JAMES A. FITZPATRICK NUCLEAR POWER PLANT OPERATING DATA REPORT DOCKET No. 50-333 UNIT NAME FITZPATRICK DATE MARCH 1987 00MPIEIED BY JCHN COOK TELEPHONE (315) 349-6569 OPERATING STATUS 1.

UNIT NAME:

FITZPATRICK NUIES 2.

REPORTING l'exlou: 870201 - 870228 3.

LICENSED THERMAL POWER (NI):

2436 4.

NAMEPIRE RATING (GROSS MWE):

883 5.

DESIGN ELECIRICAL RATING (Nt;r NWE):

816 6.

MAXIMLH DEPENDABLE CAPACITY (GROSS MWE):

823 7.

MAXIMN DEPENDABLE CAPACITY (NET WE):

794 8

IF CHANGES OCCUR IN CAPACITY RATINGS (utMS 3 - 7) SINCE IME Kt.tuu, GIVE REASONS:

NONE 9.

IUWER IEVEL ID WICH KtMKIUrtD, IF ANY (Nt;r NWE):

NONE 10 REASONS EUR RESTRICTIONS, IF ANY:

THIS FONIH YR-10-DATE CUMUIATIVE 11 HOURS IN REPvKnNG PERIOD:

672 1416 101617 12.

NLMBER OF HOURS REACIOR WAS CRITICAL:

0 356.2 73847.6 13.

REACIOR RESERVE SHUrDOWN HOURS:

0 0

0 14.

HOURS GENERATOR ON-LINE:

0 355.1 71813.4 15.

UNIT RESERVE SHUrDOWN HOURS:

0 0

0 16.

GROSS THERMAL ENERGY GENERATED (MWH):

0 664368 154797490 17.

GROSS ELECIRICAL ENERGY GENERATED (FMI):

0 220070 53043030 18.

NET ELECIRICAL ENERGY GENERATED (MWH):

0 210865 50790995 19.

UNIT SERVICE FACIOR:

0 25.1%

70.7%

20 UNIT AVAIIABILITY FACIOR:

0 25.1%

70.7%

21.

UNIT CAPACITY FACIOR (USING MDC NET):

0 18.8%

64.5%

22.

UNIT CAPACITY FACIOR (USING DER fET):

0 18.2%

61.3%

23.

UNIT EURCED OUTAGE RATE:

0 0%

12.0%

i l

24.

SHUrDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, D ME AND DURATION OF EACH):

l 25.

IF SIRTE DOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP:

April 15, 1987 l

26.

UNITS IN TEST STATUS (PRIOR TO 00mERCIAL OPERATION):

E0 RECAST ACHIEVED l

INITIAL CRITICALTrY f

INITIAL ELECIRICITY 00mERCIAL OPERATION N

0703120419 870228 I$

PDR ADOCK 05000333 R

PDR t (

JAMES A, FITZPATRICK NUCLEAR POWER PLANT AVERAGE DAILY UNIT POWER IEVEL DOCKER to: 50-333 UNIT: FITZPATRICK DATE: March 1987 00MPIETED BY: John Cook TELEPHONE: (315)349-6569 M)NIH FEBRUARY 1987 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL MWe NET We NET 1

0 17 0

2 0

18 0

3 0

19 0

4 0

20 0

5 0

21 0

6 0

22 0

7 0

23 0

8 0

24 0

9 0

25 0

10 0

26 0

11 0

27 0

12 0

28 0

13 0

29 14 0

30 15 0

31 16 0

SlFMARY: 'Ihe FitzPatrick plant remined shutdown for refueling for the entire reporting period.

~ -

JAES A.' FITZPATRIOC MKIJ!' R PWER FIANT

'a A

LNIT SHUID0bMS APO P055!R REDUCTIGES '

~

DomEr ND: 50-333-INIT NAME: FITZPATRICK.

DATE: March 1987. ~

REPORT E NIH FEBRUARY 1987-03HEI1!D BY: John Cook -

TE EPHONE: (315)349-6569' D

C UH R

ME'IMD S-O RO E

OF YC MC CAUSE AIO CORRECTIVE ACTION.

AU A

SHUITING LICENSEE SO PO TO NO.

DATE TYPE TR S

DOWN EVENT TD 0D PREVENT RECURRENCE IS O

THE REPORT EE NE 0

N REACIOR M

E N

N T

1 8702.01 S

672 C

1 N/A N/A N/A SHUID065 FOR REFUELING EPO OF CYC m 7 (CLMJLATIVE HOURS.1060.9) 1 2

3 4

F: FORCED REASON:

MET E D:

EXHIBIT G.- INSIRUCTIGIS '

S: SCHEDULED A. EQUIFMENT FAILURE (EXPLAIN) 1-MANUAL FOR PREPARATION OF DATA-B. MAINIENANCE OR TEST 2-MANUAL SCRAM ENIRY SHEETS FOR LICENSEE C. REF1ELING 3-AUI0MATIC SCRAM FVENT REPORT-(MR) FILE D. REGULATORY RESTRICTION 4-0INER (EXPIAIN)

(NUREG-0161)

E. OPERA 10R TRAINING APO LICENSE EXAMINATION F. ADMINISTRATIVE G. OPERATIONAL ERROR (EXPIAIN)

H. OIHER (EXPLAIN)

t

-NARRATIVE

SUMMARY

OF OPERATING EXPERIENCE 4

FEBRUARY 1987 4

The FitzPatrick plant remained shutdown for refueling the entire-reporting period.

The estimated date of startup is April 15, 1987.

?

s 1

4 I

t I

t

!l.---

-..,. _,.. ~.... _ _. _., _ _ _.,

is

NEW YORK POWER AUIHORITY JAMES A. FITZPATRICK NUC AR POWER PLANI MAINIMIANCE SLM4ARY DOCKET NO:

50-333 LNIT NAME:

FITZPATRICK-DATE:

W.RCH 1987 OCNPIEEED BY:

JOHN COOK.

_i FOR THE E NIH OF: FEBRUARY 1987 TELEPHONE:

.(315) 349-6569 W RK REQUEST NO.

HOW CAUSE OF RESULTS OF ACTION'TAKEN TO REPAIR DATE SYSTEM GEPUNENI ND.

Dnuatu MALFUNCTION MALFUNCTION PRECLUDE RECURRENCE TIME HOURS 870224 00 050718 JIC N/A NO FAIL:REPIACE REPLACE WITH REPAIRED /

1 ATIS CAL CALIBRATION UNITS NEW UNITS 870214 02 050701 JIC BAD CWPONENT GROSS FAIL W N'T REPIACE FROM STOCK; 22 MIU-217D ON BOARD RESET ISP-101D 870212 02-3 043355 JIC VALVE NEEDS ISOIATION VALVE F-IMP-G10 8

PS-51C REPIACEMENT LEAKS DURING TEST 870214 02-3 050566 JIC N/A NO FAILURE:

F-ISP-276B 24 RX LVL INST'S PERFORM ISP-276B 870205 02-3 052880 OPS NEEDED AIMUSIMENT LEVEL READING HIm IMP-2-3.4: INDICATION 7

LT-61 APPROX. 20" 00NSISTENT 870209 03 050522 JIC N/A NO FAILURE:

INSTALLED SPARE UNIT 1-DFT-231 SP REPLACE PLUGS 870228 03 050688 JIC DmLnVE TRIP IMPROPER RESPONSE REPIACE FRCE STCCK 38' MIU-331H UNIT IN ISP-101D PAGE 1 OF 5

NEW YORK POWER AUDORITY JAMES A. FITZPATRICK IRX1 EAR POWER FIANT MAINIENANCE SUWARY DOCKET NO:

50-333 UNIT NAME:

FITZPATRICK DATE:

MARCH 1987 034PIEIED BY:

JOHN 000K FOR 'IHE FONIH OF: FEBRUARY 1987 TELEPHONE:

(315) 349-6569 WRK REQUEST NO.

HOW CAUSE OF RESULTS OF ACTION TAKEN TO REPAIR DATE SYSTDi C WPOSENT NO.

DEFECTED MALFUNCTION MALRJNCTION PRECLUDE RECURRENCE TDE 10URS 870212 03 052925 OPS RELAYS, FUSES, CAN'T GET REPIACE FUSES, 15 ROD DISPIAY TRANSISIORS BISN GREEN / RED TRANSISIORS; FULL IN/OUT RESTORE RELAYS 870220 03 052999 OPS BAD BUFFER CARD NO FULL-IN REPIACED G33, Q16 6

VARIOUS CWPOBIITIS ROD 26-35; CAN'T SELECT 870222 03 053034 OPS K17 AND K6 CIRCUIT B4ERGENCY IN/tDIG REPLACE RELAYS K17, K6 5

tUIG OVERRIDE OVERRIDE NO SIGNAL 870206 05 050680 JIC IEITER 188.1 NONE; CHECK TORQUE PANEL 09-17 8

HFA REIAYS DUED 11/14/86 PER G.E.

870217 05 050697 JIC CDU. ASSEMBLY to FAILURE: CHECK IMP-T20 12 RPS HFA'S SCREWS 'A' RELAYS TORQUE OF 4 870204 06 052853 OPS GEARDE BOUND UP BIACK PEN WN'T REPIACE: CALIBRATE 8

IR/PR-97 F0VE MANUAILY RED AND BIACK PAGE 2 0F 5

NEW YORK POWER AUIBORITY JAMES A. FITZPATRICK NUCLEAR POWER FIAhT MAHmmce SuwARv DOCKER NO:

50-333 I

UNIT NAME:

FITZPATRICK DATE:

MARCH 1987 l

CmPIEIED BY:

JOHN 000K FOR THE FONIH OF: FEBRUARY 1987 TELEPHONE:

(315) 349-6569 WRK REQUEST to.

HOR CAUSE OF RESULTS OF ACTION TAKEN TO REPAIR DATE SYSIDi (XEPONENT NO.

Dr.T w i w MAIRN, TION MALFUNCTION PRECLUDE RECURRENCE TIME i

HOURS 870204 07 044497 OPS TW FAILED INPUIS RFswxE APRM F REPLACE WITH 000D 14 t04-80F 10 OPER STATUS INPUIS FPai GROUP A 870212 07 045584 OPS BAD O TPONENIS FU INDICATION REPIACE; CALIBRATE 56 FU-14 MISMATGES ISP-63-1 l

l l

870207 07 050686 JIC DefwnVE ION DOES NOT RESP 0tB REPIACE FRm STOCK; 8

LPRM 12-29A CHAMBER POWER TO TEST IAAD IMP-7.6 SUPPLY 870212 13 050700 JIC BIBCK ON 000EACIS PRIMARY REIAY DETALL SMALLER BIDCK 12 A-K6 TOO BIG DIDN'T ENERGIZE ISP-13-1 i

870202 13 052949 OPS BAD PRESSURE RESET NOT WIIHIN REPIACE PRESS. SWITCH 8

PS-1 SWITCH 5 PSIG OF SETPOINr FR m SIOCK; IMP 13.5 870219 14 052871 OPS VALVE OUT OF PCV FAILS TO OPEN CALIBRATE 16 l

PCV-73B AI1JUSIFETT 1

PAGE 3 OF 5

q NEW YORK 10WER Alm 0RITY l

JAMES A. FITZPATRICK NUCLEAR POWER FIANT PARTIITANCE SIWARY DOCKET NO:

50-333 LNIT NAME:

FITZPATRICK l

DATE:

FARCH 1987 034PLEIED BY:

JON COOK FOR TIE MIml OF: FEBRUARY 1987 TELEPHONE:

(315) 349-6569 UDRK RF4EST 10.

HOlJ CAUSE OF RESULTS OF ACITON TAKEN TO REPAIR DAIE SYSTEM C0tGOtG2Tr ID.

DEFECIED FALFUNCITON FALFU CTION PRECLUDE RECURRENCE TIME HOURS l

870213 16 052908 OPS NORMAL kTAR HOICAIOR NEEDLE REPIACE NEEDLE AND 8

X-231A AND GAGE BROKEN MISSING GAGE 870218 23 045706 OPS SWITUI OUT OF HIGI IEVEL AIARM CALIBRATE 12 IS-98 AIUUSTMENT FRE4EITF 870225 66 041549 OPS DownVE GAUGE PRESSURE GAUGE REPLACE FROf STOCK 10 ACCU-2A OSCILIATES 40-60 870225 66 045380 OPS DmwnVE GAUGE FAISE "R1hNDC' REPIACE FRai STOCK 10 ACCU-1A HOICATION 870205 71 050679 JIC NDPFAL kTAR INSUIATION ON TAP REPAIR WITH ELECIRICAL 2

660-51B-12 10 IS SPLIT TAPE 870223 93 037076 OPS DRIFT OUT OF CALIBRATION RECALIBRATE AND AIUUST 10 EDG-C DURHE F-ST-9B 870203 93 0500024 OPS NEEDS AIUUSIMENT HDICATES 100 HIGI ADJUST NEEDLE INDICA 101L 3

T1-5B PAGE 4 OF 5

NEW YORK POWER AUIBORITY JAMES A. FITZPATRICK NUCLEAR POWER FIANT PAINIEMNCE SLWARY DOCKET No:

50-333 IUIT NAME:

FITZPATRICK DA3E:

PARCH 1987 CmPIZIED BY:

JOHN 000K EUR THE KNIH OF: IEBRIMRY 1987 TELEPHONE:

(315) 349-6569 kl0RK REQUEST 10.

HOW CAUSE OF RESULTS OF ACTION TAKEN TO REPAIR DATE SYSIDI 0090te.T NO.

DElwitu PAIRNCTION PALFUNCTION PRFN N RECURRENCE TI}E HOURS 870223 93 050712 JIC ABUSE GIASS BROKEN ON REPIACE FRO 4 SIOCK; 5

REHA-ECP TACHTEIER IMP 93.3 870223 93 050713 JIC DRIFT AWEIER INACCURATE REPIACE AND CALIBRATE 3

AM-23A OK l

870225 93 051960 OPS PREVENTIVE ID FAILURE; REPIACE; IMP 93.1 10 i

EDG-A,C PAINIEMNCE REPIACE PRESSURE del wivsS 870210 93 051961 OPS PREVENTIVE NO FAILURE; REPIACE SWIIGES, 12 EDG-B,D PAINIEMNCE REPIACE PRESSURE GASKEIS; IMP 93.1 DElw1URS 870228 93 051965 OPS RELAY 00NTACIS ESR 400 CIDSES ON REPIACE WITH REIAY FRQi 21 EDG-A STUCK DUINE START SPARE CIRCUIT 870228 93 052000 OPS SCREW JA W ED IN DC SHORTS /GROUIOS RD OVE SCRS4 80 EDG-A,C C-1 REIAY PAGE 5 OF 5

a NEM YORK POWER AUINORITY JAMES A. FITZPATRICK NUCLEAR POWER PIANT SAFEIY RELATED ELECIRICAL & MECHANICAL MAINTENANCE SLIEARY FEBRUARY 1987 REPAIR TIME TORK RQUEST #

DAIE SYSTE CmPmENT IKM in9 M a w CAYN OF MAUUNCTION ACTIN TAKEN TO PRECIEDE RECLRRENCE HOURS 2/6 71 22546 OPS Broken Socket Replaced Imp socket 2

IUE6

--____-= _

_. _ -==.===-----

=...--_.

-___----------------------------e 1/25 13 50314 PM None Overhauled motor operator 20 N1

.- __ - -----------=_

=-

== ---- ___-

. - = _ _.

_---------=

1/29 13 50316 PM None Overhaul untor operator 20 FDV 10

=

= _ - - _ _

._ =___===----- __

....--===__

1/31 13 50317 FM None Overhaul motor operator 20 FDTI9

.--_= _ __

=

=_ _

_ _==_ __ _ _... - -.

_------------e 2/3 23 52950 PM Torque switch out of Readjusted torque switch 5

FDTZ5 adjustment


_==_--


e S-4A OPb Wom packing Adjusted packing 1

2/11 03 52721 IN-T13

=

---=.

E T6T-0A4 test

_----------=_

_ -------=_ __

_ _=

2/10 71 51603 PM Defective EC-1 device Replaced EC-1 device 7

TTWZ


m

_==-------------

2/11 03 43353 OPS Seat leak Replaced valve wedge 3

G D~706A

-=---------------<

=

___=____ ___


__ -== _-_ =--

= ___

2/22 29 30797 OPS Air leak Replaced SOV 3

3DTH6B

-=

_=_

=---------


=

_ - =----- 4 IBR 51B

.=___

___-----------------=_

=__==-=-- -- ------------=_ -__

2/12 14 52915 Hydro Worn seat Lapped seat 28 I

GP TOB i

= =-4

=-- ___ _

=_-. -


==__

4 i

Page 2 NEW YORK POWER AUIBORITY JAMES A. FITZPATRICK NLUFAR FOWER PLAhT SAFETY REIATED EECIRICAL & MECFANICAL PAINIEAIEE SLWARY FEBRUARY 1987 REPAIR WORK REQUEST f TIME DA'IE SYSTE CWPTENT HOR Dtmaru CAUSE OF PAUUNCTION ACTION TAKEN 'IO PRECLUDE RECURRENCE HOURS

__==__=- --------------------------------------------------------------------------------------------------------------.

2/6 11 52536 IIRT Wom seat Iapped seat 9

ET I6

-- --_=_

- -- =--- -==---------_---__-_---_---------_-----__------_-----------_---.

2/5 27 52651 11RT Wom seat Lapped seat 11 CAD T>8

- - - - - - - - - - - - - - = _ _ _ = = _ _ _ _ = - - - _ = _ _

2/7 27 52886 LIRT Wom seat Lapped seat 18 CAD 70


==

==- ___

.-_ _____==-----------------==-_

=------------------------------------------ _ _ = ------.

2/20 27 52884 LIRT Wom seat ring Rebuilt valve 10 XDV I17


=----___---------------------------------------------- _ _=_=---------------------------.

2/17 27 52875 LIRT Wom seat Rebuilt valve 10 EDV I35A 2/19 27 52876 LIRT Wom seat Rebuilt valve 10 EDV I35B


=__----- _

------------------------=

2/13 14 52872 OPS Wom seat Replaced valve 20 3 7 7(TB


_--__--=

-- _____-_--_-----------_==

--==-====-

======_---_----__----_---------__-_---

2/14 39 52711 LIRT Wom seat Rebuilt valve 10 EAS-T0

.----_=__ ------------------=--___-------- =___----------------=

..===

2/14 27 52648 LIRT Wom seat Rebuilt valve 10 SOV-120B

==------------==-- =--


=====_ _==---------.

2/14 27 52650 LIRT Wom seat Rebuilt valve 10 EDV I20A

====__.


=

__=-----------=_____. =-==_____ _-. _____

__------- _==-

2/14 27 52649 LIRT Wom seat Rebuilt valve 10 EDV I21A


====

==___- _ ____

.--_-----------------------=_

=______==__

_==----------------------------===_ - ----.

2/23 71 51609 OPS 52 Aux. Switch failed Replaced switch 6

T052U

_ _ _ = - - - = - - -___

___===------------- _____=____=

--======

_ = = = - _ = _ _.--_

Page 3 NEW YORK POWER AUIHORITY JAMES A. FITZPATRICK NUCLEAR IGER FIANT SAFEIY RELATED ELECIRICAL & MECHANICAL PAINIENANCE Sat 4ARY FEBRUARY 1987 REPAIR M EK REQUEST #

TIME DATE SYSTE4 C TPWENT HOLJ Duuau)

CAUSE OF MALELNCTION ACTION TAKEN TO PRFpmE RECURRENCE HOURS

= - - - - - _ - _

___ _ -=_______= =_____===-- -------____==== =-----------=_____

___------------m 2/23 20 52714 IlRT Seat wrn Rebuilt valve 30 FDV 94

= -----------------------------

_ _= --- _

==_

. -===- -

FDV I6B motor leads

==- ----------------------------<

_ - _ = = = = _ _

-====____==-=========

==------------.

_=---=_=- --

2/16 10 51187 OPS Oil seal worn Overhauled motor operator 20 FDV 57

_=_

=_____

=-==-- =-----====-

====___= ____ __ -------------------

2/26 20 52744 IlRT Worn gasket Overhauled valve 40 IDV 83


- =-

__=___==--==_________=___= =_

2/19 20 52704 IlRT Worn seat Overhauled valve 30 ZDV 95

_=

==- ---------------_====-.-

2/26 23 51386 OPS Worn packing Replaced packing 5

WPJ00

=-

====_==__.=. _ ------

__=--===

_=---

_===---------.


=_ -

====___-

I

a James A Fit:Petrick Nuclear Power Plant PO Ekn 41 Lycomog. New York 13093 315 342 3840 Radford J. Converse

  1. D NewWrkPbwer 4# Authority March 9, 1987 JAFP-87-0218 Director, Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C. 20555 ATTENTION:

DOCUMENT CONTROL DESK

REFERENCE:

DOCKET NO. 50-333

Dear Sir:

Enclosed please find the J. A. FitzPatrick Operating Status Report for the month of February, 1987.

If there are any questions concerning this report, please contact John Cook at (315) 349-6569.

ut.r&

RADFORD J. CONVERSE RESIDENT MANAGER RJC:JPC:mac Enclosures cc:

Distribution S(

G s \\

l