Text
e I
U.S. NUCLEAR REGULATORY COMMISSION
REGION I
Report No.
50-20/85-02 Docket No.
50-20 License No. R-37 Licensee: Massachusetts Institute of Technology 138 Albany Street Cambridge, Massachusetts 02139 Facility Name: MIT Nuclear Reactor Laboratory Inspectio.: At: Cambridge, Massachusetts Inspection Conducted:
September 25, 1985 Date of Last Physical Security Inspection:
September 27 - 28, 1982 Type of Inspection: Routine, Unannounced, physical Security Inspector :
J
%b
//- /# -#f William J. Madden, physical Security date Inspector i
Approved by:
" ; df
//- / s - #.s'
,
R. R. Keijpg ef, Safeguards Section, date DRS&S /
Inspection Summary: Routine, unannounced, physical protection inspection on September 25, 1985 (Report No. 50-20/85-02)
Areas Inspected:
Implementation of the licensee's NRC approved physical secur-ity plan for the protection of special nuclear material (SNM) of moderate strategic significance.
The inspection involved 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> onsite by one NRC inspector.
Results: The licensee was in compliance with NRC requirements in the areas examined.
??r#E0l DOCK 050000P0 ORBO BS1121 g
PDH
.
!
REPORT DETAILS 1.
Key Persons Contacted
- Lincoln Clark, Jr., Director of Reactor Operations
- John Bernard, Superintendent, MIT Research Reactor Operations / Maintenance
- Kwan Kwok, Assistant Superintendent, MIT Research Reactor Jerry McDade, Supervisor, Campus Security Systems
- Denotes those present at the exit interview.
2.
30703 - Exit Interview The inspector met with the licensee representatives indicated in para-
,.
graph 1 at the conclusion of the inspection on September 25, 1985, and summarized the scope and findings of the inspection.
3.
81480 - Physical Protection of SNM of Moderate Strategic Significance The licensee's program for the physical protection of SNM of moderate strategic significarce was reviewed by the inspector and was found to
.
conform to NRC requirements and the licensee's implementing procedures.
l Specific components of the program that were inspected included:
records
!-
and reports; security organization; alarm response; key control; detec-tion aids; physical barriers; and written security procedures.
l l
l
l l
-