IR 05000250/2007403

From kanterella
(Redirected from IR 05000251/2007403)
Jump to navigation Jump to search
IR 05000250-07-403, IR 05000251-07-403, Turkey Point, Reply to Notice of Violations EA-07-110, 113, 116, 119
ML080720472
Person / Time
Site: Turkey Point  
(DPR-031, DPR-041)
Issue date: 03/12/2008
From: Joel Munday
NRC/RGN-II/DRS/PSB2
To: Stall J
Florida Power & Light Co
References
EA-07-110, EA-07-113, EA-07-116, EA-07-119 IR-07-403
Download: ML080720472 (3)


Text

March 12, 2008

SUBJECT:

REPLY TO NOTICE OF VIOLATIONS EA-07-110,113,116,119

TURKEY POINT - NRC INSPECTION REPORT 05000250/2007403 AND 05000251/2007403

Dear Mr. Stall:

Thank you for your reply dated February 28, 2008, submitted in response to Notice of Violations EA-07-110,113,116,119. As discussed with Mr. T. Jones on March 11, 2008, the corrective actions for these violations will be inspected during a routine baseline inspection. For administrative and time keeping purposes this memorandum will be identified as 05000250/2007403 and 05000251/2007403.

In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Should you have any questions concerning this letter, please contact me at (404) 562-4560.

Sincerely,

/RA/

Joel T. Munday, Chief Plant Support Branch 2 Division of Reactor Safety

Docket No.: 50-250, 50-251 License No.: DPR-31, DPR-41

cc: See Page 2

FP&L

ccw/enc:

William Jefferson, Jr.

Senior Vice President Turkey Point Nuclear Plant Florida Power and Light Company 9760 SW 344th Street Florida City, FL 33035

Paul Infanger Licensing Manager Turkey Point Nuclear Plant Florida Power and Light Company 9760 SW 344th Street Florida City, FL 33035

Michael Kiley Plant General Manager Turkey Point Nuclear Plant Florida Power and Light Company 9760 SW 344th Street Florida City, FL 33035

Don E. Grissette Vice President Nuclear Training and Performance Improvement Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 34408

Mark Warner Vice President Nuclear Operations Support Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420

Rajiv S. Kundalkar Vice President Nuclear Technical Services Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 34408-0420

M. S. Ross Managing Attorney Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 34408-0420

Marjan Mashhadi Senior Attorney Florida Power & Light Company 801 Pennsylvania Ave., NW, Suite 220 Washingtion, DC 20004

ccw/o encl:

William A. Passetti Bureau of Radiation Control Department of Health 2020 Capital Circle, SE, Bin #C21 Tallahassee, FL 32399-1741

Craig Fugate Director Division of Emergency Preparedness Department of Community Affairs 2740 Centerview Drive Tallahassee, FL 32399-2100

Alejandro Sera Emergency Management Coordinator Miami-Dade County 9300 NW 41st Street Miami, FL 33178

_________________________

OFFICE RII:DRS

SIGNATURE

/RA/

NAME J/ Munday

DATE 3/ /2008 3/ /2008 3/ /2008 3/ /2008 3/ /2008 3/ /2008 3/ /2008 E-MAIL COPY?

YES NO YES NO YES NO YES NO YES NO YES NO YES NO