The following is a synopsis of information received via email from the
Alabama Department of Public Health, Office of Radiation Control:
On the evening of March 6, 2024, the licensee experienced a source disconnect at a job site in Russellville, Alabama. The source connector appeared to have not been connected properly, and the source apparently disconnected from the drive cable while outside the exposure device (camera). The source was retrieved and secured in a 650L model source changer about 45 minutes later when a source retrieval team arrived on site. The two source retrieval personnel received 45 milliroentgens and 15 milliroentgens of exposure respectively. The radiography crew dosimetry had not yet been retrieved for emergency processing at the time of the report.
The camera and source information is as follows: Sentinel 880D, D1120, about 78.9 curies of iridium-192 in a model A424-9 source.
Alabama Incident Number:
TBD