49-50; License; Amendment No. 12; License No. 50-21374-01; Mail Control No. 639882
ML24179A275
Person / Time
Site: Haddam Neck, 03020575
Issue date: 06/27/2024
From: Alexus Willis
NRC/RGN-IV/DRSS/MLB
To:
Document Control Desk
References
License-639882-220381
Download: ML24179A275 (1)


Text

NRC FORM 374 PAGE OF1 4PAGES U.S. NUCLEAR REGUL ATORY COMMISSION Amendment No. 12 MATERIALS LICENSE Pursuant to the Atomic Energy Act of 1954, as amended, the Energy Reorganization Act of 1974 (Public Law 93-438), and Title 10, Code of Federal Regulations, Chapter I, Parts 30, 31, 32, 33, 34, 35, 36, 37, 39, 40, 70 and 71, and in reliance on statements and representations heretofore made by the licensee, a license is hereby issued authorizing the licensee to receive, acquire, possess, and transfer byproduct, source, and special nuclear material designated below; to use such material for the purpose(s)

and at the place(s) designated below; to deliver or transfer such material to persons authorized to receive it in accordance with the regulations of the applicable Part(s). This license shall be deemed to contain the conditions specified in Section 183 of the Atomic Energy Act of 1954, as amended, and is subject to all applicable rules, regulations, and orders of the Nuclear Regulatory Commission now or hereafter in effect and to any conditions specified belo Licensee In accordance with letter dated Expiration Date: June 30, 2039 February 7, 2024, Docket No.: 030-20575 P.O. Box 468 License No.: 50-21374-01 is Reference No.:

Soldotna, AK 99669 amended in its entirety to read as follows:. 8.Byproduct, source,Chemical and/or physical form Maximum amount that licensee Authorized use and/or special nuclear may possess at any one time material under this license For use in Troxler Electronic Cesium-137A.Sealed Sources (AEA A.9 millicuries per source Technology/QSA, Inc., Model and 18 millicuries total Laboratories Models 3400 Series CDCW556; Isotope Product portable gauging devices for Laboratories, Model HEG-137) measuring physical properties of material For use in Troxler Electronic Americium-241/ B.Sealed Neutron Source (AEA B.44 millicuries per source Beryllium Technology/QSA, Inc., Model and 88 millicuries total Laboratories Models 3400 Series AMNV.997; Isotope Product portable gauging devices for Laboratories, Model 3021, 3027 measuring physical properties of or Am1.NO2) material For use in Troxler Electronic Americium-241/ C.Sealed Neutron Source C.110 millicuries per source Beryllium (Amersham Corporation, Model and 110 millicuries total Laboratories Model 3241-C portable AMNV.340) gauging devices for measuring physical properties of materials.

NRC FORM 374A NUCLEAR REGULATORY COMMISSION PAGE 42OFPAGES License No.: Docket or Reference No.:50-21374-01 MATERIALS LICENSE 030-20575 SUPPLEMENTARY SHEET Amendment No. 12

CONDITIONS

1 Licensed material shall be used or stored at the licensee's facilities located at: Kenai Spur Highway, Soldotna, Alaska, 99669 Temporary job sites of the licensee anywhere in the United States where the U.S. Nuclear Regulatory Commission maintains jurisdiction for regulating the use of licensed material, including areas of exclusive Federal jurisdiction within Agreement States. If the jurisdiction status of a Federal facility within an Agreement State is unknown, the licensee should contact the Federal agency controlling the job site in question to determine whether the proposed job site is an area of exclusive Federal jurisdiction. Authorization for use of radioactive materials at job sites in Agreement States not under exclusive Federal jurisdiction should be obtained from the appropriate state regulatory agenc. Licensed material shall only be used by, or under the supervision and in the physical presence of, individuals who have received the training described in the application dated February 27, 2024. The licensee shall maintain records of individuals designated as users for 3 years following the last use of licensed material by the individua. The Radiation Safety Officer (RSO) for this license is Cody McLan. Sealed sources and detector cells shall be tested for leakage and/or contamination at intervals not to exceed the intervals specified in the certificate of registration issued by the U.S. Nuclear Regulatory Commission under 10 CFR 32.210 or by an Agreement State. In the absence of a registration certificate, sealed sources shall be tested for leakage and/or contamination at intervals not to exceed 6 months, or at such other intervals as specifie In the absence of a certificate from a transferor indicating that a leak test has been made within the intervals specified in the certificate of registration issued by the U.S. Nuclear Regulatory Commission under 10 CFR 32.210 or by an Agreement State, prior to the transfer, a sealed source received from another person shall not be put into use until tested and the test results receive Sealed sources need not be tested if they are in storage and are not being used. However, when they are removed from storage for use or transferred to another person, and have not been tested within the required leak test interval, they shall be tested before use or transfer. No sealed source shall be stored for a period of more than 10 years without being tested for leakage and/or contamination.

NRC FORM 374A NUCLEAR REGULATORY COMMISSION PAGE 43OFPAGES License No.: Docket or Reference No.:50-21374-01 MATERIALS LICENSE 030-20575 SUPPLEMENTARY SHEET Amendment No. 12 The leak test shall be capable of detecting the presence of 185 becquerels (0.005 microcuries) of radioactive material on the test sample. If the test reveals the presence of 185 becquerels (0.005 microcuries) or more of removable contamination, a report shall be filed with the U.S. Nuclear Regulatory Commission in accordance with 10 CFR 30.50(c)(2), and the source shall be removed immediately from service and decontaminated, repaired, or disposed of in accordance with Commission regulation Analysis of leak test samples and/or contamination shall be performed by persons specifically licensed by the U.S. Nuclear Regulatory Commission or an Agreement State to perform such services. The licensee is authorized to collect leak test samples but not perform the analysi Records of leak test results shall be kept in units of becquerels (microcuries) and shall be maintained for 3 year. Sealed sources or source rods containing licensed material shall not be opened or sources removed from source holders or detached from source rods by the licensee, except as specifically authorize. The licensee shall conduct a physical inventory every 6 months, or at other intervals approved by the U.S. Nuclear Regulatory Commission, to account for all sealed sources and/or devices received and possessed under the license. Records of inventories shall be maintained for 3 years from the date of each inventory, and shall include the radionuclides, quantities, manufacturer's name and model numbers, and the date of the inventor. Except for maintaining labeling as required by 10 CFR Part 20, or Part 71, the licensee shall obtain authorization from the U.S. Nuclear Regulatory Commission before making any changes in the sealed source, device, or source-device combination that would alter the description or specifications as indicated in the respective certificate of registration issued either by the U.S. Nuclear Regulatory Commission pursuant to 10 CFR 32.210 or by an Agreement State.

1 Each portable nuclear gauge shall have a lock or outer locked container designed to prevent unauthorized or accidental removal of the sealed source from its shielded position. The gauge or its container must be locked when in transport or storage, or when not under the direct surveillance of an authorized user.

NRC FORM 374A NUCLEAR REGULATORY COMMISSION PAGE 44OFPAGES License No.: Docket or Reference No.:50-21374-01 MATERIALS LICENSE 030-20575 SUPPLEMENTARY SHEET Amendment No. 12

1 Any cleaning, maintenance, or repair of the gauge(s) that requires detaching the source or source rod from the gauge shall be performed only by the manufacturer or by other persons specifically licensed by the Nuclear Regulatory Commission or an Agreement State to perform such service. Except as specifically provided otherwise in this license, the licensee shall conduct its program in accordance with the statements, representations, and procedures contained in the documents, including any enclosures, listed belo This license condition applies only to those statements, representations, and procedures that are required to be submitted in accordance with the regulation The U.S. Nuclear Regulatory Commission's regulations shall govern unless the statements, representations, and procedures in the licensee's application and correspondence impose on the licensee requirements that are more restrictive than or in addition to the regulation A. Application dated February 27, 2024 (ML24068A098) Letter dated April 16, 2024 with attachments (ML24135A157)

C. Letter dated May 9, 2024 with attachments (ML24135A158)

D. Letter dated February 7, 2024 with attachments (ML24067A193)

FOR THE U. NUCLEAR REGULATORY COMMISSION

Date: June 27, 2024 By:

Alexus Willis Region 4