| Event Description | The following is a synopsis of the event received from the Georgia Radioactive Materials Program:
On July 31, 2020, a physician did not follow proper procedure while recording the number of seeds administered to a patient. The physician initially planned on administering one seed but decided to administer two. The physician did remove both seeds from the patient on August 3, 2020. The tracking system for the administered seeds was based on writing the number of seeds administered on a colored bracelet or arm band, which the patient wears while the seed(s) are implanted. It is removed and travels with the removed tissue through the remaining processes at the hospital. In this case, the physician did not revise the number on the bracelet, therefore during the subsequent processes, other hospital staff only looked for one seed to recover from the procedure by-products. One seed was not recovered. There was some discussion between departments prior to August 21, 2020 about the seed. Radiation Safety was not contacted. On August 21, 2020, an Assistant RSO discovered the discrepancy while conducting an inventory, preparing the seeds for return to the seed vendor. Subsequent searches that included the involved staff did not recover the missing seed. After a review of the laboratory processes for analyzing the removed tissue, the hospital staff believes the missing seed was retained in the transport bin and disposed of with that bin in the bio-hazard waste stream. But, this can not be proven. It was demonstrated to not be in the frozen sample that the hospital retained. The hospital declared the seed lost on August 27, 2020. The seeds were I-125 encapsulated in titanium. Model IAI-125A. Activity level calculated to be 145.1 microCuries at time of loss/disposal. The radioactivity is small, and the decay rate high such that this poses a low risk to the public. Based on literature, the RSO states the contact dose, assuming the seed was trapped in clothing (contact) for twelve hours to be 2.66 milliSeverts. The hospital has conducted a root cause analysis, and has revised its procedures and re-trained staff to prelude future loss of radioactive seeds. Incident #: 29 THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf | |
| Where | |
|---|---|
| Georgia Radioactive Material Pgm Atlanta, Georgia (NRC Region 1) | |
| License number: | GA 258-2 |
| Organization: | Georgia Radioactive Material Pgm |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+181.45 h7.56 days <br />1.08 weeks <br />0.249 months <br />) | |
| Opened: | Leslines Leveque 17:27 Sep 3, 2020 |
| NRC Officer: | Thomas Herrity |
| Last Updated: | Sep 3, 2020 |
| 54879 - NRC Website | |
Georgia Radioactive Material Program with Agreement State | ||||
WEEKMONTHYEARENS 560652022-08-23T16:00:00023 August 2022 16:00:00 Agreement State Lost Radioactive Portable Gauge ENS 548822020-09-02T04:00:0002 September 2020 04:00:00 Agreement State | Agreement State Report - Medical Event - Underdose ENS 548792020-08-27T04:00:00027 August 2020 04:00:00 Agreement State | Agreement State Report - Loss of Medical Seed After Removal from Patient ENS 548172020-07-21T04:00:00021 July 2020 04:00:00 Agreement State | ENS 546942020-05-04T04:00:0004 May 2020 04:00:00 Agreement State Agreement State Report - Patient Underdose ENS 546622020-03-31T04:00:00031 March 2020 04:00:00 Agreement State Agreement State Report - Loss of Iodine-125 Seed ENS 541102019-06-11T04:00:00011 June 2019 04:00:00 Agreement State Agreement State Report - Patient Under Dosage Due to Air Being Trapped in the Delivery Line ENS 545492019-05-02T05:00:0002 May 2019 05:00:00 Agreement State Agreement State Report - Broken Density Gauge Shutter ENS 539962019-04-03T04:00:0003 April 2019 04:00:00 Agreement State Agreement State Report - Underdose Administration of Y-90 Theraspheres ENS 545502019-01-18T05:00:00018 January 2019 05:00:00 Agreement State Agreement State Report - Improper Disposal of I-125 Seed ENS 545412018-12-18T05:00:00018 December 2018 05:00:00 Agreement State Agreement State Report - Leaking Promethium-147 Source ENS 545652018-06-29T05:00:00029 June 2018 05:00:00 Agreement State Agreement State Report - Lost Iodine-125 Seed ENS 545372018-04-03T05:00:0003 April 2018 05:00:00 Agreement State Agreement State Report - Stuck Open Shutter ENS 545632017-11-06T05:00:0006 November 2017 05:00:00 Agreement State Agreement State Report - Leaking Cesium-137 Source ENS 546442017-06-09T04:00:0009 June 2017 04:00:00 Agreement State Agreement State Report - Stuck Shutter ENS 545642016-08-09T05:00:0009 August 2016 05:00:00 Agreement State Agreement State Report - Lost I-125 Source 2022-08-23T16:00:00 [Table view] | |