U. S. NUCLEAR REGULATORY COMMISSION

,

,

OFFICE OF INSPECTION AND ENFORCEMENT

REGION I

50-245/80-16 Report No.

50-333/g0-17

-

50-245 DPR-21 Docket No.

50-336 License No. DPR-65 Safeguards Group C

,

Licensee:

Northeast Nuclear Enercy Comoany P. O. Box 270

.

Hartford, Connecticut 06101 Facility Name:

Millstone Nuclear Power Stations, Units 1 and 2 Inspection At:

Waterford, Connecticut Inspection Conducted:

September 21-26, 1980 Date of Last Physical Security Inspection Visit: June 23-27, 30 and July 1-3. 1980 Type of Inspect'on; Routine, Unannounced, Physical Protection Inspectors: '////[m s4

/ 8 ~~ M

-

WM nw J. Maodeh, Physical Security Inspector date U

l?. b O. W W

//Ilc1U l?0 Lisa M. McKeown, Physical Security Inspector

/ daty date Approved by /T4se/Mh

  1. O J[Japies W. Devlin, Chief, Security Section,

/ date'

feguards Branch Insoection Summary:

Insoection on Seotember 21-26,1980 (Combined Insoection Recort Nos. 50-245/80-16 and 50-336/80-17)

Areas Insoected:

Included a review of Security Plan; Security Organization; Physical Barriers (Protected and Vital Areas); Lightin Authorization and Badging); Access Controls (g; Access Control (Identification, Saarch and Escorting); Access Controls (Vital Areas); Alarm Stations; Detection Aids; Assessment Aids; Comunications; Testing and Maintenance; Compensatory Measures; Power Supply; Response; Locks, Keys and Combinations; and Records and Reports.

Also, a followup to previously identified items of noncompliance and a followup to Imediate Action Letter (IAL 80-28).

The inspection involved 72 inspector-hours onsite by two NRC Regional based inspectors.

The 1.nspection was begun during off shift, weekend hours; 5 inspector hours were performed during off shift periods.

Results: The licensee was found to be in compliance with NRC requirements within the 21 areas examined during this inspection.

Region I Form 167 81020507 h

.(August 1979)

.

.. - -

.. -

, - - -..

.---...---..--.--...:...-

.

.