ENS 54548
From kanterella
Jump to navigation
Jump to search
ENS Event | |
|---|---|
05:00 Feb 24, 2020 | |
| Title | Medical Event - Hdr Underdose to Patient |
| Event Description | The following information was received from the state of Florida via E-mail:
[The licensee] reported to the BRC [Bureau of Radiation Control] on 25 Feb 2020, and e-mailed an incident report on 26 Feb 2020 at 1224 EST that on 24 Feb 2020 at 1315 EST an HDR [high dose rate] incident occurred to a patient receiving skin therapy. The patient was prescribed 7.5 Gray x 5 fractions, on five different parts of the left hand. On the first dose of the first fraction, it was observed that catheter numbers 1 - 15 were reversed, causing an underdose to the patient by 56.25 percent. No Authorized Users were exposed to the source or otherwise contaminated. Florida Incident Number: FL20-022 A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient. |
| Where | |
|---|---|
| Florida Bureau Of Radiation Control Weston, Florida (NRC Region 1) | |
| License number: | 3748-2 |
| Organization: | Florida Bureau Of Radiation Control |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+82.9 h3.454 days <br />0.493 weeks <br />0.114 months <br />) | |
| Opened: | Mark Seidensticker 15:54 Feb 27, 2020 |
| NRC Officer: | Donald Norwood |
| Last Updated: | Feb 27, 2020 |
| 54548 - NRC Website | |
Florida Bureau of Radiation Control with Agreement State | |||||
| Agreement State Report - Vehicle Carrying Radio-Pharmaceuticals Involved in Accident ENS 549092020-09-24T13:30:00024 September 2020 13:30:00 Agreement State | Agreement State Report - Lost/Stolen Troxler Gauge ENS 549262020-09-04T04:00:0004 September 2020 04:00:00 Agreement State | Agreement State Report - Leaking Sealed Source ENS 548022020-07-27T04:00:00027 July 2020 04:00:00 Agreement State Agreement State Report - Troxler Gauge on Ebay ENS 547992020-07-23T04:00:00023 July 2020 04:00:00 Agreement State Agreement State Report - Lost Shipment of I-125 Seeds ENS 547882020-07-17T04:00:00017 July 2020 04:00:00 Agreement State Agreement State Report - Underdose Administered to Patient ENS 547862020-07-16T04:00:00016 July 2020 04:00:00 Agreement State Agreement State Report - Medical Misadministration ENS 547822020-07-14T13:15:00014 July 2020 13:15:00 Agreement State Agreement State Report - Therasphere Procedure Underdose ENS 547632020-07-01T04:00:0001 July 2020 04:00:00 Agreement State Agreement State Report - Medical Event ENS 547432020-06-05T04:00:0005 June 2020 04:00:00 Agreement State Agreement State Report - Medical Event ENS 547172020-05-12T04:00:00012 May 2020 04:00:00 Agreement State Agreement State Report - Medical Event ENS 547032020-05-12T00:30:00012 May 2020 00:30:00 Agreement State Agreement State Report - Lost Gauge ENS 547042020-05-11T04:00:00011 May 2020 04:00:00 Agreement State Agreement State Report - Patient Underdose ENS 546842020-04-20T04:00:00020 April 2020 04:00:00 Agreement State Agreement State Report - Used Beverage Can (Ubc) Baled Aluminum Returned to Florida ENS 546182020-03-26T04:00:00026 March 2020 04:00:00 Agreement State Agreement State Report - Damaged Moisture Denisty Gauge Case ENS 545582020-03-02T21:30:0002 March 2020 21:30:00 Agreement State Agreement State Report - Source Failed to Retract ENS 545442020-02-24T18:15:00024 February 2020 18:15:00 Agreement State Agreement State Report - Patient Underdose ENS 545482020-02-24T05:00:00024 February 2020 05:00:00 Agreement State Medical Event - Hdr Underdose to Patient ENS 545832020-02-03T04:00:0003 February 2020 04:00:00 Agreement State Agreement State Report - Loss of Control of a Cs-137 Source ENS 545042020-01-31T05:00:00031 January 2020 05:00:00 Agreement State Gamma Alarm Fixed Radiation Portal Monitor ENS 544582019-12-30T05:00:00030 December 2019 05:00:00 Agreement State Agreement State Report - Unaccounted Material ENS 544552019-12-20T05:00:00020 December 2019 05:00:00 Agreement State Agreement State Report - Patient Underdose ENS 544392019-12-11T05:00:00011 December 2019 05:00:00 Agreement State Agreement State Report - Dose Delivered Less than Prescribed ENS 516262015-12-29T13:00:00029 December 2015 13:00:00 Agreement State | ENS 413642005-02-01T22:00:0001 February 2005 22:00:00 Agreement State Agreement State Report - Nonlicensed Radiography Camera Confiscated by Us Customs in Florida 2020-09-04T04:00:00 [Table view] | ||
Retrieved from "https://kanterella.com/w/index.php?title=ENS_54548&oldid=3086230"