L-2013-087, Flood Hazard Reevaluation Report in Response to 50.54(f) Information Request Regarding Near-Term Task Force Recommendation 2.1. Part 2 of 2

From kanterella
(Redirected from L-2013-087)
Jump to navigation Jump to search
Flood Hazard Reevaluation Report in Response to 50.54(f) Information Request Regarding Near-Term Task Force Recommendation 2.1. Part 2 of 2
ML13095A197
Person / Time
Site: Turkey Point  
Issue date: 03/11/2013
From: Martinchich P
Enercon Services
To:
Office of Nuclear Reactor Regulation, Florida Power & Light Co
References
L-2013-087 FPL062-PR-001, Rev 0
Download: ML13095A197 (48)


Text

S...-

rv

-1 iAMRO MM2S 100 0 00 200 100 100,.

k~owTIRS LIP Ratios and Estimates for Durations Less Than 1-Hour Duration 5 Minutes 15 Minutes 30 Minutes Ratio to 1 Hour LIP 0.32 0.50 0.73 LIP 19.4 in. x 0.32 = 6.21 in.

19.4 in. x 0.50 = 9.70 in.

19.4 in. x 0.73 = 14.16 in.

Reference:

NOAA, 1982.

Legend:

Figure 4-1 Turkey Point Nuclear Generating Station Units 3&4 (PTN)

HMR52 hour 1-Square Mile PMP Document Name: FPL062-GIS-A015 Flooding Hazard Reevaluation By: MLS Date: 2/8/2013 Turkey Point Nuclear Generating Station Units 3&4 (PTN)

0 4.0 0.

E 20.0 18.0 16.0 14.0 12.0 10.0 8.0 6.0 4.0 19.4 inches 1-hour Cumulative Precipitation I

F KI~~¶3(

2.0 0.0 0

10 20 30 Time (minutes) 40 50 60 Figure 4-2 60 Minute Local Intense Precipitation (LIP) Curve Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Document Name: FPLO62-GIS-AO14 By: MLS Date: 2/8/2013

WJ U

0 4J C.

CI 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 j +/- 1III I I I I I

ll lll I

I II I I I I I I I I I I I I I I I I I~ I II lI I I I I I I I I I I I4 1 1 I I

-I--+ -

i i

i i

! i i i i i

! i F -+

I I

I II I I I II I

I I I I I I

I F I I

I I I I I I I I-I 44444H MLT ii ii L i

VViiWVVi V

iii Vi VV V i

i i ! i i i i i i i

! ! i

! i i i i i i i I

I 1 11 LL Incremental Precipitation at One Minute Intervals

! i i i i !

I i i i ! i i i i i ! i i

Il-I'll-I II in Muwi m

1 3 5

7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 Time (minutes)

Figure 4-3 Local Intense Precipitation (LIP) Distribution Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Document Name: FPL062-GIS-A014 By: MLS Date: 2/8/2013

Figure 4-4 Elevations Rendered on the Study Area Grid Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Document Name: FPL062-GIS-A015 By: MLS Date: 2/8/2013

Legend Points of Interest Manning's n

[*

Structures Feet 0

150 300 450 I

__ 1 I

I 0

40 80 120 160 Meters Document Name: FPLTP077-GIS-A021 Projection: State Plane Florida East, NAD 83 (US Feet)

By: MLS Date: 01/06/2013 0.02 0.025 0.08 0.10 o

0.12 Figure 4-5 Manning's n Value Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

00 Li 1:1 Refrences: 1. SFWMD, 2007a Legend

=I Structures Flow Depth (ft) -

0.6 0.7-0.8 0.9-1*0 1.1-1.2 1.3-1.4 1.5-1.6 1.7-1.8 S1.9 - 2.0 S2.1 - 2.5 S2.6 - 3.0 3.1 - 3.5 I

3.6 - 4.0 II4.1 - 5.0 S5.1 - 6.0 1

61 -70 Feet 0

250 500 750 I

I I

I 0

50 100 150 200 250 Meters Figure 4-6 Document Name: FPLTP077-GIS-AO12 Projection: State Plane Florida East, NAD 83 (US Feet)

By: MLS Date: 01/06/2013 Maximum Flow Depth (ft)

Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

References:

1. SFWMD, 2007a.

Legend Points of Interest Structures Flow Depth (ft) 1.1 - 1.2 1.9 - 2.0 3.6 - 4.0 06 13-14 21-25 4.41-50 0.7- 0.8 1.5-1.6 2.6-3.0 5.1-6.0 0.9-1.0

=

1.7-1.8 3.1-3.5 6.1-7.0 300 Feet 0

100 200 I

  • I I

I I

0 20 40 60 80 Meters Document Name: FPLTPO77-GIS-AO1 3 Projection: Station Plane Florida East, NAD 82 (US Feet)

By: MLS Date: 01/06/2013 Figure 4-7 Points of Interest Overlaid with the Maximum Flow Depth (ft)

Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Reference:

FPL. 2010.

Document Name: FPL062-GIS-A015 By: MLS Date: 2/8/2013 Figure 4-8 Points of Interest Overlaid with Main Plant Site Drawing Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

References:

1. SFWMD, 2007a Legend Points of Interest I--]Structures Velocity (ft/s) 0,601 - 0.800 1.501 - 1.750 3.001 - 3.500 0.000 - 0.200 0.801 - 1.000 1.751 - 2.000 3.501 - 4.500 0.201 - 0.400 1.001 - 1.250 2.001 - 2.500 4.501 - 6.000 0.401 - 0.600 1.251 - 1.500 2.501 - 3.000 6.001 - 7.460 Feet 0

100 200 300 I*

I I

I 0

24 48 72 96 Meters Document Name: FPLTP077-GIS-A027 Projection: Station Plane Florida East, NAD 82 (US Feet)

By: MLS Date: 01/06/2013 Figure 4-9 Points of Interest Overlaid with the Peak Flow Velocity (ft/s)

Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

  • 1~

/

10331'

'I, 7

II-K

~

I -~

I ~

OONDEI$ ER PIT i1 I I§kfl

=

I: ~

t

~i~I r--TT

.1

]OO -E &2 4-----

71

//

/

1 NDI-ŽýP 1 I1 h

~ L~!~'" -~

'4-I FT4."-

____~~~

-1 50oecFý l'~~mn4--

Co FLOR LW E

Reference:

FPL, 1999.

woo;

'~A~A Figure 4-10 Approximate Flood Protected Areas Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Document Name: FPL062-GIS-A014 By: MLS Date: 2/8/2013

0.5 0 i-i-FT1

-~

i2~K~L-i-L~iJ I ifi 4- {

I H

if I

1211'

_ I -~ --

t I

I

{ F--

- -t I

~

I 00 00

-0.5 Z

4-M

-1.5 o

7111Z7 IV'L 1 L

I

_7 janu~ar 20331~

W r

~

H

-V aru I

ff !~

I Ti I

L13 Tidal Data (Virginia Key, FL)

Linear Trend (Sea Level Rise)

L &I I

- s-i -

I i 200 400 600 800 1000 1200 1400 1600 Months (0 = Jan 1994)

References:

NOAA, 2012e.

Figure 4-12 Sea Level Rise - Linear Trend Document Name: FPL062-GIS-A014 By: MLS Date: 2/8/2013 Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

3.5 3

2.5 2

01.5 0

" -0.5 alJ

-1.5 S-2 cu05 I -%

i I

Tidal Data (Virginia Key, FL) 2nd Order Trend

___(Sea Level Rise) 1600

-I

=

)

200 400 600 800 1000 1200 Months (0 = Jan 1994) 1400

References:

NOAA, 2012e.

Figure 4-13 Sea Level Rise - 2nd Order Trend Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Document Name: FPL062-GIS-A014 By: MLS Date: 2/8/2013

Strom Tracks for CalibrationNalidation Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Miami Harbor Entrance IHO 1

DELFT3D Computed Tide Resynthesized Tide 0-5 Ci)

E a)

-0.51 III'

~IIIIII!.I I

-1 W

-1.5 1 Sep 15 Sep 29 Sep Time 13 Oct 27 Oct Figure 4-15 Tidal Station Calibration Results at IHO Station Miami Harbor Entrance, Florida Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Document Name: FPLO62-GIS-AO14 By: MLS Date: 2/8/2013

,=ll Legend Turkey Point Nuclear Generating Station Units 3 & 4 (PTN)

Hurricane Position (6 hr Time Step)

Hurricane Andrew (Calibration)

Hurricane Donna (Validation)

DELFT3D Grid Model L _ _ _ _ D o m a in

References:

1. ESRI, 2013a, 2. NOAA, 2012.a Miles 0

350 700 1,050 I

I I

I I

I I

I I

0 400 800 1,200 1,600 Kilometers Document Name: FPLTP077-GIS-AO07 Projection: Geographic Coordinate System, WGS 84 By: MLS Date: 01/06/2013 Figure 4-16 Strom Tracks for CalibrationNalidation Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Reference:

NOAA, 2012n.

Note: Reported values are in meters NGVD 29 datum.

Legend:

Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Figure 4-17 Observed Storm Surge Water Levels for Hurricane Andrew Document Name: FPL062-GIS-AO15 By: MLS Date: 2/8/2013 Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Water Level (meters in Mean Sea Level)

-ý3 25.65 -

25.6 -

25.55 I M

0 0

25.5 F Wind Vector PTN

-80.

-0r1Ck

-8.

-80.2

-80.15

-80.1 1.5 I

I 2

2.5 25.45 -

25.4 -

25.35 F 25.3 -

-80.5

-80.45

-80.4

-80.35

-80.3

-80.25 x coordinate --

Time Step 1 (Output Time Step 368 [August 24, 1992 @ 09:30:00])

Figure 4-18 DELFT3D Computed Hurricane Andrew Storm Surge at Time Step 1 in the Fine Grid 2 Model Domain Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Document Name: FPL062-GIS-AO14 By: MLS Date: 2/8/2013

Water Level (meters-in Me; ed) 4 25.65 -

Wind Vector PTN 25.6 F 3

25.55 F F 1 2

25.5

.' 25.45

=

=

1 Hurricane

ýt°*rr.ý T-rac 25.4 F 0

25.35 k

-1 25.3 F

-80.5

-80.45

-80.4

-80.35

-80.3

-80.25

-80.2

-80.15

-80.1 x coordinate --,

Time Step 2 (Output Time Step 369 [August 24, 1992 @ 10:00:00])

Figure 4-19 DELFT3D Computed Hurricane Andrew Storm Surge at Time Step 2 in the Fine Grid 2 Model Domain Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Document Name: FPLO62-GIS-AO14 By: MLS Date: 2/8/2013

Water Level (meters in Mean Sea Leve 1) 25.65 I 25.6 F 25.55 F T

25.5 0

S25.45

~Q\\\\\\ \\\\'~

t,.

Wind Vector PTN

ýrlc 7

Afler orn raCk edrW V 12 4

3 I

25.4 -

0

-1I 25.35 -

25.3

-80.5

-80.45

-80.4

-80.35

-80.3

-80.25

-80.2

-80.15

-80.1 x coordinate --+

-2 Time Step 3 (Output Time Step 370 [August 24, 1992 @ 10:30:00])

Figure 4-20 DELFT3D Computed Hurricane Andrew Storm Surge at Time Step 3 in the Fine Grid 2 Model Domain Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Document Name: FPL062-GIS-A014 By: MLS Date: 2/8/2013

Water Level (m in MSL)

Wind 25.*5 5 Vector 4

PTN 3.5 25.65 t 25.55 25.45 2.5 t' 25,5 2

-2

.0.

25.35 25.3 -

0.

-60.5

-80.45

-80.4

-80.35

-80.3

-80.25

-80.2

-80.15

-60.1 x coordinate -*

Time Step 1 (Output Time Step 8340 [September 10, 1960 @ 07:58:00])

Figure 4-21 DELFT3D Computed Hurricane Donna Storm Surge at Time Step I in the Fine Grid 2 Model Domain Document Name: FPL062-GIS-A014 By: MLS Date: 2/8/2013 Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Reference:

Harris, 1963.

Note: Reported values are in feet NGVD 29 datum.

Legend Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Figure 4-22 Observed Storm Surge Water Levels for Hurricane Donna Document Name: FPL062-GIS-A014 By: MLS Date: 2/8/2013 Flooding Hazard Reevaluation Turkey Point Nuclear. Generating Station Units 3&4 (PTN)

Reference:

NWS, 1979.

Legend:

Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Figure 4-23 Coastal Distance Intervals in Nautical Miles and Kilometers Document Name: FPL062-GIS-AO15 By: MLS Date: 2/8/2013 Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

0 0

0 0

0 In

'1 03 0

0 0

a o

0 01 ca co co 0

1 F-7.

0.

k ck

-ý M

EASTPORT, ME BOSTON. MASS -

b NEW YORK. NY -

b CHINCOTEAGUE.

VA -

CAPE HATTERAS, N C -O 0HAR.ESTON, S C DAYTONA BEACH. FLA --

MlAWE FLA FT MYERS. FL-A TARPON SPRINGS.

FLA --

APALACHKX1A. FLA---

PENSACOLA, FLA

SLOX, miss LAKE CHARLES, LA--)-

GALVESTON, TEX ------a PORT ISABEL. TEX S

1 1

1 1 1 1 I j ig

-4 a-2 cc a

I I 1i I

I 1 I

f 0

I 0

0

)

0

)

0 0

C 4 N

0 N

1 C 4 0

o K

N N

,0 0

a0

.0 V

4 N4 N4 N

(

(

N4 N4 In C4 (INDl 3W1SSId lSI+/-N33

Reference:

NWS, 1979.

Figure 4-24 Legend:

STurkey Point Nuclear Generating Station Units 3&4 (PTN)

Central Pressure for the Probable Maximum Hurricane (PMH)

Document Name: FPLO62-GIS-AO15 By: MLS Date: 2/8/2013 Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

MD) b, 0

0 o

0 0

0

4.

_Cv V4 EASTPORT, W------

BOSTON, MASS NEW YORK.

N.Y.-

C -INCOTEAGLE, VA.

CAPE HATTERAS, N.C.---)

CHARLESTON, S.C.--

DAYTONA BEACH. FLA. -.

MIAMI. FLA.

FT. MYERS.

FLA TARPON SPRINGS. FLA.--,

APALACHICOLA.

FLA.----.1 PENSACOLA. FLA.---

BILOXI. MISS.

LAKE CHARLES. LA.--i--

GALVESTON, TEX.

3-*

PORT ISABEL,. TEX.-" I I

I I

I I

I o

X 9

LU

-A CC 0~

x z

0 ao I

I I

' L-

' :it

. "ie

. 0 0*

C l

t4 WI C

(IW NJ scNim wflwixvw :50 smliG

Reference:

NWS, 1979.

Legend:

Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Document Name: FPLO62-GIS-AO15 By: MLS Date: 2/8/2013 Figure 4-25 Adopted Upper and Lower Limits of Radius of Maximum Winds for the Probable Maximum Hurricane (PMH)

Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

() I H/W)t I o

a

'l 0

I -

I -

~ -

I -

I -

- -5 EASTPORT.

kE.-

BOSTONK MASS-NEW YORK.

N.Y.-

c.NcEAGU*, VA.---.-

CAPE HATTERAS, N.O.-.

CHARLESTON, S.C.--

DAYTONA BEAC*., FLA. -*

MIAMa FU.L FT. MYERS& FLA.-

TARPON SPRINS, FLAr.-B APALACHICOLA. FLA.--N PENSACOLA.

FLA.------*-

SLOX. MSS.---

LAKE CHARLES, LA.----*

GALVESTON, TEX.--

AORT ISASEL. TEX.--

I 11 I1 1 11 1 11 1 I

5 l-I

~~10 Ii z

2 Z

~I iii I

1I1 I

il II h~ ~~ ~~~~~~~

i

ý-

I I-1 0

40 0

WII Gaads QOUVM8O0i 0

Reference:

NWS, 1979.

Legend:

Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Document Name: FPL062-GIS-AO15 By: MLS Date: 2/8/2013 Figure 4-26 Adopted Probable Maximum Hurricane (PMH)

Upper and Lower Limits of Forward Speed Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

(156P) N01l133NlU

)DYV~i

Reference:

NWS, 1979.

Legend:

Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Figure 4-27 Maximum Allowable Range of the Probable Maximum Hurricane Track Direction Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Document Name: FPLO62-GIS-A015 By: MLS Date: 2/8/2013

Legend Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Hurricane Storm Classification (Saffir-Simpson Hurricane Scale) 0- Category 4 Miles 0

40 80 120 I -- -

- -4I I

  • I I

I I

0 50 100 150 200 Kilometers Figure 4-28 Tracks of Historical Hurricanes (Intensities of Category 4 & 5) in the Region of PTN Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

w. Categroy 5 Document Name: FPLTP077-GIS-A016 Projection: Geographic Coordinate System, WGS 84 By: MLS Date: 01(0612013

Legend Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Miles 0

20 40 60 I _

I_

I I

I 0

20 40 60 80 100 Kilometers Synthetic Storm Tracks for Probable Maximum Storm Surge Analyses Figure 4-29 Document Name: FPLTP077-GIS-A017 Projection: Geographic Coordinate System, WGS 84 By: MLS Date: 01/06/2013 Synthetic Storm Tracks Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

CO Go CLi

-4 4-0 RADIUS OF MAXIMUM WINDS (nmi)

Reference:

NWS, 1987.

Figure 4-30 Plot Central Pressure (P0) Versus Radius of Maximum Winds (R) for Extreme Hurricanes Document Name: FPL062-GIS-A015 By: MLS Date: 2/8/2013 Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

935 930 925 920 915 910 Ln u.j

-905 900 895 890 885 880 0

5 10 15 20 25 30 RADIUS OF MAXIMUM WINDS (NAUTICAL MILES) 35 40 45 Figure 4-31

Reference:

For storms through 1985 see NWS, 1979; For storms since 1985 see Table 4-15.

Document Name: FPL062-GIS-AO15 By: MLS Date: 3/8/2013 Plot Central Pressure (P0) Versus Radius of Maximum Winds (R) for Extreme Hurricanes, Revised 2013 Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

N S

IA'A A

1040 L

Iii

-4 I'A 1020 7TLI i9 9600 98 0

1 O

860

-1 42 1-~ti

~

Radial Distance from Storm Center (nautical miles)

Figure 4-32 Document Name: FPLTPO77-GIS-A026 Hurricane Pressure Field Projection: State Plane Florida East, NAD 83 (US Feet)

Flooding Hazard Reevaluation By: MLS Date: 01/6/2013 Turkey Point Nuclear Generating Station Units 3&4 (PTN)

A 3/4 3/4 I,

4 d

444

'S 4

S J 4 S 4 I 4~

44 3/4, 3/4, i

d i

'I 1,

//

d/

/

1/

//

'/

17

'Ii,'

'I

/

~1 //

/ //

7

.~

'~t

'-S

~ '

'-5-'.

I'

~V ~

N S

S S 3/4 a

' t t Nautical Miles 0

50 100 I

7 I

A

_£I__

r l A' A

I I

'S

'S

'S I

I N"

\\

1.

">-I II;,

A 140 120 100 80 0

C4

  • 0 0.

S40 20 0

-300

-250

-200

-150

-100

-50 0

50 100 150 200 250 300 Radius from Storm Center (nautical miles)

Figure 4-33 Document Name: FPLTPO77-GIS-A028 Projection: State Plane Florida East, NAD 63 (US Feet)

By: MLS Date: 01/6/2013 Wind Field and Wind Speed Plots Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

9000 92000 W+

EI 1'S 6.28 ft NAVDB8 7.93 ft MLW 1ft NAVD88 Ift MLW NAVD88 MLW I

5.86 7.51 7.68 ft 9.33 ft!

Legend Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Spot Elevation Miami-Dade Co.

DEM (ft NAVD88)

High : 168.113 Low: -18.186 Florida Keys DEM (ft NAVD88)

High: 93.9108 Low: -18.186 Miles 0

1 2

3 t _

_ I I

I I- - I I

I I

0 1

2 3

4 5

Kilometers Figure 4-34 Document Name: FPLTP077-GIS-A024 Projection: State Plane Florida East, NAD 83 (US Feet)

Vertical Datum: NAVD88 By: MLS Date: 01/06/2013 Barrier Island Breakwater Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

1U

.21 V-mI-ZI 11[

II 876B00 Reterences: 1.

Legend Turkey Point Nuclear Generating Station Units 3 & 4 (PTN) l Station (feet)

Cross Section Feet 0

100 200 300 I

I 0

24 48 72 96 Meters Figure 4-35 Relationship of Breakwater to Power Block Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Document Name: FPLTP077-GIS-A025 Projection: State Plant Florida East, NAD 83 ( US feet)

By: MLS Date: 01/06/2013

Direction of Wave Propagation M

Maximum Sustainable Wave Height or Breaking Wave Heigh t (Hb)

Significant Wave Height (H.)

Large Waves Break at the Breakwater Breakwater Note: Not to Scale Figure 4-36 Maximum Wave Height Over the Breakwater Structure Document Name: FPLO62-GIS-AD14 By: MLS Date: 2/8/2013

. Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Cross Section 1 33 28 23 O18 4L

  • ~13

.2~

8 3

PTN FLOOR ELEVATION

_Area Assumed Flat Water f*

~Surface

-__._ _Elevation of I

the Cooling Water Canal

-Ground Surface (feet-NAVD88)

-2 0

100 200 300 400 500 600 700 800 900 1000 1100 Distance along the Cross Section (feet)

Figure 4-37

Reference:

Ford, 2012a.

Document Name: FPL062-GIS-A014 By: MLS Date: 2/8/2013 Representative Cross Section for Wave Analysis Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

75"1 W70W 851N 4"t 351ý 30*N WN1 Quatemary rivers Thick Quatemnay shelf-edge deposits Study area Turkey point Nuclear Generating Station Units 3&4 0 100200 300 400 500 70"W es'*

References:

Atlantic and Gulf of Mexico Tsunami Hazard Assessment Group, 2008 Figure 4-38 Location Map Showing the Extent of the AGMTHAG Study Area and Geologic Features That May Influence Landslide Distribution along the U.S. Atlantic Margin Document Name: FPL062-GIS-A020 Flooding Hazard Reevaluation By: MLS Date: 2/8/2013 Turkey Point Nuclear Generating Station Units 3&4 (PTN)

35°N-

,40"N Sediment age from cores Pleistocene 2

Pliocene A

Miocene cuffiluck Eocene 3$14 Landslide types Debris flow Rotational slide C LoTranslational slide l

Composite landslide 0

100 200 300 400 500 KFometers 75W 70w awSW Note: HC = Hudson Canyon; LC = Lindenkohl Canyon; WC = Wilmington Canyon; NC = Norfolk Canyon.

References:

Atlantic and Gulf of Mexico Tsunami Hazard Assessment Group, 2008 Figure 4-39 Distribution of Different Landslide Types Along the U.S. Atlantic Margin Document Name: FPL062-GIS-A020 By: MLS Date: 2/8/2013 Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

95*W Bs901 Bo6 asw 30"-

-30"N 25N.

-14" Provinces salt ZiCarrofa 20 Landslides 20N Carbonate debris flow deposi"ts Carborateo ta.* depos*s Temrgenous mass-wastin deposits 00"W 90W 85"W Figure 4-40 Location Map Showing the Size, Distribution, and Composition of Landslides in the Gulf of Mexico

References:

Atlantic and Gulf of Mexico Tsunami Hazard Assessment Group, 2008 Document Name: FPL062-GIS-A019 Flooding Hazard Reevaluation By: MLS Date: 2/8/2013 Turkey Point Nuclear Generating Station Units 3&4 (PTN)

35N Note: Barbed lines - proposed faults by previous studies: GBF - Gorringe Bank Fault; MPF - Marquds de Pombal Fault; SVF-St. Vincente Fault; HSF - Horseshoe Fault; GCF - Gulf of Cddiz Fault. PIAB refers to the Paleo Iberia-Africa Plate Boundary.

Depth contours are in meters (only contours from -250 to -2000 meters are shown.

Inset Plates: NAM - North American Plate; EUR - Eurasia Plate; AFR - African Plate.

References:

Atlantic and Gulf of Mexico Tsunami Hazard Assessment Group, 2008 Figure 4-41 Plate Tectonic Setting and Bathymetry of the Eastern Azores-Gibraltar Region Document Name: FPL062-GIS-A020 By: MLS Date: 2/8/2013 Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

in~

1 OVI 0000 M70 0000 4000 4000 -W00 -M00 -I=0 Depth (meters)

Note: Red lines are plate boundaries and red arrows indicate plate movement.

Figure 4-42 The Caribbean Plate Boundary and its Tectonic Elements Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

References:

Atlantic and Gulf of Mexico Tsunami Hazard Assessment Group, 2008 Document Name: FPL062-GIS-AO19 By: MLS Date: 2/8/2013

-j CA E

4-,

.4-4.,

4.0 1.5 3.0-2.5 2.0 1.5 5

1.0

____0

-0.--

-2.0

-1.5 0:00 0

2 3

4 5

6 7

8 9

.09:

010.

1 My 17 17 Hours into Model Simulation 23:1 16-05-2

30:00 2010 Figure 4-43 Simulated Tsunami Marigram Near PTN (with Manning's n of 0.02 and non-reflective boundaries)

Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

References:

NEE, 2012.

Document Name: FPL062-GIS-A020 By: MLS Date: 2/8/2013

-20 0

40 60 80 m

I lhr-. 20id/05/i 7 04130,00 f

AI" 40 4

o30k-20i1-30 20 10 10 0

0

-10o--

-20

-10

-20

-30

-40

-30[-

-A

-20 0

20

References:

NEE, 2012.

  • U OU km 0<-3.0 0<D.5 M<2.5 I<4.5 M <-2.0 0<1.0
  • <3.0
  • '<.0 0<-1.0 l<1.5 4i1.5 N-.5 0 <0.0 EI <2.0
  • <4.0
  • )>5.5 Turkey Point Nuclear Generating Station Units 3&4 Note: Water levels are in meters relative to 1.36 m MSL; some (dry) land elevations are shown as flood water levels according to designation in Delft3D-FLOW Manning's n of 0.02 and non-reflective boundaries Figure 4-44 Tsunami Water Level Contours near PTN 4.5 Hours in the Model Simulation Corresponding to the Time Close to the Maximum Water Level at Site Document Name: FPL062-GIS-A020 Flooding Hazard Reevaluation By: MLS Date: 2/8/2013 Turkey Point Nuclear Generating Station Units 3&4 (PTN)

Figure 4-45

Reference:

NEE, 2012 Document Name: FPL062-GIS-A015 By: MLS Date: 2/8/2013 Meteorological and USGS Stations Near PTN Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

( U C-65 E

I-'-60 0

Date Figure 4-46 Water Temperatures at the USGS Stations Near PTN

Reference:

NEE, 2012.

Document Name: FPLO62-GIS-A014 By: MLS Date: 2/8/2013 Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN) 1*

mmsr.~S 3I.

romi. maw. 4. or vvmu. moua. g. Nat,~

/v iz.

41. INut"~. 2UI I

Legend Historic Shoreline Turkey Point 1928 Nuclear Generating 1946 Station Units 3&4 (PTN) 197111972 Feet 0

600 1,200 1,800 I_

I I

I I

l I

I I

0 150 300 450 600 Meters Figure 4-47 Docuiment Name: FPLTP077-GIS-A023 Projection: State Plane Florida East, NAD 83 (US Feet)

By: MLS Date: 01/6/2013 Historic Shoreline Changes at PTN Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)

20.0-19.0-

  • '18.0~

z W 17.0 w

U-LL Z0z_

/ --

TOTAL PRESSURE 4

-~

HYDRODYNAMIC UJw..

HYDROSTATIC I

I I

I I

I I

I I

I I

25 50 75 100 125 150 175 200 225 250 275 300 PRESSURE (Ib/ft2)

Figure 4-48 Hydrostatic and Hydrodynamic Pressure Document Name: FPL062-GIS-AO15 By: MLS Date: 3/8/2013 Flooding Hazard Reevaluation Turkey Point Nuclear Generating Station Units 3&4 (PTN)