| Title | Agreement State Report - Loss of Iodine-125 Seed |
| Event Description | The following was received from the state of Georgia via email:
An Iodine-125 seed [assayed at 69 microCuries on March 24, 2020 (Best Model 10172-11, Double wall titanium encapsulated, Serial Number: 49802A20)] used for breast lesion localization was shipped within a tissue specimen from Piedmont Fayette Hospital to Piedmont Atlanta and then lost into the ordinary solid waste stream, rather than being recovered and placed in decay-in-storage at Piedmont Fayette, as is the standard procedure. The seed was implanted in a patient with a breast lesion at Piedmont Fayette on March 24, 2020. The lesion containing the seed was successfully removed in surgery and sent to the pathology lab on March 30, 2020. The presence of the seed in the specimen was verified in pathology by Neoprobe measurement. There was no pathology physician assistant present that day and the pathologist was not notified. A lab staff member arranged for all specimens to be shipped to Piedmont Atlanta. The specimens, including the one containing the seed, were shipped by MedSpeed courier service that same day. At the Atlanta campus, the specimen with the seed was processed by the normal procedure on April 1, 2020. The histotechnologist there removed what he thought was a marker or a clip and discarded it in the regular waste bin. The waste containing the seed was removed from the Atlanta campus [in a bag of solid waste] and transported to the [Pine Ridge Regional Landfill] by the waste disposal company's normal procedure on or around April 2, 2020. [The Radiation Safety Officer (RSO)] was notified by phone on April 3, 2020 and searches of all relevant areas at Piedmont Atlanta were performed by staff using a GM survey meter with pancake probe as well as with a Sodium Iodide scintillator probe that day. No evidence of radiation or the seed was found in any location. The proper course of action that should have been taken in order to prevent this situation is as follows: The pathologist at Fayette should have been notified that there was a specimen with a radioactive seed. The pathologist would have removed the seed and the pathology staff would have contacted Nuclear Medicine to retrieve the seed and place it in decay-in-storage. Seeds should not leave the Fayette Campus. In [the RSO's] estimation, it is unlikely that any occupationally exposed worker or member of the public received any significant exposure or exceeded any dose limit. All staff in pathology have been educated on the circumstances that led to this incident. The procedure has been updated to clarify what actions should be taken if a specimen with a seed arrives in pathology when no pathology physician assistant is present. Knowledge of this procedure has been added to the competency checklist for pathology employees. THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf |
| Where | |
|---|---|
| Georgia Radioactive Material Pgm Fayetteville, Georgia (NRC Region 1) | |
| License number: | 1340-1 |
| Organization: | Georgia Radioactive Material Pgm |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+320.35 h13.348 days <br />1.907 weeks <br />0.439 months <br />) | |
| Opened: | Stacy Allman 12:21 Apr 13, 2020 |
| NRC Officer: | Ossy Font |
| Last Updated: | Apr 13, 2020 |
| 54662 - NRC Website | |
Georgia Radioactive Material Program with Agreement State | ||||
WEEKMONTHYEARENS 560652022-08-23T16:00:00023 August 2022 16:00:00 Agreement State Lost Radioactive Portable Gauge ENS 548822020-09-02T04:00:0002 September 2020 04:00:00 Agreement State | Agreement State Report - Medical Event - Underdose ENS 548792020-08-27T04:00:00027 August 2020 04:00:00 Agreement State | Agreement State Report - Loss of Medical Seed After Removal from Patient ENS 548172020-07-21T04:00:00021 July 2020 04:00:00 Agreement State | ENS 546942020-05-04T04:00:0004 May 2020 04:00:00 Agreement State Agreement State Report - Patient Underdose ENS 546622020-03-31T04:00:00031 March 2020 04:00:00 Agreement State Agreement State Report - Loss of Iodine-125 Seed ENS 541102019-06-11T04:00:00011 June 2019 04:00:00 Agreement State Agreement State Report - Patient Under Dosage Due to Air Being Trapped in the Delivery Line ENS 545492019-05-02T05:00:0002 May 2019 05:00:00 Agreement State Agreement State Report - Broken Density Gauge Shutter ENS 539962019-04-03T04:00:0003 April 2019 04:00:00 Agreement State Agreement State Report - Underdose Administration of Y-90 Theraspheres ENS 545502019-01-18T05:00:00018 January 2019 05:00:00 Agreement State Agreement State Report - Improper Disposal of I-125 Seed ENS 545412018-12-18T05:00:00018 December 2018 05:00:00 Agreement State Agreement State Report - Leaking Promethium-147 Source ENS 545652018-06-29T05:00:00029 June 2018 05:00:00 Agreement State Agreement State Report - Lost Iodine-125 Seed ENS 545372018-04-03T05:00:0003 April 2018 05:00:00 Agreement State Agreement State Report - Stuck Open Shutter ENS 545632017-11-06T05:00:0006 November 2017 05:00:00 Agreement State Agreement State Report - Leaking Cesium-137 Source ENS 546442017-06-09T04:00:0009 June 2017 04:00:00 Agreement State Agreement State Report - Stuck Shutter ENS 545642016-08-09T05:00:0009 August 2016 05:00:00 Agreement State Agreement State Report - Lost I-125 Source 2022-08-23T16:00:00 [Table view] | |