ENS 53004
From kanterella
Jump to navigation
Jump to search
ENS Event | |
|---|---|
12:37 Oct 9, 2017 | |
| Title | Unusual Event Declaration for Toxic Gas Spill |
| Event Description | At 0737 CDT on 10/9/17, Point Beach declared an Unusual Event with Emergency Action Level HU 3.1 due to report of toxic gas from a spill in a service building within the protected area. The spill is contained and cleanup operations are in progress. The spill was not in a contaminated area or vital area. The janitorial worker injured while mixing cleaning chemicals in a closet was taken to the hospital.
The licensee notified the NRC Resident Inspector. Notified DHS SWO, FEMA Operations Center, DHS NICC, FEMA NWC (email), DHS Nuclear SSA (email), and FEMA NRCC SASC (email).
Point Beach has terminated the Unusual Event at 0944 [CDT] on 10/9/2017. The Unusual Event condition is no longer warranted. The NRC Resident Inspector has been notified. Notified R3DO (Hills), NRR EO (King), IRD (Stapleton), DHS SWO, FEMA Operations Center, DHS NICC, FEMA NWC (email), DHS Nuclear SSA (email), and FEMA NRCC SASC (email). |
| Where | |
|---|---|
| Point Beach Wisconsin (NRC Region 3) | |
| Reporting | |
| Emergency class: | Unusual Event |
| 10 CFR 50.72(a) (1) (i), Emergency Class Declaration | |
| Time - Person (Reporting Time:+-3.37 h-0.14 days <br />-0.0201 weeks <br />-0.00462 months <br />) | |
| Opened: | Denny Smith 09:15 Oct 9, 2017 |
| NRC Officer: | Bethany Cecere |
| Last Updated: | Oct 9, 2017 |
| 53004 - NRC Website
Loading map... | |
Unit 1 | |
|---|---|
| Reactor critical | Not Critical |
| Scram | No |
| Before | Cold Shutdown (0 %) |
| After | Cold Shutdown (0 %) |
Unit 2 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
WEEKMONTHYEARENS 530042017-10-09T12:37:0009 October 2017 12:37:00
[Table view]10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Declaration for Toxic Gas Spill ENS 526272017-03-20T21:20:00020 March 2017 21:20:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Declared for Fire Alarm in Containment ENS 494332013-10-13T14:46:00013 October 2013 14:46:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration ENS 487222013-02-06T17:43:0006 February 2013 17:43:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Unusual Event - Loss of Offsite Power to Essential Buses for Greater than 15 Minutes ENS 478632012-04-26T02:06:00026 April 2012 02:06:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Alert Declared Due to Toxic Gas Build Up Following an Emergency Diesel Generator Test Run ENS 474782011-11-27T08:38:00027 November 2011 08:38:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Unusual Event Due to a Loss of Offsite Power During Switching Operations ENS 443362008-07-04T00:45:0004 July 2008 00:45:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Sodium Hypochlorite Leak ENS 439072008-01-15T20:15:00015 January 2008 20:15:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(a)(1)(i), Emergency Class Declaration, 10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown Unusual Event - Loss of Offsite Power ENS 429122006-10-17T02:26:00017 October 2006 02:26:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event - Identified Leakage Greater than 25 Gpm 2017-03-20T21:20:00 | |