On May 15, 2015, at about
2130 hours0.0247 days <br />0.592 hours <br />0.00352 weeks <br />8.10465e-4 months <br /> [EDT],
Maryland Emergency Management Agency (
MEMA) received an emergency notification from Stericycle located at 5800 Chemical Road, Curtis Bay [Baltimore],
Maryland 21226. Apparently the biohazardous waste service received
I-131 therapy waste from MedStar
Washington Hospital (NRC licensee in
Washington, D.C.). The waste was an immediate concern; temporarily closing the facility, with some
I-131 contamination of facilities. Surveys indicated hot spot contact readings as high as 30 mR/hr with areas of general contamination. A private radiation consultant, Radiation Service Organization (
RSO), was called and responded to the scene on 5/16/15. The area is being remediated and has now been reopened.
Maryland is investigating the incident.
Stericycle is not licensed to receive radioactive waste.