Re Errata to NRC Integrated Inspection Report 05000305/2005017
ML060370542
Person / Time
Site: Kewaunee Dominion icon.png
Issue date: 02/03/2006
From: Louden P
NRC/RGN-III/DRP/RPB5
To: Christian D
Dominion Energy Kewaunee
References
IR-05-017
Download: ML060370542 (6)


Text

February 3, 2006

SUBJECT:

ERRATA TO KEWAUNEE NUCLEAR POWER PLANT NRC INTEGRATED INSPECTION REPORT 05000305/2005017

Dear Mr. Christian:

On January 20, 2006, the U.S. Nuclear Regulatory Commission (NRC) issued Integrated Inspection Report 05000305/2005017 (ML0602004410). Following additional discussions with the stations training staff, it was identified that an NRC inspector misunderstood the overall results of the Licensed Operator Requalification Training (LORT) program annual examinations.

This mis-understanding of licensed operator requalification examination results has been corrected. The pass/fail results of the LORT program examination was evaluated as a green finding in the area of licensed operator requalification training. The enclosed errata contains the revised information and should be inserted where appropriate into Integrated Inspection Report 05000305/2005017.

We apologize for any inconvenience to you and your staff.

Sincerely,

/RA/

Patrick L. Louden, Chief Projects Branch 5 Division of Reactor Projects Docket No. 50-305 License No. DPR-43 Enclosure:

Errata to Inspection Report 05000305/2005017 See Attached Distribution

Mr. David