Category:Letter type:L
MONTHYEARL-2024-010, Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3)2024-01-25025 January 2024 Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2024-004, Relief Request (RR) 7, Proposed Alternative in Accordance with 10 CFR 50.55a(z)(1) Extension of Inspection Interval for Reactor Pressure Vessel Welds from 10 to 20 Years2024-01-18018 January 2024 Relief Request (RR) 7, Proposed Alternative in Accordance with 10 CFR 50.55a(z)(1) Extension of Inspection Interval for Reactor Pressure Vessel Welds from 10 to 20 Years L-2024-002, Withdrawal of Proposed Alternative to American Society of Mechanical Engineers (ASME) Operation and Maintenance (OM) Code for the Auxiliary Feedwater (AFW) 2C Pump2024-01-0808 January 2024 Withdrawal of Proposed Alternative to American Society of Mechanical Engineers (ASME) Operation and Maintenance (OM) Code for the Auxiliary Feedwater (AFW) 2C Pump L-2023-173, Quality Assurance Topical Report (FPL-1) Revision 30 Update2023-12-15015 December 2023 Quality Assurance Topical Report (FPL-1) Revision 30 Update L-2023-179, Unusual or Important Environmental Event - Turtle Mortality2023-12-14014 December 2023 Unusual or Important Environmental Event - Turtle Mortality L-2023-168, License Amendment Request Supplement to Revision 2 for the Technical Specifications Conversion to NUREG-1432 Revision 52023-12-12012 December 2023 License Amendment Request Supplement to Revision 2 for the Technical Specifications Conversion to NUREG-1432 Revision 5 L-2023-155, Supplement to Response to Request for Additional Information, Revised NextEra Common Emergency Plan, and Revised Site-Specific Emergency Plan Annexes Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-06542023-11-28028 November 2023 Supplement to Response to Request for Additional Information, Revised NextEra Common Emergency Plan, and Revised Site-Specific Emergency Plan Annexes Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, L-2023-162, Response to 50.69 2nd Round of Rals2023-11-21021 November 2023 Response to 50.69 2nd Round of Rals L-2023-131, Subsequent License Renewal Application - Second Annual Update2023-09-28028 September 2023 Subsequent License Renewal Application - Second Annual Update L-2023-136, Supplement to License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors2023-09-26026 September 2023 Supplement to License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors L-2023-122, Corrections to the 2022 Annual Radiological Environmental Operating Report2023-09-20020 September 2023 Corrections to the 2022 Annual Radiological Environmental Operating Report L-2023-127, Correction to the 2022 Annual Radioactive Effluent Release Report2023-09-18018 September 2023 Correction to the 2022 Annual Radioactive Effluent Release Report L-2023-113, Correction to the 2020 Annual Radiological Environmental Operating Report2023-09-14014 September 2023 Correction to the 2020 Annual Radiological Environmental Operating Report L-2023-118, Response to Request for Additional Information Regarding License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors2023-09-11011 September 2023 Response to Request for Additional Information Regarding License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors L-2023-108, Report of 10 CFR 50.59 Plant Changes2023-09-11011 September 2023 Report of 10 CFR 50.59 Plant Changes L-2023-112, Corrections to the 2021 Annual Radioactive Effluent Release Report2023-09-0606 September 2023 Corrections to the 2021 Annual Radioactive Effluent Release Report L-2023-107, Technical Specification Bases Control Program Periodic Report of Bases Changes TS 6.8.4.j.42023-09-0606 September 2023 Technical Specification Bases Control Program Periodic Report of Bases Changes TS 6.8.4.j.4 L-2023-114, Proposed Turkey Point Units 6 and 7; Seabrook Station; Point Beach Units 1 and 2 - Official Service List Update2023-08-17017 August 2023 Proposed Turkey Point Units 6 and 7; Seabrook Station; Point Beach Units 1 and 2 - Official Service List Update L-2023-098, and Point Beach Units 1 and 2 - Response to Request for Additional Information Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 22023-08-0707 August 2023 and Point Beach Units 1 and 2 - Response to Request for Additional Information Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 2 L-2023-105, Preparation and Scheduling of Operator Licensing Examinations2023-08-0303 August 2023 Preparation and Scheduling of Operator Licensing Examinations L-2023-099, Pump Relief Request 10 (PR-10), One-Time Request for an Alternative to the American Society of Mechanical Engineers (ASME) Operation and Maintenance (OM) Code for the Auxiliary Feedwater (AFW) 2C Pump2023-07-26026 July 2023 Pump Relief Request 10 (PR-10), One-Time Request for an Alternative to the American Society of Mechanical Engineers (ASME) Operation and Maintenance (OM) Code for the Auxiliary Feedwater (AFW) 2C Pump L-2023-102, Relief Request PSL2-15-RR-01, Proposed Alternative to ASME Section XI Code Examination Requirements for Reactor Vessel Bottom Area and Piping in Covered Trenches2023-07-26026 July 2023 Relief Request PSL2-15-RR-01, Proposed Alternative to ASME Section XI Code Examination Requirements for Reactor Vessel Bottom Area and Piping in Covered Trenches L-2023-097, Subsequent License Renewal Application Revision 1 - Supplement 62023-07-13013 July 2023 Subsequent License Renewal Application Revision 1 - Supplement 6 L-2023-076, In-Service Inspection Program Owner'S Activity Report (OAR-1)2023-07-11011 July 2023 In-Service Inspection Program Owner'S Activity Report (OAR-1) L-2023-087, Florida Power & Light/Nextera Energy, Results of the Safety Culture Program Effectiveness Review, March 20, 2023 (ADAMS Accession No. ML22340A452)2023-06-29029 June 2023 Florida Power & Light/Nextera Energy, Results of the Safety Culture Program Effectiveness Review, March 20, 2023 (ADAMS Accession No. ML22340A452) L-2023-082, Subsequent License Renewal Application Revision 1, Supplement 52023-06-14014 June 2023 Subsequent License Renewal Application Revision 1, Supplement 5 L-2023-074, Addendum to 2021 Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation Ctsfsi) Financial Assurance Update2023-06-0202 June 2023 Addendum to 2021 Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation Ctsfsi) Financial Assurance Update L-2023-071, NextEra Energy Quality Assurance Topical Report (FPL-1) Revision 29 and Florida Power and Light Company Quality Assurance Program Description for 10 CFR Part 52 Licenses (FPL-2) Revision 11, Annual Submittal2023-05-22022 May 2023 NextEra Energy Quality Assurance Topical Report (FPL-1) Revision 29 and Florida Power and Light Company Quality Assurance Program Description for 10 CFR Part 52 Licenses (FPL-2) Revision 11, Annual Submittal L-2023-059, Subsequent License Renewal Application - Aging Management Requests for Additional Information (RAI) Set 4 Supplemental Response2023-04-21021 April 2023 Subsequent License Renewal Application - Aging Management Requests for Additional Information (RAI) Set 4 Supplemental Response L-2023-055, 2022 Annual Environmental Operating Report2023-04-12012 April 2023 2022 Annual Environmental Operating Report L-2023-041, Annual Radiological Environmental Operating Report for Calendar Year 20222023-04-0404 April 2023 Annual Radiological Environmental Operating Report for Calendar Year 2022 L-2023-051, Report of 10 CFR 50.59 Plant Changes2023-04-0404 April 2023 Report of 10 CFR 50.59 Plant Changes L-2023-021, Units, 1 and 2, Turkey Point, Units 3 and 4, Seabrook Station and Point Beach, Units 1 and 2 - Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation (ISFSI) Financial Assurance Update2023-03-28028 March 2023 Units, 1 and 2, Turkey Point, Units 3 and 4, Seabrook Station and Point Beach, Units 1 and 2 - Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation (ISFSI) Financial Assurance Update L-2023-042, Periodic Update of Population Data within 10 and 50 Miles of the Plant2023-03-27027 March 2023 Periodic Update of Population Data within 10 and 50 Miles of the Plant L-2023-026, Subsequent License Renewal Application - Aging Management Requests for Additional Information Set 42023-03-27027 March 2023 Subsequent License Renewal Application - Aging Management Requests for Additional Information Set 4 L-2023-028, and Point Beach Units 1 and 2, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications2023-03-27027 March 2023 and Point Beach Units 1 and 2, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications L-2023-025, Fleet Relief Request (Frr) 23-01, Proposed Alternative to ASME Section XI Authorizing Implementation of ASME Code Case N-752-12023-03-15015 March 2023 Fleet Relief Request (Frr) 23-01, Proposed Alternative to ASME Section XI Authorizing Implementation of ASME Code Case N-752-1 L-2023-029, and Point Beach Units 1 and 2 Nuclear Property Insurance - 10 CFR 50.54(w)(3)2023-03-10010 March 2023 and Point Beach Units 1 and 2 Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2023-039, Cycle 27 Core Operating Limits Report2023-03-0707 March 2023 Cycle 27 Core Operating Limits Report L-2023-032, 2022 Annual Radioactive Effluent Release Report2023-02-28028 February 2023 2022 Annual Radioactive Effluent Release Report L-2023-038, 2022 Annual Operating Report2023-02-28028 February 2023 2022 Annual Operating Report L-2023-016, Radiological Emergency Plan - Revision 74 Report of Changes to Emergency Plan2023-02-15015 February 2023 Radiological Emergency Plan - Revision 74 Report of Changes to Emergency Plan L-2023-019, Annual Summary of Commitment Changes Implemented Without Prior NRC Notification for Calendar Year 20222023-02-15015 February 2023 Annual Summary of Commitment Changes Implemented Without Prior NRC Notification for Calendar Year 2022 L-2023-009, Owner'S Activity Report2023-01-31031 January 2023 Owner'S Activity Report L-2022-188, Unusual or Important Environmental Event - Turtle Mortality2022-12-19019 December 2022 Unusual or Important Environmental Event - Turtle Mortality L-2022-185, Turkey Points, Units 3 & 4; Seabrook Station; and Point Beach, Units 1 and 2 - Supplement to License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 22022-12-0909 December 2022 Turkey Points, Units 3 & 4; Seabrook Station; and Point Beach, Units 1 and 2 - Supplement to License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 2 L-2022-175, Application to Adopt 10 CPR 50.69, 'Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors2022-12-0202 December 2022 Application to Adopt 10 CPR 50.69, 'Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors L-2022-180, CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums2022-11-0909 November 2022 CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums L-2022-165, Subsequent License Renewal Application - Aging Management Request for Additional Information (RAI) 4.3.1-1a(second Round) - Class 1 Fatigue Response2022-10-26026 October 2022 Subsequent License Renewal Application - Aging Management Request for Additional Information (RAI) 4.3.1-1a(second Round) - Class 1 Fatigue Response L-2022-160, Station,, Point Beach Units 1 and 2, License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 22022-10-0404 October 2022 Station,, Point Beach Units 1 and 2, License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 2 2024-01-08
[Table view] |
Text
0 Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 FPL July 8, 2011 L-201 1-255 10 CFR 50.90 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Re: St. Lucie Plant Unit 1 Docket No. 50-335 Renewed Facility Operating License No. DPR-67 Response to NRC Vessels & Internals Integrity Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request
References:
(1) R. L. Anderson (FPL) to U.S. Nuclear Regulatory Commission (L-2010-259),
"License Amendment Request for Extended Power Uprate," November 22, 2010, Accession No. ML103560419.
(2) Email from T. Orf (NRC) to C. Wasik (FPL), "St. Lucie Plant Unit 1 EPU -
Request for additional information (Reactor Vessel and Internals)," June 14, 2011, Accession No. ML111650362.
(3) U.S. Nuclear Regulatory Commission (R.A. Nelson) letter to Electric Power Research Institute (N. Wilmhurst), "Final Safety Evaluation of EPRI report, Materials Reliability Program Report 1016596 (MRP-227), Revision 0,
'Pressurized Water Reactor (PWR) Internals Inspection and Evaluation Guidelines' (TAC No. ME0680)," June 22, 2011, Accession No. ML11600498.
By letter L-2010-259 dated November 22, 2010 [Reference 1], Florida Power & Light Company (FPL) requested to amend Renewed Facility Operating License No. DPR-67 and revise the St. Lucie Unit 1 Technical Specifications (TS). The proposed amendment will increase the unit's licensed core thermal power level from 2700 megawatts thermal (MWt) to 3020 MWt and revise the Renewed Facility Operating License and TS to support operation at this increased core thermal power level. This represents an approximate increase of 11.85% and is therefore considered an extended power uprate (EPU).
By Email from the NRC Project Manager dated June 14, 2011 [Reference 2], additional information related to the proposed EPU was requested by the NRC staff in the Vessels
& Internals Integrity Branch (CVIB) to support their review of the EPU LAR. The request for additional information (RAI) identified two questions. The response to these RAIs is provided in Attachment 1 to this letter.
This RAI response includes a revision to current commitments associated with the aging management of the reactor vessel and internals (RVI) components during the period of extended operation. The RVI Inspection Program (currently listed in Section 18.1.4 of an FPL Group company
St. Lucie Unit 1 L-2011-255 Docket No. 50-335 Page 2 of 2 the St. Lucie Unit 1 Updated Final Safety Analysis Report) was based on industry knowledge available at the time the license for St. Lucie Unit 1 was renewed. Since that time, industry-led efforts have been in progress by the Electric Power Research Institute (EPRI) Materials Reliability Program (MRP) Reactor Internals Issues Task Group (RI-ITG) and later by the MRP Reactor Internals Focus Group (RI-FG). The EPRI MRP RI-FG developed MRP-227, "Pressurized Water Reactor Internals Inspection and Evaluation Guidelines," (MRP-227, Revision 0). MRP-227, Revision 0 was approved by the NRC staff on June 22, 2011 (ML111600498) [Reference 3].
In Reference 3, the NRC requested that EPRI publish an accepted version of MRP-227 to include a "-A" (designating accepted). FPL commits to adopting MRP-227-A in place of the existing RVI Inspection program. This commitment applies to St. Lucie Unit 1 and is independent of the EPU LAR currently under staff review.
In accordance with 10 CFR 50.91(b)(1), a copy of this letter is being forwarded to the designated State of Florida official.
This submittal does not alter the significant hazards consideration or environmental assessment previously submitted by FPL letter L-2010-259 [Reference 1].
Should you have any questions regarding this submittal, please contact Mr. Christopher Wasik, St. Lucie Extended Power Uprate LAR Project Manager, at 772-429-7138.
I declare under penalty of perjury that the foregoing is true and correct to the best of my knowledge.
Executed on 7& - J'. - Zo,(I Very truly yours, Site Vice President St. Lucie Plant Attachment cc: Mr. William Passetti, Florida Department of Health
St. Lucie Unit 1 L-2011-255 Docket No. 50-355 Attachment 1 Page 1 of 3 Response to Request for Additional Information The following information is provided by Florida Power & Light Company (FPL) in response to the U. S. Nuclear Regulatory Commission's (NRC) Request for Additional Information (RAI).
This information was requested to support Extended Power Uprate (EPU) License Amendment Request (LAR) for St. Lucie Nuclear Plant Unit 1 that was submitted to the NRC by FPL via letter (L-2010-259) dated November 22, 2010, Accession Number ML103560419.
In an Email dated June 14, 2011 from NRC (Tracy Orf) to FPL (Chris Wasik), Accession Number ML111650362,
Subject:
St. Lucie Unit 1 EPU - request for additional information (Balance of Plant), the NRC requested additional information regarding FPL's request to implement the EPU. The RAI consisted of two (2) questions from the NRC's Vessels and Internals Integrity Branch (CVIB). Clarification of the two RAIs was provided in another Email dated June 14, 2011 from NRC (Tracy Orf) to FPL (Chris Wasik). The RAI questions and the FPL responses are documented below.
CVIB-7 RAI CVIB-5 (Ref. 1) part "a" requested the licensee to describe the method of determining if additional RVI components become susceptible to the aging effects of 1) cracking due to stress corrosion cracking or irradiation assisted stress corrosion cracking (IASCC), 2) reduction of fracture toughness due to irradiation embrittlement; 3) loss of material due to wear; 4) loss of mechanical closure integrity due to IASCC, irradiation embrittlement, irradiation creep, or stress relaxation; 5) loss of preload due to stress relaxation; and 6) dimensional change due to void swelling. RAI CVIB-5 part "c" requested the licensee clarify whether any additional reactor vessel internals components were determined to be susceptible to the aging effects listed in part "a" of the question as a result of extended power uprate (EPU), compared to those listed as susceptible to these mechanisms in the license renewal application.
The response to RAI CVIB-5 indicates that it was determined that certain components may be susceptible to additional degradation mechanisms, compared to the degradation mechanisms identified in the St. Lucie, Units I and 2 License Renewal Application (LRA) for those components, under EPU conditions. Specifically, the fuel alignment plate, control element assembly shroud assemblies, and the upper guide structure support plate may be susceptible to irradiation embrittlement. Cracking of these components was previously identified in the LRA. The licensee stated that the license renewal documentation would be updated to reflect this change. However, the response does not indicate specifically which aging management programs AMP(s) will manage the additional aging effects or whether changes to the existing identified AMPs will be necessary. The staff therefore requests the following information:
a) Identify the AMP(s) that will manage aging effects associated with additional aging mechanisms that will affect certain components as a result of EPU.
b) Discuss the adequacy of the existing AMPs to manage the aging effects associated with the additional aging mechanisms, and describe any changes that are necessary to the existing identified AMPs.
St. Lucie Unit 1 L-2011-255 Docket No. 50-355 Attachment 1 Page 2 of 3
Response
a) The additional reactor vessel internals (RVI) components determined to be susceptible to age related degradation resulting from EPU will be included in the St. Lucie Reactor Vessel Internals Inspection Program.
b) FPL plans to revise the Reactor Vessel Internals Inspection Program to align with MRP-227-A, "Materials Reliability Program: Pressurized Water Reactor Internals Inspection and Evaluation Guidelines." The adequacy of MRP-227-A for management of aging effects associated with the reactor vessel internals has been evaluated by the NRC as documented in Final Safety Evaluation of EPRI Report, Materials Reliability Program 1016596 (MRP-227), Revision 0, "Pressurized Water Reactor (PWR) Internals Inspection and Evaluation Guidelines" (TAC No. ME0680), dated June 22, 2011. Additionally, FPL has evaluated the changes in operating parameters associated with EPU and determined that they do not challenge the bounding assumptions of MRP-227-A.
CVIB-8 NUREG-1779 (Ref. 2) documents the following commitments related to aging management of the St. Lucie, Units I and 2 RVI components:
UFSAR Supplement Implementation Commitment Location SceueSource (LRA Appendix All)
Submit a report 18.1.4, Reactor Prior to the end LRA Appendix B, summarizing the Vessel Internals of the initial Subsection 3.1.4 aging effects Inspection Program operating Response to applicable to reactor license term. RAI 3.1-1 vessel internals (FPL letter including a L-2002-157) description of the inspection plan.
Perform a one-time 18.1.4, Reactor During the LRA Appendix B, inspection of the Vessel Internals period of Subsection 3.1.4 reactor vessel Inspection Program extended internals. operation.
Although Florida Power & Light Company (FPL) committed to submit an RVI component inspection program for St. Lucie, Units 1 and 2 prior to the period of extended operation, FPL did not specifically commit to submit an RVI component inspection program conforming to the industry's standard program. Therefore, the staff requests the licensee discuss their plans to implement the industry's recommended inspection and evaluation guidelines for RVI components as documented in topical report MRP-227, Rev. 0, as modified by the staff's SE expected to be issued during June 2011, or the approved version of the topical report (MRP-227-A), for Saint Lucie, Unit 1.
St. Lucie Unit 1 L-2011-255 Docket No. 50-355 Attachment 1 Page 3 of 3
Response
FPL hereby revises its current commitments associated with the aging management of the reactor vessel internals components during the period of extended operation to adopt MRP-227-A in place of the existing Reactor Vessel Internals Inspection Program.
NRC References
- 1. Letter from Tracy J. Orf to Mano Nazar dated April 19, 2011;
Subject:
St. Lucie Plant, Unit 1 - Request For Additional Information Regarding License Amendment Request For Extended Power Uprate (TAC NO. ME5091) (ADAMS Accession No. ML111010098).
- 2. NUREG-1 779, Safety Evaluation Report Related to the License Renewal of St. Lucie Nuclear Plant, Units 1 and 2, Docket Nos. 50-335 and 50-389, Florida Power & Light Company, September, 2003 (ADAMS Accession No. ML032940205).