| Title | Gamma Alarm Fixed Radiation Portal Monitor |
| Event Description | The following was received from the state of Florida Bureau of Radiation Control via fax:
[Customs and Border Protection] CBP called the [Bureau of Radiation Control Incident Response Center] BRC IRC to report that at 1105 EST, CBP had a gamma alarm from a fixed radiation portal monitor for a 20 ft. sea container manifested as containing PVC Leather, Buckles, and Grommets. A CBP officer inspected the container using a RadSeeker DL RIID (1.5x1.5in LaBr3). The RIID identified Th-232, and this was confirmed manually by CBP lab personnel using PeakEasy gamma spectroscopy software. The highest reported dose rate was 103 microR/hr at contact with the sea container (1034 cps at contact); this is approximately 9-10 times the average background dose rate for this location. The radiation was distributed throughout the entire length of the container. Guidance requested as to whether or not CBP should refuse entry on the shipment, or if it is acceptable to release it into commerce. There are concerns as to whether or not this product may contain one-twentieth of one percent (0.05 percent) or more by weight of Th-232, violate other radiological regulations, or pose additional concerns. Notified R1DO (Henrion), NMSS Events (email), OIP Notifications Resource (email) Florida Incident Number: FL20-011
This morning between 0800 and 0900 EST, [BRC IRC] inspector went to the Blount Island Marine Terminal in Jacksonville, FL to inspect a container that US Customs and Border Protection had identified as having higher than background levels of radiation. The container was opened for [the inspector], and [the inspector] found the items in the container did match the information that was reported to the Bureau of Radiation Control (BRC). Specifically, spools of faux-leather, and boxes that contained plastic grommets and buckles. These items were manufactured or assembled in China for delivery to a pool cover supply company in Apopka, FL. The boxes did not contain radiation levels above background. The spools of faux-leather had slightly higher than background levels of radiation when unrolled. Their spindles were made of cardboard and did not have higher than background levels of radiation. When the faux-leather was rolled up, the radioactivity increased. The BRC has given the guidance that the container and its contents may be released, but this has not happened yet. If it is released, the BRC is of the opinion that the intended recipient should be surveyed for radiation, in case this is a common occurrence. Notified R1DO (Henrion), NMSS Events (email), and OIP Notifications Resource (email) |
| Where | |
|---|---|
| Florida Bureau Of Radiation Control Apopka, Florida (NRC Region 1) | |
| Organization: | Florida Bureau Of Radiation Control |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+9.93 h0.414 days <br />0.0591 weeks <br />0.0136 months <br />) | |
| Opened: | Matthew Senison 14:56 Jan 31, 2020 |
| NRC Officer: | Kerby Scales |
| Last Updated: | Feb 3, 2020 |
| 54504 - NRC Website | |
Florida Bureau of Radiation Control with Agreement State | |||||
| Agreement State Report - Vehicle Carrying Radio-Pharmaceuticals Involved in Accident ENS 549092020-09-24T13:30:00024 September 2020 13:30:00 Agreement State | Agreement State Report - Lost/Stolen Troxler Gauge ENS 549262020-09-04T04:00:0004 September 2020 04:00:00 Agreement State | Agreement State Report - Leaking Sealed Source ENS 548022020-07-27T04:00:00027 July 2020 04:00:00 Agreement State Agreement State Report - Troxler Gauge on Ebay ENS 547992020-07-23T04:00:00023 July 2020 04:00:00 Agreement State Agreement State Report - Lost Shipment of I-125 Seeds ENS 547882020-07-17T04:00:00017 July 2020 04:00:00 Agreement State Agreement State Report - Underdose Administered to Patient ENS 547862020-07-16T04:00:00016 July 2020 04:00:00 Agreement State Agreement State Report - Medical Misadministration ENS 547822020-07-14T13:15:00014 July 2020 13:15:00 Agreement State Agreement State Report - Therasphere Procedure Underdose ENS 547632020-07-01T04:00:0001 July 2020 04:00:00 Agreement State Agreement State Report - Medical Event ENS 547432020-06-05T04:00:0005 June 2020 04:00:00 Agreement State Agreement State Report - Medical Event ENS 547172020-05-12T04:00:00012 May 2020 04:00:00 Agreement State Agreement State Report - Medical Event ENS 547032020-05-12T00:30:00012 May 2020 00:30:00 Agreement State Agreement State Report - Lost Gauge ENS 547042020-05-11T04:00:00011 May 2020 04:00:00 Agreement State Agreement State Report - Patient Underdose ENS 546842020-04-20T04:00:00020 April 2020 04:00:00 Agreement State Agreement State Report - Used Beverage Can (Ubc) Baled Aluminum Returned to Florida ENS 546182020-03-26T04:00:00026 March 2020 04:00:00 Agreement State Agreement State Report - Damaged Moisture Denisty Gauge Case ENS 545582020-03-02T21:30:0002 March 2020 21:30:00 Agreement State Agreement State Report - Source Failed to Retract ENS 545442020-02-24T18:15:00024 February 2020 18:15:00 Agreement State Agreement State Report - Patient Underdose ENS 545482020-02-24T05:00:00024 February 2020 05:00:00 Agreement State Medical Event - Hdr Underdose to Patient ENS 545832020-02-03T04:00:0003 February 2020 04:00:00 Agreement State Agreement State Report - Loss of Control of a Cs-137 Source ENS 545042020-01-31T05:00:00031 January 2020 05:00:00 Agreement State Gamma Alarm Fixed Radiation Portal Monitor ENS 544582019-12-30T05:00:00030 December 2019 05:00:00 Agreement State Agreement State Report - Unaccounted Material ENS 544552019-12-20T05:00:00020 December 2019 05:00:00 Agreement State Agreement State Report - Patient Underdose ENS 544392019-12-11T05:00:00011 December 2019 05:00:00 Agreement State Agreement State Report - Dose Delivered Less than Prescribed ENS 516262015-12-29T13:00:00029 December 2015 13:00:00 Agreement State | ENS 413642005-02-01T22:00:0001 February 2005 22:00:00 Agreement State Agreement State Report - Nonlicensed Radiography Camera Confiscated by Us Customs in Florida 2020-09-04T04:00:00 [Table view] | ||