IR 05000361/2002003

From kanterella
(Redirected from IR 05000362/2002003)
Jump to navigation Jump to search
IR 05000361/2002-003, IR 05000362/2002-003; on 1/07/2002-1/11/2002 Southern California Edison; San Onofre Nuclear Generating Station, Units 2 and 3; Radiation Safety Team Inspection Report
ML020430326
Person / Time
Site: San Onofre  
Issue date: 02/11/2002
From: Good G
Division of Nuclear Materials Safety IV
To: Ray H
Southern California Edison Co
References
IR-02-003
Download: ML020430326 (15)


Text

February 11, 2002

SUBJECT:

SAN ONOFRE NUCLEAR GENERATING STATION, UNITS 2 AND 3 - NRC RADIATION SAFETY TEAM INSPECTION REPORT 50-361/02-03; 50-362/02-03

Dear Mr. Ray:

On January 11, 2002, the NRC completed an inspection at your San Onofre Nuclear Generating Station, Units 2 and 3. The enclosed report documents the inspection findings which were discussed with Mr. R. W. Krieger, Vice President, Nuclear Generation, and other members of your staff.

The inspection examined activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license.

The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel. Specifically, the inspectors evaluated the inspectable areas within the Radiation Protection Strategic Performance Area which are scheduled for review every two years. These areas are:

Radiation Monitoring Instrumentation

Radioactive Gaseous and Liquid Effluent Treatment and Monitoring Systems

Radioactive Material Processing and Transportation

Radiological Environmental Monitoring Program and Radioactive Material Control Program No findings of significance were identified.

In accordance with 10 CFR 2.790 of the NRC's "Rules of Practice," a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Southern California Edison Co.

-2-Should you have any questions concerning this inspection, we will be pleased to discuss them with you.

Sincerely,

/RA/

Gail M. Good, Chief Plant Support Branch Division of Reactor Safety Dockets: 50-361; 50-362 Licenses: NPF-10; NPF-15

Enclosure:

NRC Inspection Report 50-361/02-03; 50-362/02-03

REGION IV==

Dockets:

50-361; 50-362 Licenses:

NPF-10; NPF-15 Report No.:

50-361/02-03; 50-362/02-03 Licensee:

Southern California Edison Co.

Facility:

San Onofre Nuclear Generating Station, Units 2 and 3 Location:

5000 S. Pacific Coast Hwy.

San Clemente, California Dates:

January 7-11, 2002 Team Leader Larry Ricketson, P. E., Senior Health Physicist Inspectors:

Michael P. Shannon, Senior Health Physicist Daniel R. Carter, Health Physicist James S. Dodson, Health Physicist Approved By:

Gail M. Good, Chief, Plant Support Branch Division of Reactor Safety ATTACHMENT:

Supplemental Information

-2-SUMMARY OF FINDINGS San Onofre Nuclear Generating Station, Units 2 and 3 NRC Inspection Report 50-361/02-03; 50-362/02-03 IR 05000361-02-03, IR 05000362-02-03; on 1/07/2002-1/11/2002; Southern California Edison; San Onofre Nuclear Generating Station, Units 2 and 3; Radiation Safety Team Inspection The inspection was conducted by a team of four region-based inspectors. Based on the results of the inspection, no findings of significance were identified. The significance of most findings is indicated by their color (Green, White, Yellow, Red) using IMC 0609, Significance Determination Process, (SDP). Findings for which the SDP does not apply are indicated by No Color or by the severity level of the applicable violation. The NRC's program for overseeing the safe operation of commercial nuclear power reactors is described at its Reactor Oversight Process website at http://www.nrc.gov/NRR/OVERSIGHT/index.html.

A.

Inspector Identified Findings No findings of significance were identified.

B.

Licensee Identified Violations A violation of very low significance which was identified by the licensee was reviewed by the inspectors. Corrective actions taken or planned by the licensee appear reasonable.

This violation is listed in Section 4OA7 of this report.

-3-Report Details 2.

RADIATION SAFETY Cornerstones: Occupational Radiation Safety [OS] and Public Radiation Safety

[PS]

2OS3 Radiation Monitoring Instrumentation (71121.03)

a.

Inspection Scope To evaluate the adequacy of the programs to calibrate radiation monitoring instruments and to provide self-contained breathing apparatus, the inspectors interviewed cognizant licensee personnel, observed instrumentation in the field, and compared the following items to regulatory requirements:

Calibration, operability, and alarm setpoint, when applicable, of selected radiation detection instrumentation (Quicky and Accuscan whole-body counters, the Gamma 60 and IPM8 personnel monitors, and RO-2 and Teletector portable radiation instruments), continuous air monitors, electronic alarming dosimeters, personnel contamination monitors, area radiation monitors, and containment high range monitor (Unit 3, Train B)

Calibration and alarm setpoint of selected process radiation monitoring instrumentation (Unit 2, Train A, Control Room Intake; Unit 2, Train A, Fuel Handling Building; and Unit 3, Train A, Containment Airborne)

Calibration source traceability

Calibration expiration and source response check currency of radiation detection instruments staged for use

The status of self-contained breathing apparatuses staged and ready for use in the plant and associated surveillance records

The licensees capability for refilling and transporting self-contained breathing apparatus air bottles to and from the control room and operations support center during emergency conditions

Control room operator and emergency response personnel training and qualifications for use of self-contained breathing apparatus

Radiation protection department self-assessment reports dated May 4 and July 31, 2001, and sections of Quality Assurance Audit Report SCES-009-010 that pertained to the radiation monitoring instrumentation and self-contained breathing apparatus programs

Selected corrective action documents that involved radiation monitoring instrument deficiencies or self-contained breathing apparatuses initiated since

-4-the previous inspection in this area in February 2001 (AR 01020066, AR 010201325, AR 010200413, AR 010300061, AR 01031160, AR 01031068, AR 11200256, AR 011201176, and AR 011211131)

b.

Findings No findings of significance were identified.

2PS1 Radioactive Gaseous and Liquid Effluent Treatment and Monitoring Systems (71122.01)

a.

Inspection Scope To ensure that the gaseous and liquid effluent processing systems were maintained so that radiological releases were properly mitigated, monitored, and evaluated with respect to public exposure, the inspectors interviewed cognizant personnel, walked down the major components of the gaseous and liquid release systems, reviewed the following items, and compared the results with regulatory requirements:

1999 and 2000 Radiological Effluent Release Report

Changes to the Offsite Dose Calculation Manual and to the radioactive waste system design and operation

Anomalous results, if any, reported in the Radiological Effluent Release Report

Effluent radiological occurrence performance indicator incidents

Sample collection and analysis of liquid and gaseous effluents

Selected radioactive liquid waste release permits and associated projected doses to members of the public

Compensatory sampling and radiological analyses conducted when effluent monitors were declared out-of-service

Monthly, quarterly, and annual dose calculations

Air cleaning system surveillance test results

Surveillance test results for the stack and vent flow rates

Records of instrument calibrations performed since the last inspection for each point of discharge effluent radiation monitor and flow measurement device

Effluent radiation monitor alarm setpoint values

Calibration records of counting room instrumentation associated with effluent monitoring and release activities

-5-

Quality control records for the counting room instruments

Second Quarter Chemistry Division Performance Assessment

Surveillance Report S0S-052-01

Selected corrective action documents that involved the radioactive effluent treatment and monitoring program or engineered safety feature air filtration systems initiated since the previous inspection in this area in June 2001 (AR 10700550, AR 010700840, AR 10701402, AR 011201129, and AR 011201822)

b.

Findings No findings of significance were identified.

2PS2 Radioactive Material Processing and Transportation (71122.02)

a.

Inspection Scope No significant radioactive shipments were conducted during the inspection. Therefore, no direct observations could be made. To verify that the licensees radioactive material processing and transportation program complied with the requirements of 10 CFR Parts 20, 61, and 71 and Department of Transportation regulations contained in 49 CFR Parts 170-189, the inspectors interviewed licensee personnel, walked down liquid and solid radioactive waste processing systems, reviewed the following items, and compared the results with regulatory requirements:

Radioactive material processing and shipping procedures

The status of radioactive waste process equipment that was not operational and/or abandoned in place

Changes made to the radioactive waste processing systems since the last inspection in January 2000

Waste stream mixing and/or sampling procedures, methodology for waste concentration averaging, and waste classification procedures

Radio-chemical sample analysis results for each of the radioactive waste streams

The use of scaling factors and calculations used to account for difficult to measure radionuclides

Changes in waste stream composition due to changing operational parameters and analysis updates

-6-

Shipment packaging, surveying, labeling, marking, placarding, vehicle checks, emergency instructions, disposal manifest, shipping papers provided to the driver, and licensee verification of shipments

Transport cask certificates of compliance and cask loading and closure procedures

Transferees licenses and state/DOT permits

Training program for the conduct of radioactive waste/material processing, packaging and shipping activities

Eight nonexcepted package shipment records (00-1004, 01-1014, 01-1019, 01-1020, 01-1036, 01-2002, 01-2006, and 01-2007)

Nuclear Oversight Division Audit SCES-006-00, and seven self assessments (Health Physics Division First Quarter 2000, Second Quarter 2000, Third Quarter 2000, Fourth Quarter 2000, First Quarter 2001, Second Quarter 2001, and Third Quarter 2001) related to the radioactive material and transportation programs performed since the last inspection in January 2000

Selected corrective action documents involved in the radioactive material processing and shipping programs initiated since the previous inspection in this area in January 2000 (AR 000100598, AR 000901130, AR 000901131, AR 001000361, AR 001001012, AR 001001201, AR 001001640, AR 010301157, AR 010401162, AR 010501190, AR 011201762, and AR 020100183)

b.

Findings No findings of significance were identified.

2PS3 Radiological Environmental Monitoring Program and Radioactive Material Control Program (71122.03)

a.

Inspection Scope To verify that the Radiological Environmental Monitoring Program was implemented consistent with the licensees Technical Specifications and/or Offsite Dose Calculation Manual, the inspectors interviewed cognizant licensee staff members, reviewed the following areas or items, and compared the results to regulatory requirements.

  • Preparation of airborne particulate and charcoal sample holders for sample collection and shipment

Meteorological instrument data displays at the control rooms

Nine environmental air sampling stations (1, 7, 9, 10, 11, 12, 13, 14, and 15),

one vegetation sampling station (6), and seven thermoluminescent dosimetry stations (10, 12, 40, 65, 66, 67, and 74)

-7-

Implementing procedures for the radiological environmental monitoring program

Number and location of the environmental sampling stations as specified in the Offsite Dose Calculation Manual

Environmental sample analytical results

Calibration and maintenance records for environmental air sampling equipment and radiation measurement instrumentation

Changes to the radiological environmental monitoring program

1998, 1999, and 2000 Annual Radiological Environmental Operating Reports

The environmental laboratorys performance in the interlaboratory comparison program

Implementing procedures for the meteorological monitoring program

Meteorological instrument operability, reliability, and annual meteorological data recovery

Nuclear Oversight Division Quality Assurance Audit Report SCES-910-99, surveillance reports (028-00 and 030-01), and NUPIC audits (DE&S 1-98, OEES-1-99, and DESEL-1-01)

No material was released from the restricted area during the inspection. Therefore, no direct observation could be performed. However, to ensure that the licensees surveys and controls were adequate to prevent the inadvertent release of licensed materials into the public domain, the following items were reviewed and compared with regulatory requirements:

Procedures, methods, and instruments used to survey, control, and release materials from the radiologically controlled and restricted areas

  • Calibration procedures and records for instruments used to perform radiological surveys prior to material release

Detection sensitivities of radiation survey instruments used for the release of potentially contaminated materials from the radiologically controlled and restricted areas

Criteria used for the unrestricted release of potentially contaminated material from the restricted area

Nuclear Oversight Division surveillance reports (SOS-019-00 and SOS-005-01)

Selected corrective action documents involved with the radiological environmental monitoring program or radioactive material control program

-8-initiated since January 1, 2000 (AR 000401230, AR 001100288, AR 001100733, AR 010100381, AR 010200774, AR 010400644, AR 010501171, AR 010900750, AR 010901104, AR 011001703, and ACE 000800974)

b.

Findings No findings of significance were identified.

4.

OTHER ACTIVITIES 4OA6 Meetings

.1 Exit Meeting Summary The inspectors presented the inspection results to Mr. R. Krieger, Vice President, Nuclear Generation, and other members of licensee management at an exit meeting on January 11, 2002. The licensee acknowledged the findings presented.

The inspectors asked the licensee whether or not any materials examined during the inspection should be considered proprietary. No proprietary information was identified.

4OA7 Licensee Identified Violations The following finding of very low safety significance was identified by the licensee and is a violation of NRC requirements which meets the criteria of Section VI of the NRC Enforcement Policy, NUREG-1600 for being dispositioned as a non-cited violation. If you deny this non-cited violation, you should provide a response with the basis for your denial, within 30 days of the date of this inspection report, to the Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington DC 20555-0001; with copies to the Regional Administrator, Region IV; the Director, Office of Enforcement, United States Nuclear Regulatory Commission, Washington, DC 20555-0001; and the NRC Resident Inspector at the San Onofre Nuclear Generating Station, Units 2 and 3, facility.

NCV Tracking Number Requirement Licensee Failed to Meet 50-361/362/0203-01 Technical Specification 5.5.1 requires procedures for the control of radioactivity. Procedure SO123-VII-20.9.2, Material Release Surveys, Revision 3, Section 6.1, states that the criterion for items released from the Restricted Area is, No detectable licensed activity above background. On both August 18, 2000, and October 31, 2001, the licensee identified an example in which detectable radioactive material was inadvertently released from the restricted area. These two events were entered into the licensees corrective action program as Action Requests AR 000800974 and AR 011001703. This violation is being treated as a non-cited violation.

-9-The safety significance of this finding was determined to very low by the Public Radiation Safety Significance Determination Process because the public exposure associated with each item was less than 5 millirem and there were fewer than six events.

ATTACHMENT SUPPLEMENTAL INFORMATION PARTIAL LIST OF PERSONS CONTACTED Licensee C. Ahola, Supervisor, Radwaste Shipping and Receiving D. Axline, Licensing Engineer, G. Cook, Supervisor, Compliance B. Corbett, Supervisor, Health Physics Technical Support D. Dick, Supervisor, Effluent Chemistry P. Elliott, Supervisor, Radwaste M. Farmer, Supervisor, Health Physics A. Gray, Supervisor, Radwaste N. Hansen, Specialist, Radiological Environmental Monitoring J. Hirsch, Manager, Chemistry M. Humphrey, Supervisor, Health Physics R. Krieger, Vice President, Nuclear Generation M. Lewis, Specialist, Health Physics F. Liu, Engineer, Maintenance Engineering J. Madigan, Manager, Health Physics D. McBride, Supervisor, Radiation Monitoring R. McCann, Specialist, Effluent Chemistry D. Nunn, Vice President, Engineering and Technical Services A. Scherer, Manager, Nuclear Oversight and Regulatory Affairs NRC J. Kramer, Resident Inspector ITEMS OPENED, CLOSED, AND DISCUSSED Opened None.

Opened and Closed During this Inspection 50-361/362/0203-01 NCV Release of radioactive material from the restricted area.

Previous Items Closed None.