2 4.4 1.7 1.4 1.4 1.3 0.7 199.6 46.2 12.4 7.6 8.6 2.8 8.6 0.2 3.2 0.2 5.0 0.2 276.5 53.9 16.7 7.0 14.9 3.1 19.2 0.4 6.6 0.4 11.2 0.4 (table continued)

NNW-- 'ESL02014-02 C-28 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C13 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for North Diablo Cove Station NDC 2+0.3m (8+1).Survey 172 173 174 175 Survey Date 25-Feb-t3 30-Apr-13 8-Ju1-13 6-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Epiactis prolifera 0.6 1.3 0.4 0.9 0.2 0.4 1.0 1.2 0.6 Pollicipes polymerus


2.0 4.5 --0.5 Chlorostoma brunnea 1.2 2.2 0.2 0.4 0.2 0.4 --0.4 Serpulidae 1.4 2.2 ----<0.1 <0.1 0.4 Chlorostoma funebralis

--0.8 1.8 0.6 1.3 0.4 Pagurus spp. 0.2 0.4 0.2 0.4 0.6 1.3 0.3 Cyanoplaxspp.

<0.1 <0.1 0.2 0.4 0.6 0.9 0.2 Nuttallina califomica


0.8 1.8 0.2 Mytilus spp. 0.6 1.3 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 0.2 Pugettia spp. --0.2 0.4 0.2 0.4 -0.1 Mopalia spp. 0.2 0.4 ----<0.1 Nereididae

--0.2 0.4 <0.1 Hemigrapsus nudus 0.2 0.4 <0.1 Ophiothrix spiculata 0.2 0.4 --<0.1 Haliotis spp. 0.1 0.3 ------<0.1 Grapsidae

--<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Heptacarpus spp. <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Littorinaspp.

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Lacuna spp. <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 --<0.1 Ischnochitonidae

--<0.1 <0.1 <0.1 <0.1 --<0.1 Lirobittium spp. <0.1 <0.1 --<0.1 <0.1 <0.1 Acmaea mitra --<0.1 <0.1 --<0.1 Majidae <0.1 <0.1 <0.1 Sipuncula

<0.1 <0.1 <0.1 Ophiactis simplex <0.1 <0.1 <0.1 Tylodina fungina <0.1 <0.1 <0.1 Invertebrate Cover Pista spp. 5.6 10.4 6.2 8.4 1.9 4.2 4.0 6.6 4.4 Chthamalus fissus 0.5 0.9 0.2 0.5 0.3 0.5 <0.1 -0.2 Phragmatopoma califomica 0.2 0.7 0.2 0.7 0.3 0.9 0.2 0.7 0.2 Spirorbidae

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 tunicates, compound/social

<0.1 <0.1 --<0.1 <0.1 <0.1 <0.1 <0.1 Dodecaceria fewkesi ----<0.1 <0.1 -<0.1 Porifera (encrusting)

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 bryozoa (encrusting)

<0.1 <0.1 --<0.1 <0.1 <0.1 Salmacina tribranchiata

--<0.1 <0.1 --<0.1 Substrate Cover rock 8.7 8.7 12.4 12.4 13.1 15.4 16.0 14.2 12.6 sand (shell gravel) 1.7 5.5 5.1 7.2 2.5 6.0 9.0 11.9 4.6 cobble 2.6 4.5 1.9 3.4 1.6 2.4 3.0 4.1 2.3 W ESL02014-02 C-29 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C14. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for North Diablo Cove Station NDC 2+0.9m (8+3).Survey 172 173 174 175 Survey Date 28-Jan-13 31-May-13 9-Ju1-13 6-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Cover non-coralline crust 18.0 11.7 9.9 5.7 20.1 12.6 15.6 13.2 15.9 Endocladia muricata 6.0 8.2 15.1 23.1 13.5 20.4 4.6 7.5 9.8 Ulva spp. --9.9 8.7 13.1 10.8 <0.1 <0.1 5.7 Mastocarpus papillatus 0.4 1.3 1.9 3.4 3.8 5.0 2.4 1.8 2.1 coralline crust 2.8 2.2 0.6 0.8 0.5 0.5 2.6 1.6 1.6 Chrysophyta

--0.6 0.7 2.5 7.9 --0.8 filamentous red algae complex 0.3 0.9 0.8 2.4 1.0 2.6 1.0 2.4 0.7 Corallina vancouveriensis 0.4 1.1 0.4 1.1 0.6 1.3 0.4 0.9 0.5 Gelidium coulteri <0.1 0.2 0.6 0.9 0.7 0.8 0.2 0.3 0.4 Gelidiumpusillum

<0.1 <0.1 <0.1 -0.2 0.7 0.7 1.0 0.2 Mazzaella affinis --<0.1 0.2 0.6 0.9 <0.1 0.2 0.2 juv. articulated coralline algae 0.3 0.9 <0.1 <0.1 <0.1 0.2 0.1 0.4 0.1 Codium fragile subsp. Californicum

<0.1 <0.1 ----0.5 0.9 0.1 Calliarthron/Bossiellaspp.-complex

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 0.1 0.4 <0.1 Colpomeniaspp.

--<0.1 <0.1 0.1 0.4 --<0.1 Prionitis spp. --<0.1 <0.1 --<0.1 0.2 <0.1 Cladophoraspp.

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 --<0.1 Porphyraspp.

--<0.1 <0.1 <0.1 <0.1 --<0.1 Chondracanthus canaliculatus

<0.1 <0.1 -<0.1 <0.1 <0.1 <0.1 <0.1 Gastroclonium subarticulatum

---<0.1 <0.1 <0.1 <0.1 <0.1 Pterosiphonia dendroidea

<0.1 <0.1 <0.1 <0.1 ----<0.1 Acrosiphoniaspp.

---<0.1 <0.1 <0.1 Mazzaella leptorhynchos

-<0.1 <0.1 <0.1 Chlorophyta (filamentous)

--<0.1 <0.1 --<0.1 Invertebrate Counts Lottia scabra 84.2 43.8 67.6 27.5 74.6 52.5 192.6 59.9 104.8 Chlorostoma funebralis 144.4 45.4 0.4 0.9 3.4 5.3 112.8 115.7 65.3 Anthopleura elegantissima 43.6 64.4 29.8 36.1 48.0 76.9 33.4 47.5 38.7 Mytilus spp. 28.4 52.6 18.6 33.4 15.4 24.4 21.0 34.7 20.9 Lottia pelta 1.2 2.2 3.6 5.7 4.0 4.7 16.2 17.4 6.3 Lottia gigantea 2.6 4.8 4.6 6.2 3.8 5.3 3.4 5.6 3.6 Pagurus spp. 9.6 9.8 0.4 0.5 0.4 0.5 3.2 3.4 3.4 Strongylocentrotus purpuratus 1.6 2.3 3.0 6.7 5.2 6.1 3.0 4.1 3.2 Lottiidae 3.0 2.6 0.2 0.4 0.6 0.9 6.4 7.9 2.6 Lottia limatula 0.6 0.9 0.8 1.3 2.0 2.8 3.6 2.5 1.8 Lottia scutum 1.8 2.5 0.8 0.8 1.8 2.0 2.2 2.4 1.7 Cyanoplaxspp.

0.8 0.4 0.8 1.8 1.4 2.1 2.2 1.8 1.3 Fissurella volcano 0.2 0.4 0.4 0.9 2.8 1.6 0.8 0.4 1.1 Pachygrapsus crassipes

--0.4 0.5 3.2 1.9 0.6 1.3 1.1 Tetraclita rubescens 0.8 1.8 --0.6 1.3 0.8 0.8 0.6 Mopalia spp. 0.8 0.8 0.4 0.5 --0.4 0.5 0.4 Acanthinucella spp. 0.4 0.5 1.0 1.7 --0.4 Ocinebrina spp. 0.6 0.5 0.6 0.5 0.3 (table continued)

MEW 4 ESL02014-02 C-30 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C14 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for North Diablo Cove Station NDC 2+0.9m (8+3).Survey 172 173 174 175 Survey Date 28-Jan-13 31-May-13 9-Jul-13 6-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Nuttallina califomica 0.2 0.4 0.2 0.4 0.2 0.4 0.2 Strongylocentrotus franciscanus 0.2 0.4 ----<0.1 Littodinaspp.

<0.1 -<0.1 -<0.1 <0.1 <0.1 -<0.1 Grapsidae

-<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Ischnochitonidae

---<0.1 <0.1 --<0.1 Pollicipes polymerus

<0.1 <0.1 --<0.1 Sipuncula

--<0.1 <0.1 <0.1 Homolo. lufidunmLirularia succincta

--<0.1 <0.1 <0.1 Invertebrate Cover Chthamalus fissus 9.5 7.4 11.2 10.6 17.2 12.8 14.8 10.2 13.2 Phragmatopoma califomica 1.9 2.5 0.2 0.7 0.3 0.9 1.5 1.9 1.0 Spirorbidae

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Neosabellaria cementarium


<0.1 ---<0.1 Substrate Cover rock 58.7 11.0 49.7 17.2 28.7 18.3 55.0 16.7 48.0 cobble 1.5 3.0 1.3 3.1 2.3 4.9 2.2 3.1 1.8 sand (shell gravel) 0.1 0.4 <0.1 <0.1 <0.1 <0.1 0.2 0.5 <0.1 MOW ESLO2014-02 C-31 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C15. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for North Diablo Cove Station NDC 3+0.3m (9+1).Survey 172 173 174 175 Survey Date 25-Feb-13 30-Apr-13 8-Jul-13 2-Dec-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Cover non-coralline crust Codium fragile subsp. Californicum coralline crust UOva spp.Codium setchellii Corallina vancouveriensis Pterosiphonia dendroidea filamentous red algae complex Chrysophyta Gelidium coulteri juv. articulated coralline algae Cryptopleura violacea CalliarthronrBossiella spp.-complex Chlorophyta (filamentous)

Gelidium pusillum Colpomenia spp.Grateloupia califomica Macrocystis pyrifera Desmarestia ligulata Farlowia/Pikea spp.-complex Porphyra spp.Cladophora spp.Chondracanthus canaliculatus Mastocarpus papillatus Sarcodiotheca gaudichaudii Prionitis spp.Halymenia/Schizymenia spp. -complex Mazzaella affinis Callithamnion spp./Pleonosporium spp.Acrosiphonia spp.Gastroclonium subarticulatum Callophyllis spp.Polyneura latissima Bryopsis spp.Invertebrate Counts Tetraclita rubescens Lottia scabra Mytilus spp.Strongylocentrotus purpuratus Fissurella volcano Lottia pelta Lottia gigantea Epiactis prolifera 40.7 16.1 15.9 12.7 10.5 5.2 6.9 7.0 6.1 8.1 0.3 0.6 0.7 1.0 7.6 10.3 0.7 1.1 1.9 3.1 0.7 2.2<0.1 <0.1<0.1 <0.1 0.2 0.7 0.2 0.7<0.1 <0.1<0.1 0.2<0.1 0.2<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 346.8 223.9 23.8 19.0 8.0 17.3 22.8 25.2 12.4 13.8 1.6 1.8 4.4 2.3 31.5 24.4 5.8 11.1 6.9 0.4 1.8 2.4 3.3 1.0 0.7 0.2<0.1<0.1<0.1<0.i<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 461.2 63.8 12.8 23.6 31.8 4.0 3.2 3.2 17.6 16.6 4.2 5.4 7.9 1.3 2.2 2.8 5.1 1.3 1.5 0.5<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 345.5 50.5 28.1 25.4 27.5 4.2 30.1 12.6 14.3 30.6 6.5 9.9 2.4 0.8 4.7 2.4 0.5 0.3 0.6<0.1 19.1 6.7 12.2 19.1 8.7 11.6 4.6 1.2 5.3 5.2 0.9 0.7 2.0 0.2 24.5 25.6 9.8 0.3 5.6 1.0 6.5 0.9 3.3 5.2 0.9 1.3 0.2<0.1 21.6 18.6 6.4 0.6 5.3 2.0 7.6 1.6 3.2 7.5 1.0 2.0 0.7<0.1<0.1 0.2<0.1 <0.'I<0.1 0.2<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 31.7 16.5 9.7 8.2 7.7 6.3 2.9 2.8 2.7 2.4 2.2 1.8 0.3 0.3 0.2<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 456.9 35.2 33.8 21.5 18.0 5.7 3.1 2.8 222.2 12.0 10.0 16.4 10.8 5.4 107.1 9.1 18.7 17.6 9.4 1.5 1.9 1.8 797.4 41.2 104.4 23.0 16.8 11.6 277.7 27.9 226.8 20.5 6.0 4.8 1.9 1.4 6.1 1.2 3.4 2.1 6.6 9.6 (table continued) 0'ESLO2014-O2 C-32 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C15 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m') survey means, standard deviations and 2013 annual means for North Diablo Cove Station NDC 3+0.3m (9+ 1).Survey 172 173 174 175 Survey Date 25-Feb-13 30-Apr-13 8-Jul-13 2-Dec-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Pachygrapsus crassipes 0.6 0.9 1.0 1.2 2.8 2.6 2.0 1.2 1.6 Arnthopleura elegantissima 0.6 0.9 1.2 1.3 3.8 5.0 0.8 0.4 1.6 Lottia scutum 0.4 0.5 0.2 0.4 3.6 6.9 1.8 3.0 1.5 Balanus spp. ------5.4 3.6 1.4 Lottia limatula ----1.4 2.1 2.0 3.5 0.9 Serpulidae 0.6 0.9 0.8 1.3 --1.2 1.3 0.7 Ocinebrina spp. --0.4 0.9 1.2 1.3 0.4 Nuttallina califomica

--1.2 1.6 0.3 Nemertea --0.6 1.3 --0.2 Pugettiaspp.

0.4 0.5 <0.1 <0.1 --0.1 Natantia --<0.1 <0.1 0.4 0.9 0.1 Pisasterochraceus 0.2 0.4 --0.2 0.4 0.1 Serpulorbis squamigerus

--0.2 0.4 <0.1 Chlorostoma funebralis

--0.2 0.4 <0.1 Pagurus spp. 0.2 0.4 --<0.1 Strongylocentrotus franciscanus

--0.2 0.4 <0.1 Megathura crenulata

-0.2 0.4 <0.1 Lottiidae

<0.1 <0.1 <0.1 -<0.1 <0.1 <0.1 Ophiactis simplex <0.1 <0.1 -<0.1 <0.1 <0.1 <0.1 <0.1 Ischnochitonidae

<0.1 <0.1 --<0.1 <0.1 <0.1 Heptacarpus spp. --<0.1 <0.1 <0.1 <0.1 <0.1 Lottia ochracea --<0.1 <0.1 <0.1 Hermissenda crassicomis

<0.1 <0.1 --<0.1 Pollicipes polymerus

--<0.1 <0.1 <0.1 Pelecypoda boring <0.1 <0.1 <0.1 Lacuna spp. -<0.1 <0.1 <0.1 Sipuncula

<0.1 <0.1 <0.1 Grapsidae

--<0.1 <0.1 ----<0.1 Invertebrate Cover Phragmatopoma califomica 1.0 0.8 <0.1 -0.6 0.8 3.5 5.1 1.2 Chthamalus fissus 0.1 0.3 <0.1 0.2 0.1 0.3 0.4 0.6 0.2 Spirorbidae

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 -<0.1 tunicates, compound/social

--<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Porifera (encrusting)

<0.1 <0.1 --<0.1 <0.1 <0.1 bryozoa (encrusting)

--<0.1 <0.1 <0.1 Pista spp. --<0.1 <0.1 <0.1 Substrate Cover rock 19.9 11.9 32.2 25.2 21.9 17.8 27.5 19.7 25.4 cobble 2.2 3.9 4.2 4.7 2.6 3.7 2.2 3.6 2.8 sand (shell ravel) <0.1 <0.1 --<0.1 <0.1 <0.1 <0.1 <0.1-- ESL02014-02 C-33 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C16. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for North Diablo Cove Station NDC 3+0.9m (9+3).Survey 172 173 174 175 Survey Date 28-Jan-13 30-Apr-13 8-Jul-13 2-Dec-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Cover non-coralline crust Codium fragile subsp. Californicum Ulva spp.coralline crust Chrysophyta filamentous red algae complex Gelidium coulteri Mastocarpus papillatus Mazzaella affinis Pterosiphonia dendroidea Corallina vancouveriensis Chlorophyta (filamentous)

Gelidium pusillurn juv. articulated coralline algae Colpomenia spp.Cryptopleura violacea Endocladia muricata Prionitis spp.Cladophora spp.Porphyra spp.Bryopsis spp.Calliarthron/Bossiella spp.-complex Macrocystis pyrifera Invertebrate Counts Tetraclita rubescens Lottia scabra Mytilus spp.Strongylocentrotus purpuratus Lottia gigantea Fissurella volcano Lottia pelta Lottiidae Pachygrapsus crassipes Lottia limatula Pagurus spp.Lottia scutum Anthopleura elegantissima Pollicipes polymerus Balanus spp.Serpulidae Nuttallina califomica Ocinebrina spp.Nemertea 33.5 1.5<0.1 1.6 5.1 0.8<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 49.2 71.6 58.0 4.2 14.4 5.6 0.6 0.8 0.4 1.4 0.2 0.2 1.0 2.2 0.2 0.8 0.2 18.4 4.0 0.2 2.2 14.0 2.4 0.2<0.1 0.2<0.1<0.1<0.1<0.1<0.1 49.5 41.3 88.7 6.6 14.4 5.5 0.9 1.3 0.5 2.6 0.4 0.4 1.4 2.2 0.4 1.8 0.4 33.2 19.1 3.7 6.5 7.2 9.8 1.3 1.8<0.1 <0.1 1.0 3.1 0.1 0.3 0.2 0.5<0.1 <0.1<0.1 0.2<0.1 0.2<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 81.0 108.3 75.2 43.5 31.4 36.8 26.8 28.9 19.0 20.4 13.0 15.3 3.6 1.8 1.6 2.6 1.6 1.7 0.4 0.5 1.2 1.6 0.8 1.3 0.8 1.8 0.6 0.9 0.2 0.4<0.1 <0.1 39.7 20.3 6.7 9.6 11.0 9.6 1.7 2.2 1.0 3.3 1.5 4.8 1.2 1.2 0.3 0.7 0.8 2.2 0.7 1.3 0.1 0.3<0.1 <0.1<0.1 <0.1 0.1 0.3<0.1 0.2<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 76.2 103.6 39.0 23.0 40.0 57.6 33.2 40.5 13.0 14.7 13.2 17.9 1.4 1.7 4.6 6.2 3.4 2.7 1.8 2.7 0.2 0.4 0.6 1.3 1.0 1.7 0.4 0.9 0.2 0.4 0.2 0.4 0.2 0.4 40.7 25.5 7.9 11.0<0.1 0.2 2.8. 2.9 2.8 6.6 1.0 1.2 0.3 0.6<0.1 <0.1 0.3 0.6 0.6 2.0 0.5 0.9 0.5 0.9<0.1 <0.1 0.1 0.4<0.1 <0.1<0.1 0.2<0.1 <0.1 135.0 168.5 101.4 59.3 34.8 42.1 10.4 8.7 23.2 22.4 14.6 13.4 9.4 7.6 1.4 1.5 2.4 1.8 3.2 4.9 3.2 4.4 1.8 2.5 1.0 1.7 1.0 1.4 0.8 0.8 0.4 0.5 0.8 1.8 0.4 0.5 36.8 5.0 4.6 1.9 1.5 1.5 0.6 0.2 0.2 0.2 0.2 0.2 0.1 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 85.4 71.8 41.1 18.7 17.4 11.6 3.8 2.1 1.9 1.5 1.2 1.0 0.8 0.7 0.6 0.5 0.4 0.3 0.2 (table continued)

R ES -"LO2014-02 03 C-34 o Appendix C -Intertidal Algae, Invertebrates and Substrates Table C16 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m 2) survey means, standard deviations and 2013 annual means for North Diablo Cove Station NDC 3+0.9m (9+3).Survey 172 173 174 175 Survey Date 28-Jan-13 30-Apr-13

  • 8-Jul-13 2-Dec-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Cyanoplax spp. 0.2 0.4 0.2 0.4 --0.2 0.4 0.2 Pugettia spp. ----0.4 0.9 --0.1 Ophiactis simplex --0.4 0.9 0.1 Pelecypoda boring --<0.1 <0.1 0.2 0.4 <0.1 Mopalia spp. 0.2 0.4 ----<0.1 Serpulorbis squamigerus 0.2 0.4 --<0.1 Chiorostoma brunnea --0.2 0.4 <0.1 Chlorostoma funebralis 0.2 0.4 <0.1 Romaleon antennarius


0.2 0.4 <0.1 Littonrna spp. <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Ischnochitonidae

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Heptacarpus spp. <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 --<0.1 Grapsidae

-<0.1 <0.1 <0.1 <0.1 --<0.1 Barleeia spp. <0.1 <0.1 -<0.1 <0.1 <0.1 Lirobittium spp. <0.1 <0.1 ---<0.1 Ophioplocus esmarki <- -0.1 <0.1 --<0.1 Lacuna spp. <- -0.1 <0.1 <0.1 Sipuncula


<0.1 <0.1 <0.1 Invertebrate Cover Chthamalus fissus 7.2 6.0 6.6 6.1 7.6 10.6 8.8 8.8 7.5 Phragmatopoma califomica 0.8 1.2 0.5 0.7 0.5 0.9 0.3 0.6 0.5 Spirorbidae

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 tunicates, compound/social

--<0.1 <0.1 --<0.1 Porifera (encrusting)


<0.1 <0.1 <0.1 Substrate Cover rock 45.6 23.6 44.8 25.5 34.0 21.0 31.9 17.6 39.1 cobble 3.5 4.9 3.6 5.9 2.2 3.9 1.7 2.8 2.8 sand (shell gravel) <0.1 0.2 --<0.1 <0.1 --<0.1 mwESLO2014-02 C3 C-35 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C17. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for South Diablo Cove Station SDC 1+0.3m (10+1).Survey 172 173 174 175 Survey Date 10-Jan-13 26-Apr-13 23-Jul-13 4-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Cover coralline crust filamentous red algae complex non-coralline crust Chrysophyta Gelidium cou/teri Ulva spp.Prionitis spp.juv. articulated coralline algae Gastroclonium subarticulatum Pterosiphonia dendroidea Sargassum muticum Ciyptopleura violacea Macrocystis pyrifera Chondracanthus canaliculatus Corallina vancouveriensis Mastocarpus papillatus Colpomenia spp.Mazzaella affinis Grateloupia califomica Mazzaella leptorhynchos Silvetia compressa Mastocarpusjardinii Gelidium pusillum Cladophora spp.Laminariales Calliarthron/Bossiella spp.-complex Halymenia/Schizymenia spp.-complex Codium fragile subsp. Californicum Invertebrate Counts Strongylocentrotus purpuratus Anthopleura elegantissima Fissurella volcano Tetraclita rubescens Lottia pelta Cirratulidae[Terebellidae Lottia limatula Ophiothrix spiculata Pachygrapsus crassipes Pagurus spp.Ophiactis simplex Epiactis prolifera Chlorostoma funebralis Lottia scabra 22.4 17.1 25.0 17.8 19.3 12.5 0.1 0.3<0.1 <0.1 0.8 1.3<0.1 0.6 1.3 1.9 4.0 0.3 0.9 0.2 0.5<0.1 <0.1<0.1 <0.1<0.1 <0.1 30.0 30.2 34.8 26.2 30.6 26.2 21.0 25.8 0.8 0.8 1.4 1.3 0.6 1.3 23.6 14.6 11.0 14.6 11.2 10.2 4.0 4.8 0.1 0.3 8.5 7.4 0.3 0.9 0.3 1.1 1.2 3.7 1.0 3.1 0.1 0.4<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 0.3 0.8<0.1 <0.1<0.1 <0.1 52.0 46.8 16.6 5.3 18.6 3.9 8.4 10.7 2.6 2.9 3.4 7.6 1.0 0.7 1.4 1.3 1.0 1.0<0.1 <0.1 0.2 0.4 0.2 0.4 18.9 2.0 12.3 31.3 16.6 5.6 2.2 1.9 1.9 0.2 0.2 0.2 0.9 0.7 0.6 0.5<0.1 0.1<0.1<0.1<0.1<0.1<0.1 21.1 2.5 8.4 19.1 12.9 9.8 3.0 3.6 4.7 0.5 0.7 0.5 2.1 1.2 1.1 0.5<0.1 0.3 0.2 0.2 0.2<0.1<0.1 13.9 5.1 22.6 13.4 13.8 9.9 4.6 13.8<0.1 <0.1 3.6 3.3 4.4 6.4 2.3 6.0 1.9 1.3 1.8 5.0 0.6 0.9<0.1 0.2 0.1 0.4<0.1 0.2<0.1 <0.1<0.1 <0.1 19.7 15.2 14.1 8.8 5.4 3.5 1.7 1.7 1.5 1.0 0.8 0.3 0.2 0.2 0.2 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 42.8 24.8 15.3 9.6 1.7 1.1 0.8 0.8 0.6 0.6 0.4 0.3 0.3 0.3 42.2 29.5 24.4 12.4 7.6 6.6 2.4 3.4 2.0 2.9 0.8 1.1 0.2 0.4 1.6 1.7 1.0 1.2 0.8 0.8 1.4 1.7 0.2 0.4 47.0 23.2 4.2 6.4 1.4 0.6 0.2 0.2 1.4 1.0 1.2 44.2 6.1 3.1 8.8 1.3 0.9 0.4 0.4 1.5 2.2 1.6 (table continued)

CNt No S0040 C-36 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C17 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m 2) survey means, standard deviations and 2013 annual means for South Diablo Cove Station SDC 1+0.3m (10+ 1).Survey 172 173 174 175 Survey Date 10-Jan-13 26-Apr-13 23-Jul-13 4-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Lottia scutum --1.0 1.4 0.3 Nemertea 0.8 0.8 ----0.2 Pisaster ochraceus 0.2 0.4 0.4 0.9 0.2 0.4 0.2 Sipuncula

--0.6 0.9 <0.1 <0.1 0.2 Ophiuroidea 0.4 0.9 --<0.1 <0.1 0.1 Cyanoplax spp. --0.4 0.9 --0.1 Mopalia spp. --0.4 0.9 0.1 Chaetopteridae

--0.4 0.9 0.1 Anthdpleura artemisia 0.2 0.4 <0.1 <0.1 <0.1 Pugettia spp. 0.2 0.4 <0.1 <0.1 <0.1 Diodora spp. 0.2 0.4 ----<0.1 Serpulorbis squamigerus 0.2 0.4 <0.1 Chlorostoma brunnea 0.2 0.4 <0.1 Bivalvia ----0.2 0.4 <0.1 Hermissenda crassicornis 0.2 0.4 --<0.1 Patiria miniata --0.2 0.4 <0.1 Strongylocentrotus franciscanus 0.2 0.4 ---<0.1 Lottiidae

<0.1 -<0.1 <0.1 <0.1 <0.1 <0.1 Barleeia spp. <0.1 -<0.1 <0.1 -<0.1 Lacuna spp. -<0.1 <0.1 <0.1 <0.1 <0.1 -<0.1 Alia spp. -<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Ischnochitonidae

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 --<0.1 Amphipholis squamata ----<0.1 <0.1 <0.1 Pelecypoda boring --<0.1 <0.1 <0.1 Octopus spp. <0.1 <0.1 -<0.1 Doriopsilla albopunctata

<0.1 <0.1 --<0.1 Lirobittium spp. -<0.1 <0.1 <0.1 Isopoda <0.1 <0.1 <0.1 Heptacarpus spp. <0.1 <0.1 <0.1 Grapsidae

<0.1 <0.1 <0.1 Invertebrate Cover Pista spp. 0.3 0.9 ---<0.1 Spirorbidae

--<0.1 <0.1 0.3 0.9 <0.1 <0.1 <0.1 Phragmatoporna califomica

<0.1 <0.1 <0.1 <0.1 --0.1 0.4 <0.1 Chthamalus fissus <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Porifera (encrusting)

<0.1 <0.1 ------<0.1 bryozoa (encrusting)

--<0.1 <0.1 <0.1 <0.1 --<0.1 Substrate Cover rock 15.5 4.9 32.8 14.4 5.7 5.8 17.8 11.4 18.0 cobble 10.3 7.6 9.2 12.6 2.4 3.3 5.8 5.7 6.9 sand (shell gravel) 2.6 3.9 0.4 0.5 5.0 8.4 1.1 1.4 2.3--W ESLO2014-02 C-37 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C18. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M2) survey means, standard deviations and 2013 annual means for South Diablo Cove Station SDC 1+0.6m (10+2).Survey 172 173 174 175 Survey Date 10-Jan-13 26-Apr-13 23-JuS-13 4-Nov.13 Std. Stda Std. Std1 Annual Taxon Mean Dev. Mean Dev. Mean Dev, Mean Dev. Mean Algae Cover non-coralline crust filamentous red algae complex Gelidium coulteri coralline crust Gastroclonium subarticulatum Ulva spp.Chrysophyta Prionitis spp.Chondracanthus canaliculatus Pterosiphonia dendroidea Cryptopleura violacea juv. articulated coralline algae Mazzaella affinis Mastocarpus papillatus Gelidium pusillum Mastocarpus jardinii Mazzaella leptorhynchos Coral/ina vancouveriensis Colpomenia spp.Cladophora spp.Grateloupia californica Scytosiphon spp.Calliarthron/Bossiella spp.-complex Mazzaella oregona Microcladia coufteri HalymenialSchizymenia spp.-complex Bryopsis spp.Macrocystis pyrifera Endarachne/Petalonia-complex Invertebrate Counts Anthopleura elegantissima Tetraclita rubescens Strongylocentrotus purpuratus Fissurella volcano Lottia pelta Lottia limatula Pagurus spp.Lottia scabra Pachygrapsus crassipes Chaetopteridae Pugettia spp.Pisaster ochraceus Lottia scutum 32 28 4 7 3<0 1 0 0 0<0 0<0 0<0<0 46 42 6 16 1.2 0 0<0 0 0.9 6.0.8 11.1.7 4.6.5 6.6.8 4.0.1 <0.1.0 2.3.6 0.8.7 0.9.3 0.8.1 <0.1.3 0.9.1 <0.1.7 1.3.1 <0.1.1 <0.1.8 22.9.4 46.5.6 3.9.8 11.6.0 1.4.0 2.3.2 0.4.2 0.4.1 <0.1.4 0.5.2 0.4 19.9 20.6 3.4 11.9 4.0 13.7 0.2 0.4<0.1<0.1 0.3 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 31.8 29.0 11.2 12.2 6.4 2.4 3.4 1.0 0.6 0.2 8.8 8.1 3.8 10.1 5.0 8.5 0.7 1.1<0.1 0.2 0.7 0.4<0.1<0.1<0.1<0.J<0.1<0.1<0.1<0.1 22.0 60.4 9.7 9.3 1.5 1.1 2.3 1.2 1.3 0.4 24.9 8.5 0.4 0.7 25.0 7.8 6.5 8.6 5.6 6.7 6.6 4.2 18.0 10.9 4.2 4.1 1.5 1.8<0.1 <0.1 0.7 1.1 0.8 2.0 0.6 0.9 0.9 1.4<0.1 0.2 0.1 0.3<0.1 0.2<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 35.5 12.0 8.3 13.3 15.7 10.2 9.2 6.6 9.1 9.1<0.1 <0.1 4.7 5.3 1.7 2.0 3.1 4.5 1.7 2.0 0.9 1.9<0.1 0.2<0.1 <0.1 0.1 0.4 0.1 0.3<0.1 0.2<0.1 <0.1<0.1 <0.1<0.1 <0.1 38.4 13.9 31.6 49.8 18.8 17.3 4.6 2.9 1.2 1.3 1.2 1.6 1.8 2.9 1.0 1.4 0.2 0.4 0.6 0.9 0.2 0.4 28.3 14.5 12.2 8.8 5.6 5.1 4.5 2.6 1.0 0.9 0.7 0.5 0.3 0.2 0.2<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 38.2 28.2 16.2 9.6 2.3 1.8 1.5 1.4 0.6 0.5 0.4 0.3 0.2 35.6 9.6 28.2 4.6 0.6 1.6 4.2 1.0 1.2 1.0 1.2 0.4 13.8 14.6 23.8 3.4 0.9 1.1 6.7 1.7 0.8 2.2 1.8 0.9 I (table continued)

MWESLO2014-02 03 C-38 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C18 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for South Diablo Cove Station SDC 1+0.6m (10+2).Survey 172 173 174 175 Survey Date 10-Jan-13 26-Apr-13 23-Jul-13 4-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Ophiothrix spiculata Nemertea Chlorostoma funebralis Cyanoplax spp.Chlorostoma brunnea Leptasterias spp.Ocinebrina spp.Serpulidae Lottiidae Barleeia spp.Littorina spp.Lacuna spp.Epitoniumn/Opalia spp.Pelecypoda borng Alia spp.Pseudomelatoma torosa Ischnochitonidae Strongylocentrotus spp.Heptacarpus spp.Sipuncula Mytilus spp.Ophiactis simplex Invertebrate Cover Pista spp.Chthamalus fissus Spirorbidae Phragmatopoma califomica Porifera (encrusting) tunicates, compound/social Substrate Cover rock cobble sand (shell oravelh 0.2 0.4 0.2 0.4<0.1<0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 0.4 0.5 0.2 0.4 0.2 0.4 0.2 0.4<0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 0.4 0.2<0.1<0.1<0.1<0.1<0.1 0.9 0.4<0.1<'0.1<0.1 0.2 0.2 0.2<0.1<0.1<0.1<0.1<0.1<0.1<0.1 0.3<0.1<0.1 5.8 2.6 2.5 0.4 0.4 0.4<0.1<0.1<0.1<0.1<0.1 0.2 0.7<0.1<0.1 3.9 3.5 3.2 0.2 0.1 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 0.2<0.1<0.1<0.1<0.1<0.1 9.4 5.6 3.4 0.6<0.1<0.1<0.1<0.1 11.2 7.2 6.2 1.1<0.1<0.1 6.6 8.1 7.4<0.1<0.1<0.1<0.1 16.5 9.2 3.0 0.2<0.1<0.1<0.1 8.9 13.0 5.0<0.1<0.1 <0.1 4.2 4.1 3.5 4.1 2.0 3.1 0WESLO2014-02 C-39 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C19. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for South Diablo Cove Station SDC 2+0.3m (11+1).Survey 172 173 174 175 Survey Date 8-Jan-13 24-Apr-13 22-Jul-13 5-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Cover non-coralline crust 41.5 20.8 13.0 6.7 28.7 14.0 51.8 18.6 33.7 filamentous red algae complex 12.8 23.5 12.8 23.5 9.1 22.1 6.0 13.1 10.2 Ulvaspp. <0.1 <0.1 13.5 11.4 26.4 16.3 <0.1 <0.1 10.0 Chrysophyta

--28.6 14.5 ----7.2 coralline crust 9.4 6.4 7.9 9.6 3.4 2.7 5.4 3.3 6.5 Prionitis spp. 4.5 8.2 3.5 3.9 8.1 9.3 6.1 5.7 5.5 Gelidium coulteri <0.1 <0.1 3.0 3.2 7.8 11.8 0.7 1.1 2.9 Corallina vancouveriensis 2.6 2.5 2.2 3.7 1.3 2.0 3.1 2.8 2.3 Gelidium pusillum 2.3 1.7 --<0.1 <0.1 5.8 6.0 2.0 Mastocarpus papillatus 1.2 2.4 <0.1 <0.1 4.5 8.2 2.0 2.1 1.9 juv. articulated coralline algae <0.1 -<0.1 <0.1 2.8 3.2 2.8 4.0 1.4 Gastroclonium subarticulaturn 0.6 1.1 0.3 1.1 2.4 4.1 1.3 2.4 1.2 Pterosiphonia dendroidea 2.3 2.7 ------0.6 Chondracanthus canaliculatus 0.4 0.7 0.1 0.4 0.3 0.5 0.4 0.9 0.3 Ciyptopleura violacea 0.4 0.6 <0.1 <0.1 0.7 0.9 <0.1 0.2 0.3 Macrocystis pyrifera -<0.1 <0.1 0.7 2.2 --0.2 Chondria decipiens 0.2 0.7 --<0.1 Mastocarpusjardinii

--0.1 0.3 <0.1 Mazzaella affinis <0.1 <0.1 <0.1 0.2 <0.1 <0.1 <0.1 Cladophora spp. <0.1 <0.1 ------<0.1 Calliarthron/Bossiella spp.-complex

---<0.1 <0.1 <0.1 <0.1 <0.1 Colpomeniaspp.

--<0.1 <0.1 ,0.1 <0.1 --<0.1 Sargassum muticum <0.1 <0.1 <0.1 <0.1 -<0.1 Mazzaella leptorhynchos

<0.1 <0.1 --<0.1 Grateloupia californica

--<0.1 <0.1 <0.1 Halymenia/Schizymenia spp.-complex

-<0.1 <0.1 <0.1 Chlorophyta (filamentous)


<0.1 <0.1 <0.1 Invertebrate Counts Anthopleura elegantissima 34.6 5.9 31.0 6.8 29.2 9.5 50.0 18.0 36.2 Chlorostorna funebralis 25.6 19.4 ----37.6 41.7 15.8 Tetraclita rubescens 24.0 47.0 10.4 16.8 7.2 16.1 13.8 14.9 13.9 Lottia limatula 2.4 1.1 2.4 3.2 6.8 4.3 1.6 1.8 3.3 Lottia pelta 1.0 0.7 2.8 2.3 1.4 2.2 2.4 2.7 1.9 Pagurus spp. 2.2 2.5 0.2 0.4 2.0 1.9 0.8 1.3 1.3 Fissurella volcano 1.0 1.0 1.6 2.1 0.4 0.5 0.6 0.5 0.9 Pachygrapsus crassipes 0.2 0.4 1.0 1.0 2.4 1.1 --0.9 Strongylocentrotus purpuratus 0.4 0.9 0.6 1.3 1.4 2.6 0.8 1.8 0.8 Lottia scabra --0.8 1.3 0.8 0.4 0.6 0.9 0.6 Cyanoplax spp. 0.2 0.4 0.2 0.4 1.6 1.9 --0.5 Lottia scuturn ----1.6 2.2 0.2 0.4 0.5 Pisaster ochraceus 0.2 0.4 0.2 0.4 0.6 1.3 0.8 1.3 0.5 Chaetopteridae 0.4 0.9 --0.8 1.8 <0.1 <0.1 0.3 Cirratulidae/Terebellidae

--0.8 1.8 -0.2 (table continued) mm ' ESL02014-02 C-40 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C19 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for South Diablo Cove Station SDC 2+0.3m (11+1).Survey 172 173 174 175 Survey Date 8-Jan-13 24-Apr-13 22-Jul-13 5-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Mopalia spp.Pugettia spp.Pelecypoda boring Acanthinucella spp.Diopatra ornata Balanus spp.Leptasterias spp.Ophiothrix spiculata Haliotis spp.Lottiidae Sipuncula Epitonium/Opalia spp.Ischnochitonidae Barleeia spp.Nereididae Amphissa spp.Ophiactis simplex Homolo. luridum/Lirulafia succincta Invertebrate Cover Chthamalus fissus Spirorbidae Phragmatopoma califomica Pista spp.Dodecaceria fewkesi Porifera (encrusting)

Salmacina tribranchiata Substrate Cover rock sand (shell gravel)cobble 0.2 0.4 0.2 0.4 0.2 0.4<0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 15.8 18.6 5.4 9.7 0.5 1.0 0.2 0.4 0.2 0.4<0.1<0.1 <0.1<0.1 <0.1<9.1 <0.1<0.1 <0.1 11.5 11.5 4.1 5.6 0.1 0.4 0.2 0.4 0.2<0.1<0.1<0.1<0.1<0.1 0.6<0.1<0.1<0.1 1.8 6.2 0.1 0.4 0.9 0.4<0.1<0.1<0.1<0.1 1.5<0.1<0.1 2.6 7.4 0.4 0.2 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 5.6 5.5 1.9 0.4 0.3<0.1<0.1<0.1<0.1<0.1<0.1<0.1 4.1 7.5 3.3 0.1 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 0.1<0.1<0.1<0.1<0.1<0.1<0.1 8.7 5.3 0.7 0 M-W ESLO2014-02 C-41 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C20. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for South Diablo Cove Station SDC 2+0.9m (11+3).Survey 172 173 174 175 Survey Date 8-Jan-13 8-Apr-13 22-Jul-13 5-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Cover non-coralline crust Mastocarpus papillatus Prionitis spp.Gelidium coulteri Gelidium pusillum Corallina vancouveriensis Endocladia muricata coralline crust Grateloupia californica Mastocarpus jardinii juv. articulated coralline algae Cryptopleura violacea filamentous red algae complex Ulva spp.Mazzaella affinis Chondracanthus corymbiferus Cladophora spp, Mazzaella leptorhynchos Pterosiphonia dendroidea Invertebrate Counts Anthopleura elegantissirna Chlorostoma funebralis Tetraclita rubescens Pagurus spp.Lottia scabra Lottia pelta Lottia limatula Lottia scutum Strongylocentrotus purpuratus Pachygrapsus crassipes Pisaster ochraceus Cyanoplax spp.Acanthinucella spp.Hemigrapsus nudus Romaleon antennarius Leptasterias spp.Mytilus spp.Lottiidae Littorina spp.Grapsidae Epitonium/Opalia spp.Ischnochitonidae Isoooda 25.2 21.8 0.9 2.0 2.2 3.8<0.1 <0.1 0.8 1.1 0.4 0.7 0.5 1.3 0.3 0.6<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 27.1 3.7 2.3 0.8<0.1 0.7 0.4 0.2 0.4<0.1<0.1<0.1<0.1 18.5 5.7 3.6 1.2<0.1 1.3 1.3 0.5 0.9<0.1<0.1<0.1<0.1 24.1 7.6 1.7 2.8 0.3 0.2 0.2<0.1<0.1 0.4 0.1 0.1<0.1<0.1<0.1<0.1<0.1 23.2 8.0 2.2 3.9 1.1 0.5 0.7 0.2<0.1 0.9 0.4 0.4 0.2 0.2 0.2<0.1<0.1 26.9 22.8 2.8 3.1 2.6 3.0 0.2 0.3 1.0 1.4<0.1 0.2 0.2 0.3 0.1 0.4 25.8 3.8 2.2 0.9 0.5 0.3 0.3 0.2 0.1 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 55.0 121.6 60.4 20.2 2.2 1.6 2.0 2.2 0.2 0.4 0.4 0.2 0.2 0.2<0.1<0.1 67.5 70.2 108.4 13.3 1.6 1.7 1.9 2.7 0.4 0.5 0.9 0.4 0.4 0.4<0.1 99.2 116.6 91.2 68.0 0.8 1.8 4.6 3.9 4.4 3.0 1.0 1.0 1.4 1.1 1.8 2.9 0.2 0.4<0.1 <0.1<0.1<0.1 <0.1 253.2 420.4 146.4 146.7 6.4 10.4 2.6 1.3 5.6 7.2 0.6 0.9 1.4 1.1 3.0 6.7 2.8 1.8 0.4 0.5 0.6 1.3 0.2 0.4<0.1<0.1 <0.1<0.1 <0.1 133.2 103.6 5.6 0.2 2.6 0.6 0.2 0.8 0.6 0.6 0.2<0.1<0.1<0.1 145.6 81.4 2.1 0.4 4.8 1.3 0.4 1.8 0.9 1.3 0.4<0.1<0.1 135.2 115.7 16.9 8.3 3.1 1.5 1.4 1.1 1.0 1.0 0.4 0.2<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 (table continued) fA--MNW'WES LO2014-02 C-42 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C20 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m 2) survey means, standard deviations and 2013 annual means for South Diablo Cove Station SDC 2+0.9m (11+3).Survey 172 173 174 175 Survey Date 8-Jan-13 8-Apr-13 22-Jul-13 5-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Cover Chthamalus fissus 0.6 0.7 0.5 0.7 2.5 2.4 1.9 4.1 1.4 Phragmatopoma califomica

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Spirorbidae

<0.1 <0.1 --<0.1 <0.1 --<0.1 Substrate Cover rock 52.6 24.2 44.0 23.2 41.0 25.7 33.4 19.8 42.7 sand (shell gravel) 10.8 13.2 14.4 19.0 13.2 13.0 22.0 19.8 15.1 cobble 2.6 2.6 2.4 7.0 2.2 4.2 0.8 1.5 2.0ESLO2014-02 C-43 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C21. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for South Diablo Cove Station SDC 3+0.3m (12+1).Survey 172 173 174 175 Survey Date 20-Feb-13 25-Apr-13 8-Aug-13 21-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Cover non-coralline crust 59.7 24.7 38.5 24.4 10.6 3.8 62.8 9.7 42.9 Ulva spp. <0.1 <0.1 4.0 4.3 52.8 13.3 <0.1 <0.1 14.2 Mastocarpus papillatus 5.7 5.6 2.4 4.0 7.0 6.9 4.2 5.8 4.8 Chrysophyta

--13.5 12.5 ----3.4 Gelidium coulteri 1.7 4.3 0.3 0.7 1.1 1.9 0.3 0.8 0.9 Endocladia muricata 1.7 4.0 0.4 0.9 0.1 0.4 1.0 2.3 0.8 Gelidium pusillurn 0.5 1.3 0.6 1.3 <0.1 -1.6 2.2 0.7 Mazzaella affinis 0.1 0.4 0.3 0.6 1.5 1.7 <0.1 0.2 0.5 Colpomenia spp. ----0.7 1.0 --0.2 Prionitis spp. 0.1 0.4 -0.3 0.9 0.1 0.3 0.1 coralline crust 0.4 0.9 <0.1 <0.1 -<0.1 0.2 0.1 Chondracanthus canaliculatus 0.1 0.4 <0.1 <0.1 0.2 0.7 <0.1 <0.1 <0.1 Gastrocloniumsubarticulatum

<0.1 <0.1 --<0.1 0.2 <0.1 <0.1 <0.1 Cladophoraspp.

--<0.1 <0.1 <0.1 -<0.1 <0.1 <0.1 Mazzaella leptorhynchos

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 --<0.1 Cystoseira osmundacea

---<0.1 <0.1 -<0.1 Corallina vancouveriensis

<0.1 <0.1 -<0.1 <0.1 <0.1 <0.1 <0.1 Porphyra spp. --<0.1 <0.1 --<0.1 Cryptopleura violacea <0.1 <0.1 --<0.1 Calliarthron/Bossiella spp.-complex

--<0.1 <0.1 <0.1 Invertebrate Counts Tetrac/itarubescens 66.8 57.0 145.4 130.7 9.8 13.3 86.4 107.0 77.1 Pagurus spp. 63.2 41.1 11.2 10.6 15.2 7.9 34.6 35.9 31.1 Ch/orostoma funebralis 29.8 30.2 5.2 8.9 3.0 5.7 15.4 21.3 13.4 Strongylocentrotus purpuratus 0.2 0.4 5.8 3.5 20.2 14.7 7.4 7.9 8.4 Anthopleura elegantissima 7.4 6.9 5.0 6.9 7.2 8.5 6.6 3.1 6.6 Lottia limatula 0.8 1.8 0.8 1.3 3.0 0.7 4.2 3.9 2.2 Lottia scabra --4.2 5.2 0.4 0.9 0.4 0.9 1.3 Pachygrapsus crassipes

--2.8 3.6 1.0 1.4 1.2 1.6 1.3 Lottia pelta 0.4 0.9 1.8 1.6 1.4 0.5 1.2 1.6 1.2 Lottia scutum 1.0 1.7 1.2 2.2 --1.4 1.3 0.9 Fissurella volcano 0.6 0.9 0.4 0.5 1.8 1.1 0.2 0.4 0.8 Chlorostoma brunnea 0.2 0.4 1.8 2.5 ----0.5 Pisaster ochraceus 0.6 1.3 0.2 0.4 0.4 0.5 0.2 0.4 0.4 Nereididae

--0.2 0.4 0.4 0.9 --0.2 Anthopleura xanthogrammica 0.2 0.4 --<0.1 Leptasterias spp. --0.2 0.4 -<0.1 Lottiidae

<0.1 <0.1 <0.1 <0.1 -<0.1 <0.1 Littorinaspp.

<0.1 <0.1 ----<0.1 Patinia miniata --<0.1 <0.1 <0.1 <0.1 <0.1 Grapsidae

--<0.1 <0.1 <0.1 Homolo. luridur/Lirularia succincta

--<0.1 <0.1 <0.1 <0.1 <0.1 Alia spp. <0.1 <0.1 <0.1 (table continued) 4"- ESL02014-02 C-44 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C21 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for South Diablo Cove Station SDC 3+0.3m (12+ 1).Survey 172 173 174 175 Survey Date 20-Feb-13 25-Apr-13 8-Aug-13 21-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Epitonium/Opalia spp. <0.1 <0.1 <0.1 Heptacarpus spp. <0.1 <0.1 <0.1 Sipuncula

<0.1 <0.1 <0.1 Invertebrate Cover Chthamalus fissus 0.5 0.9 0.1 0.3 <0.1 <0.1 <0.1 <0.1 0.2 Spirorbidae

<0.1 <0.1 <0.1 <0.1 <0.1 -<0.1 <0.1 <0.1 Phragmatopoma califomica

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Pista spp. <0.1 <0.1 ----<0.1 <0.1 <0.1 Substrate Cover cobble 12.5 6.8 18.9 8.0 15.4 6.9 15.6 7.1 15.6 rock 16.3 21.6 18.1 17.2 7.2 5.0 12.8 8.3 13.6 sand (shell gravel) 0.9 0.8 6.2 8.6 5.1 1.2 3.5 2.7 3.9ESLO2014-02 C-45 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C22. Intertidal algae., sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 , 2) survey means, standard deviations and 2013 annual means for South Diablo Cove Station SDC 3+0.9m (12+3).Survey 172 173 174 175 Survey Date 20-Feb-13 8-Apr-13 8-Aug-13 21-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Cover non-coralline crust Mastocarpus papillatus Ulva spp.Endocladia muricata Gelidium pusillurn coralline crust Gelidium coulteri Corallina vancouveriensis Cladophora spp.Mazzaella affinis Mazzaella leptorhynchos Prionitis spp.juv. articulated coralline algae Gastrocloniurn subarticulatum Invertebrate Counts Chlorostorna funebra/is Anthop/eura e/egantissima Tetraclita rubescens Pagurus spp.Lottia scabra Lottia limatula Lottia scutum Lottia pelta Pachygrapsus crassipes Pisaster ochraceus Acanthinucella spp.Ocinebrina spp.Nemertea Fissurella volcano Lottiidae Littor/na spp.Epitoniurr/Opa/ia spp.Grapsidae Cyanoplax spp.Pollicipes polymerus Ischnochitonidae Lacuna spp.Invertebrate Cover Chthamalus fissus Phragmatopoma californica Spirorbidae 45.3 6.7 1.8<0.1 0.1<0.1<0.1<0.1<0.1<0.1 71.4 115.0 2.0 7.2 6.8 0.4 0.4 0.6 0.2 0.2<0.1<0.1<0.1<0.1 26.9 4.2 5.5<0.1 0.4<0.1<0.1<0.1<0.1<0.1 40.8 226.8 3.5 7.0 14.7 0.5 0.5 0.9 0.4 0.4<0.1<0.1<0.1<0.1 39.7 18.7 9.9 6.7 1.8 4.1<0.1 0.1 0.4<0.1 0.2 0.2 0.7<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 140.4 98.9 37.6 33.7 11.4 19.1 25.2 15.1 14.0 20.7 1.8 2.5 0.2 0.4 0.4 0.5 0.2 0.4 0.2 0.4<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 0.7 1.0<0.1 <0.1<0.1 <0.1 21.2 12.7 20.1 8.5 10.6 12.4 0.6 1.3 0.4 0.9<0.1 <0.1 0.3 0.6<0.1 <0.1<0.1 <0.1 31.0 15.4 8.0 6.5<0.1 <0.1 1.9 4.2 0.1 0.4 0.3 0.9<0.1 0.2<0.1 <0.1<0.1 <0.1<0.1 <0.1 143.6 27.4 36.2 40.2 49.6 2.2 2.8 0.8 0.8 0.4 0.2<0.1<0.1<0.1<0.1<0.1 0.7<0.1<0.1 167.0 35.9 71.3 25.4 54.8 1.6 3.9 0.8 0.4 0.5 0.4<0.1<0.1<0.1<0.1 2.0<0.1<0.1 105.4 52.4 77.0 18.2 19.6 5.0 0.4 1.2 0.4 0.6 0.2<0.1<0.1<0.1 69.0 30.4 171.6 17.2 35.9 5.7 0.5 0.8 0.9 1.3 0.4<0.1<0.1 34.3 11.2 2.6 1.5 0.1 0.1 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 115.2 58.1 31.7 22.7 22.5 2.4 1.0 0.6 0.5 0.3 0.1 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 0.9<0.1<0.1 1.4 2.6<0.1 <0.1<0.1 <0.1 0.7 0.9<0.1 <0.1<0.1 <0.1 (table continued)

'NOWESLO2014-02 C-46 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C22 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for South Diablo Cove Station SDC 3+0.9m (12+3).Survey 172 173 174 175 Survey Date 20-Feb-13 8-Apr-13 8-Aug-13 21-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Substrate Cover rock 31.4 26.1 27.3 21.4 26.2 22.6 37.5 22.1 30.6 cobble 11.9 6.6 16.0 15.3 15.6 7.4 12.6 9.4 14.0 sand (shell gravel) 1.6 1.4 3.6 2.1 5.8 4.0 5.8. 4.1 4.2 0 ESLO2014-02 C-47 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C23. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for South Diablo Point Station SDP 1+0.9m (22+3).Survey 172 173 174 175 Survey Date 14-Jan-13 24-Apr-13 24-Jul-13 18-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Cover non-coralline crust Gelidium coulteri coralline crust Corallina vancouveriensis Egregia menziesii Mastocarpus jardinii juv. articulated coral/ine algae Ulva spp.Mazzaella flaccida Endocladia muricata Prionitis spp.Mastocarpus papillatus Gelidium pusillum Cryptopleura violacea Corallina chilensis Chondracanthus canaliculatus Calliarthron/Bossiella spp.-complex Mazzaella affinis Codium fragile subsp. Californicum Gelidium robustum Chondracanthus corymbiferus Cladophora spp.Porphyra spp.Callithamnion spp./Plecnosporium spp.Scytosiphon spp.Mazzaella oregona Microcladia borealis Osmundea spp.Bryopsis spp.Chrysophyta Invertebrate Counts Anthopleura elegantissima Tetraclita rubescens Strongylocentrotus purpuratus Lottia scabra Fissurella volcano Lottia gigantea Lottia pelta Pisaster ochraceus Nemertea Leptasterias spp.Anthopleura xanthogrammica Pachygrapsus crassipes 47.5 20.3 8.0 5.2 10.5 4.8 11.9 8.1 6.5 4.7 2.5 1.7 5.7 4.8<0.1 <0.1 0.1 0.4 0.6 2.0 0.4 0.9 0.2 0.3 0.3 0.9 0.1 0.4<0.1 0.2 0.2 0.7<0.1 <0.1<0.1 <0.1<0.1 <0.1 64.6 39.8 67.8 47.8 64.4 39.3 8.4 10.1 9.0 3.5 6.8 8.7 6.4 4.0 3.4 3.0 0.4 0.5 2.4 2.5 1.2 0.8 0.4 0.5 51.7 22.2 7.5 3.8 11.9 7.2 10.2 7.4 1.9 2.4 1.8 2.1 0.5 1.5 2.8 3.2 1.3 1.6 0.5 1.5 0.1 0.4 0.1 0.4<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1<0.1 <0.1 30.9 40.7 2.4 2.6 11.3 6.0 0.6 4.9 2.2 0.6 0.6 0.3 0.1 0.3 0.6 0.5<0.1 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 79.8 61.4 37.8 8.6 3.4 3.6 3.6 4.4 0.8 0.2 1.2 1.8 20.2 8.8 1.7 2.6 7.9 4.5 0.9 7.8 2.0 2.0 0.9 0.5 0.3 0.9 1.1 0.6<0.1 0.4<0.1 0.2 0.2<0.1<0.1<0.1<0.1<0.1 60.6 90.0 20.9 14.9 2.4 2.5 2.7 2.9 1.3 0.4 1.3 1.5 51.7 14.4 11.6 7.8 5.6 1.5 1.0<0.1 0.1 0.8 0.3 0.1 0.3 0.2<0.1<0.1<0.1<0.1 88.4 51.4 59.6 11.6 4.6 3.0 3.8 2.0 1.6 0.8 1.2 0.6 23.6 8.3 6.6 5.5 6.0 1.5 1.0<0.1 0.3 1.7 0.5 0.4 0.5 0.7<0.1<0.1 0.2 55.4 38.0 38.8 17.6 4.2 3.0 2.4 2.5 1.5 1.3 1.3 0.5 45.5 17.6 9.1 8.1 6.3 3.0 1.9 1.9 0.9 0.6 0.3 0.2 0.2 0.2 0.2 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 80.4 68.9 62.4 8.7 4.7 4.3 4.1 3.0 1.4 1.2 1.1 1.1 88.8 95.0 87.8 6.0 1.6 3.8 2.4 2.0 2.6 1.2 0.8 1.4 76.5 131.2 96.8 5.6 2.1 2.3 2.6 2.0 2.6 1.6 0.8 0.9 (table continued) 0k--O ESLO2014-02 C-48 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C23 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m 2) survey means, standard deviations and 2013 annual means for South Diablo Point Station SDP 1+0.9m (22+3).Survey 172 173 174 175 Survey Date 14-Jan-13 24-Apr-13 24-Jul-13 18-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Lottia/imatula 1.2 1.1 0.2 0.4 1.2 1.1 1.0 0.7 0.9 Lottia scutum 0.4 0.9 --1.4 1.3 0.2 0.4 0.5 Nuttallina califomica 0.8 0.8 0.4 0.5 ----0.3 Lottia ochracea --<0.1 <0.1 0.8 1.3 --0.2 Pollicipespolymerus

<0.1 <0.1 <0.1 <0.1 0.6 1.3 <0.1 <0.1 0.2 Balanus spp. ------0.6 1.3 0.2 Mytilusspp.

<0.1 <0.1 0.4 0.9 --0.1 Cyanoplax spp. <0.1 <0.1 0.4 0.5 0.1 Nucella spp. 0.4 0.5 ----0.1 Serpulidae

--0.2 0.4 --0.2 0.4 0.1 Sipuncula

<0.1 <0.1 <0.1 <0.1 0.2 0.4 <0.1 <0.1 <0.1 Mopalia spp. --0.2 0.4 ----<0.1 Chiorostoma brunnea 0.2 0.4 ----<0.1 Chlorostoma funebralis

--0.2 0.4 <0.1 Polychaeta 0.2 0.4 <0.1 Pugettia spp. --0.2 0.4 <0.1 Cirratulidae/Terebellidae

-0.2 0.4 --<0.1 Lottiidae

<0.1 <0.1 -<0.1 -<0.1 <0.1 Grapsidae

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 -<0.1 Ischnochitonidae

<0.1 <0.1 --<0.1 <0.1 <0.1 <0.1 <0.1 Pelecypoda boring <0.1 <0.1 <0.1 <0.1 -<0.1 <0.1 <0.1 Acmaea mitra <0.1 <0.1 <0.1 <0.1 -<0.1 Pycnogonida

<0.1 <0.1 <0.1 <0.1 --<0.1 Tonicella lineata ----<0.1 <0.1 <0.1 Littorina spp. <0.1 <0.1 --<0.1 Patiria miniata --<0.1 <0.1 <0.1 Lirobittium spp. <0.1 <0.1 <0.1 Pisasterspp.


<0.1 <0.1 --<0.1 Invertebrate Cover Chthamalus fissus 0.2 0.7 0.1 0.3 0.1 0.3 0.1 0.4 0.2 Phragmatopoma califomica 0.5 1.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 0.1 Dodecaceria fewkesi <0.1 02 0.1 0.4 <0.1 <0.1 <0.1 0.2 <0.1 Spirorbidae

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Salmacina tribranchiata

<0.1 <0.1 <0.1 <0.1 --<0.1 <0.1 <0.1 Porifera (encrusting)

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 --<0.1 Substrate Cover rock 3.3 4.2 4.4 7.8 0.8 1.3 3.0 2.7 2.9 cobble <0.1 <0.1 <0.1 <0.1 <0.1 m-- ESLO2014-02 C-49 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C24. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m 2) survey means, standard deviations and 2013 annual means for South Diablo Point Station SDP 2+0.9m (14+3).Survey 172 173 174 175 Surey Date 14-Jan-13 25-Apr-13 24-Jul-13 18-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Cover coralline crust 30.9 9.5 33.1 16.0 11.1 8.5 28.3 14.5 25.9 Corallina vancouveriensis 14.7 8.6 21.0 13.2 14.7 10.0 15.5 8.2 16.5 Gelidiumcoulteri 10.1 6.6 8.0 6.9 20.5 14.0 11.9 9.9 12.6 Prionitis spp. 4.7 7.8 5.7 8.7 9.7 11.1 7.1 8.0 6.8 Egregia menziesii 0.6 1.0 1.9 3.3 9.2 11.8 7.4 10.2 4.8 Cryptopleura violacea 1.0 1.1 1.7 2.2 7.4 10.5 6.5 5.2 4.1 Mazzaella flaccida 0.9 1.4 4.9 3.8 5.7 3.7 2.3 1.5 3.4 juv. articulated coralline algae 3.3 3.3 2.2 2.6 6.5 8.3 1.3 1.5 3.3 Calliarthron/Bossiella spp.-complex 2.2 4.3 2.2 2.4 3.1 5.2 3.3 5.1 2.7 non-coralline crust 1.5 1.9 1.7 1.7 3.8 5.6 1.7 1.4 2.2 Gastroclonium subarticulatum 2.0 3.5 1.1 1.5 2.2 3.7 0.9 1.5 1.6 Corallinachilensis


4.5 9.1 <0.1 <0.1 1.1 Gelidium pusillum <0.1 ---2.9 4.0 0.2 0.3 0.8 Chondracanthus canaliculatus

<0.1 0.2 0.6 1.3 0.8 1.5 0.6 1.3 0.5 Mastocarpuspapillatus

<0.1 <0.1 <0.1 <0.1 <0.1 0.2 1.9 3.4 0.5 Callithamnion sppJPleonosporium spp. --1.2 1.3 0.6 1.0 <0.1 <0.1 0.5 Chrysophyta 0.9 2.1 <0.1 <0.1 --0.2 Mastocarpusjardinii

<0.1 0.2 0.1 0.4 0.3 0.9 0.1 Chondracanthus corymbiferus

<0.1 <0.1 <0.1 0.2 0.1 0.4 0.1 0.3 <0.1 Gelidium robustum ----0.1 0.4 0.1 0.3 <0.1 Osmundeaspp.

<0.1 <0.1 <0.1 <0.1 0.,2 0.5 <0.1 <0.1 <0.1 Microcladia borealis --0.2 0.7 <0.1 <0.1 -<0.1 Endocladia muricata 0.2 0.7 --<0.1 Laminariales

--0.1 0.4 -<0.1 Laminaria setchellii

<0.1 <0.1 <0.1 <0.1 <0.1 0.2 <0.1 Microcladia coulteri --<0.1 0.2 --<0.1 Grateloupia califomica

--<0.1 0.2 <0.1 Chlorophyta (filamentous)

<0.1 0.2 --<0.1 Codium fragile subsp. Californicum

<0.1 <0.1 --<0.1 0.2 <0.1 filamentous red algae complex <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Ulvaspp. <0.1 <0.1 <0.1 <0.1 --<0.1 Callithamnion pikeanum <0.1 <0.1 --<0.1 Cladophora spp. <0.1 <0.1 --<0.1 Farlowia/Pikeaspp.-complex

--<0.1 <0.1 <0.1 <0.1 <0.1 Codium setchellii

--<0.1 <0.1 --<0.1 Mazzaella oregona <0.1 <0.1 --<0.1 Porphyra spp. <0.1 <0.1 --<0.1 Halymenia/Schizymenia spp.-complex

--<0.1 <0.1 <0.1 Bryopsis spp. -<0.1 <0.1 --<0.1 Invertebrate Counts Anthopleura elegantissima 229.8 177.7 457.6 378.7 408.4 390.7 379.4 302.5 368.8 Strongylocentrotuspurpuratus 118.4 53.5 138.2 79.4 129.6 69.0 129.2 76.6 128.9 Mytilus spp. 93.0 208.0 87.2 194.4 61.4 137.3 25.4 56.8 66.8 Tetraclita rubescens 35.0 65.5 52.6 99.6 36.0 69.6 53.0 106.3 44.2 (table continued) mt ESL02014-02 C-50 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C24 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for South Diablo Point Station SDP 2+0.9m (14+3).Survey 172 173 174 175 Survey Date 14-Jan-13 25-Apr-13 24-Jul-13 18-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Pisaster ochraceus 4.4 1.7 2.0 0.7 2.6 0.5 3.6 1.5 3.2 Fissurella volcano 4.0 3.8 1.8 1.8 2.2 3.5 2.4 1.3 2.6 Lottia pelta 2.2 4.4 5.6 4.3 --1.0 2.2 2.2 Pollicipes polymerus 0.6 1.3 3.6 5.7 2.2 4.9 1.0 2.2 1.9 Pachygrapsus crassipes 0.8 0.8 3.2 1.9 1.6 1.3 1.6 0.5 1.8 Nemertea 0.8 1.3 2.8 1.3 0.6 0.9 1.4 2.1 1.4 Chlorostoma brunnea 2.2 1.6 0.6 0.9 1.2 1.3 --1.0 Serpulidae 0.8 1.8 1.4 1.9 <0.1 <0.1 1.6 2.1 1.0 Anthopleura xanthogrammica 0.8 0.8 1.6 1.8 --1.4 2.2 1.0 Nuttallina califomica 0.8 1.3 1.4 2.2 --1.6 3.0 1.0 Leptasterias spp. 0.6 1.3 1.2 1.3 0.8 0.8 0.8 0.8 0.9 Lottia scabra 0.2 0.4 1.6 3.6 0.8 1.8 --0.7 Balanus spp. --0.4 0.9 1.4 2.2 0.4 0.9 0.6 Tonicella lineata 0.6 0.9 0.4 0.5 0.6 1.3 0.4 0.5 0.5 Mopalia spp. --0.6 0.9 0.2 0.4 1.0 1.2 0.5 Lottia ochracea --<0.1 <0.1 1.6 2.2 <0.1 <0.1 0.4 Nucella spp. 0.6 1.3 1.0 i.7 ---0.4 Pelecypoda borng <0.1 -<0.1 <0.1 1.2 2.7 *<0.1 -0.3 Lottiidae

<0.1 <0.1 -<0.1 -0.8 1.8 0.2 Serpulorbis squamigerus

-0.4 0.5 0.4 0.9 --0.2 Ophiothrix spiculata 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 Pugettia spp. --0.2 0.4 0.4 0.9 <0.1 <0.1 0.2 Lottia gigantea 0.4 0.9 0.2 0.4 ----0.2 Haliotis spp. 0.1 0.3 0.2 0.4 0.1 0.3 0.1 0.3 0.1 Cyanoplaxspp.


0.4 0.9 <0.1 <0.1 0.1 Lottia scutum --0.4 0.9 --0.1 Chlorostoma funebralis 0.2 0.4 0.2 0.4 --0.1 Pagurus spp. ----0.4 0.5 0.1 Lepidozona spp. --0.4 0.9 0.1 Nereididae 0.2 0.4 <0.1 <0.1 --<0.1 Pisaster/Henricia spp. (juv.) ----0.2 0.4 <0.1 Epiactis prolifera 0.2 0.4 <0.1 Pododesmus cepio 0.2 0.4 --<0.1 Romaleon antennarius 0.2 0.4 --<0.1 Alia spp. <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Sipuncula

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Grapsidae

--<0.1 <0.1 <0.1 <0.1 --<0.1 Pycnogonida


<0.1 <0.1 <0.1 Ischnochitonidae

<0.1 <0.1 <0.1 <0.1 --<0.1 Amphissa spp. ----<0.1 <0.1 <0.1 Acmaea mitra <0.1 <0.1 <0.1 Lottia instabilis

<0.1 <0.1 <0.1 Strongylocentrotus franciscanus

<0.1 <0.1 --<0.1 (table continued)

NOW ESL02014-02 C-51 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C24 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for South Diablo Point Station SDP 2+0.9m (14+3).Survey 172 173 174 175 Survey Date 14-Jan-13 25-Apr-13 24-Jul-13 18-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Idotea spp. <0.1 <0.1 --<0.1 Lirobittiumspp.

--<0.1 <0.1 <0.1 Majidae <0.1 <0.1 --<0.1 Aeolidia papillosa

--<0.1 <0.1 <0.1 Lissothuria nutfiens <- -0.1 <0.1 <0.1 Pachycheles spp. <0.1 <0.1 --<0.1 Cirratulidae[Terebellidae

<0.1 <0.1 <0.1 Homolo. luridum/Lirularia succincta

<0.1 <0.1 <0.1 Invertebrate Cover Dodecaceria fewkesi 0.3 0.9 1.0 2.3 0.3 0.9 0.2 0.3 0.4 Porifera (encrusting)

<0.1 <0.1 0.3 0.9 <0.1 <0.1 0.1 0.4 0.1 Phragmatopoma califomica

<0.1 <0.1 0.1 0.4 <0.1 <0.1 <0.1 0.2 <0.1 Salmacina tfibranchiata

<0.1 -<0.1 <0.1 I 0. <0.1 <0.1 <0.1 <0.1 Spirorbidae

<0.1 -<0.1 <0.1 <0.<1 0.11 <0.1 <0.1 <0.1 Chthamalus fissus <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 tunicates, compound/social


<0.1 <0.1 <0.1 <0.1 <0.1 bryozoa (encrusting)

<0.1 <0.1 -<0.1 <0.1 <0.1 Haliclonaspp.

<0.1 <0.1 <0.1 <0.1 <0.1 Spheciospongia confoederata

<0.1 <0.1 <0.1 <0.1 <0.1 Pista spp. --<0.1 <0.1 <0.1 Substrate Cover rock 2.2 3.9 L 2.8 3.7 1 0.6 1.4 7.8 13.9 3.3 fO--ESLO2014-02 C-52 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C25. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for South Control Station SC l+0.3m (19+1).Survey 172 173 174 175 Survey Date 7-Feb-13 6-Jun-13 22-Aug-13 19-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Cover Mazzaellaflaccida 22.8 11.0 39.7 17.0 34.2 17.6 24.7 13.7 30.4 Chondracanthus canaliculatus 19.8 6.1 30.9 11.5 34.4 14.6 18.3 7.5 25.9 non-coralline crust 20.2 5.3 9.7 5.0 11.3 9.5 26.0 9.5 16.8 Gastrocloniumsubarticulatum 14.4 10.3 8.6 9.2 11.2 10.2 18.7 9.2 13.2 Phyllospadixspp.

5.5 8.5 13.7 21.8 14.7 26.0 17.2 28.9 12.8 coralline crust 7.7 3.5 6.9 3.4 10.6 7.8 9.1 4.8 8.6 Cryptopleura violacea 3.5 2.8 2.8 2.7 5.1 6.9 1.6 1.8 3.3 Prionitis spp. 2.8 2.9 3.8 2.7 2.8 3.6 3.3 3.6 3.2 Mastocarpus jardinii 2.5 3.1 3.1 3.3 3.8 4.4 2.2 2.7 2.9 Ulva spp. 2.6 2.5 0.8 1.3 1.8 2.6 1.9 1.8 1.8 Mastocarpus papillatus 1.2 2.4 2.2 1.4 0.8 1.1 0.6 1.0 1.2 Mazzaella oregona 0.8 1.3 1.7 1.5 1.5 2.1 0.3 0.8 1.1 Smithora naiadum --0.3 1.1 2.3 4.2 1.3 3.1 1.0 Corallina vancouveriensis 1.7 2.2 1.2 2.2 0.1 0.4 0.6 1.0 0.9 Endocladia muncata 0.5 1.1 0.8 1.9 0.4 0.9 0.5 0.9 0.6 Porphyraspp.


1.9 5.9 <0.1 <0.1 0.5 Mazzaella splendens 0.3 0.9 1.3 1.7 0.2 0.7 --0.5 Gelidium coulteri 0.1 0.4 <0.1 <0.1 0.3 0.7 0.9 1.8 0.3 Osmundea spp. 0.3 0.6 <0.1 <0.1 <0.1 <0.1 0.6 0.9 0.2 Calliarthron/Bossiella spp.-complex 0.4 1.1 <0.1 <0.1 0.3 1.1 <0.1 0.2 0.2 Chondracanthus corymbiferus

--0.3 0.5 <0.1 0.2 0.3 0.8 0.2 juv. articulated coralline algae 0.3 0.9 <0.1 -<0.1 <0.1 0.2 0.5 0.1 Microcladiacoulteri


0.5 1.1 <0.1 0.2 0.1 Callithamnionpikeanum

<0.1 <0.1 0.5 0.7 <0.1 <0.1 <0.1 <0.1 0.1 Halymenia/Schizymenia spp.-complex 0.1 0.3 0.3 1.1 ----0.1 Gelidium pusillurn

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 0.4 0.9 0.1 Mazzaella affinis --0.2 0.5 <0.1 0.2 <0.1 <0.1 <0.1 filamentous red algae complex --0.2 0.7 <0.1 <0.1 <0.1 Egregia menziesii 0.1 0.4 <0.1 <0.1 <0.1 Cryptopleura ruprechtiana

<0.1 <0.1 <0.1 0.2 <0.1 Silvetia compressa

<0.1 0.2 -----<0.1 Halosaccion ameficanum

<0.1 <0.1 <0.1 <0.1 --<0.1 <0.1 <0.1 Cladophora spp. <0.1 <0.1 -<0.1 <0.1 --<0.1 Sarcodiotheca gaudichaudii

<0.1 <0.1 <0.1 <0.1 --<0.1 <0.1 <0.1 Melobesia mediocris

--<0.1 <0.1 <0.1 <0.1 --<0.1 Laminaria setchellii

<0.1 <0.1 ---<0.1 Pterosiphonia dendroidea

<0.1 <0.1 ----<0.1 Invertebrate Counts Tetraclita rubescens 188.6 155.7 20.4 21.1 140.8 170.1 109.0 124.6 114.7 Pagurus spp. 5.4 6.1 13.4 11.1 10.0 8.9 11.8 6.2 10.2 Ch/orostoma brunnea 0.8 0.4 19.6 14.8 0.4 0.5 3.8 4.7 6.2 Ba/anus spp. --10.4 10.6 ----2.6 (table continued)ESLO2014-02 C-53 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C25 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for South Control Station SC l+0.3m (19+1).Survey 172 173 174 175 Survey Date 7-Feb-13 6-Jun-13 22-Aug-13 19-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Lottia pelta --4.8 4.7 1.4 2.2 0.4 0.9 1.7 Chlorostoma funebralis 0.2 0.4 0.2 0.4 3.2 6.1 0.4 0.5 1.0 Fissurella volcano 0.2 0.4 0.8 1.1 0.4 0.5 1.6 1.8 0.8 Lottia limatula --0.2 0.4 0.8 1.8 1.8 1.9 0.7 Leptasterias spp. 0.2 0.4 0.4 0.5 0.8 1.3 1.2 0.8 0.7 Lottia scutum --1.0 1.4 0.4 0.9 1.2 1.8 0.7 Anthopleura elegantissima 0.8 0.4 0.4 0.5 0.2 0.4 1.0 1.4 0.6 Lottia scabra 0.2 0.4 0.2 0.4 --2.0 3.9 0.6 Nemertea 0.2 0.4 0.8 0.4 0.2 0.4 0.8 0.8 0.5 Epiactis prolifera

--0.8 0.8 0.4 0.9 --0.3 Ocinebrina spp. 0.6 0.9 0.2 0.4 --0.2 0.4 0.3 Serpulidae

--0.2 0.4 0.2 0.4 0.4 0.5 0.2 Mopalia spp. 0.4 0.5 0.4 0.9 --0.2 Pugettia spp. 0.2 0.4 0.2 0.4 0.2 0.4 0.2 Pycnopodia helianthoides

--0.6 0.9 --0.2 Pachygrapsus crassipes 0.2 0.4 0.2 0.4 0.1 Calliostoma ligaturm 0.2 0.4 --<0.1 Serpulorbis squamigerus 0.2 0.4 <0.1 Romaleon antennarius 0.2 0.4 <0.1 Patiria miniata --0.2 0.4 <0.1 Pisaster ochraceus 0.2 0.4 <0.1 Idotea spp. 0.2 0.4 <0.1 Pseudomelatoma torosa 0.2 0.4 <0.1 Lottiidae

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Lacuna spp. <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Ischnochitonidae

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Crepidulaspp.

--<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Grapsidae

<0.1 <0.1 --<0.1 <0.1 <0.1 Alia spp. -<0.1 <0.1 <0.1 <0.1 <0.1 Homolo. luridum/Lirularia succincta

<0.1 <0.1 --<0.1 <0.1 <0.1 <0.1 <0.1 Onchidella borealis -<0.1 <0.1 -<0.1 <0.1 <0.1 Acmaea mitra ---<0.1 <0.1 <0.1 Cyanoplaxspp.

<0.1 <0.1 --<0.1 Tonicella lineata -<0.1 <0.1 <0.1 Lottia insessa <0.1 <0.1 --<0.1 Lottia ochracea -<0.1 <0.1 <0.1 Hermissenda crassicomis

<0.1 <0.1 <0.1 Nereididae


<0.1 <0.1 <0.1 Balanophyllia elegans <0.1 <0.1 ----<0.1 Invertebrate Cover Phragmatopomna califomica 8.5 6.2 3.2 3.7 14.4 8.4 9.3 9.0 8.9 Pistaspp.

<0.1 <0.1 2.6 4.3 --<0.1 <0.1 0.7 tunicates, compound/social

<0.1 <0.1 <0.1 <0.1 0.7 1.2 <0.1 -0.2 (table continued)

I-W ESL02014-02 C-54 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C25 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for South Control Station SC l+0.3m (19+1).Survey 172 173 174 175 Survey Date 7-Feb-13 6-Jun-13 22-Aug-13 19-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Cover (continued)

Chthamalus fissus <0.1 <0.1 0.5 0.9 <0.1 <0.1 <0.1 <0.1 0.1 Porifera (encrusting)

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 0.1 0.3 <0.1 Spirorbidae

<0.1 <0.1 <0.1 -<0.1 <0.1 <0.1 -<0.1 bryozoa (encrusting)

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Substrate Cover rock 5.9 5.4 7.6 5.6 5.6 7.1 5.3 4.0 6.1 cobble 5.7 4.3 2.5 2.7 1.3 1.7 1.2 2.1 2.7 sand (shell gravel) 3.6 5.1 2.6 4.9 1.3 2.1 3.1 7.8 2.7 0MW ESLO2014-02 C-55 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C26. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 M 2) survey means, standard deviations and 2013 annual means for South Control Station SC l+0.9m (19+3).Survey 172 173 174 175 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Cover Silvetia compressa 21.9 12.8 27.0 14.8 27.9 13.0 27.4 13.3 26.1 non-coralline crust 27.6 14.0 17.6 9.6 19.1 9.5 28.7 16.2 23.2 Mastocarpus papillatus 9.6 5.5 23.7 6.3 28.5 13.6 21.5 8.0 20.8 Endocladia muricata 15.6 9.0 15.6 7.0 6.9 4.4 7.5 5.9 11.4 Mazzaella flaccida 5.0 4.9 12.3 6.9 9.9 7.8 9.6 7.4 9.2 coralline crust 9.9 5.3 6.0 3.6 8.6 5.6 8.4 4.7 8.2 Mastocarpus jardinil 2.3 3.9 1.8 2.2 10.4 9.8 4.8 4.8 4.8 Fucus gardneri 2.5 3.8 2.9 2.5 5.0 5.3 2.3 2.7 3.2 Gelidium pusillum 3.7 2.6 1.0 1.0 1.1 2.0 3.9 2.9 2.4 Corallina vancouveriensis 1.7 2.0 1.0 1.6 1.7 3.1 1.3 1.7 1.4 Gelidium coulteri 0.1 0.3 1.1 2.8 0.7 2.0 2.6 3.3 1.1 Cryptopleura violacea 1.2 2.3 0.6 1.3 1.0 1.6 1.7 3.7 1.1 Porphyra spp. <0.1 <0.1 0.5 1.1 0.8 2.4 0.5 1.5 0.5 Chondracanthus canaliculatus 0.3 0.5 <0.1 0.2 0.3 0.7 0.6 1.3 0.3 Hesperophycus califomicus 1.1 2.0 ----<0.1 <0.1 0.3 Ulva spp. <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 0.8 1.6 0.2 Mazzaella oregona 0.1 0.3 <0.1 <0.1 0.5 1.0 <0.1 <0.1 0.2 Mazzaella affinis <0.1 <0.1 <0.1 <0.i 0.5 0.9 <0.1 0.2 0.1 Cladophora spp. <0.1 <0.1 <0.1 0.2 0.3 0.9 0.1 0.4 0.1 filamentous red algae complex 0.3 1.1 ------<0.1 juv. articulated coralline algae --<0.1 <0.1 <0.1 0.2 <0.1 <0.1 <0.1 Callithamnion pikeanum <0.1 <0.1 <0.1 <0.1 <0.1 <0,1 <0.1 <0.1 <0.1 Halosaccion americanum

<0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Phyllospadixspp.

e0.1 <0.1 ---<0.1 <0.1 <0.1 Analipusjaponicus

-<0.1 <0.1 <0.1 Mazzaella leptorhynchos

-<0.1 <0.1 --<0.1 Osmundea spp. --<0.1 <0.1 ----<0.1 Invertebrate Counts Tetraclita rubescens 67.2 123.2 9.8 14.1 19.6 37.0 60.2 91.9 39.2 Chlorostoma funebralis 18.4 16.9 34.8 38.2 9.4 7.5 33.4 22.2 24.0 Lottia scabra 10.2 12.7 2.6 3.2 1.8 2.5 9.0 10.2 5.9 Pagurus spp. 3.0 4.1 1.0 1.2 3.0 4.6 12.2 8.1 4.8 Lottia limatula 2.4 1.5 2.8 2.4 3.2 3.3 6.8 3.6 3.8 Lottia scutum 2.2 1.9 4.8 5.3 3.2 2.0 2.8 2.0 3.3 Anthopleura elegantissima 2.2 2.2 1.6 1.5 1.8 2.2 2.0 2.0 1.9 Lottia pelta 1.8 2.7 3.4 3.2 1.8 2.5 0.4 0.5 1.9 Leptasterias spp. --0.8 0.8 0.4 0.5 1.0 1.0 0.6 Pachygrapsus crassipes 0.2 0.4 0.6 0.9 0.6 0.9 0.4 0.5 0.5 Chlorostoma brunnea --0.4 0.5 1.0 1.7 --0.4 Strongylocentrotus purpuratus 0.2 0.4 --0.8 1.8 0.2 0.4 0.3 Balanus spp. -----1.0 2.2 0.3 Hemigrapsus nudus --0.4 0.5 --0.4 0.5 0.2 Pisaster ochraceus 0.2 0.4 0.4 0.5 0.2 0.4 -0.2 (table continued)

I-W ESL02014-02 C-56 Appendix C -Intertidal Algae, Invertebrates and Substrates Table C26 (continued).

Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m 2) survey means, standard deviations and 2013 annual means for South Control Station SC 1+0.9m (19+3).Survey 172 173 174 175 Survey Date 7-Feb-13 6-Jun-13 22-Aug-13 19-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Ocinebrina spp. 0.4 0.5 0.4 0.5 0.2 Nemertea --0.4 0.5 0.1 Lottiidae

<0.1 <0.1 <0.1 -<0.1 -0.2 0.4 <0.1 Cyanoplaxspp.

0.2 0.4 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 Fissurella volcano --0.2 0.4 ----<0.1 Pugettia spp. --0.2 0.4 ----<0.1 Littonnaspp.

<0.1 <0.1 --<0.1 <0.1 <0.1 <0.1 <0.1 Lottia instabilis


<0.1 <0.1 <0.1 Ischnochitonidae

<0.1 <0.1 <0.1 <0.1 <0.1 Lacuna spp. <0.1 <0.1 <0.1 <0.1 <0.1 Grapsidae

<0.1 <0.1 ----<0.1 Epitonium/Opalia spp. --<0.1 <0.1 <0.1 Petrolisthes spp. --<0.1 <0.1 <0.1 Invertebrate Cover Chtharnalus fissus 1.0 2.3 0.8 2.0 1.2 2.5 1.1 2.1 1.0 Phragmatopoma califomica 0.9 1.3 <0.1 -0.6 1.2 0.8 1.0 0.6 Spirorbidae

<0.1 0.2 -<0.1 <0.1 <0.1 <0.1 <0.1 tunicates, compound/social

--<0.1 <0.1 <0.1 <0.1 <0.1 Porifera (encrusting)

-<0.1 <0.1 <0.1 <0.1 <0.1 Stylantheca spp. <0.1 <0.1 ----<0.1 Haliclona spp. --<0.1 <0.1 <0.1 bryozoa (encrusting)

--<0.1 <0.1 <0.1 Substrate Cover rock 16.3 9.3 15.1 7.1 15.5 13.6 14.4 12.7 15.3 cobble 9.6 10.5 7.4 8.4 5.2 5.8 3.3 3.6 6.4 sand (shell gravel) 5.0 4.8 3.6 4.8 3.1 3.5 2.1 2.3 3.4 421.0ESLO2014-02 C-57 Diablo Canyon Power Plant Appendix D Intertidal Fishes Appendix D -Intertidal Fishes Table DI. Intertidal fish survey totals, 2013 annual means, and standard deviations, North Control Station NC IV (N).Survey 132 133 134 135 Survey Date 6-Feb-13 29-May-13 21-Aug-13 3-Dec-13 Annual Std.Taxon Total Total Total Total Mean Dev.Xiphister mucosus 15 14 12 12 13.3 1.5 Pholidae/Stichaeidae 4 3 18 5 7.5 7.1 Xiphister atropurpureus 2 8 11 9 7.5 3.9 Gobiesox maeandricus 10 1 9 3 5.8 4.4 Oligocottus snyderi 1 1 4 -1.5 1.7 Cottidae 1 3 1 1 1.5 1.0 Gibbonsia spp. 4 ---1.0 2.0 Anoplarchus purpurescens

-1 0.3 0.5 Table D2. Intertidal fish survey totals, 2013 annual means, and standard deviations, Field's Cove Station FC IV (C).Survey 132 133 134 135 Survey Date 11-Jan-13 23-May-13 20-Aug-13 5-Dec-13 Annual Std.Taxon Total Total Total Total Mean Dev.Xiphisterrmucosus 16 14 14 8 13.0 3.5 Cebidichthys violaceus 1 11 5 4.3 5.0 Pholidae/Stichaeidae 2 3 -4 2.3 1.7 Xiphister atropurpureus

--7 1 2.0 3.4 Cottidae 3 4 -1.8 2.1 Anoplarchus purpurescens 2 -1 1.0 0.8 Gibbonsia spp. 1 --0.3 0.5 Gobiesox maeandricus

-I -0.3 0.5 Table D3. Intertidal fish survey totals, 2013 annual means, and standard deviations, North Diablo Cove Station NDC IV (L).Survey 132 133 134 135 Survey Date 11-Jan-13 23-May-13 20-Aug-13 2-Dec-13 Annual Std.Taxon Total Total Total Total Mean Dev.Pholidae/Stichaeidae 2 3 1.3 1.5 Xiphister atropurpureus

-4 1 1.3 1.9 Gibbonsia spp. 1 --0.3 0.5 Cebidichthys violaceus

-1 0.3 0.5 Sebastes miniatus (yoy) -0.3 0.5 4CEO2 ME S0040 D-1 Appendix D -Intertidal Fishes Table D4. Intertidal fish survey totals, 2013 annual means, and standard deviations, South Diablo Cove Station SDC 2V (H).Survey 132 133 134 135 Survey Date 8-Feb-13 29-Apr-13 19-Aug-13 6-Dec-13 Annual Std.Taxon Total Total Total Total Mean Dev.Xiphister atropurpureus 9 14 24 11 14.5 6.7 Cebidichthys vio/aceus 6 8 21 12 11.8 6.7 Xiphistermucosus 16 8 13 8 11.3 4.0 Scytalina cerdale 6 3 4 -3.3 2.5 Pholidae/Stichaeidae 1 4 1 2 2.0 1.4 Anoplarchus purpurescens

-1 2 3 1.5 1.3 Gobiesox maeandricus 0.8 1.5 Cottidae 1 1 -0.5 0.6 Apodichthys fuconim -1 0.3 0.5 Table D5. Intertidal fish survey totals, 2013 annual means, and standard deviations, South Control Station SC IV (S).Survey 132 133 134 135 Survey Date 9-Jan-13 24-May-13 25-Jul-13 4-Dec-13 Annual Std.Taxon Total Total Total Total Mean Dev.Xiphister mucosus 8 12 15 11 11.5 2.9 Pholidae/Stichaeidae 14 14 5 10 10.8 4.3 Anoplarchus purpurescens 20 5 -15 10.0 9.1 Cebidichthys violaceus 7 3 7 9 6.5 2.5 Oligocottus snyderi 2 4.0 6.7 Cottidae 3 13 --4.0 6.2 Xiphister atropurpureus 2 1 2 1.3 1.0 Gobiesox maeandricus 2 1 -1 1.0 0.8 Ulvicola sanctaerosae

--2 0.5 1.0 Gibbonsia spp. I -0.3 0.5 Eý SL02014-02D-D-2 Diablo Canyon Power Plant Appendix E Subtidal Algae and Invertebrates (SAQ Method)

Appendix E -Subtidal Algae and Invertebrates Table El. Subtidal algae and invertebrates (SAQ Method) survey means (abundance per 7 M 2), standard deviations and annual means, Field's Cove Station FC 1 -3m (22-10).Survey 160 161 162 163 Survey Date 19-Mar-13 10-May-13 28-Aug-13 1-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Laminaria setchellii 24.5 6.2 26.8 7.0 24.5 8.4 22.0 4.3 24.4 Pterygophoracalifornica 13.5 12.0 11.5 12.0 12.5 9.2 8.3 7.0 11.4 Cystoseira osmundacea 11.0 10.5 11.3 7.0 2.0 2.8 7.0 4.6 7.8 Laminariales 3.0 4.1 5.8 2.6 --0.5 1.0 2.3 Nereocystis luetkeana

--1.8 2.2 2.0 2.7 0.8 1.0 1.1 Macrocystis pyrifera 1.3 1.0 1.0 1.2 1.3 1.9 1.0 0.8 1.1 Invertebrates Chlorostoma brunnea 87.0 36.1 52.5 32.9 4.5 7.1 49.5 23.6 48.4 Patiria miniata 4.5 1.0 4.0 1.8 3.5 1.0 4.5 1.3 4.1 Calliostoma ligatum 5.3 5.1 1.5 3.0 1.5 3.0 4.5 5.2 3.2 Acmaea mitra 3.0 4.2 3.0 2.5 1.5 1.7 4.5 3.9 3.0 Tonicella lineata 4.5 1.7 0.8 1.5 1.5 1.7 1.5 1.7 2.1 Pugettiaspp.

0.8 0.5 2.0 1.8 0.8 1.5 2.5 2.1 1.5 Cryptochiton stelleri 1.8 1.0 1.0 1.4 1.0 0.8 1.5 0.6 1.3 Chlorostoma montereyi 3.0 4.2 ------0.8 Pagurus spp. --3.0 1.2 --0.8 Diopatra omata 0.8 1.5 1.5 1.3 0.6 Hermissenda crassicornis 1.8 1.5 0.3 0.5 0.5 Leptasterias spp. --0.3 0.5 1.0 0.8 0.8 0.5 0.5 Pycnopodia helianthoides 0.5 0.6 0.5 0.6 0.8 0.5 0.3 0.5 0.5 Mitra idae 0.5 0.6 0.5 0.6 0.5 0.6 0.5 0.6 0.5 Pomaulax gibberosa 0.3 0.5 0.5 1.0 0.3 0.5 0.8 1.5 0.4 Anthopleura elegantissima 0.3 0.5 0.5 0.6 0.5 0.6 --0,3 Doriopsilla albopunctata

--0.5 1.0 0.8 1.5 --0.3 Serpulidae


0.8 1.5 0.5 0.6 0.3 Urticina spp. 0.3 0.5 0.5 0.6 --0.3 0.5 0.3 Strongylocentrotus purpuratus

--0.3 0.5 0.3 0.5 0.5 1.0 0.3 Serpulorbis squamigerus 0.5 0.6 ----0.3 0.5 0.2 Tethya califomiana 0.3 0.5 --0.5 0.6 0.2 Henricia leviuscula

--0.3 0.5 0.3 0.5 0.1 Pisaster giganteus

--0.5 0.6 0.1 Mimulus foliatus 0.3 0.5 0.3 0.5 0.1 Anthopleura artemisia

--0.3 0.5 <0.1 Diodora spp. 0.3 0.5 --<0.1 Mopalia spp. 0.3 0.5 --<0.1 Triopha catalinae


0.3 0.5 <0.1 Placiphorella velata --0.3 0.5 --<0.1 Scyra acutifrons 0.3 0.5 --<0.1_Haliotis spp. 0.3 0.5 <0.1-- ESL02014-02 E-1 Appendix E -Subtidal Algae and Invertebrates Table E2. Subtidal algae and invertebrates (SAQ Method) survey means (abundance per 7 m 2), standard deviations and annual means, North Diablo Cove Station NDC 2 -3m (8-10).Survey 160 161 162 163 Survey Date 1-Feb-13 23-Apr-13 16-Jul-13 18-Oct-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrates Strongylocentrotuspurpuratus 995.3 6.9 859.8 141.3 873.5 151.0 999.0 -931.9 Ophiothrix spiculata 22.3 7.9 76.3 19.3 19.0 2.8 153.5 46.5 67.8 Serpulidae 5.0 2.0 15.5 1.9 8.0 4.1 4.8 3.3 8.3 Anthopleura elegantissima 5.3 1.7 7.0 1.4 2.8 1.5 10.3 3.6 6.3 Strongylocentrotus franciscanus 2.5 1.7 2.5 1.3 2.8 0.5 5.3 4.7 3.3 Anthopleura artemisia


5.3 5.0 1.3 Acmaea mitra --1.5 1.7 3.8 3.8 1.3 Epiactis prolifera 2.0 1.8 --1.0 2.0 0.8 Eudistylia polymorpha

--0.5 0.6 2.0 3.4 0.6 Cucumaria spp. --2.0 0.8 --0.5 Serpulorbis squamigerus 1.0 1.2 --0.3 0.5 0.3 0.5 0.4 Patiria miniata --0.3 0.5 1.0 1.2 0.3 0.5 0.4 Placiphorella velata 0., 0.5 0.5 0.6 --0.2 Pelecypoda boring 0.5 1.0 0.3 0.5 0.2 Ophioplocus esmarki 0.8 0.5 ----0.2 Diodora spp. --0.5 0.6 --0.1 Haliotis spp. 0.3 0.5 0.3 0.5 0.1 Pisaster ochraceus 0.3 0.5 --<0.1 4- FESLO2014-02 E-2 Appendix E -Subtidal Algae and Invertebrates Table E3. Subtidal algae and invertebrates (SAQ Method) survey means (abundance per 7 M 2), standard deviations and annual means, North Diablo Cove Station NDC 3 -3m (9-10).Survey 160 161 162 163 Survey Date 1-Feb-13 23-Apr-13 23-Jul-13 18-Oct-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrates Strongylocentrotus purpuratus 999.0 -999.0 -998.8 0.5 999.0 -998.9 Ophiothrixspiculata 16.3 6.9 246.8 145.4 142.5 52.4 487.5 118.2 223.3 Anthopleura elegantissima 4.5 2.4 11.5 5.3 7.8 3.9 8.0 3.8 7.9 Strongylocentrotus franciscanus 5.0 1.8 4.8 3.0 9.8 4.2 7.5 3.3 6.8 Anthopleura spp. ------14.3 9.0 3.6 Serpulidae 4.0 1.8 4.3 3.6 2.5 2.1 2.7 Phragmatopoma califomica


6.3 12.5 1.6 Lottiidae


4.5 1.3 1.1 Pelecypoda boring 0.3 0.5 3.8 2.8 --1.0 Acmaea mitra 0.8 1.5 1.5 1.7 0.8 1.5 0.8 1.5 0.9 Epiactis prolifera

--2.8 2.1 0.5 0.6 --0.8 Serpulorbis squamigenrs 0.5 0.6 ----2.8 1.0 0.8 Eudistylia polymorpha

--1.0 1.4 0.5 1.0 0.5 1.0 0.5 Patiria miniata --0.5 0.6 0.5 0.6 0.3 Anthopleura artemisia

--0.3 0.5 0.3 0.5 --0.1 Placiphorella velata 0.5 0.6 ----0.1 Doris spp. 0.3 0.5 0.3 0.5 -0.1 Diopatra omata --0.3 0.5 -<0.1 Parastichopus spp. --0.3 0.5 -<0.1 Phidiana hiltoni 0.3 0.5 -----<0.1 Pisasterbrevispinus


0.3 0.5 -<0.1 Pisaster giganteus 0.3 0.5 ---<0.1 Cucumaria spp. 0.3 0.5 ---<0.1 Megathura crenulata

--0.3 0.5 -<0.1 40%W EL2040 E-3 Appendix E -Subtidal Algae and Invertebrates Table E4. Subtidal algae and invertebrates (SAQ Method) survey means (abundance per 7 m 2), standard deviations and annual means, North Diablo Cove Station NDC 4 -4m (9-15).Survey 160 161 162 163 Survey Date 12-Mar-13 25-Apr-13 16-Aug-13 24-Oct-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Cystoseira osmundacea Macrocystis pyrifera Laminariales Pterygophora californica Laminaria setchellii Invertebrates Strongylocentrotus purpuratus Anthopleura elegantissima Acmaea mitra Serpulidae Ophiothrix spiculata Epiactis prolifera Tethya californiana Serpulorbis squamigerus Chlorostoma brunnea Pugettia spp.Pelecypoda boring Parastichopus spp.Tonicella lineata Diopatra ornata Doriopsilla albopunctata Phidiana hiltoni Eudistylia polymorpha Strongylocentrotus franciscanus Anthopleura artemisia Urticina spp Patifia miniata Loxorhynchus spp.Cucumaria spp.Haliotis spp.Pagurus spp.Doris spp.Diodora spp.Pisaster giganteus Crassadoma gigantea Scyra acutifrons Fissurella volcano Pycnopodia helianthoides Anthozoa Pododesmus cepio Pomaulax gibberosa Leptasterias spp.Pseudomelatoma torosa Triopha catalinae Placiphorella velata Pisaster brevispinus Meqathura crenulata 15.3 3.3 0.3 0.8 1.0 79.0 12.5 3.8 9.3 4.0 4.0 1.5 0.8 1.8 0.8 0.5 0.3 1.0 0.3 0.3 0.3 1.0 0.8 0.3 0.3 0.5 10.4 1.3 0.5 1.0 2.0 68.3 3.7 3.8 5.6 2.9 4.1 1.7 1.0 2.4 0.5 1.0 0.5 2.0 0.5 0.5 0.5 1.2 1.0 0.5 0.5 0.6 12.0 3.3 2.3 0.5 1.8 124.3 11.8 4.5 1.8 2.0 0.5 1.3 1.8 0.8 0.8 1.0 0.3 0.5 0.3 0.5 0.5 0.3 0.3 0.3 0.3 7.4 1.0 1.7 1.0 3.5 140.1 3.3 3.0 2.1 1.8 1.0 1.5 1.0 1.5 1.5 0.8 0.5 1.0 0.5 0.6 0.6 0.5 0.5 0.5 0.5 9.5 6.5 3.5 0.6 1.3 1.3 1.5 1.0 0.3 05 104.0 115.0 11.5 4.8 5.3 3.8 2.8 1.7 0.3 0.5 1.0 2.0 0.3 0.5 0.8 1.5 0.5 0.6 0.5 0.6 0.8 1.5 0.8 1.0 0.5 1.0 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 5.8 5.2 2.5 1.0 1.3 1.9 1.5 1.3 0.5 0.6 56.3 55.1 13.5 2.4 11.3 4.5 10.8 8.3 7.8 3.8 0.3 0.5 1.3 1.5 2.0 1.8 3.8 5.7 3.8 1.9 1.5 1.3 0.8 1.5 1.0 2.0 0.8 1.0 1.5 1.3 0.8 1.0 1.0 0.8 0.8 0.5 0.5 0.6 1.5 0.6 1.0 -1.0 0.8 0.5 0.6 0.8 0.5 0.8 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 10.6 3.1 1.3 1.1 0.9 90.9 12.3 6.2 5.0 4.1 1.6 1.1 1.0 0.9 0.9 0.8 0.7 0.6 0.6 0.6 0.6 0.6 0.5 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.1 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 MEW-- rESLO2014_02 E-4 Appendix E -Subtidal Algae and Invertebrates Table E5. Subtidal algae and invertebrates (SAQ Method) survey means (abundance per 7 M 2), standard deviations and annual means, South Diablo Cove Station SDC 2 -3m (12-10).Survey 160 161 162 163 Survey Date 31-Jan-13 19-Apr-13 18-Jul-13 17-Oct-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Alga Cystoseira osmundacea 7.8 4.1 7.5 4.4 7.5 4.1 6.3 5.6 7.3 Macrocystis pyrifera 1.5 1.7 3.3 2.9 1.8 1.3 2.8 1.3 2.3 Pterygophora califomica 1.8 1.7 1.3 1.5 0.8 1.0 2.8 3.5 1.6 Laminaria setchellji

--0.8 1.5 --0.3 0.5 0.3 Sargassum muticum 0.5 0.6 ------0.1 Invertebrates Diopatra omata 39.5 47.0 2.5 3.8 7.3 10.9 6.0 12.0 13.8 Ophiothrixspiculata 2.8 3.1 1.3 1.5 11.8 8.3 20.8 16.9 9.1 Anthopleura elegantissima 1.8 1.0 2.5 1.7 2.3 1.3 2.8 1.0 2.3 Patiria miniata 2.0 0.8 1.5 1.9 1.3 1.3 1.5 0.6 1.6 Pagurus spp. 1.0 1.4 1.3 0.5 0.5 0.6 0.3 0.5 0.8 Serpulidae 1.3 1.9 0.5 0.6 0.3 0.5 1.0 2.0 0.8 Doris spp. 2.5 2.4 0.5 1.0 ----0.8 Strongylocentrotus purpuratus 0.8 1.0 1.3 1.3 0.5 0.6 0.3 0.5 0.7 Cucumaria spp. ------2.8 2.5 0.7 Pisasterbrevispinus 1.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.5 Acmaea mitra --0.8 1.5 --0.8 1.5 0.4 Tonicella lineata 0.8 1.5 ----0.8 1.5 0.4 Pycnopodia helianthoides 0.3 0.5 0.3 0.5 0.3 0.5 0.5 0.6 0.3 Mitra idae 0.3 0.5 --1.0 1.2 --0.3 Pelecypoda boring 0.3 0.5 0.5 1.0 0.3 0.5 0.3 0.5 0.3 Anthopleura artemisia 0.3 0.5 -0.3 0.5 0.3 0.5 0.2 Chlorostoma bnrnnea ----0.8 1.5 --0.2 Pugettia spp. 0.3 0.5 0.3 0.5 0.3 0.5 0.2 Eupentacta quinquesemita

--0.8 1.5 --0.2 Pododesmus cepio --0.5 1.0 0.1 Parastichopus spp. 0.3 0.5 --0.3 0.5 --0.1 Ophioplocus esmarki --0.3 0.5 --0.3 0.5 0.1 Aplysia spp. 0.3 0.5 0.3 0.5 ----0.1 Serpulorbis squamigerus


0.3 0.5 <0.1 Romaleon antennarius 0.3 0.5 --<0.1 Pisasterochraceus

--0.3 0.5 <0.1 Pisaster giganteus 0.3 0.5 --<0.1 Eudistylia polymorpha


0.3 0.5 <0.1 Ceratostoma foliatum --0.3 0.5 --<0.1 Crangon spp. 0.3 0.5 --<0.1 Cadlina spp. 0.3 0.5 <0.1 W -ESLO2014-02 E-5 Appendix E -Subtidal Algae and Invertebrates Table E6. Subtidal algae and invertebrates (SAQ Method) survey means (abundance per 7 m 2), standard deviations and annual means, South Diablo Cove Station SDC 3 -4m (10-15).Survey 160 161 162 163 Survey Date 14-Feb-13 22-Apr-13 24-Jul-13 25-Oct-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean .Dev. Mean Dev. Mean Pterygophora californica 3.3 4.6 3.0 3.4 2.8 4.2 3.8 4.4 3.2 Macrocystis pyrifera 2.0 1.4 2.3 1.9 2.5 1.9 1.5 1.3 2.1 Cystoseira osmundacea 2.3 1.7 2.0 2.3 1.0 1.4 2.0 -1.8 Laminaria setchellii 1.8 1.3 0.3 0.5 --0.5 0.6 0.6 Laminariales


0.5 1.0 --0.1 Invertebrates Anthopleura elegantissima 21.8 3.2 29.3 9.9 23.5 7.9 23.5 7.8 24.5 Diopatra omata 26.3 12.5 46.8 52.9 10.0 5.6 9.3 4.2 23.1 Patiria miniata 10.0 2.5 13.8 4.3 9.5 1.7 15.8 5.2 12.3 Strongylocentrotus purpuratus 9.0 7.6 14.8 6.6 1.8 2.2 2.0 2.2 6.9 Acmaea mitra 5.3 4.5 9.0 2.5 --8.3 2.9 5.6 Anthopleura artemisia 1.5 1.0 2.5 1.7 4.0 1.4 3.8 2.8 2.9 Tethya californiana 3.0 -3.0 1.4 1.8 1.0 2.8 1.0 2.6 Mitre idae 2.8 1.5 4.3 2.1 1.3 1.5 1.3 1.0 2.4 Serpulidae 1.5 1.7 3.8 2.2 1.3 1.5 2.3 1.5 2.2 Doriopsilla albopunctata 1.5 1.3 2.0 0.8 4.5 1.7 0.5 1.0 2.1 Ophioplocus esmarki 0.8 1.5 0.5 1.0 0.8 1.0 4.3 3.6 1.6 Tonicella lineata 2.3 2.9 2.3 1.5 --1.5 1.7 1.5 Loxorhynchus spp. 0.3 0.5 0.3 0.5 --3.3 2.1 0.9 Pugettia spp. 1.5 1.3 0.5 0.6 0.5 0.6 1.3 0.5 0.9 Cucumaria spp. --0.3 0.5 3.3 2.8 --0.9 Serpulorbis squamigerus 1.0 1.2 1.5 0.6 --0.8 0.5 0.8 Cryptochiton stelleri 0.3 0.5 1.3 1.0 1.0 0.8 0.8 1.0 0.8 Pisaster giganteus 0.3 0.5 1.3 1.3 0.8 0.5 0.5 1.0 0.7 Pelecypoda borng 0.8 1.0 0.8 1.0 0.5 0.6 0.5 0.6 0.6 Placiphorella velata --0.5 0.6 0.3 0.5 1.5 1.0 0.6 Urticina spp. 0.5 0.6 0.5 0.6 0.5 1.0 0.3 0.5 0.4 Mimulus foliatus 0.3 0.5 --0.3 0.5 1.3 1.0 0.4 Pisasterbrevispinus

--0.3 0.5 1.0 0.8 0.3 0.5 0.4 Pycnopodia helianthoides

--.0.5 0.6 0.8 0.5 0.3 Pododesmus cepio 0.3 0.5 --0.8 1.5 0.3 Pagurus spp. 0.5 0.6 0.5 0.6 --0.3 Phidiana hiltoni 0.5 1.0 0.5 0.6 ----0.3 Ophiothrix spiculata


1.0 0.8 0.3 Scyra acutifrons 0.3 0.5 0.3 0.5 0.5 0.6 0.3 Chlorostoma brunnea --0.8 1.5 --0.2 Octopus spp. 0.3 0.5 0.5 1.0 0.2 Eudistylia polymorpha 0.5 1.0 0.3 0.5 --0.2 Doris spp. 0.3 0.5 0.3 0.5 0.3 0.5 0.2 Sabellidae 0.3 0.5 0.3 0.5 --0.1 Romaleon antennarius


0.5 1.0 0.1 Crassadoma gigantea 0.5 1.0 0.1 Nemertea 0.3 0.5 <0.1 Diaulula sandiegensis 0.3 0.5 --<0.1 Pseudomelatoma torosa --0.3 0.5 <0.1 (table continued)

MM-- ESLO2014-02 E-6 Appendix E -. Subtidal Algae and Invertebrates Table E6 (continued).

Subtidal algae and invertebrates (SAQ Method) survey means (abundance per 7 m), standard deviations and annual means, South Diablo Cove Station SDC 3 -4m (10-15).Survey 160 161 162 163 Survey Date 14-Feb-13 22-Apr-13 24-Jul-13 25-Oct-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrates (continued)

Triopha catalinae 0.3 0.5 <0.1 Cryptolithodes sitchensis 0.3 0.5 <0.1 Haliotis spp. 0.3 0.5 <0.1 Cadlina spp. --0.3 0.5 <0.1 aEL2040 E-7 Appendix E -Subtidal Algae and Invertebrates Table E7. Subtidal algae and invertebrates (SAQ Method) survey means (abundance per 7 m 2), standard deviations and annual means, South Control Station SC I -3m (19-10).Survey 160 161 162 163 Survey Date 14-Mar-13 26-Apr-13 12-Aug-13 30-Oct-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Pterygophora califomica Laminaria setchellii Cystoseira osmundacea Laminariales Macrocystis pyrifera Invertebrates Chlorostoma brunnea Patiria miniata Anthopleura elegantissima Calliostoma ligatum Tonicella lineata Diopatra omata Cryptochiton steller Pugettia spp.Lottia instabilis Chlorostoma montereyi Dofiopsilla albopunctata Anthopleura artemisia Acmaea mitra Pagunus spp.Pomaulax gibberosa Serpulidae Dodis spp.Serpulorbis squamigerus Hermissenda crassicornis Pisaster giganteus Cryptolithodes sitchensis Mimulus foliatus Urticina spp.Hennicia leviuscula Pycnopodia helianthoides Mitra idae Placiphorella velata Strongylocentrotus purpuratus Scvra acutifrons 40.0 26.8 30.3 12.3 105.8 17.5 6.3 6.8 5.3 3.5 1.3 0.3 2.5 1.3 0.8 1.3 0.5 5.9 11.4 4.9 6.1 44.9 6.4 3.3 3.8 6.2 1.3 0.5 0.5 2.4 1.3 1.0 1.0 0.6 52.3 43.0 39.0 3.5 161.3 15.3 5.5 6.8 0.8 3.0 1.0 0.8 0.5 1.0 1.0 0.5 14.9 16.2 18.6 4.7 100.5 4.2 1.3 3.8 1.5 3.2 1.4 0.5 1.4 2.0 1.0 44.5 16.6 33.3 8.5 29.5 5.5 1.5 2.4 0.3 0.5 114.8 69.1 20.3 5.9 4.8 1.7 0.8 1.5 1.5 1.7 2.3 3.3 1.0 0.8 1.8 1.7 0.8 1.5 0.5 0.6 1.5 1.7 0.3 0.5 0.5 0.6 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.5 0.6 0.3 0.5 34.0 16.5 19.3 149.3 19.5 3.3 2.3 3.0 1.3 1.3 1.8 0.8 2.3 1.0 0.8 0.5 0.8 0.3 1.0 0.8 0.8 0.5 0.3 0.5 0.3 0.5 0.3 5.5 4.4 2.8 43.4 7.0 0.5 1.5 2.5 1.3 1.0 1.7 1.0 4.5 1.2 1.5 0.6 1.5 0.5 1.4 1.0 0.5 0.6 0.5 0.6 0.5 1.0 0.5 42.7 29.9 29.5 4.3<0.1 132.8 18.1 4.9 4.1 2.6 2.5 1.1 0.9 0.8 0.8 0.6 0.6 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1<0.1<0.1 45 ME S0040 E-8 Appendix E -Subtidal Algae and Invertebrates Table E8. Subtidal algae and invertebrates (SAQ Method) survey means (abundance per 7 M 2), standard deviations and annual means, South Control Station SC 2 -6m (20-20).Survey 160 161 162 163 Survey Date 13-Mar-13 9-May-13 14-Aug-13 25-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Pterygophora californica Laminaria setchellii Cystoseira osmundacea Laminariales Nereocystis luetkeana Invertebrates Chlorostoma brunnea Patina miniata Acmaea mitra Diopatra omata Anthopleura elegantissima Calliostoma ligatum Serpulorbis squamigerus Pagurus spp.Chlorostoma montereyi Tonicella lineata Pycnopodia helianthoides Pisaster giganteus Doriopsilla albopunctata Cryptochiton stelleni Leptasterias spp.Tethya californiana Lottia instabilis Mitra idae Pisaster ochraceus Cucumaria spp.Pisaster/Henricia spp. Ouv.)Haliotis spp.Doris spp.Eudistylia polymorpha Pugettia spp.Urticina spp.Pomaulax gibberosa Serpulidae Strongylocentrotus purpuratus Loxorhynchus spp.Crassadoma gigantea Scyra acutifrons Anthopleura artemisia Epiactis prolifera Orthasterias koehleri Eupentacta quinquesemita Diodora spp.Pododesmus cepio Hermissenda crassicomis 27.0 24.5 13.3 8.3 16.3 3.8 6.8 2.8 3.0 2.3 0.8 0.8 0.8 0.3 1.8 1.0 0.8 0.5 0.5 0.5 0.3 0.3 11.2 8.2 7.7 12.6 8.9 2.9 7.0 1.5 2.5 2.6 1.5 0.5 1.5 0.5 1.0 0.8 1.0 0.6 1.0 1.0 0.5 0.5 38.8 16.8 4.8 4.3 0.3 31.5 11.3 5.3 0.5 2.8 3.0 1.5 1.5 1.5 1.5 2.0 1.5 1.3 2.3 1.0 3.3 0.8 0.5 0.3 0.3 0.5 0.5 0.5 0.3 0.3 0.3 0.3 0.3 0.3 10.5 8.9 2.2 1.7 0.5 13.3 2.1 2.9 1.0 1.7 2.5 0.6 1.7 1.7 1.0 0.8 1.0 1.0 0.8 2.0 2.6 0.5 0.6 0.5 0.5 1.0 1.0 1.0 0.5 0.5 0.5 0.5 0.5 0.5 35.8 19.2 27.3 12.7 6.0 1.6 0.3 0.5 12.8 10.5 30.3 4.4 3.8 3.8 4.8 4.0 4.3 1.7 0.8 1.5 2.5 1.3 0.3 0.5 1.5 1.7 0.8 1.5 1.3 1.0 1.0 1.2 0.5 1.0 0.3 0.5 0.3 0.5 0.8 1.5 1.0 1.4 0.8 1.5 1.0 0.8 0.5 1.0 0.5 0.6 1.0 1.4 0.5 0.6 1.3 1.0 0.3 0.5 0.3 0.5 0.3 0.5 0.5 1.0 0.3 0.5 0.3 0.5 52.3 22.2 12.8 7.8 4.8 2.1 3.0 1.8 114.8 38.5 28.3 16.0 5.3 2.9 4.0 2.8 5.3 1.5 4.5 1.7 8.0 5.9 2.5 1.7 3.0 2.5 2.3 1.5 1.5 1.3 1.3 0.5 2.5 0.6 1.3 0.5 2.0 0.8 1.3 1.9 0.5 1.0 2.3 1.5 1.5 0.6 1.3 1.0 0.5 0.6 0.3 0.5 0.8 0.5 0.5 0.6 0.5 0.6 0.3 0.5 0.8 1.0 0.5 0.6 0.8 0.5 0.5 0.6 0.3 0.5 0.5 0.6 0.3 0.5 0.3 0.5 38.4 20.3 7.2 1.8 0.1 41.8 21.5 4.5 4.0 3.8 2.8 2.6 1.6 1.5 1.3 113 1.3 1.2 1.1 1.1 1.0 0.9 0.9 0.9 0.6 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1<0.1<0.1<0.1 (table continued) 0WESLO2014-02 E-9 Appendix E -Subtidal Algae and Invertebrates Table E8 (continued).

Subtidal algae and invertebrates (SAQ Method) survey means (abundance per 7 m 2), standard deviations and annual means, South Control Station SC 2 -6m (20-20).Survey 160 161 162 163 Survey Date 13-Mar-13 9-May-13 14-Aug-13 25-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrates (continued)

Romaleon antennarius

--0.3 0.5 <0.1 Henricia leviuscula 0.3 0.5 --<0.1 Ophioplocus esmarki --0.3 0.5 --<0.1 Mimulus foliatus --0.3 0.5 <0.1 Majidae 0.3 0.5 <0.1 0-R-- ESLO2014-02 E-10 Diablo Canyon Power Plant Appendix F Subtidal Algae (SLC Method)

Appendix F -Subtidal Algae Table Fl. Subtidal algae (SLC Method) survey means (percent cover), standard deviations and annual means, Field's Cove Station FC 1 -3m (22-10).Survey 160 161 162 163 Survey Date 19-Mar-13 10-May-13 28-Aug-13 1-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Calliarthron/Bossiella spp.-complex coralline crust Cryptopleura ruprechtiana Chondracanthus corymbiferus Rhodymenia spp.Macrocystis pyrifera Gelidium robustum Cystoseira osmundacea Neoptilota spp.Prionitis australis Laminaria setchellii non-coralline crust Pterygophora californica Prionitis spp.Ahnfeltiopsis linearis Desmarestia ligulata Microcladia coulteri Farlowia/Pikea spp.-complex Nereocystis luetkeana Callophyllis flabellulata Halymenia/Schizymenia spp.-complex Laminariales Callophyllis spp.Ulva spp.Corallina chilensis Ciyptopleura violacea Callithamnion spp./Pleonosporium spp.Rhodophyta (juv. blades)Substrates colonized rock colonized cobble cobble sand (shell aravehl 50.5 11.8 46.5 8.7 6.0 1.6 8.5 3.4 5.0 6.0 5.5 6.8 1.5 3.0 5.0 4.2 2.5 3.0 1.0 2.0 2.0 2.8 2.5 3.0 1.0 2.0<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01 55.5 45.0 10.0 12.5 12.5 1.0 2.0 2.0 2.0 3.0 1.0 1.0 1.0 1.0 0.5<0.1<0.1<0.1<0.1<0.1<0.1 64.5 15.5 2.0 14.2 6.8 6.9 4.1 3.4 1.2 2.3 2.3 1.6 4.8 1.2 1.2 2.0 1.2 1.0<.01<.01<.01<.01<.01 14.1 10.8 4.0 60.5 6.6 52.5 3.4 14.0 6.3 13.0 4.8 2.5 3.0 4.0 4.6 2.5 3.0 1.5 3.0 2.0 1.6 2.0 4.0 3.0 1.2 1.0 1.2 1.0 2.0<0.1 <.01 1.0 1.2 1.0 2.0<0.1<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01 72.5 3.0 9.0 3.5 0.5 1.0 51.5 40.0 14.5 9.0 4.5 2.0 3.5 0.5 2.5 1.5 1.0 2.5 1.0 1.0<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 62.0 15.0 3.0 1.5 8.2 8.5 7.7 2.6 3.0 2.3 3.4 1.0 2.5 1.9 1.2 1.9 1.2 2.0<.01<.01<.01<.01<.01<.01<.01<.01<.01<.01 10.2 7.8 2.6 1.9 54.5 46.0 11.1 10.8 6.1 3.1 2.4 2.3 2.3 1.9 1.8 1.8 1.0 0.5 0.4 0.3<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 66.0 13.5 2.0 0.4 65.0 14.5 2.5 7.4 5.7 1.9 MEW---ESLO2014-02 F-1 Appendix F -Subtidal Algae Table F2. Subtidal algae (SLC Method) survey means (percent cover), standard deviations and annual means, North Diablo Cove Station NDC 2 -3m (8-10).Survey 160 161 162 163 Survey Date 1-Feb-13 23-Apr-13 16-Jul-13 18-Oct-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae coralline crust 56.0 5.9 41.5 5.5 16.0 5.9 47.0 2.6 40.1 non-coralline crust 2.0 1.6 5.5 4.1 6.0 3.7 6.5 4.4 5.0 Calliarthron/Bossiella spp.-complex

<0.1 -<0.1 -<0.1 -<0.1 -<0.1 Chlorophyta (filamentous)


<0.1 <.01 <0.1 Chrysophyta

--<0.1 <.01 ---<0.1 Substrates colonized cobble 37.0 7.8 31.5 8.4 10.5 6.8 29.5 3.8 27.1 rock 13.0 5.0 23.0 5.3 36.5 14.4 16.5 4.4 22.3 colonized rock 21.5 3.4 15.5 8.2 12.0 4.9 24.5 5.3 18.4 cobble 10.0 2.3 12.0 4.3 22.0 8.6 9.5 4.4 13.4 sand (shell gravel) 0.5 1.0 --1.0 1.2 2.0 2.3 0.9 Table F3. Subtidal algae (SLC Method) survey means (percent cover), standard deviations and annual means, North Diablo Cove Station NDC 3 -3m (9-10).Survey 160 161 162 163 Survey Date 1-Feb-13 23-Apr-13 23-Jul-13 18-Oct-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae}coralline crust 51.5 1.0 45.0 5.3 54.5 6.2 50.5 10.0 50.4 non-coralline crust 1.0 1.2 1.5 1.0 <0.1 <.01 1.0 1.2 0.9 Calliarthron/Bossiella spp.-complex

<0.1 -<0.1 -<0.1 -<0.1 -<0.1 Chlorophyta (filamentous)


<0.1 <.01 <0.1 Substrates colonized rock 28.0 6.3 27.0 4.8 27.5 10.6 29.0 6.0 27.9 rock 24.5 1.0 28.0 2.8 22.0 4.0 22.0 7.5 24.1 colonized cobble 24.5 5.5 19.5 6.0 27.0 7.8 22.5 13.4 23.4 cobble 4.5 2.5 6.5 1.9 4.0 1.6 6.0 1.6 5.3 sand (shell gravel) 0.5 1.0 1.0 1.2 1.5 1.9 2.5 5.0 1.4 0NWESLO2014-02 F-2 Appendix F -Subtidal Algae Table F4. Subtidal algae (SLC Method) survey means (percent cover), standard deviations and annual means, North Diablo Cove Station NDC 4 -4m (9-15).Survey 160 161 162 163 Survey Date 12-Mar-13 25-Apr-13 16-Aug-13 24-Oct-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Aloae coralline crust Calliarthron/Bossiella spp.-complex Acrosorium ciliolatum Farlowia/Pikea spp.-complex filamentous red algae complex Prionitis spp.Cryptopleura violacea Ectocarpales Cystoseira osmundacea Chondracanthus corymbiferus Rhodymenia spp.Desmarestia ligulata Macrocystis pyrifera Chlorophyta (filamentous)

Cryptopleura ruprechtiana Ahnfefltiopsis linearis Gelidium robustum non-coralline crust Pterosiphonia dendroidea Pterygophora californica Halymenia/Schizymenia spp.-complex Laminariales Fryeella gardneri Laminaria setche//li Colpomenia spp.Chondracanthus harveyanus/spinosus Nereocystis luetkeana Callophyllis flabellulata Osmundea spp.Callithamnion spp./Pleonosporium spp.Fauchea laciniata Prionitis australis Chrysophyta Ulva spp.Microcladia coulteri Polyneura latissima Nienburgia andersoniana Invertebrates Phragmatopoma calitomica Substrates colonized rock colonized cobble sand (shell gravel)cobble 48.0 7.8 20.5 5.3 19.5 7.6 8.5 2.5 5.0 3.5 3.5 3.0 5.0 4.8 7.5 9.6 4.0 4.9<0.1 <.01 2.5 2.5<0.1 < .01 0.5 1.0<0.1 <.01<0.1 < .01 0.5 1.0<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01 2.5 2.5 58.5 7.0 14.5 5.5 8.0 7.8 1.0 1.2 38.0 28.0 10.0 12.0 17.5 7.5 9.5 14.5 6.5 6.0 5.0 1.0 0.5 1.5<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 9.9 8.2 4.3 2.8 4.4 7.7 6.8 5.3 4.7 4.0 5.0 2.0 1.0 1.9<.01<.01<.01<.01<.01<.01<.01<.01<.01<.01 46.0 1.6 37.5 7.4 9.5 5.7 9.5 4.1 1.0 2.0 6.0 4.3 13.0 5.3 4.0 4.9 6.0 3.3 8.0 4.3 5.0 6.2 5.0 3.5 4.0 5.4 2.5 3.8 1.5 3.0 0.5 1.0<0.1 <.01 0.5 1.0<0.1 <.01<0.1<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01 59.0 11.6 11.0 4.2 12.0 7.8 53.5 4.7 31.0 9.3 10.0 2.3 9.0 2.6 5.0 5.3 11.0 1.2<0.1 <.01 3.5 4.7 5.5 6.4 3.0 2.0<0.1 <.01<0.1 <.01 0.5 1.0 0.5 1.0 1.0 1.2<0.1 <.01 0.5 1.0<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01 5.0 3.5 67.5 4.1 9.0 3.8 3.5 4.7 2.0 1.6 46.4 29.3 12.3 9.8 7.1 7.0 6.9 6.5 5.0 4.9 3.9 1.5 1.3 1.1 0.5 0.4 0.1 0.1 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 1.9 61.4 10.6 9.0 1.0 60.5 11.5 8.0 5.2 12.5 9.7 1.0 2.0 0 ES LO2014-02 F-3 Appendix F -Subtidal Algae Table F5. Subtidal algae (SLC Method) survey means (percent cover), standard deviations and annual means, South Diablo Cove Station SDC 2 -3m (12-10).Survey 160 161 162 163 Survey Date 31-Jan-13 19-Apr-13 18-Jul-13 17-Oct-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Ctyptopleura violacea coralline crust Calliarthron/Bossiella spp.-complex Rhodymenia spp.Farlowia/Pikea spp.-complex Cystoseira osmundacea Prionitis spp.Chondracanthus corymbiferus Acrosorium ciliolatum Ahnfeltiopsis linearis filamentous red algae complex Macrocystis pyrifera Nienburgia andersoniana Gelidium robustum Callophyllis spp.Corallina chilensis Chondracanthus harveyanus/spinosus Sargassum muticum Cryptopleura ruprechtiana Sarcodiotheca gaudichaudii Rhodophyta (juv. blades)Pterygophora califomica non-coralline crust Callophyllis flabellulata Gelidium spp.Colpomenia spp.Laminaria setchellii Cladophora spp.P/va spp.Prion/its australis Laminariales Desmarestia ligulata Substrates colonized rock sand (shell gravel)cobble colonized cobble rock 6.0 33.5 15.0 12.0 5.5 2.0 4.5 7.0 3.5<0.1<0.1 1.0<0.1<0.1<0.1<0.1<0.1 49.5 13.0 10.5 8.5 0.5 1.6 7.7 8.3 3.7 2.5 1.6 3.0 1.2 4.4<.01<.01 2.0<.01<.01<.01<.01<.01 6.0 5.3 4.4 5.3 1.0 52.5 6.4 21.0 7.4 9.5 3.0 14.5 10.0 7.0 2.6 6.0 3.7 1.5 1.9 1.5 1.9 2.5 1.9 2.0 4.0 4.5 2.5 0.5 1.0<0.1 <.01 1.0 1.2 0.5 1.0<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01 47.5 18.5 9.0 21.5 2.0 5.5 1.5 5.0 1.5 2.5 2.0 0.5 1.0 2.0 0.5 0.5 0.5<0.1<0.1<0.1<0.1 65.5 10.0 4.5 1.0 0.5 10.3 5.7 6.8 4.4 1.6 7.2 1.0 2.0 1.9 3.0 2.8 1.0 1.2 2.3 1.0 1.0 1.0<.01<.01<.01<.01 10.0 5.7 3.4 1.2 1.0 24.5 8.5 38.5 4.1 30.5 11.0 10.0 4.9 4.0 2.8 4.0 4.3 9.5 2.5 7.0 2.6 5.0 4.2<0.1 <.01 1.5 1.0 2.5 1.9 0.5 1.0<0.1 <.01<0.1 <.01 0.5 1.0 0.5 1.0<0.1<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01 32.6 27.9 16.0 14.5 4.6 4.4 4.3 3.4 2.8 2.4 2.0 1.0 0.8 0.6 0.5 0.4 0.1 0.1 0.1 0.1 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 58.4 11.8 7.4 4.1 0.3 61.5 11.0 8.5 1.0 1.9 6.0 4.4 1.2 57.0 13.0 6.0 6.0 3.5 6.2 2.8 5.9 4-02 F-4 Appendix F -Subtidal Algae Table F6. Subtidal algae (SLC Method) survey means (percent cover), standard deviations and annual means, South Diablo Cove Station SDC 3 -4m (10-15).Survey 160 161 162 163 Survey Date 14-Feb-13 22-Apr-13 24-Jul-13 25-Oct-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean coralline crust CalliarthronlBossiella spp.-complex Rhodymenia spp.Chondracanthus corymbiferus Macrocystis pyrifera Cryptopleura violacea Farlowia/Pikea spp.-complex Cryptopleura ruprechtiana Cystoseira osmundacea Callophyllis flabellulata Acrosorium ciliolatum filamentous red algae complex Prionitis spp.Ahnfeltiopsis linearis non-coralline crust Gelidium robustum Plocarnium pacificum Pterygophora californica Corallina chilensis Laminaria setchellii Callophyllis spp.Laminariales Ulva spp.Polyneura latissima Rhodoptilum plumosum Neoptilota spp.Osmundea spp.Prionitis auctralis Antithamnion/Pterotham.

spp.-complex Desmarestia ligulata Invertebrates Balanus/Tetraclita spp.Substrates colonized rock sand (shell gravel)colonized cobble cobble rock 46 31 14 3 2 1 2 1<2.1.1.1.<0.5 16.2.0 10.0.0 10.5.0 3.8.0 2.8.0 1.2.0 1.6.5 1.9.0 2.8.0 1.2.5 3.0.5 1.0.1.1 <.01.1 <.01.1 <.01<0<0<0 47.0 41.0 20.5 4.0 3.5 7.0 3.5 1.5 2.0 3.5 2.0 1.0<0.1<0.1<0.1 0.5<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 72.5 6.0 1.5 2.0 4.8 6.2 7.2 1.6 1.0 4.8 2.5 1.9 2.8 3.4 2.0<.01<.01<.01 1.0<.01<.0i<.01<.01<.01<.01<.01<.01<.01<.01< .01 4.4 4.3 1.0 1.6 36.5 10.3 44.0 8.3 17.0 8.9 5.5 3.4 3.5 3.0 2.0 2.3 3.5 4.1 5.5 3.4 1.0 1.2<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01 1.0 1.2<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01 1.5 3.0 48.5 3.8 31.0 5.8 14.5 8.5 5.0 2.6 4.5 3.0 2.0 2.3 2.5 2.5 3.0 2.6<0.1 <.01<0.1 <.01 0.5 1.0<0.1 <.01 0.5 1.0 0.5 1.0<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01 2.0 2.3 44.6 36.8 16.5 4.4 3.4 3.0 2.9 2.9 1.3 0.9 0.8 0.6 0.5 0.3 0.1 0.1 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 0.9 66.3 9.1 3.9 2.6 0.1 62.5 9.0 11.5 10.3 5.5 3.4 2.0 2.8 0.5 1.0 65.5 9.0 6.0 1.5 8.5 6.6 4.3 3.0 64.5 10.0 2.5 5.0 6.2 5.9 1.0 2.0 0%MW ESLO2014-02 F-5 Appendix F -Subtidal Algae Table F7. Subtidal algae (SLC Method) survey means (percent cover), standard deviations and annual means, South Control Station SC I -3m (19-10).Survey 160 161 162 163 Survey Date 14-Mar-13 26-Apr-13 12-Aug-13 30-Oct-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Algae Calliarthron/Bossiella spp.-complex 49.5 10.0 49.5 8.5 46.0 16.6 55.5 8.1 50.1 coralline crust 34.0 4.9 38.5 7.2 36.5 6.6 38.0 1.6 36.8 Cystoseira osmundacea 16.0 7.8 20.0 5.9 13.5 3.4 19.0 4.2 17.1 Rhodymeniaspp.

14.5 3.4 15.5 8.4 13.5 4.4 12.5 5.0 14.0 Pterygophora californica 3.0 3.5 3.0 2.0 4.0 2.8 1.5 1.9 2.9 Laminaria setchellii 2.0 2.8 2.0 1.6 <0.1 -2.5 1.9 1.6 Cryptopleura ruprechtiana 1.5 1.9 2.5 3.0 <0.1 <.01 <0.1 <.01 1.0 Chondracanthus corymbiferus 0.5 1.0 1.0 1.2 <0,1 <.01 2.5 2.5 1.0 Gelidium robustum 0.5 1.0 1.0 2.0 1.5 1.9 0.5 1.0 0.9 Corallina chilensis

<0.1 <.01 0.5 1.0 <0.1 <.01 1.0 2.0 0.4 Rhodophyta (juv. blades) <0.1 <.01 1.5 1.9 <0.1 <.01 --0.4 non-coralline crust --<0.1 <.01 0.5 1.0 1.0 1.2 0.4 Plocamiumpacificum 0.5 1.0 <0.1 <.01 0.5 1.0 <0.1 <.01 0.3 filamentous red algae complex <0.1 <.01 -0.5 1.0 --0.1 Cryptopleura violacea -----0.5 1.0 0.1 Ulva spp. <0.1 <.01 <0.1 <.01 <0.1 <.01 <0.1 <.01 <0.1 Callophyllis spp. <0.1 <.01 <0.1 <.01 --<0.1 <.01 <4.1 Callophyllis flabellulata

<0.1 <.01 <0.1 <.01 <0.1 <.01 <0.1 <.01 <0.1 Microcladia cou/teri -<0.1 <.01 <0.1 <.01 <0.1 <.01 <0.1 Delesseria decipiens

<0.1 <.01 <0.1 <.01 ----<0.1 Prionitis australis

<0.1 <.01 <0.1 <.01 <0.1 <.01 <0.1 Halicystis ovalis --<0.1 <.01 <0.1 <.01 <0.1 Neoptilota spp. ----<0.1 < 01 <0.1 <.01 <0.1 Pterosiphonia dendroidea

<0.1 <.01 -----<0.1 Laminariales

--<0.1 <.01 <0.1 <.01 <0.1 Ahnfe/tiopsis linearis <0.1 <.01 <0.1 <.01 <0.1 Farlowia/Pikea spp.-complex

-<0.1 <.01 <0.1 <.01 <0.1 Osmundea spp. --<0.1 <.01 <0.1 Macrocystis pyrifera <0.1 <.01 --<0.1 Desmarestia ligulata <0.1 <.01 <0.1 Mazzaella splendens

<0.1 <.01 --<0.1 Invertebrates Phragmatopoma califomica 8.0 5.4 6.0 3.3 7.0 5.3 7.0 5.3 7.0 tunicates, compound/social


1.5 1.9 --0.4 Substrates colonized rock 66.5 5.7 66.5 6.0 65.0 4.2 65.5 3.4 65.9 sand (shell gravel) 12.5 5.7 9.5 1.9 7.5 1.0 8.0 5.4 9.4 colonized cobble 2.5 1.9 4.5 3.4 5.0 3.8 7.5 6.0 4.9 cobble 0.5 1.0 1.0 2.0 4.0 4.3 1.5 1.0 1.8 rock 0.5 1.0 0.1 fW- ESL02014-02 F-6 Appendix F -Subtidal Algae Table F8. Subtidal algae (SLC Method) survey means (percent cover), standard deviations and annual means, South Control Station SC 2 -6m (20-20).Survey 160 161 162 163 Survey Date 13-Mar-13 9-May-13 14-Aug-13 25-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Alqae coralline crust Calliarthron/Bossiella spp.-complex Cystoseira osmundacea Pterygophora califomica Rhodymenia spp.Laminaria setchellii filamentous red algae complex Rhodophyta (juv. blades)non-coralline crust Callophyllis spp.Desmarestia ligulata Cryptopleura ruprechtiana Fryeella gardneri Dictyota binghamiae Pterosiphonia dendroidea Amplisiphonia pacifica Callophyllis flabellulata Chondracanthus corymbiferus Rhodoptilum plumosum Neoptilota spp.Fauchea laciniata Weeksia spp.Opuntiella califomica Pugetia firma Laminariales Corallina chilensis Nereocystis luetkeana Delesseria decipiens Membranoptera/Branchioglossum spp.Dictyoneurum califomicum Ahnfeltiopsis linearis Farlowia/Pikea spp.-complex Invertebrates BalanusITetraclita spp.bryozoa (encrusting)

Corynactis califomica Porifera (encrusting) tunicates, compound/social Phragmatopoma califomica bryozoa (erect)Substrates colonized rock colonized cobble sand (shell gravel)cobble 59.0 29.5 3.5 4.0 0.5 1.5<0.1<0.1 1.0 0.5 0.5 1.0<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 2.0 73.5 3.5 3.0 2.0 4.2 24.1 3.4 3.7 1.0 1.9<.01<.01 2.0 1.0 1.0 2.0<.01<.01<.01<.01<.01<.01<.01<.01<.01<.01 4.0 8.7 4.7 3.5 2.3 54.0 6.3 39.0 10.5 5.0 5.3 3.5 4.1 3.0 2.0<0.1 <.01 2.0 2.8 3.0 2.6 0.5 1.0 0.5 1.0 0.5 1.0<0.1 <.01 0.5 1.0 0.5 1.0 1.0 2.0 0.5 1.0<0.1 <.01<0.1<0.1 <.01<0.1<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01 0.5 1.0 1.0 2.0 2.0 2.8 1.5 1.9 2.5 1.9 0.5 1.0 72.5 7.6 7.0 4.2 2.0 2.8 0.5 1.0 47.5 2.5 42.0 13.4 7.0 4.2 1.0 1.2 4.0 1.6 1.0 1.2 1.5 1.9 1.0 2.0 1.0 2.0 1.0 2.0<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01 46.5 4.1 33.5 12.8 7.0 6.2 2.5 1.9 2.5 3.8 2.0 2.3 0.5 1.0 0.5 1.0<0.1 <.01<0.1 <.01<0.1 <.01<0.1 0.5 1.0<0.1 <.01<0.1 <.01<0.1 <.01<0.1 <.01 7.5 6.6 5.0 5.3 1.5 3.0 3.0 2.0 1.0 2.0 2.5 1.9 70.0 7.3 10.5 6.0 1.5 1.9 51.8 36.0 5.6 2.8 2.5 1.1 1.0 0.8 0.5 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.1 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 3.1 2.3 2.0 1.5 1.4 0.6 0.1 71.6 7.5 2.1 0.6 4.5 3.0 2.5 1.5 2.0 3.0 3.5 3.0 1.9 2.8 70.5 7.6 9.0 5.8 2.0 2.3 0 n---E ESLO2014-02 F-7 Diablo Canyon Power Plant Appendix G Subtidal Invertebrates (SFQ Method)

Appendix G -Subtidal Invertebrates Table GI. Subtidal invertebrates (SFQ Method) survey means (abundance per 0.25 M 2; percent cover)standard deviations and annual means, Field's Cove Station FC 1 -3m (22-10).Survey 160 161 162 163 Survey Date 19-Mar-13 10-May-13 28-Aug-13 1-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts Homolo. luridum/Lirulafia succincta 7.8 6.0 5.8 7.0 8.3 4.0 6.0 1.8 6.9 Chlorostoma brunnea 4.5 2.4 6.0 2.7 4.3 2.6 5.8 6.6 5.1 Pagurus spp. 1.0 0.8 2.3 1.3 2.8 1.0 13.5 6.1 4.9 A/ia spp. 3.8 6.2 0.5 1.0 0.8 0.5 1.5 0.6 1.6 Pugettia spp. 1.8 1.0 2.0 1.2 1.0 1.4 1.5 1.0 1.6 Phragmatopoma califomica 0.8 1.0 0.5 0.6 0.3 0.5 4.0 4.3 1.4 Leptasterias spp. 2.3 1.5 0.8 1.0 1.0 0.8 1.3 1.0 1.3 Amphissa spp. 1.0 0.8 1.3 1.0 1.5 1.3 1.5 0.6 1.3 Serpulidae 1.3 1.0 --1.3 1.0 0.5 0.6 0.8 Aptyxis luteopictus 1.8 1.0 0.3 0.5 --0.5 1.0 0.6 Mitra idae 0.5 0.6 ----1.5 0.6 0.5 Mimulus foliatus 1.0 1.4 0.3 0.5 0.5 0.6 0.4 Calliostoma ligaturm 0.5 0.6 0.5 0.6 0.5 0.6 0.4 Pista spp. 1.0 2.0 0.5 1.0 --0.4 Pisaster/Henricia spp. (juv.) 0.3 0.5 0.3 0.5 0.3 0.5 0.8 1.0 0.4 Lophopanopeus spp. ----0.3 0.5 1.3 1.0 0.4 Lissothuria nutriens --0.8 1.0 --0.8 0.5 0.4 Epiactis prolifera 0.5 0.6 0.3 0.5 0.3 0.5 --0.3 Tonicella lineata 0.8 0.5 -0.3 0.5 0.3 Pomaulax gibberosa

--0.5 1.0 0.5 0.6 --0.3 Lottia instabilis 0.3 0.5 --0.5 1.0 0.3 0.5 0.3 Loxorhynchus spp. 0.5 0.6 ----0.5 0.6 0.3 Ocinebrina spp. 0.8 1.0 0.3 0.5 --0.3 Sipuncula 0.5 0.6 --0.5 0.6 0.3 Acmaea mitra 0.3 0.5 0.3 0.5 0.3 0.5 0.2 Fissurella volcano 0.3 0.5 0.3 0.5 0.3 0.5 0.2 Hermissenda crassicomis 0.3 0.5 --0.5 0.6 --0.2 Sabellidae


0.8 1.0 0.2 Petrolisthes spp. ----0.8 1.5 0.2 Pseudomelatoma torosa 0.3 0.5 --0.3 0.5 0.3 0.5 0.2 Lirobittium spp. --0.3 0.5 0.5 1.0 --0.2 Pelecypoda boring 0.8 1.0 -----0.2 Pachycheles spp. ----0.8 1.0 0.2 Anthopleura elegantissima 0.3 0.5 0.3 0.5 --0.1 Chlorostoma montereyi


0.3 0.5 0.3 0.5 0.1 Promartynia pulligo 0.3 0.5 0.3 0.5 ----0.1 lschnochitonidae

--0.3 0.5 0.3 0.5 0.1 Ophiuroidea

--0.5 1.0 0.1 Cryptolithodes sitchensis

--0.5 0.6 --0.1 Majidae --0.3 0.5 --0.3 0.5 0.1 Scyra acutifrons 0.5 1.0 ----0.1 Cancridae


0.5 0.6 0.1 Aeolidia papillosa 0.3 0.5 0.3 0.5 --0.1 (table continued)

W ESLO2014-02 G-1 Appendix G -Subtidal Invertebrates Table GI (continued).

Subtidal invertebrates (SFQ Method) survey means (abundance per 0.25 M 2;percent cover) standard deviations and annual means, Field's Cove Station FC 1 -3m (22-10).Survey 160 161 162 163 Survey Date 19-Mar-13 10-May-13 28-Aug-13 1-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Anthozoa 0.3 0.5 --<0.1 Diodora spp. --0.3 0.5 <0.1 Serpulorbis squamigerus

--0.3 0.5 <0.1 Lottiidae 0.3 0.5 --<0.1 Crepidula spp. --0.3 0.5 <0.1 Lottia ochracea 0.3 0.5 --<0.1 Romaleon antennarius 0.3 0.5 --<0.1 Patiria miniata --0.3 0.5 <0.1 Strongylocentrotus purpuratus 0.3 0.5 --<0.1 Diaulula sandiegensis

--0.3 0.5 <0.1 Cryptochiton stelleri 0.3 0.5 <0.1 Eulithidium spp. 0.3 0.5 <0.1 Paraxanthias taylori 0.3 0.5 --<0.1 Cirratulidae/Terebellidae 0.3 0.5 --<0.1 Cadlina spp. --0.3 0.5 --<0.1 Hapalogaster cavicauda

--0.3 0.5 <0.1 Sipunculidae


0.3 0.5 <0.1 Invertebrate Cover BalanusTetraclita spp. <0.1 0.1 0.5 0.9 1.0 1.9 0.3 0.7 0.5 Porifera (encrusting)

<0.1 0.1 <0.1 0.1 0.1 0.2 0.3 0.4 0.1 tunicates, compound/social

<0.1 -0.1 0.2 <0.1 -0.3 0.3 <0.1 bryozoa (encrusting)

<0.1 0.1 <0.1 -<0.1 0.1 <0.1 0.1 <0.1 Spirorbidae

<0.1 -<0.1 <.01 <0.1 -<0.1 -<0.1 WW ESLO2014-02 G-2 Appendix G -Subtidal Invertebrates Table G2. Subtidal invertebrates (SFQ Method) survey means (abundance per 0.25 1n 2; percent cover)standard deviations and annual means, North Diablo Cove Station NDC 2 -3m (8-10).Survey 160 161 162 163 Survey Date 1-Feb-13 23-Apr-13 16-Jul-13 18-Oct-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts Strongylocentrotuspurpuratus 57.0 12.1 47.8 15.8 44.3 13.1 35.5 23.1 46.1 Pelecypoda boring 16.5 15.4 52.3 31.4 30.8 24.6 27.3 17.7 31.7 Phragmatopoma califomica 8.5 5.2 9.5 3.7 12.3 6.9 6.3 5.1 9.1 Ophiactis simplex 6.8 5.1 9.8 4.7 8.0 10.7 3.0 1.8 6.9 Serpulidae 2.3 0.5 1.0 0.8 5.5 3.1 1.3 1.0 2.5 Sipuncula 1.8 2.1 3.0 0.8 1.8 1.0 1.8 1.5 2.1 CirratulidaelTerebellidae

--0.3 0.5 6.8 6.4 --1.8 Ophiothrix spiculata 1.0 2.0 1.3 1.0 1.8 1.7 2.5 2.7 1.6 Epiactis prolifera 1.0 1.4 1.3 1.5 0.8 0.5 --0.8 Cucumafia spp. 0.3 0.5 2.3 1.3 ----0.6 Lottia ochracea 0.3 0.5 0.8 0.5 0.8 0.5 0.3 0.5 0.5 Anthopleura elegantissima 0.5 0.6 0.5 0.6 0.5 0.6 0.3 0.5 0.4 Fissurella volcano 0.3 0.5 0.8 1.0 0.3 0.5 0.3 0.5 0.4 Acmaea mitra --0.5 0.6 0.3 0.5 0.5 0.6 0.3 Lottiidae

--0.5 0.6 0.5 0.6 0.3 Eudistylia polymorpha 0.8 1.5 0.3 0.5 --0.3 Anthopleura artemisia 0.3 0.5 --0.3 0.5 0.1 Diodora spp. 0.3 0.5 0.3 0.5 ----0.1 Polychaeta


0.5 1.0 --0.1 Strongylocentrotus franciscanus

--0.3 0.5 --0.3 0.5 0.1 Lirobittium spp. 0.5 1.0 -----0.1 Amphissa spp, 0.3 0.5 -0.3 0.5 --0.1 Lissothuria nutriens 0.3 0.5 ---0.3 0.5 0.1 Alia spp. 0.3 0.5 ----<0.1 Serpulorbis squamigerus

--0.3 0.5 <0.1 Ocinebrina spp. 0.3 0.5 --<0.1 Ischnochitonidae

-0.3 0.5 <0.1 Placiphorella velata 0.3 0.5 --<0.1 Mimulus foliatus --0.3 0.5 <0.1 Eulithidium spp. --0.3 0.5 --<0.1 Megathura crenulata 0.3 0.5 ----<0.1 Invertebrate Cover Balanus/Tetraclita spp. --<0.1 0.1 0.1 0.3 0.1 0.2 <0.1 Porifera (encrusting)

--<0.1 <.01 --<0.1 <.01 <0.1 bryozoa (encrusting)

<0.1 <.01 --<0.1 <.01 --<0.1 Spirorbidae

--<0.1 <.01 --<0.1 4' ESLO22014-02 G-3 Appendix G -Subtidal Invertebrates Table G3. Subtidal invertebrates (SFQ Method) survey means (abundance per 0.25 mr; percent cover)standard deviations and annual means, North Diablo Cove Station NDC 3 -3m (9-10).Survey 160 161 162 163 Survey Date 1-Feb-13 23-Apr-13 23-Jul-13 18-Oct-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts Pelecypoda boring -22.5 14.6 69.5 20.5 35.8 34.3 43.8 22.2 42.9 Strongylocentrotus purpuratus 44.8 24.7 39.0 27.2 37.8 19.9 41.0 26.2 40.6 Ophiactis simplex 6.0 8.2 22.0 15.3 16.5 8.7 12.5 6.2 14.3 Phragmatoporna californica 8.8 10.9 9.3 8.4 13.0 16.5 9.3 7.3 10.1 Ophiothrix spiculata 3.8 4.5 4.3 3.8 2.3 2.6 9.8 8.8 5.0 Sipuncula 1.0 0.8 3.5 1.0 7.3 3.9 2.3 1.3 3.5 Cucumaria spp. --3.8 1.3 1.8 2.2 1.3 0.5 1.7 Lottia ochracea 0.8 0.5 1.0 0.8 2.0 1.4 2.0 2.2 1.4 Serpulidae 1.3 2.5 0.8 0.5 1.3 1.3 1.3 1.0 1.1 Acmaea mitra 0.5 0.6 0.3 0.5 0.5 0.6 1.0 0.8 0.6 Lottiidae 0.5 1.0 0.3 0.5 0.3 0.5 1.3 1.3 0.6 Anthopleura elegantissima 0.5 1.0 0.3 0.5 0.5 1.0 0.5 1.0 0.4 Epiactis prolifera 0.3 0.5 0.5 0.6 0.3 0.5 0.8 0.5 0.4 Strongylocentrotus franciscanus 0.8 0.5 0.3 0.5 0.8 1.0 --0.4 Fissurella volcano 0.3 0.5 0.5 0.6 0.3 0.5 0.5 0.6 0.4 Eudistylia polymorpha 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 Sabellidae


0.3 0.5 0.5 0.6 0.2 Anthozoa 0.3 0.5 0.3 0.5 0.1 Polychaeta 0.5 0.6 --0.1 Lissothuria nutriens 0.3 0.5 --0.3 0.5 0.1 Patiria miniata --0.3 0.5 --<0.1 Ischnochitonidae

--0.3 0.5 <0.1 Placiphorella velata --0.3 0.5 <0.1 Crangon spp. 0.3 0.5 --<0.1 Invertebrate Cover BalanusTetraclita spp. 0.1 0.3 --<0.1 Spirorbidae

<0.1 <.01 <0.1 <.01 <0.1 <.01 <0.1ý"w S0040 G-4 Appendix G -Subtidal Invertebrates Table G4. Subtidal invertebrates (SFQ Method) survey means (abundance per 0.25 m'2; percent cover)standard deviations and annual means, North Diablo Cove Station NDC 4 -4m (9-15).Survey 160 161 162 163 Survey Date 12-Mar-13 25-Apt-13 16-Aug-13 24-Oct-1 3 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts Phragmatopoma califomnica 73.0 92.3 37.0 40.4 47.0 47.2 48.5 42.7 51.4 Strongylocentrotus purpuratus 11.8 16.3 13.8 13.7 8.5 13.0 9.5 15.7 10.9 Pelecypodla boring 13.5 26.3 3.8 7.5 -1.3 2.5 4.6 Idotea spp. -17.5 21.8 -4.4 Ophiothrix spiculata 1.5 1.7 1.0 0.8 3.5 2.1 2.8 2.2 2.2 Ophiactis simplex 1.8 2.4 4.8 8.9 -1.3 1.5 1.9 Serpulidae 2.3 0.5 2.0 1.8 1.3 0.5 1.3 1.3 1.7 Sipuncula 0.8 1.5 1.5 3.0 2.0 2.3 0.8 1.0 1.3 Epiactis prolifera 1.0 1.2 2.5 1.3 -0.8 0.5 1.1 Acmaea mitra 0.8 1.0 0.8 1.0 1.0 0.8 1.5 1.3 1.0 Anthopleura elegantissima 0.8 1.5 1.3 1.9 0.5 1.0 1.3 1.9 0.9 Pugettia spp. 0.5 0.6 0.3 0.5 1.3 1.0 0.8 1.0 0.7 Amphissa spp. 1.3 1.5 0.5 1.0 -0.8 1.0 0.6 Afia spp. 1.0 0.8 1.0 1.2 0.3 0.5 -0.6 Fissurella volcano 1.0 0.8 -0.5 1.0 0.5 0.6 0.5 Serpulorbis squamigerus 0.5 0.6 0.3 0.5 0.5 0.6 0.3 0.5 0.4 Lottiidae

-0.5 0.6 0.5 0.6 0.3 0.5 0.3 Doriopsilla albopunctata 0.3 0.5 0.5 1.0 0.3 0.5 0.3 0.5 0.3 Chlorostomna brunnea -0.5 0.6 -0.5 1.0 0.3 Pista spp. 0.8 0.5 0.3 0.5 -0.3 Dendropoma spp. -1.0 2.0 -0.3 Pagurus spp. 0.3 0.5 0.3 0.5 0.3 0.5 0.2 Cucumanafi spp. 0.3 0.5 -0.5 0.6 -0.2 Scyra acutifrons 0.3 0.5 0.3 0.5 -0.3 0.5 0.2 Lissothuria nutriens 0.3 0.5 0.3 0.5 0.3 0.5 0.2 Tonicella lineata 0.3 0.5 0.3 0.5 -0.1 Lottia ochracea -0.5 0.6 -0.1 Sabellidae

-0.5 0.6 0.1 Loxorhynchus spp. -0.5 1.0 0.1 Ocinebrina spp. 0.3 0.5 -0.3 0.5 -0.1 Mimulus foliatus -0.3 0.5 0.3 0.5 0.1 Cancridae 0.3 0.5 0.3 0.5 -0.1 Heptacarpus spp. -0.5 0.6 0.1 Eulithidium spp. 0.5 1.0 -0.1 Megathura crenulata

-0.3 0.5 0.3 0.5 0.1 Anthopleura artemisia

-0.3 0.5 -<0.1 Diodora spp. -0.3 0.5 <0.1 Hermissenda crassicomnis

-0.3 0.5 -<0.1 Romaleon antennarius 0.3 0.5 -<0.1 Leptasterias spp. -0.3 0.5 -<0. I Cancer productus

-0.3 0.5 <0.1 Leucilla nuttingi -0.3 0.5 <0.1 Ischnochitonidae 0.3 0.5 -<0.1 (table continued)LO2014-02 G-5 Appendix G -Subtidal Invertebrates Table G4 (continued).

Subtidal invertebrates (SFQ Method) survey means (abundance per 0.25 M 2;percent cover) standard deviations and annual means, North Diablo Cove Station NDC 4 -4m (9-15).Survey 160 161 162 163 Survey Date 12-Mar-13 25-Apr-13 16-Aug-13 24-Oct-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Lirobittium spp. 0.3 0.5 <0.1 Cryptolithodes sitchensis 0.3 0.5 <0.1 Majidae 0.3 0.5 <0.1 Chama spp. 0.3 0.5 --<0.1 Lepidozona spp. --0.3 0.5 <0.1 Cirratulidae/"erebellid ae 0.3 0.5 --<0.1 Homolo. luridurn/Lirularia succincta

--0.3 0.5 <0.1 Invertebrate Cover Balanus/Tetraclita spp. <0.1 <.01 0.3 0.4 1.0 1.9 1.4 1.2 0.6 Porifera (encrusting)

<0.1 -<0.1 -0.7 0.9 <0.1 -0.2 tunicates, compound/social

<0.1 <.01 <0.1 <.01 <0.1 <.01 <0.1 -<0.1 bryozoa (encrusting)

<0.1 <.01 <0.1 <.01 --<0.1 <.01 <0.1 Spirorbidae

<0.1 <.01 <0.1 <.01 --<0.1 -<0.1 Salmacina tribranchiata

<0.1 <.01 -<0.1 <.01 <0.1 <.01 <0.1 aEI00140 G-6 Appendix G -Subtidal Invertebrates Table G5. Subtidal invertebrates (SFQ Method) survey means (abundance per 0.25 M 2; percent cover)standard deviations and annual means, South Diablo Cove Station SDC 2 -3m (12-10).Survey 160 161 162 163 Survey Date 31-Jan-13 19-Apr-13 18-Jul-13 17-Oct-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts Pista spp.Alia spp.Ophiothrix spiculata Phragmatopoma califomica Pelecypoda borng Chaetopteridae Serpulidae Ophiactis simplex Ophiuroidea Amphissa spp.Pagurus spp.Sipuncula lschnochitonidae Pugettia spp..Fissurehla volcano Acmaea mitra Strongylocentrotus purpuratus Scyra acutifrons Patiria miriata Cucumaria spp.Lottiidae Diopatra omata Balanophyllia elegans Doriopsilla albopunctata Anthozoa Serpulorbis squamigerus Tonicella iineata Hermissenda crassicomis Mitra idae Lirobittium spp.Crassadoma gigantea Eulithidium spp, 24.5 14.9 18.3 16.6 1.3 0.5 4.8 5.0 0.8 1.5 1.5 0.6 4.3 3.9 1.5 2.4 0.3 0.5 0.3 0.5 1.5 2.4 0.3 0.5 0.5 0.6 0.5 0.6 0.5 0.6 0.5 1.0 0.5 1.0 0.5 1.0 0.5 0.6 0.5 1.0 0.3

  • 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 16.0 7.9 8.0 3.7 10.3 6.7 0.5 1.0 3.5 1.3 1.3 1.9 1.5 1.9 1.3 1.5 0.8 1.0 0.5 1.0 0.5 1.0 1.3 1.5 1.3 1.0 0.3 0.5 0.5 1.0 0.5 0.6 0.3 0.5 0.3 0.5 0.3 0.5 1.5 2.5 6.3 2.3 7.5 3.0 0.8 2.3 0.8 0.8 0.3 1.3 0.5 0.3 0.3 0.5 0.5 0.3 0.3 0.5 0.3 1.7 3.7 3.3 2.6 7.1 2.2 0.5 1.0 1.0 1.0 0.5 1.9 0.6 0.5 0.5 0.6 1.0 0.5 0.5 0.6 0.5 7.3 12.0 3.5 3.7 6.8 5.6 8.5 12.3 4.8 1.7 3.8 4.8 2.0 2.2 0.5 1.0 2.8 4.9 1.0 1.4 2.8 2.8 1.8 1.5 0.8 0.5 1.0 1.4 0.3 0.5 1.3 1.9 0.3 0.5 0.3 0.5 0.3 0.5 1.0 0.8 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.5 0.6 0.5 1.0 0.3 0.5 0.5 0.6 0.3 0.5 0.3 0.5 11.9 7.8 5.2 5.0 2.8 2.8 1.9 1.8 1.6 1.0 0.9 0.8 0.6 0.6 0.5 0.4 0.4 0.4 0.3 0.3 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 Lissothuria nutriens Lepidozona spp.Homolo. lunidumULirularia succincta Anthopleura artemisia Anthopleura elegantissima Lottia ochracea Nereididae Romaleon antennarius Leptasterias spp.Pycnopodia helianthoides Loxorhynchus spp.(table continued) 0 ESLO2014-02 G-7 Appendix G -Subtidal Invertebrates Table G5 (continued).

Subtidal invertebrates (SFQ Method) survey means (abundance per 0.25 M 2;percent cover) standard deviations and annual means, South Diablo Cove Station SDC 2 -3m (12-10).Survey 160 161 162 163 Survey Date 31-Jan-13 19-Apr-13 18-Jul-13 17-Oct-13 Std. Std. Std. Std. -Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Ocinebrina spp. 0.3 0.5 <0.1 Phidiana hiltoni 0.3 0.5 <0.1 Ophioplocus esmarki 0.3 0.5 <0.1 Pisaster giganteus

--0.3 0.5 <0.1 Majidae 0.3 0.5 ----<0.1 Cancridae

--0.3 0.5 <0.1 Flabellina trilineata 0.3 0.5 <0.1 Chama spp. 0.3 0.5 <0.1 Eupentacta quinquesemita 0.3 0.5 --<0.1 Invertebrate Cover Balanus/Tetraclita spp. 0.5 0.9 0.3 0.5 0.6 0.5 0.3 Acanthancora cyanocrypta 0.1 0.3 ----<0.1 bryozoa (encrusting)

<0.1 0.1 <0.1 <.01 <0.1 <.01 <0.1 <.01 <0.1 tunicates, compound/social

<0.1 0.1 <0.1 <.01 <0.1 <.01 <0.1 <.01 <0.1 Porifera (encrusting)

<0.1 0.1 -<0.1 <.01 <0.1 <.01 <0.1 Spirorbidae

<0.1 <.01 <0.1 -<0.1 <.01 <0.1 Hydroidolina

<0.1 <.01 <0.1 Salmacina tribranchiata I ----<0.1 <.01 <0.1 IN-- ESLO2014-02 G-8 Appendix G -Subtidal Invertebrates Table G6. Subtidal invertebtates (SFQ Method) survey means (abundance per 0.25 M 2; percent cover)standard deviations and annual means, South Diablo Cove Station SDC 3 -4m (10-15).Survey 160 161 162 163 Survey Date 14-Feb-13 22-Apr-13 24-Jul-13 25-Oct-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts Balanophyllia elegans Chaetopteridae Phragmatopoma califomica Serpulidae Anthopleura elegantissima Ophiothrix spiculata Pista spp.Amphissa spp.Alia spp.Diopatra omata Pagurus spp.Mitra idae Diopatra spp.Paracyathus stearnsii Sabellidae Strongylocentrotus purpuratus Pelecypoda boring Anthozoa Serpulorbis squamigerus Doriopsilla albopunctata Tethya califomiana Sipuncula Acmaea mitra Loxorhynchus spp.Corynactis californica Leptastefias spp.Patiria miniata Ocinebrina spp.Ophiuroidea Scyra acutifrons Epiactis prolifera Hermissenda crassicornis Pseudomelatoma torosa Pisaster giganteus Pugettia spp.Heptacarpus spp.Dendropoma spp.Cucumaria spp.Anthopleura artemisia Crepidula spp.Conus californicus Pycnopodia helianthoides Ischnochitonidae 30.0 1.5 0.3 1.0 2.0 0.5 1.8 0.8 0.5 1.5 0.8 0.5 0.5 0.8 0.8 0.5 0.3 0.3 0.3 0.8 1.0 0.5 1.0 0.3 0.3 0.5 0.3 0.3 0.3 0.3 12.0 1.9 0.5 0.8 2.0 1.0 1.7 1.0 1.0 1.7 1.5 0.6 1.0 0.5 0.5 1.0 0.5 0.5 0.5 1.0 1.2 0.6 2.0 0.5 0.5 0.6 0.5 0.5 0.5 0.5 21.0 6.3 5.0 2.5 1.3 1.0 1.8 2.0 1.5 0.3 0.5 0.5 0.3 0.5 1.0 0.3 0.3 10 0.3 0.3 0.3 0.5 0.3 0.3 0.3 0.3 0.3 0.3 7.9 4.5 6.1 1.3 1.3 1.4 2.4 1.4 1.9 0.5 1.0 1.0 0.5 1.0 1.4 0.5 0.5 0.8 0.5 0.5 0.5 0.6 0.5 0.5 0.5 0.5 0.5 0.5 22.8 14.8 3.8 1.5 2.0 0.8 2.8 1.0 1.3 1.9 1.5 0.6 1.3 1.9 1.3 1.3 1.0 2.0 0.3 0.5 1.3 1.9 1.3 1.3 1.0 0.8 0.5 0.6 1.3 0.5 0.8 1.0 0.5 0.6 0.3 0.5 0.3 0.5 0.3 0.5 0.5 0.6 0.5 0.6 1.0 0.8 0.5 0.6 0.5 0.6 0.3 0.5 0.3 0.5 0.8 1.0 0.5 0.6 24.3 8.0 5.8 1.8 1.5 2.3 1.0 1.5 2.5 2.0 1.8 3.0 0.5 0.8 0.8 0.3 0.8 0.3 0.8 0.3 0.3 0.3 0.8 0.3 0.3 0.3 0.3 0.8 0.3 0.3 0.3 0.3 18.7 4.1 3.3 1.0 1.0 2.2 0.8 0.6 1.3 0.8 1.7 3.8 1.0 0.5 1.0 0.5 1.0 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 1.0 0.5 0.5 0.5 0.5 24.5 3.9 2.8 2.3 1.7 1.6 1.4 1.4 1.1 1.1 1.0 0.8 0.8 0.7 0.6 0.6 0.6 0.5 0.5 0.5 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 (table continued) 0NW ESLO2014-02 G-9 Appendix G -Subtidal Invertebrates Table G6. (continued)

Subtidal invertebrates (SFQ Method) survey means (abundance per 0.25 m 2;percent cover) standard deviations and annual means, South Diablo Cove Station SDC 3 -4m (10-15).Survey 160 161 162 163 Survey Date 14-Feb-13 22-Apr-13 24-Jul-13 25-Oct-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Majidae --0.5 0.6 0.1 Lottiidae

--0.3 0.5 --<0.1 Lottia ochracea 0.3 0.5 --<0.1 tunicate, solitary --0.3 0.5 <0.1 Ophioplocus esmarki ----0.3 0.5 <0.1 Cryptolithodes sitchensis 0.3 0.5 --<0.1 Mimulus foliatus ----0.3 0.5 <0.1 Cancridae 0.3 0.5 --<0.1 Lophopenopeus spp. --0.3 0.5 <0.1 Paraxanthias taylori 0.3 0.5 --<0.1 CirratulidaelTerebellidae 0.3 0.5 --<0.1 Eupentacta quinquesemita

--0.3 0.5 <0.1 Romaleon jordani --0.3 0.5 <0.1 Ophiactis simplex 0.3 0.5 --<0.1 Doris spp. ---0.3 0.5 <0.1 Invertebrate Cover Balanus/-etraclita spp. 1.3 1.8 0.5 0.7 126.7 90.9 67.2 51.4 48.9 Acanthancora cyanocrypta 0.5 0.5 0.8 0.3 0.3 0.5 0.6 0.8 0.6 Porifera (encrusting) 0.1 0.3 <0.1 -0.3 0.2 0.3 0.5 0.2 tunicates, compound/social 0.1 0.2 <0.1 <.01 0.5 0.4 <0.1 -0.2 bryozoa (encrusting)

<0.1 -<0.1 0.1 <0.1 0.1 0.1 0.2 <0.1 Spirorbidae

-<0.1 -<0.1 --<0.1 Hydroidolina

<0.1 <.01 -<0.1 f4W ESLO2014-02 G-1I0 Appendix G -Subtidal Invertebrates Table G7. Subtidal invertebrates (SFQ Method) survey means (abundance per 0.25 m 2; percent cover)standard deviations and annual means, South Control Station SC I -3m (19-10).Survey 160 161 162 163 Survey Date 14-Mar-13 26-Apr-13 12-Aug-13 30-Oct-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts Phragmatopoma califomica Pagurus spp.Homolo. luridurm/Lirularfa succincta Chlorostoma brunnea Dendropoma spp.Amphissa spp.Pista spp.Lottia instabilis Pugettia spp.Balanophyllia elegans Alia spp.Epiactis prolifera Tonicella lineata Leptasterias spp.Mitra idae Lirobiftium spp.Crepidula spp.Diopatra omata Pati/ia miniata Loxorhynchus spp.Mimulus foliatus Serpulidae Anthopleura elegantissima Hermissenda crassicornis Cryptochiton stelleri Pisaster/Henricia spp. (juv.)Anthopleura artemisia Acmaea mitra Chlorostorna montereyi Rornaleon antennarius Aptyxis luteopictus Ocinebrina spp.Pseudomelatoma torosa Ophiuroidea Scyra acutifrons Lissothuria nutriens Urticina spp.Calliostoma ligaturm Lottiidae Promaitynia pulligo Sabellidae Pycnopodia helianthoides tunicate.

solitarv 56.5 112.3 7.5 11.0 5.3 1.7 0.8 1.0 14.3 27.2 0.3 0.5 1.0 2.0 0.3 0.5 0.8 1.5 1.8 2.2 0.5 0.6 0.5 0.6 0.5 0.6 0.3 0.5 0.3 0.5 0.8 1.0 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 70.3 136.5 1.5 1.9 5.5 3.1 8.0 3.9 1.3 0.5 1.3 2.5 0.5 0.6 1.0 1.4 1.0 0.8 0.5 0.6 1.0 0.8 0.5 0.6 0.8 0.5 0.3 0.5 0.3 0.5 0.5 1.0 0.3 0.5 0.3 0.5 0.3 0.5 0.5 1.0 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 254.8 496.2 13.0 8,5 10.3 6.1 8.5 4.0 0.3 0.5 1.3 1.9 0.8 1.5 2.5 1.0 0.5 1.0 0.5 1.0 0.8 1.5 0.5 0.6 0.5 0.6 0.3 0.5 0.8 1.0 0.8 0.5 0.5 1.0 0.8 1.0 0.3 05 0.3 0.5 0.5 0.6 0.3 0.5 0.5 1.0 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 95.8 186.2 6.0 1.4 1.3 1.0 4.0 0.8 2.0 1.4 1.3 1.5 0.8 0.5 1.3 1.3 1.0 1.2 0.5 0.6 0.5 0.6 0.8 0.5 1.0 0.8 0.8 1.5 0.5 1.0 0.5 0.6 0.8 0.5 0.8 1.0 0.5 0.6 0.3 0.5 0.5 0.6 0.5 0.6 0.3 0.5 0.3 0.5 0.3 0.5 0.5 0.6 0.3 0.5 0.3 0.5 0.5 1.0 0.3 0.5 0.5 0.6 0.3 0.5 119.3 7.0 5.6 5.3 3.6 1.2 1.1 1.0 0.9 0.8 0.6 0.5 0.5 0.5 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 (table continued) 4a----WESLO2014-02 G-1 1 Appendix G -Subtidal Invertebrates Table G7 (continued).

Subtidal invertebrates (SFQ Method) survey means (abundance per 0.25 M 2;percent cover) standard deviations and annual means, South Control Station SC I -3m (19-10).Survey 160 161 162 163 Survey Date 14-Mar-13 26-Apr-13 12-Aug-13 30-Oct-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Pelecypoda boring 0.3 0.5 <0.1 Ophiothrix spiculata 0.3 0.5 --<0.1 Ceratostoma foliatum --0.3 0.5 <0.1 Cancridae 0.3 0.5 -- <0.1 Heptacarpus spp. --0.3 0.5 <0.1 Triopha spp. 0.3 0.5 --<0.1 Lepidozona spp. ------0.3 0.5 <0.1 Invertebrate Cover tunicates, compound/social 0.6 1.1 0.5 1.0 0.8 1.0 <0.1 -0.5 Porifera (encrusting) 1.5 0.6 <0.1 -<0.1 0.1 <0.1 -0.4 Balanus/Tetraclita spp. 0.3 0.5 0.2 0.3 0.5 0.7 0.5 0.6 0.3 bryozoa (encrusting) 0.6 0.5 <0.1 -0.1 0.3 <0.1 -0.2 Spirorbidae

<0.1 0.1 <0.1 -<0.1 -<0.1 <0.1 Salmacina tfribranchiata

--<0.1 <.01 <0.1 <.01 <0.1 <0.1 Hydroidolina

--<0.1 <0.1 Dodecaceria fewkesi -I --<0.1 <.01 <0.1 0 ESLO2014-02 G-12 Appendix G -Subtidal Invertebrates Table G8. Subtidal invertebrates (SFQ Method) survey means (abundance per 0.25 M 2; percent cover)standard deviations and annual means, South Control Station SC 2 -6m (20-20).Survey 160 Survey Date 13-Mar-13 Std.Taxon Mean Dev.Invertebrate Counts Corynactis californica Balanophyllia elegans Phragmatopoma califomica Serpulorbis squamigerus Homolo. luridum/Lirularia succincta Pagurus spp.Serpulidae Chlorostoma brunnea Dendropoma spp.Ocinebdina spp.Patinia miniata Lottia instabilis Chaetopteridae Pugettia spp.Acmaea mitra Sabellidae Leptasterias spp.Aptyxis luteopictus Pelecypoda borng Crepidula spp.Pista spp.Amphissa spp.Anthopleura elegantissima Epiactis prolifera Doriopsilla albopunctata Calliostoma ligaturm Promartynia pulligo Pycnopodia helianthoides Eulithidium spp.Pododesmus cepio Pisaster/Henicia spp. (uv.)Sipuncula Paracyathus stearnsii Lottia insessa Ophiothrix spiculata Eupentacta quinquesemita Tethya californiana Mitra idae Scyra acutifrons Cancridae Ceratostoma foliatum Lottiidae Tonicella lineata 98.0 99.9 74.8 101.2 23.8 17.0 7.8 9.5 7.8 7.9 3.8 5.6 1.8 1.5 0.5 1.0 3.8 4.8 2.0 2.2 1.5 1.7 1.5 3.0 1.0 0.8 1.0 1.2 1.3 2.5 0.8 1.5 1.0 2.0 1.0 1.4 0.3 0.5 0.3 0.5 0.5 0.6 0.3 0.5 0.3 0.5 0.5 1.0 0.3 0.5 0.3 0.5 0.3 0.5 161 162 9-May-13 14-Aug-13 Std. Std.Mean Dev. Mean Dev.65.3 66.5 55.0 62.6 57.3 71.1 46.3 39.0 19.3 13.5 6.3 6.0 7.3 9.3 4.3 1.7 6.8 3.1 2.0 1.4 1.0 1.2 3.0 2.6 2.0 1.8 3.3 1.7 0.3 0.5 5.0 4.1 2.3 3.9 --0.8 1.5 1.0 0.8 0.5 0.6 1.5 1.3 1.5 1.9 --0.8 1.5 2.8 3.2 0.3 0.5 0.3 0.5 0.8 1.0 0.5 0.6 1.0 2.0 0.3 0.5 0.3 0.5 1.3 0.5--2.8 1.3 1.3 1.3 0.3 0.5 0.3 0.5 --0.3 0.5 1.5 3.0 1.0 0.8 1.0 0.8 0.3 0.5 0.8 0.5--0.8 0.5 0.3 0.5 1.0 0.8 0.8 1.0 0.5 1.0 0.3 0.5 0.8 0.5 1.5 3.0 0.5 1.0 0.3 0.5--0.8 1.0 0.3 .0.5 0.5 1.0 1.0 0.8 0.3 0.5 0.3 0.5 0.5 0.6 0.3 0.5 0.5 1.0 0.5 0.6 0.3 0.5 0.5 1.0 --0.3 0.5 0.3 0.5 163 25-Nov-13 Std. Annual Mean Dev. Mean 71,8 76.2 58.0 75.3 7.5 6.5 10.5 10.7 3.3 6.5 1.3 1.0 0.5 0.6 0.8 0.5 0.5 1.0 2.0 2.8 1.0 1.2 0.8 1.0 1.8 1.3 0.8 1.0 0.3 0.5 0.5 1.0 1.0 2.0 0.3 0.5 0.5 1.0 0.8 1.5 1.0 0.8 0.3 0.5 0.3 0.5 0.3 0.5 0.8 1.5 0.5 0.6 0.5 0.6 0.3 0.5 0.5 0.6 0.3 0.5 0.5 1.0 0.3 0.5 0.8 0.5 0.3 0.5 72.5 59.1 14.2 7.4 4.9 2.3 1.9 1.6 1.6 1.4 1.1 0.9 0.9 0.8 0.8 0.7 0.7 0.7 0.6 0.6 0.5 0.5 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.1 0.1 0.1 (table continued)

G-13 Appendix G -Subtidal Invertebrates Table G8 (continued).

Subtidal invertebrates (SFQ Method) survey means (abundance per 0.25 M 2;percent cover) standard deviations and annual means, South Control Station SC 2 -6m (20-20).Survey 160 161 162 1 163 Survey Date 13-Mar-13 9-May-13 14-Aug-13 25-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Invertebrate Counts (continued)

Pomaulax gibberosa Pseudomelatoma torosa Cucumaria spp.Anthopleure artemisia Anthozoa Diodora spp.Alia spp.Hermissenda crassicomis Chlorostoma montereyi Strongylocentrotus purpuratus Phidiana hi/toni Ischnochitonidae Cryptochiton stelleri Ophioplocus esmarki Pisaster giganteus Eudistylia polymorpha Cryptolithodes sitchensis Mimulus foliatus Doris spp.Invertebrate Cover Balanusetraclitat spp.Acanthancora cyanocrypta bryozoa (encrusting)

Porifera (encrusting) tunicates, compound/social Hydroidolina bryozoa (erect)Spirorbidae Abiet./Sertularella/Sertularia spp.brvozoa (foliosel 0.3 0.5 0.5 1.0 0.3 0.5 0.3 0.5 6.5 8.6 1.2 1.1 0.8 1.2 0.9 0.8<0.1<0.1 < .01<0.1 0.1 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 26.5 21.1 0.9 0.8 C.6 1.0 0.4 0.5 0.6 0.5 0.3 0.3<0.1 <.01<0.1 <.01 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 141.7 103.1 0.4 0.5 0.6 0.2 0.7 0.4 0.5 0.2<0.1<0.1 <.01<0.1<0.1 <.01 0.3 0.5 0.3 0.5 0.3 0.5 141.8 135.6 1.4 1.5 1.0 0.7 0.6 0.5<0.1 <.01<0.1 <.01<0.1<0.1 <.01 0.1 0.1 0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 79.1 1.0 0.7 0.6 0.3<0.1<0.1<0.1<0.1<0.1 WNW- ESLO2014-02 G-14 Diablo Canyon Power Plant Appendix H Subtidal Fishes (SFO Method)

Appendix H -Subtidal Fishes Table HI. Subtidal fishes survey means (abundance per 50 x 4 x 2 m transect), standard deviations and annual means, Field's Cove Stations (FC FO-1 (1), FC FO-2 (2), FC FO-3 (3)).Survey 158 159 160 161 Survey Date 24-Mar-13 18-Jun-13 7-Sep-13 29-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Midwater Sebastes serranoidesIS.

flavidus (yoy) --18.0 14.2 32.3 28.8 1.0 0.8 12.8 Aulorhynchus flavidus 5.3 13.1 0.2 0.3 --18.8 45.9 6.1 Sebastes mystinus (yoy) --6.3 12.9 9.8 12.7 5.4 6.5 5.4 Oxyjulis californica

--0.4 0.8 2.2 3.0 3.3 3.7 1.5 Rhacochilus vacca 0.3 0.3 0.3 0.6 1.7 4.1 0.2 0.4 ,0.6 Oxyjulis califomica (juv.) 1.2 2.9 0.5 0.8 ----0.4 Brachyistius frenatus --0.2 0.3 0.8 1.4 0.4 0.5 0.3 Sebastes atrovirens

--1.0 1.1 0.3 0.4 --0.3 Rhacochilus vacca (juv.) <0.1 0.2 --0.6 0.6 --0.2 Embiotoca lateralis 0.4 0.7 --<0.1 0.2 0.2 0.4 0.2 Sebastes serranoides

--0.3 0.4 <0.1 0.2 --<0.1 Sebastes mystinus ---0.3 0.8 <0.1 Sebastes paucispinis (juv.) --0.2 0.4 --<0.1 Rhacochilus toxotes --<0.1 0.2 --<0.1 Embiotocajacksoni

<0.1 0.2 --<0.1 Sebastes mystinus (juv.) --<0.1 0.2 <0.1 Embiotoca lateralis (juv.) <0.1 0.2 --<0.1 Benthic Sebastes mystinus (yoy) 15.3 2.5 28.8 13.9 18.8 10.1 15.7 Sebastes serranoidesIS.

flavidus (yoy) --7.2 5.0 8.9 14.1 1.0 0.6 4.3 Oxyjulis califomica (juv.) 3.8 9.2 12.3 12.4 <0.1 0.2 --4.0 Oxylebius pictus 3.6 2.3 3.2 1.9 4.9 4.1 3.9 1.5 3.9 Rhacochilus vacca (juv.) --<0.1 0.2 9.2 11.7 <0.1 0.2 2.3 Oxyjulis califomica

--1.0 1.1 3.2 4.8 1.6 1.8 1.4 Embiotoca lateralis 1.6 1.2 1.0 1.3 1.1 1.1 1.2 0.8 1.2 Rhacochilus vacca 2.0 3.7 0.8 0.9 1.7 2.4 0.3 0.4 1.2 Gibbonsia spp. 0.8 0.4 1.0 1.1 0,8 0.8 1.9 2.1 1.1 Sebastes chrysomelas 0.7 0.8 1.4 0.9 1.3 0.4 1.0 1.1 1.1 Embiotoca lateralis (juv.) 0.8 0.5 0.5 0.6 1.5 1.1 1.3 0.9 1.0 Sebastes rastrelliger 1.0 0.5 0.4 0.6 0.9 0.7 0.6 0.6 0.7 Embiotocajacksoni (juv.) 0.3 0.4 0.3 0.4 1.8 2.0 0.5 0.8 0.7 Sebastes atrovirens 0.4 0.6 1.1 1.2 0.5 0.3 0.7 0.8 0.7 Scorpaenichthys marmoratus 0.7 0.3 0.6 1.0 0.3 0.6 0.9 0.7 0.6 Embiotocajacksoni 0.8 0.4 0.3 0.3 0.8 0.7 0.3 0.3 0.5 Sebastes chrysomelas (juv.) 0.2 0.4 0.3 0.4 0.6 1.0 0.4 0.2 0.4 Sebastes melanops (yoy) --0.8 1.8 0.3 0.4 --0.3 Hypsurus caryi (juv.) ----1.0 2.0 --0.3 Rhacochilus toxotes 0.3 0.4 0.3 0.4 --0.3 0.5 0.2 Aulorhynchus flavidus 0.8 2.0 ----0.2 Brachyistius frenatus ------0.8 1.3 0.2 Hexagrammos decagrammus 0.4 0.6 <0.1 0.2. <0.1 0.2 0.2 0.3 0.2 Cebidichthys violaceus 0.3 0.4 <0.1 0.2 0.2 0.3 0.3 0.6 0.2 Hypsurus caryi ----0.5 1.2 --0.1 Orthonopias triacis <0.1 0.2 <0.1 0.2 0.2 0.4 0.2 0.3 0.1 Artedius spp. ----0.3 0.4 --<0.1 (table continued)

F4 ESL02014-02 H-1 Appendix H -Subtidal Fishes Table Hi (continued).

Subtidal fishes survey means (abundance per 50 x 4 x 2 m transect), standard deviations and annual means, Field's Cove Stations (FC FO-l (1), FC FO-2 (2), FC FO-3 (3)).Survey 158 159 160 161 Survey Date 24-Mar-13 18-Jun-13 7-Sep-13 29-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Benthic (continued)

Brachyistius frenatus (juv.) --0.3 0.6 <0.1 Rhacochilus toxotes (juv.) --0.3 0.4 --<0.1 Semicossyphus pulcher --0.2 0.3 <0.1 0.2 <0.1 Ophiodon elongatus 0.2 0.4 ----<0.1 Sebastes chrysomel.S.

camatus (yoy) <0.1 0.2 <0.1 0.2 <0.1 Sebastes serranoides


<0.1 0.2 <0.1 Rhinogobiops nicholsi <0.1 0.2 --<0.1 Sebastes rastrelliger (juv.) <0.1 0.2 <0.1 Oxylebius pictus (juv.) <0.1 0.2 <0.1 45NESLO2014-02 H-2 Appendix H -Subtidal Fishes Table H2. Subtidal fishes survey means (abundance per 50 x 4 x 2 m transect), standard deviations and annual means, North Diable Cove Stations (NDC FO-1 (5), NDC FO-2 (6), NDC FO-3 (7)).Survey 158 159 160 161 Survey Date 24-Mar-13 18-Jun-13 7-Sep-13 28-Nov-13 Std. StdD Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Midwater Sebastes serranoidesIS.

flavidus (yoy)Sebastes mystinus (yoy)Atherinopsidae Oxyjulis califomica Sebastes serranoides Brachyistius frenatus Oxyjulis califomica (uv.)Sebastes atrovirens Embiotoca jacksoni Brachyistius frenatus (juv.)Atherinopsis califomiensis Rhacochilus vacca (juv.)Rhacochilus vacca Girella nigricans Medialuna californiensis Rhacochilus toxotes Sebastes paucispinis (juv.)Embiotoca jacksoni Ouv.)Triakis semifasciata Semicossyphus pulcher Hypsypops rubicundus Gibbonsia spp.Embiotoca lateralis Paralabrax clathratus Sebastes chrysomeLIS.

camatus (yoy)Benthic Sebastes mystinus (yoy)Sebastes serranoidesIS.

flavidus (yoy)Oxyjulis califomica Oxylebius pictus Embiotocajacksoni Embiotocajacksoni (juv.)Rhacochilus vacca juv.)Oxyjulis califomica (juv.)Rhinogobiops nicholsi Brachyistius frenatus Rhacochilus vacca Sebastes chrysomelas Gibbonsia spp.Girella nigricans Sebastes serranoides Sebastes rastrelliger Embiotoca lateralis Sebastes rastrelliger (juv.)0.2 0.3<0.1 0.2 0.8 1.0<0.1 0.2 0.3 0.8 0.3 0.4<0.1 0.2 11.5 14.2 3.8 7.6 1.8 1.0 1.1 2.4 0.6 1.2 1.3 2.4 0.7 1.0<0.1 0.2 0.7 0.8 1.1 2.2 0.3 0.4 0.3 0.6<0.1 0.2 0.2 0.4<0.1 0.2<0.1 0.2<0.1 0.2 28.5 17.5 16.5 16.7 6.8 5.9 3.8 3.4 3.8 1.4 6.2 4.0 4.4 3.4 3.9 4.0 2.5 2.2 0.9 0.7 1.7 1.5 0.5 0.6 0.8 0.7 0.7 0.8 0.5 0.8 0.3 0.4 0.3 0.6 13.0 5.8 11.7 0.7 2.0 1.4 0.3<0.1 0.4 0.3<0.1 57.3 23.3 3.0 5.3 6.3 6.3 6.6 0.4 3.0 0.5 1.2 0.8 1.3<0.1 0.7 1.3 0.8 0.8 14.8 5.6 24.0 0.6 4.2 1.7 0.5 0.2 0.8 0.8 0.2 39.6 12.2 3.6 5.2 3.8 3.6 4.2 0.8 2.1 0.8 1.0 0.9 1.9 0.2 1.2 2.8 1.2 0.9 15.5 6.0 26.7 13.1 1.3 1.7 0.4 0.5 0.9 1.2 0.3 0.8 0.3 0.5 0.3 0.4 0.3 0.4 0.2 0.4 0.2 0.4<0.1 0.2 0.2 0.4<0.1 0.2 10.0 9.1 2.9 0.9 0.9 0.7 0.5 0.4 0.3 0.3 0.3 0.2<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1<0.1 38.0 15.2 5.4 5.3 4.5 4.5 3.5 3.1 2.8 1.9 1.1 0.9 0.8 0.8.0.7 0.4 0.4 0.4 0.5 4.4 4.6 4.2 1.8 0.3 8.3 3.2 0.3 0.5 0.8 0.5 2.3 0.6 0.4 0.5 0.2 0.8 10.3 2.6 1.9 1.2 0.6 11.4 2.1 0.8 1.0 0.9 0.3 5.0 1.2 0.6 0.6 0.3 66.4 20.5 7.5 7.3 3.8 3.6 2.7 2.7 5.8 1.1 1.6 0.8 0.3 1.1 0.2 0.4 41.1 11.8 10.4 2.5 2.5 1.6 3.5 1.8 12.0 1.3 1.7 0.8 0.4 1.7 0.3 0.8 (table continued) o-w ESLO2014-02 H-3 Appendix H -Subtidal Fishes Table H2 (continued).

Subtidal fishes survey means (abundance per 50 x 4 x 2 m transect), standard deviations and annual means, North Diablo Cove Stations (NDC FO-l (5), NDC FO-2 (6), NDC FO-3 (7)).Survey 158 159 160 161 Survey Date 24-Mar-13 18-Jun-13 7-Sep-13 28-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Benthic (continued)

Semicossyphus pulcher 0.8 0.9 0.3 0.4 --0.4 0.5 0.4 Sebastes melanops (yoy) --0.8 1.3 0.5 1.2 --0.3 Sebastes atrovirens 0.3 0.6 0.3 0.4 0.3 0.4 0.5 0.8 0.3 Embiotoca lateralis (juv.) 0.2 0.4 0.3 0.5 <0.1 0.2 0.7 1.4 0.3 Brachyistius frenatus (juv.) ----<0.1 0.2 1.2 1.2 0.3 Sebastes chrysomel/S.

camatus (yoy) 0.9 1.3 <0.1 0.2 --0.3 Hypsurus caryi (juv.) <0.1 0.2 0.7 1.2 0.2 Oxylebius pictus (juv.) 0.6 1.0 0.2 0.4 0.2 Hypsurus caryi 0.5 0.6 ----0.1 Scorpaenichthys rnarmoratus

--0.2 0.3 0.3 0.4 0.1 Sebastes chrysomelas (juv.) 0.3 0.3 0.2 0.3 --0.1 Hypsypops nibicundus

<0.1 0.2 0.2 0.3 0.3 0.4 0.1 Scorpaenichthys marmoratus (juv.) --0.4 0.4 ----0.1 Rhacochilus toxotes <0.1 0.2 <0.1 0.2 <0.1 0.2 0.2 0.3 0.1 Orthonopias triacis <0.1 0.2 <0.1 0.2 --0.2 0.3 <0.1 Ophiodon elongatus 0.2 0.3 <0.1 0.2 --<0.1 0.2 <0.1 Sebastes paucispinis (juv.) --0.3 0.6 <0.1 0.2 --<0.1 Artedius spp. 0.2 0.3 <0.1 0.2 <0.1 0.2 <0.1 Sebastes caurinus (yoy) --0.2 0.4 0.2 0.4 -<0.1 Urobatis halleri 0.3 0.3 ----<0.1 Paralabrax clathratus (juv.) ----0.2 0.4 <0.1 Triakis semifasciata 0.2 0.3 --<0.1 Cottidae 0.2 0.4 <0.1 Heterostichus rostratus

<0.1 0.2 <0.1 Hexagrammos decagrarnmus (juv.) --<0.1 0.2 <0.1 Paralabrax clathratus

<0.1 0.2 --<0.1 f-4 ESLO2014-02 H-4 Appendix H -Subtidal Fishes Table 113. Subtidal fishes survey means (abundance per 50 x 4 x 2 m transect), standard deviations and annual means, South Diablo Cove Stations (SDC FO-1 (8), SDC FO-2 (9), SDC FO-3 (10)).Survey 158 159 160 161 Survey Date 27-Mar-13 1-Jul-13 10-Sep-13 28-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Midwater Sebastes serranoides/S.

flavidus (yoy) 0.8 1.3 28.8 17.3 35.3 31.4 1.8 2.7 16.7 Sebastes mystinus (yoy) --4.4 6.8 13.1 11.7 0.9 2.0 4.6 Brachyistius frenatus 1.8 3.1 2.1 1.5 5.0 4.0 2.4 2.7 2.8 Oxyjulis californica (uv.) 9.4 18.6 ------2.4 Brachyistius frenatus (juv.) --5.6 7.3 2.1 3.6 1.1 1.5 2.2 Atherinopsis californiensis 5.4 7.8 ----1.4 Oxyjulis californica 0.8 1.6 3.4 3.7 --1.0 Rhacochilus vacca 2.9 7.1 <0.1 0.2 <0.1 0.2 0.8 Atherinopsidae


1.7 4.1 0.4 Sebastes paucispinis (juv.) 1.2 2.6 --0.3 Aulorhynchus flavidus 0.9 2.0 ----0.2 Sebastes atrovirens

--0.4 0.5 --<0.1 0.2 0.1 Rhacochilus vacca (juv.) 0.2 0.3 <0.1 0.2 --<0.1 Sebastes caurinus (yoy) 0.3 0.6 --<0.1 Sebastes chrysomeLIS.

camatus (yoy) 0.3 0.6 <0.1 Embiotocajacksoni 0.2 0.3 <0.1 Embiotocajacksoni (juv.) <0.1 0.2 --<0.1 Benthic Sebastes serranoides/S.

flavidus (yoy) 106.3 60.2 27.8 6.8 1.9 2.6 34.0 Sebastes mystinus (yoy) 35.2 39.2 31.0 17.2 5.4 6.5 17.9 Oxylebius pictus 1.3 1.4 1.4 1.3 4.2 2.5 2.3 2.4 2.3 Sebastes mystinus --8.3 20.4 ----2.1 Citharichthys spp. 0.2 0.4 2.2 2.3 2.4 1.4 1.3 2.1 1.5 Sebastes chrysomelas 1.2 1.4 0.4 0.8 2.3 1.1 1.8 1.4 1.4 Sebastes caurinus (yoy) --4.2 6.1 1.3 1.2 --1.4 Sebastes chrysome/IS.

carnatus (yoy) --4.3 5.5 0.3 0.4 --1.1 Rhinogobiops nicholsi 0.8 0.6 1.3 1.4 1.9 1.7 0.3 0.6 1.1 Rhacochilus vacca <0.1 0.2 2.7 4.8 0.3 0.6 0.9 1.2 1.0 Rhacochilus vacca (juv.) --1.8 1.9 0.9 1.1 --0.7 Sebastes atrovirens 1.3 1.1 0.8 0.6 0.5 0.8 0.7 Brachyistius frenatus 0.5 0.8 0.3 0.4 1.8 1.4 0.6 Gibbonsia spp. 0.3 0.3 <0.1 0.2 1.3 0.3 0.6 0.6 0.6 Embiotoca lateralis 0.3 0.4 <0.1 0.2 0.8 0.5 0.5 0.6 0.4 Sebastes rastrelliger 0.4 0.6 0.4 0.5 0.3 0.3 0.3 0.5 0.4 Embiotocajacksoni 0.3 0.4 0.2 0.3 0.5 0.3 0.4 0.7 0.4 Ophiodon elongatus

--0.6 0.6 0.4 0.4 0.3 0.4 0.3 Citharichthys spp. (uv) --0.3 0.6 0.2 0.3 0.5 1.2 0.2 Brachyistius frenatus (uv.) <0.1 0.2 0.3 0.4 <0.1 0.2 0.3 0.6 0.2 Sebastes paucispinis (juv.) --0.8 1.0 ----0.2 Oxyjulis califomica 0.5 0.8 0.2 0.3 0.2 Sebastes melanops (yoy) 0.7 0.5 ----0.2 Sebastes miniatus (yoy) --0.7 1.2 0.2 Rhacochilus toxotes 0.5 1.0 0.1 Pleuronichthy*

coenosus <0.1 0.2 0.4 0.7 -0.1 (table continued) 4 ESLO 2014-02 H-5 Appendix H -Subtidal Fishes Table H3 (continued).

Subtidal fishes survey means (abundance per 50 x 4 x 2 m transect), standard deviations and annual means, South Diablo Cove Stations (SDC FO-1 (8), SDC FO-2 (9), SDC FO-3 (10)).Survey 158 159 160 161 Survey Date 27-Mar-13 1-Jul-13 10-Sep-13 28-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Benthic (continued)

Embiotocajacksoni (juv.) 0.3 0.4 0.2 0.4 --0.1 Artedius spp. 0.2 0.3 0.2 0.3 0.2 0.3 0.1 Aulorhynchus flavidus 0.4 0.6 ----0.1 Orthonopias triacis --0.4 0.5 0.1 Rhinogobiops nicholsi (juv.) 0.4 0.8 --0.1 Oxyjulis califomica (juv.) 0.3 0.6 ----<0.1 Neoclinus stephensae


0.3 0.4 <0.1 Scorpaenichthys marmoratus

<0.1 0.2 0.2 0.3 <0.1 Hexagrammos decagrammus

--<0.1 0.2 0.2 0.3 <0.1 Triakis semifasciata

--0.3 0.3 --<0.1 Embiotoca lateralis Ouv.) 0.2 0.3 --<0.1 Scorpaenichthys marmoratus (iuv.) <0.1 0.2 <0.1 0.2 <0.1 Hypsurus caryi --<0.1 0.2 <0.1 Sebastes rastrelliger (juv.) --<0.1 0.2 <0.1 Lethops connectens

--<0.1 0.2 --<0.1 Urobatis halleri <0.1 0.2 ----<0.1 Pleuronichthys coenosus (yoy) ---<0.1 0.2 <0.1 W ESLO2014-02 H-6 Appendix H -Subtidal Fishes Table H4. Subtidal fishes survey means (abundance per 50 x 4 x 2 m transect), standard deviations and annual means, Patton Cove Stations SC FO-1 (12), SC FO-2 (13), SC FO-3 (14).Survey 158 159 160 161 Survey Date 27-Mar-13 1-Jul-13 10-Sep-13 27-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Midwater Sebastes mystinus (yoy)Sebastes serranoidesIS.

flavidus (yoy)Oxyjulis califomica Rhacochilus vacca Oxyjulis califomica (juv.)Sebastes mystinus Brachyistius frenatus (juv.)Sebastes serranoides Brachyistius frenatus Sebastes mystinus (uv.)Sebastes atrovirens Sebastes melanops (yoy)Embiotoca lateralis Sebastes melanops Sebastes paucispinis (uv.)Rhacochilus vacca (uv.)Myliobatis califomica Benthic Sebastes mystinus (yoy)Oxylebius pictus Sebastes serranoidesIS.

flavidus (yoy)Embiotoca lateralis (uv.)Embiotoca lateralis Sebastes chrysomelas Rhacochilus vacca Embiotocajacksoni Sebastes atrovirens Scorpaenichthys marmoratus Hexagrammos decagrammus Sebastes rastrelliger Gibbonsia spp.Orthonopias triacis Sebastes melanops Rhacochilus vacca (uv.)Oxyjulis califomica Embiotocajacksoni (uv.)Sebastes melanops (yoy).Hexagrammos decagrammus juv.)Ophiodon elongatus Oxyjulis califomica (juv.)Brachyistius frenatus Sebastes mystinus (juv.)Artedius spp.Rhinooobioos nicholsi<0.1 0.2<0.1 0.2 0.3 0.8 0.2 0.4<0.1 0.2 0.6 1.2 2.8 1.2 0.7 1.0 1.0 0.6 1.8 1.4 2.8 4.7 1.6 2.0 1.3 1.4 0.5 0.8 0.6 0.4 0.7 1.0 0.2 0.3 0.3 0.4 0.5 0.6 0.2 0.3 0.8 1.6 0.3 0.5 19.4 11.3 0.9<0.1 0.9 0.8<0.1 0.2<0.1 0.3 0.2 0.4 0.2 0.2<0.1 59.3 3.2 3.9 0.3 0.6 1.7<0.1 0.4 0.7 0.6 0.6 0.7 0.4 0.9<0.1<0.1 0.3 1.0 0.5 0.3 0.6<0.1 0.2<0.1 19.3 10.2 1.6 0.2 1.6 1.3 0.2 0.3 0.2 0.6 0.4 1.0 0.4 0.4 0.2 66.9 0.5 5.9 0.3 0.5 2.0 0.2 0.4 0.6 0.6 0.5 0.6 0.4 0.5 0.2 0.2 0.4 2.0 0.8 0.4 0.9 0.2 0.3 0.2 31.8 25.3 3.5 2.1 0.3<0.1 0.2 0.2 0.2 55.4 6.9 9.7 4.3 3.1 2.2 0.6 2.2 1.4 1.0 1.2 0.8 0.9 0.4 0.9 1.4 1.2 0.3<0.1 0.5<0.1 0.6 0.3 0.2 0.2 0.3 31.7 21.8 1.8 5.1 0.8 0.2 0.4 0.3 0.3 26.4 4.3 4.8 2.6 1.0 1.2 0.5 2.1 1.7 0.8 0.8 0.7 0.6 0.6 1.6 0.7 2.9 0.6 0.2 0.5 0.2 1.0 0.6 0.4 0.3 0.8 20.6 1.8 3.8 2.1 0.3 1.0 0.6 0.3 0.3<0.1 26.1 7.3 1.5 2.8 3.2 1.8 3.0 2.1 1.4 1.4 0.7 0.7 0.8 0.5 0.6<0.1 0.3 0.3 0.3 0.6 0.8 0.5 10.8 2.4 3.0 2.8 0.4 2.5 0.6 0.6 0.4 0.2 25.8 1.9 1.5 1.7 2.1 1.0 3.0 1.5 1.1 0.9 0.8 0.6 1.2 0.8 0.7 0.2 0.4 0.6 0.4 0.8 1.4 0.6 18.0 9.6 2.1 1.1 0.3 0.3 0.3 0.2 0.2 0.1 0.1 0.1<0.1<0.1<0.1<0.1<0.1 35.4 5.0 3.8 2.0 2.0 1.9 1.6 1.6 1.2 0.9 0.8 0.7 0.5 0.5 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 (table continued) 40%WEL2040 H-7 Appendix H -Subtidal Fishes Table H4 (continued).

Subtidal fishes survey means (abundance per 50 x 4 x 2 m transect), standard deviations and annual means, Patton Cove Stations SC FO-1 (12). SC FO-2 (13), SC FO-3 (14).Survey 158 159 160 161 Survey Date 27-Mar-13 1-Jul-13 10-Sep-13 27-Nov-13 Std. Std. Std. Std. Annual Taxon Mean Dev. Mean Dev. Mean Dev. Mean Dev. Mean Benthic (continued)

Cebidichthys violaceus 0.4 0.6 0.2 0.3 0.2 0.3 0.2 Oxylebius pictus (uv.) --0.8 1.8 --0.2 Sebastes mystinus <0.1 0.2 0.2 0.4 0.3 0.5 --0.1 Sebastes chrysomelas (juv.) ----0.3 0.4 0.2 0.3 0.1 Scorpaenichthys marmoratus (juv.) --0.3 0.5 <0.1 0.2 --0.1 Rhacochilus toxotes <0.1 0.2 0.2 0.3 --<0.1 0.2 <0.1 Sebastes serranoides

--0.2 0.4 <0.1 0.2 <0.1 Brachyistius frenatus (juv.) --0.2 0.4 <0.1 Anarrhichthys ocellatus

<0.1 0.2 --<0.1 Sebastes paucispinis (juv.) <0.1 0.2 -<0.1 Cephaloscyllium ventriosum

--<0.1 0.2 <0.1 Sebastes melanops (juv.) <0.1 0.2 --<0.1 Sebastes chrysome/IS.

camatus (yoy) --<0.1 0.2 <0.1 0 ESLO2014-02 H-8