| Title | Unanalyzed Condition Due to Not Meeting Single Failure Criteria |
| Event Description | At 1722 [EDT] on 8/17/16, a Past Operability Evaluation (POE) determined the configuration of the Emergency Gas Treatment System (EGTS) flow controllers that existed prior to 0420 on 8/6/16 constituted an Unanalyzed Condition due to not meeting single failure criteria. This POE examined the condition where EGTS may auto-swap from the flow control path in A-Auto to the Standby flow control path upon the start of a Design Basis Event (DBE). The intended design of the EGTS swap over flow control path in Auto to Standby was to detect and respond to an actual failure of the A-Auto flow control path. The unnecessary auto-swap to Standby could prevent the EGTS train configured in Auto from performing its required safety function during a DBE. The POE performed a detailed calculation to determine the release effects due to the failure of the redundant trains of EGTS controllers. These calculations concluded that failure of both trains of EGTS controllers would not result in exceeding the 10CFR100 limits, however this condition was unanalyzed and failed to meet single failure criteria.
This condition is reportable under 10CFR50.72(b)(3)(ii)(B), Unanalyzed Condition due to a system required to meet the single failure criterion does not do so. This condition had no impact to the health and safety of the public. The NRC Resident Inspector has been notified. |
| Where | |
|---|---|
| Sequoyah Tennessee (NRC Region 2) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition | |
| LER: | 05000327/LER-2016-007 Regarding Unanalyzed Condition Due to Emergency Gas Treatment System Not Meeting Single Failure Criteria |
| Time - Person (Reporting Time:+-3.6 h-0.15 days <br />-0.0214 weeks <br />-0.00493 months <br />) | |
| Opened: | Robert Urbanski 17:46 Aug 17, 2016 |
| NRC Officer: | Vince Klco |
| Last Updated: | Aug 17, 2016 |
| 52187 - NRC Website
Loading map... | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
Unit 2 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
WEEKMONTHYEARENS 544872020-01-22T03:18:00022 January 2020 03:18:00
[Table view]10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition ENS 521872016-08-17T21:22:00017 August 2016 21:22:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition Due to Not Meeting Single Failure Criteria ENS 519942016-06-08T19:26:0008 June 2016 19:26:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition That Could Potentially Degrade Plant Safety ENS 519352016-05-17T01:05:00017 May 2016 01:05:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition That Significantly Degrades Plant Safety ENS 518542016-04-07T19:07:0007 April 2016 19:07:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition - High Pressure Fire Suppression Isolated from Containment ENS 515272015-11-10T20:02:00010 November 2015 20:02:00 10 CFR 50.72(b)(3)(v)(B), Loss of Safety Function - Remove Residual Heat, 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition Due to Debris Dropped Into Reactor Cavity Equipment Pit ENS 502442014-07-01T02:46:0001 July 2014 02:46:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition That Could Have Resulted in an Increased Maximum Flood Level ENS 496902014-01-03T20:00:0003 January 2014 20:00:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Abgts Potentially Inoperable for Both Units Under Worst-Case Conditions ENS 485842012-12-13T00:14:00013 December 2012 00:14:00 10 CFR 50.72(b)(3)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Risk of Possible Flooding to Ercw Building During Design Basis Flood ENS 487252009-07-28T05:00:00028 July 2009 05:00:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition That Could Have Resulted in an Increased Maximum Flood Level ENS 448142009-01-28T19:25:00028 January 2009 19:25:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition Related to a Postulated Appendix R Fire Scenario 2020-01-22T03:18:00 | |
Retrieved from "https://kanterella.com/w/index.php?title=ENS_52187&oldid=420883"