IR 05000232/2014001

From kanterella
Jump to navigation Jump to search
645509-Termination License 50-23214-01 for Diagnostic Health Center of Anchorage, LLC
ML25104A150
Person / Time
Site: 05000232, 03020372
(50-23214-01)
Issue date: 03/25/2025
From: Gonzalez A
NRC/RGN-IV/DRSS/MLB
To:
Document Control Desk
References
License-645509-245607
Download: ML25104A150 (1)


Text

From:

Kay Kassel To:

Tony Gonzalez Subject:

[External_Sender] Re: DHCA License Termination Date:

Tuesday, March 25, 2025 7:56:04 AM Attachments:

DHA Source Return Records.pdf Leak Tests Q3 2024.pdf Good Morning Tony, I've attached the sealed source inventory that was taken at the time of return. There is a wipe test indicated for the shipment on the paperwork, completed by the physicist.

I also have leak tests that were completed as part of the Q3 physicist survey, attached.

The reason for closing:

Business decision related to financial performance of the site due to decreased market share and scan volume.

Please let me knowif you need anything else, Kay Kay Kassel Corporate Radiation Safety Officer logo

+1 561-701-1311 kay.kassel@akumin.com akumin.com This message contains information which may be confidential and/or privileged. Unless you are the intended recipient (or authorized to receive for the intended recipient), you may not use, copy or disclose to anyone this message or any information contained in this message. If you have received the message in error, please advise the sender by reply email and delete the message immediately from both your inbox and from your trash folder. Thank you.

On Mon, Mar 24, 2025 at 1:54PM Tony Gonzalez <Antonio.Gonzalez@nrc.gov> wrote:

Sorry, I forgot to mention to also please provide your source inventory and leak test Thank you, Tony

From: Tony Gonzalez Sent: Monday, March 24, 2025 12:50 PM

To: Kay Kassel <kay.kassel@akumin.com>

Subject: DHCA License Termination

Hello Kay,

I am processing your termination. I just wanted to inquire as to the reason the license is being terminated. Can you shed some light on the reasoning?

Best Regards,

Antonio J. Gonzalez, Health Physicist U.S. Nuclear Regulatory Commission, Region IV Division of Radiological Safety & Security Materials Licensing Branch P: 817-200-1472 E: Antonio.Gonzalez@nrc.gov

Diagnostic Health Anchorage Anchorage, Alaska Radioactive Material License Audit September 19th, 2024 Date of Leak Test: 9/19/2024 Performed by:

Date of Analysis: 9/19/2024 Analyzed by:

Instrument: Capintec Captus 4000e Serial Number Nuclide Current Source Activity (mCi)

Minimum Detectable Activity (µCi)

Leak Sample Activity (µCi)

Results 2380-126 Co-57 2.7218 3.8901E-05 5.8E-05 No Leak Sealed Source Leak Tests Marc Cramer, MS, DABR Marc Cramer, MS, DABR Sealed source leak tests were performed by CORWIN HEALTH PHYSICS INC. on the following sealed sources at your facility in accordance with 10 CFR Part 39.35 The NRC requires that the analysis of the wipe from the sealed source be capable of detecting the presence of 0.005 microcurie (185 Bq) on the sampl The counts on the above sealed source leak tests were below the minimum detectable activity (MDA), which is less than 185 Bq. The sources are not considered leakin This report should be retained for viewing by regulatory agencies.

11