IE Insp Rept 50-553/80-04 on 800303-05.Noncompliance Noted: Rockwell Intl Automated Ultrasonic Insp Procedure Was Performed W/O Required TVA Approval
ML19323E034
Person / Time
Site: Phipps Bend 
Issue date: 03/25/1980
From: Herdt A, Kleinsorge W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML19323E027 List:
References
50-553-80-04, 50-553-80-4, NUDOCS 8005220671
Download: ML19323E034 (5)


Text

.. _ _. _..

_

... _ _ _ _ _ -. _.

._

_

..

'

.

.

'o UNITED STATES

NUCLEAR REGULATORY COMMISSION o

g

.m REGION ll

'*

o 101 MARIETTA ST., N W., SUITE 3100 Y

ATLANTA, GEORGIA 20303

o

.....

Report No. 50-553/80-04 Licensee: Tennessee Valley Authority 500A Chestnut Street Chattanooga, TN 37401 Facility Name: Phipps Bend Unit 1 Docket No. 50-553 License No. CPPR-162

-

Inspection a o

-

and Iron Nuclear Memphis, Tennessee n'

.K[einsorge

.

( 2 [{6 Inspector:

-

-

//4 Date Sign'ed Accompanying Personnel:

Col y (Training)

.

.

Approved by: /

MM 6PM A. R. Herdt M V ef, RC&ES Branch Date Signed SUMMARY Inspection on March 3 5, 1980 Areas Inspected This routine announced inspection involved 42 inspector-hours at Chicago Bridge and Iron Nuclear in the areas of preservice inspection - Review of Procedures, Observation of Work and Work Activities, and Data Review and Evaluat' ion.

Results

-

,

No new items of noncompliance or deviations were identified. A further example of the item of noncompliance reported in 50-553/79-12 (Failure to obtain inspection plan approval paragraph 3) was identified.

8005220

.

.

..

.

-.-

__..-

.

-

- - -

.

?

.

.

.

DETAILS 1.

Persons Contacted Licensee Employees

  • M. E. Gothard, Mechanical Engineer Other Organizations Rockwell International
  • C. Q. Torrijos, Project Engineer
  • J. Ortega, QA Site Representative Authorized Nuclear Inspector
  • J. L. Walker
  • C. E. Housdan Chicago Bridge and Iron Nuclear W. Rogers, Project Manager (Vessel Internals)
  • Attended exit interview 2.

Exit Interview The inspection scope and findings were summarized on March 5,1980, with those persons indicated in Paragraph 1 above. The licensee was inforced of the apparent continued noncompliance concerning failure to obtain document approval. The licensee acknowledge those findings.

3.

Licensee Action on Previous Inspection Findings (open) Infraction 553/79-12-01 - Failure to obtain Inspection Plan approval TVA letter of response dated 24, 1979, has been reviewed. The inspector noted that all actions commited to in the above response were acconrglished; however, on March 5,1980 automated ultrasonic inspection activitics were being accomplished in accordance with Rockwell International Pro'.edure N318DWP000001 Revision C " Equivalency Determination Bewteen Inslection Cables and Calibration Cables" without required TVA approval. In view of the above it is apparent that additional action is required to avo;.d con-tinued noncompliance. The licensee was informed that a supplemental response would be required.

4.

Unresolved Items Unresolved items were not identified during this inspection.

l

'

l l

,

t

..

'

i l-2-

.

S.

Preservice Inspection - Review of Procedures The applicable Code for preservice and inservice inspection is the ASME B and PV Code Section XI 1974 Edition through summer 1975 Addenda as implemented by TVA QA Program. The inspector reviewed the preservice inspection procedures indicated in the following paragraphs to determine whether the procedures were consistent with regulatory requirements and licensee commitments.

a.

The following procedures were reviewed in the areas of procedure approval, requirements for qualification of NDE personnel, and procedure scope:

Procedure Number Title

_

N318TP000001, Rev. C

" Ultrasonic Examination of Reactor Vessel Welds (Phipps Bend)"

N318DWP000001 Rev. C

" Equivalency Determination Between Inspection Cables and Calibration Cables" (Note: Revision C had not been approved by TVA - See paragraph 3 for discussions)

b.

Procedure Nos. N318TP000001 and N318DWP000001 were reviewed for technical content in the areas of type of apparatus, extent of coverage, calibration requirements, size, angle and frequencies of search units, methods of compensation for metal distance traveled by ultrasonic beam, reference level for monitoring discontinuities, method of demonstrating penetration, limits for evaluation and recording of indications, method of recording significant indications, and acceptance limits.

c.

Procedure Nos. N318TP000001and N318DWP000001 were reviewed in conjunction with the QA Manaual to determine if compilation of required records were specified.

In the areas inspected, no new items of noncompliance or deviations were identified.

6.

Preservice Inspection - Observation of Work and Work Activities

,

i The inspector observed the preservice activities described below to determine whether these activities were being performed in accordance with regulatory requirements and licensee approved program and procedures. See paragraph 5 above for the applicable code.

a.

Personnel qualification records for two level 1, two Level IIA and one Level III examiner were reviewed.

b.

In-Process ultrasonic examination, including portions of the calibration sequence were observed for circumferential butt weld AD, increments 6 to 7 and 9 to 10. The examination included straight and angle beam with automatic equipment.

_ _. _ _ _. _.. _... _ _ _ _.. _.. _ _ _ _ _. _.. _. _.

__

_. _ _ _ _ _.. _.. _

..

,

.

-3-

,

The above inspections were compared with the applicable procedures in the following areas:

Use of specified type of apparatus.

-

Extent of coverage and scanning technique.

-

Calibration method including frequency and use of required calibration

-

block Size and frequencies of search units.

-

Beam angles and DAC curves.

-

Definition of reference level for monitoring discontinuities.

-

Demonstration of penetration.

-

Limits for evaluating and recording indications.

-

Acceptance limits.

-

Use of instruction manual or program procedure.

-

-

Personnel thoroughly familiar with inspection systems.

Examination provides for 100% volumetric coverage.

-

Continuous recording of reproducible data with accurate orientation to

-

the reference points.

c.

(Closed) Unresolved Item 553/79-12-02 Conformance of Calibration Cable to ASME Code This item concerns the use of an " extra" calibration cable meeting the intent of the ASME Code. Rockwell has requested ASME Code clarification, and reviewed a response indicating that the " extra" cable is within the intent of the ASME Code.

Further Rockwell has revised procedure N318TP000001 "Ultrasomic Examination of Reactor Vessel Welds (Phipps Bend)" and written procedure N318DWP000001 " Equivalency Determination Between Inspection Cables and Calibration Cables" to describe the employment of the " extra" cable. The above is considered acceptable and this item is closed.

In the areas inpsected no items of noncompliance or deviations were identified.

l 7.

Preservice Inspection - Data Review and Evaluation The inspector reviewed reactor vessel preservice inspection records indicated i

in the following paragraphs to determine whether the records were consistent with regulatory requirements and licensee commitments. See paragraph 6 for

,

the applicable code.

The records for the following joints were reviewed in the areas of, results a.

and data sheets, equipment data, calibration data sheets, evaluation data, extent of examination, deviation from program, disposition of findings, re-examination data, and identification of NDE materials.

Weld No.

Description BA Longitudinal butt weld BB Longitudinal butt weld BC Longitudinal butt weld N2C Nozzle to vessel weld N2E Nozzle to vessel weld l

~. -..

_ -.... _ _

_ _ _ _ _ _. _ -- - -

_._ _ --

N

..

,

..

.

'

4_

b.

The records of the welds in paragraph 7a above, were reviewed for technical content including method, extent and technique of examina-tion; data within the acceptance criteria; recording of evaluations and disposition of findings; evaluation sufficient to determine full extent of indications.

  • In the areas inspected no items of noncompliance or deviations were identified.

!