JAFP-88-0739, Monthly Operating Rept for Jul 1988 for Ja Fitzpatrick
| ML20151S371 | |
| Person / Time | |
|---|---|
| Site: | FitzPatrick |
| Issue date: | 07/31/1988 |
| From: | Radford Converse, Jackie Cook POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK |
| To: | NRC, NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM) |
| References | |
| JAFP-88-0739, JAFP-88-739, NUDOCS 8808150175 | |
| Download: ML20151S371 (6) | |
Text
-. _ _ _ _ _ __
,, L' DOCKET 10: 50-333 UNIT NAME FITZPATRICK DATE August, 1988 COIPIETED BY JOHN COOK TELEPHONE (315) 349-6569 OP'NATING STATUS -
1.
UNIT NAME:
FITZPATRICK IUTES 2.
REPORTING PERIOD: 880701 - 880731
- 3. --
LICENSED THERMAL POWER (FWT):
2436 4.
NAMEPLATE RATING (GROSS SE):
883 5.-
DESIGN ELECTRICAL RATING (NET &E):
816 6.
MAXIMUM DEPENDABLE CAPACITY (GROSS WE):
805 7.
MAXIMUM DEPENDABLE CAPACITY (NET NE):
778 8.
IF CHANGES OCCUR IN CAPACI1Y RATINGS (ITa s 3 - 7) SINCE LAST REPORT, GIVE REASONS:
9.
POWER LEVEL 10 MIICH RESTRICTED, IF ANY (NET 144E):
10.
REASONS FOR RESTRICTIONS, IF ANY:
THIS FDNTH YR-10-DATE CUMULATIVE 11.
HOURS IN REPORTING PERIOD.
744 5111 114072 12.
NUMBER OF 110URS REACIOR WAS CRITICAL.
744 4729.3 84382 13.
REACIOR RESERVE SHbTDOWN H0URS.
0 0
0 14.
HOURS GENERATOR ON-LINE.
744 4689.9 82043 15.
UNIT RESERVE SHUIDOWN HOURS.
0 0
0 16.
GROSS THERMAL ENERGY GENERATED (& H).
1720584 11173488 178400764 17.
GROSS ELECIRICAL ENERGY GENERATED (FMI).
571550 3804950 60974190 18.
NET ELECIRICAL ENERGY GENERATED (&M).
552115 3672240 58450710 19.
UNIT SERVICE FACIOR.
100%
91.8%
71.9%
20.
UNIT AVAIIABILITY FACIUR.
100%
91.8%
71.9%
21.
UNIT CAPACITY FACIOR (USING MDC NET).
95.4%
92.4%
65.9%
i 22.
UNIT CAPACITY FACIOR (USING DER NET).
90.9%
- 88. lT 62.8%
23.
UNIT FORCED OUTAGE RATE.
0.0 0.0 11.1 24.
SHUIDOWNS SCHEDULED OVER NEKI 6 FDNIHS (TYPE, DATE AND DURATION OF EACH).
Refuel outage to cmmence 880826 and last approximately 75 days.
25.
IF SHUR DOWN Ar END OF REPORT PERIOD, ESTIMATED DATE OF STARIUP:
26.
UNIIS IN TEST STATUS (PRIOR 10 (X)bMERCIAL OPERATION):
FURECAST ACHIEVED INITIAL CRID?ALITY INITIAL ELECIRICITY 0@MERCIAL OPERATION (k
8803150175 8807C3 PDR ADOCK 05000333
\\\\
R PDC
y,7 DOCKET NO: 50-333
-UNIT.FITZPATRICK DATE: August, 1988 COMPLETED BY: JOHN-COOK F
. TELEPHONE: (315)349-6569
' MONTH:. JULY 1988 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE' DAILY POWER LEVEL MWe NET MWe NET l'
616 17 745-2 792 18 740 3
795 19 742 4
796 20 713 5
795 21 759
.6 794 22 779 7
791 23 757 8
786 24 760 9
779 25 720 10 749 26 712 11 753 27
/06
.12 722 28 662 13 738 29 707 14 770 30 680
-15 751 31 672 16-723
SUMMARY
Power was reduced to clean all condenser water boxes the first day of the reporting period.
The unit retuned to full power operation until 880716 when a coast down to refueling was commenced,
.w
DOGET Nos 50-333 UNIT NAMEg FITZPATRIm
- i DATE: August, 1988-REPORT M)NIH: JULY 1988 O@fPLETED BY: JOHN 000K
~
TEEPHONE: (315)349-6569~ ~
D C
UH R
MEIHOD S
O 2O E
OF YC MC CAUSE AND CORRECTIVE ACTION AU A
SHUlTDC LICENSEE SO PO 10.
NO.
DATE TYPE TR S
DOLW EVENT TD 0D PREVENT RECURRENCE IS O
THE REPORT EE NE O
N REACIOR M
E N
N T
3 880701 F
N/A H
N/A N/A SG COND REDUCED POWER TO CLFAN ALL CONDENSER WATER BOXES THEN RETURNED TO RH1 POWER OPERATION 4
880716 S
N/A C
N/A N/A O@EENCED OQAST DOWN TO REFUELING k
1 2
3 4
F: FORCED REASON:
MEIHOD:
EXHIBIT G.- INSTRUCTIONS S: SCHEDUED A. EQUIPMENT FAILURE (EXPLAIN) 1-FANUAL FOR PREPARATION OF DATA B. MAINTENANCE OR TEST
- 2-FMJAL SCPAM ENIRY SHEEIS FOR LICENSEE C. RERJELING 3-AUIWATIC SCRAM EVENT REPORT (ER) FILE D. REGUIATORY RESIRICTION 4-00NTINUED (NUREG-0161)
E. OPERATOR TRAINING AND LICENSE EXAMINATION 5-REDUCED IDAD F. AININISTRATIVE 9-OIHER G. OPERATIOtML ERROR (EXPIAIN)
H. OIHER (EXPIAIN) z
~
l NARRATIVE
SUMMARY
OF OPERATING EXPERIENCE JULY 1988 The FitzPatrick. plant operated at reduced power for the first day of the reporting period to clean the condenser water boxes.
The unit returned to full power on July 2nd and operated until July 16th when a coast down to refueling was commenced.
At the end of the reporting period the unit is operating at approximately 672 MR
- e
~
NEW YORK POWER AUTHORITY
, _.m JAMES A. FITZPATRICK NUCIEAR F0WER FIANT
- r. N SlM4ARY OF SAFE 1Y REIATED MAINrfMANCE
- .2 1
}-
DOCKER NO: 50-333
[ NIT NAME: FITZPATRICK"~
DATE: August 1983_-
OCNFIEIE BY: JOtN 000K TELEPHONE: (315) 349-6569 FOR THE MMH OF: JULY 1988 WORK REQUEST NO.
HOW CAUSE OF RESULTS OF ACTION TAKEN TO REPAIR DATE SYSTDi CWPONENT NO.
Dra m t w MAIJUNCTION MAIRINCTION PRECLUDE RECURRENCE TIME HOURS 880720 02 054787 OPS BAD PARIS ON FIDW UNIT CAUSES REPIACE PARIS, TEST, 40 FE-109A TEST /St}EER CARD AIARM, ROD BIDCK CALIBRATE 880706 02 058274 JIC Dr2wnVE TRIP STICKY MEIER PERFORM ISP-101A, 7
IGU-223A UNIT (ISP-100A)
REPIACE UNIT 880711 07 060612 OPS UNKNOWN,.DID F APRM GIVES.5 VR-2 OUT OF SPECS, 35 RI-80F IMP-7.6 AND.25 SCRAMS WAS REPIACED 880708 23 061326 JIC Dr2 m nVE TRIP OUTPUT STICKING WAS REPIACED WITH 6
MIU-268B UNIT IN TRIP POSITION NEW ONE l
a
,e J:me3 A. Fit:P: trick Nucle:r Power Pl:nt Po %= 41 Lycomug. New York 13093 315 342 3840 Radford J. Converse
- > NewYorkPower 4# Authority July 8, 1988 JAFP-88-0739 Director, Office of Inspection and Enforcement U.S. Nuclear Regulatory Coramission Washington, D.C. 20555 ATTENTION:
DOCUMENT CONTROL DESK
REFERENCE:
DOCKET NO. 50-333
Dear Sir:
Enclosed please find the J. A. FitzPatrick Nuclear Power Plant Operating Status Report for the month of July 1988.
Refueling information remains the same as previously submitted.
If there are any questions concerning this report, please contact John Cook at (315) 349-6569.
RADFORD J. CONYqh ENCLOSURES
(
v as
(
RJC:JPC:mac cc:
Distribution SEY