ENS 50968
ENS Event | |
|---|---|
10:30 Apr 8, 2015 | |
| Title | Reactor Coolant System Pressure Boundary Leakage Identified |
| Event Description | The following event description is based on information currently available. If through subsequent reviews of this event additional information is identified that is pertinent to this event or alters the information being provided at this time, a follow-up notification will be made via the ENS or under the reporting requirements of 10 CFR 50.73.
At approximately 0030 [MST] on April 7, 2015, while performing planned routine visual examinations of Unit 3 components, the differential pressure instrumentation nozzle on the suction side of the 2A reactor coolant pump (RCP) was observed to have white deposits that appeared to originate at the nozzle penetration. At this time, no additional indications of leakage have been identified for other inspected reactor coolant pressure boundary nozzles. Following insulation removal, the piping was examined by qualified engineering personnel. At 0330 [MST] on April 8, 2015, it was determined, based on isotopic analysis, that the white residue is consistent with reactor coolant system fluid. Technical Specifications Limiting Condition of Operation (LCO) 3.4.14 permits no reactor coolant system pressure boundary leakage and therefore, the discovery of leakage from the nozzle is a degradation of a principal safety barrier. This notification is being made for a degraded condition pursuant to the requirements of 10 CFR 50.72(b)(3)(ii)(A). The unit had been shutdown for its 18th refueling outage on 4/3/15 at 0000 [MST]. The NRC Resident Inspectors have been informed of this condition. |
| Where | |
|---|---|
| Palo Verde Arizona (NRC Region 4) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded | |
| LER: | 05000530/LER-2015-001 Regarding Leakage from Reactor Coolant Pump 2A Suction Pipe Instrument Nozzle |
| Time - Person (Reporting Time:+1.17 h0.0488 days <br />0.00696 weeks <br />0.0016 months <br />) | |
| Opened: | Fara J Oreshack 11:40 Apr 8, 2015 |
| NRC Officer: | Jeff Herrera |
| Last Updated: | Apr 8, 2015 |
| 50968 - NRC Website
Loading map... | |
WEEKMONTHYEARENS 567852023-10-09T22:07:0009 October 2023 22:07:00
[Table view]10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Reactor Coolant System Pressure Boundary Degraded ENS 523092016-10-20T01:30:00020 October 2016 01:30:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Safety Injection Piping Weld Flaw ENS 519102016-05-05T12:00:0005 May 2016 12:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded High Pressure Safety Injection Valve Bonnet Leakage Identified During Refueling Outage ENS 518612016-04-11T12:35:00011 April 2016 12:35:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Reactor Pressure Bounday Leakage ENS 509682015-04-08T10:30:0008 April 2015 10:30:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Reactor Coolant System Pressure Boundary Leakage Identified ENS 494162013-10-07T09:19:0007 October 2013 09:19:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Potential Reactor Coolant System Pressure Boundary Leakage Identified ENS 428862006-10-07T18:40:0007 October 2006 18:40:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Axial Indications Identified on Pressure Boundry ENS 417832005-06-17T18:00:00017 June 2005 18:00:00 10 CFR 21.21, 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Potential Degraded Condition Due to Pressurizer Heater Element Non-Conformance ENS 416292005-04-23T07:00:00023 April 2005 07:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Discovered Two Axial Indications on Inside Diameter of Reactor Vessel Head Penetration ENS 405562004-02-29T07:00:00029 February 2004 07:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Boric Acid Residue Found on Pressurizer Heater Sleeve ENS 405032004-02-03T22:35:0003 February 2004 22:35:00 10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown, 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Technical Specification Required Shutdown Due to Rcs Pressure Boundary Leakage ENS 397142003-03-29T11:00:00029 March 2003 11:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded 2023-10-09T22:07:00 | |