ENCLOSURE

NOTICE OF VIOLATION Carolina Power and Light Company Shearon Harris Unit

Docket No. 50-400 License No.

CPPR-158 The following violation was identified during an inspection conducted on July 20 - August 20, 1985.

The Severity Level was assigned in accordance with the NRC Enforcement Policy ( 10 CFR Part 2, Appendix C).

CFR 50.55(f)(1) requires CP&L to implement the quality assurance program described or referenced in the Preliminary Safety Analysis Report.

Section 1.8.5. 10 of the CP&L guality Assurance Program requires that measures be established to insure that inspections are conducted in accordance with documented instructions, procedures and drawings.

Contrary to the above, on August 2, 5 and 6, 1985 the inspector identified documentation and hardware deficiencies involving welding, bolting and reinforcing material for HVAC installations at elevations 286'nd 305'n the reactor auxiliary building.

The installations had been previously inspected and accepted by equality Control and Construction Inspection personnel, and the documentation packages had been reviewed and placed in the gA vault.

This is a Severity Level V violation (Supplement II).

Pursuant to

CFR 2.201, you are required to submit to this office within 30 days of the date of this Notice, a written statement or explanation in reply, inpluding:

(1) admission or denial of the alleged violation; (2) the reasons for the violation if admitted; (3) the corrective steps which have been taken and the results achieved; (4) corrective steps which will be taken to avoid further violations; and (5) the date when full compliance will be achieved.

Security or safeguards information should be submitted as an enclosure to facilitate withholding it from public disclosure as required by 10 CFR 2.790(d)

or 10 C@7m.@.-,