ENS Event | |
|---|---|
23:44 Apr 19, 2018 | |
| Title | Unanalyzed Condition Related to Emergency Core Cooling Gas Accumulation Acceptance Criteria |
| Event Description | On April 19, 2018 at 1944 EDT, Watts Bar Nuclear Plant (WBN) determined that a preliminary analysis shows current acceptance criteria for gas accumulation in the WBN Unit 1 and Unit 2 Safety Injection System (SIS) and Residual Heat Removal System (RHRS) discharge piping may be non-conservative. The surveillances that check void values and allow venting of the systems are to be performed utilizing conservative criteria at more frequent intervals to ensure gas void volumes remain under acceptable limits. Additional analysis is being performed to determine final actions.
The NRC Resident Inspector has been notified. |
| Where | |
|---|---|
| Watts Bar Tennessee (NRC Region 2) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition | |
| Time - Person (Reporting Time:+1.18 h0.0492 days <br />0.00702 weeks <br />0.00162 months <br />) | |
| Opened: | Charles Broesche 00:55 Apr 20, 2018 |
| NRC Officer: | Thomas Kendzia |
| Last Updated: | Apr 20, 2018 |
| 53349 - NRC Website
Loading map... | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
Unit 2 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
WEEKMONTHYEARENS 569102023-12-28T16:29:00028 December 2023 16:29:00
[Table view]10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition ENS 565412023-05-25T17:45:00025 May 2023 17:45:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition of Emergency Diesel Generator ENS 538012018-12-20T05:00:00020 December 2018 05:00:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Containment Air Return Fan System Inoperable ENS 533492018-04-19T23:44:00019 April 2018 23:44:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition Related to Emergency Core Cooling Gas Accumulation Acceptance Criteria ENS 528502017-07-12T16:38:00012 July 2017 16:38:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition Related to Gdc-5 (General Design Criterion-5) for Dual Unit Operation ENS 519952016-06-08T19:26:0008 June 2016 19:26:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition That Could Potentially Degrade Plant Safety ENS 509602015-04-06T21:00:0006 April 2015 21:00:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition Due to Volume Control Tank Isolation Time Analysis Error ENS 508872015-03-13T15:00:00013 March 2015 15:00:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition ENS 505962014-11-05T18:10:0005 November 2014 18:10:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition Regarding Appendix R Procedures ENS 505402014-10-15T21:00:00015 October 2014 21:00:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Appendix R Unanalyzed Condition Affecting the Turbine Driven Aux Feedwater Pump ENS 502452014-07-01T02:46:0001 July 2014 02:46:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition That Could Have Resulted in an Increased Maximum Flood Level ENS 498182014-02-11T23:00:00011 February 2014 23:00:00 10 CFR 50.72(b)(3)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Nonconservative Operator Manual Actions Identified in Appendix R Analysis ENS 495412013-11-14T21:00:00014 November 2013 21:00:00 10 CFR 50.72(b)(3)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition, 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Postulated Fire Induced Failure of Centrifugal Charging Pumps ENS 493892013-09-27T16:45:00027 September 2013 16:45:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Calculation Error Resulted in Unanalyzed Condition for Appendix R Event ENS 480562012-06-29T14:28:00029 June 2012 14:28:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition Due to Increase in Probable Maximum Flood Level ENS 487232009-07-28T05:00:00028 July 2009 05:00:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition That Could Have Resulted in an Increased Maximum Flood Level 2023-05-25T17:45:00 | |