ENS 50502
ENS Event | |
|---|---|
05:24 Oct 1, 2014 | |
| Title | Partial Loss of Communications in Emergency Operations Facility and Joint Information Center |
| Event Description | At 0750 EDT on October 1, 2014, the Shift Manager was notified that site Information Technology (IT) personnel were being mobilized to investigate a potential voice and network loss at the Emergency Operations Facility (EOF) and Joint Information Center (JIC). Site IT personnel were notified by offsite IT resources at 0727 EDT on October 1, 2014 of the issue that was first identified by IT monitoring software at 0124 on October 1, 2014.
The site IT personnel that responded to the EOF and JIC reported to site Control Room and Emergency Preparedness (EP) personnel at 0845 that connectivity to the Exelon network and the internet was unavailable at both the EOF and the JIC. This loss of connectivity would prevent the ability of the EOF Emergency Response Organization (ERO) personnel to directly monitor key plant parameters via the site's Plant Process Computer (including the Site Parameter Display System) and other network-based plant parameter display systems. Site IT and EP personnel determined that the following communications equipment was not impacted by the connectivity issue: - Dedicated Offsite Agency Phones (primary method for contacting state and local agencies) - Commercial Phones and dedicated bridge line (primary method for contacting other site Emergency Response Facilities) - FTS-2001 Phones (e.g., ENS and HPN lines) - ERDS Additionally, EP personnel verified with Dose Assessment Office personnel that dose assessment and dose monitoring functions from the EOF could still be performed without delay. Site IT personnel reported to the Control Room at 1135 that connectivity to the Exelon network and the internet had been restored to a fully functional status. While site and fleet IT personnel continue to address and verify all appropriate corrective actions have been taken to prevent recurrence of the connectivity issue, the site has employed appropriate compensatory measures to ensure that the verbal transmission of key plant parameters from the site (Technical Support Center or Control Room) to the EOF is recognized and maintained. The NRC Resident Inspector has been notified.
This update retracts Event Report #50502, which reported that a loss of connectivity to the Exelon network and internet at the Emergency Operations Facility (EOF) and Joint Information Center (JIC) had impacted the ability of staff in these facilities to directly monitor key plant parameters via the site's Plant Process Computer and other network-based plant parameter display systems. Subsequent to the identification of this event, further investigation by site and fleet staff determined that adequate direction was included in applicable Emergency Response Organization (ERO) procedures to respond to data display system failures of this type. Specifically, the checklist (procedure) for the Operations Communicator in the EOF provided adequate direction for this ERO member to obtain required plant data from the Operations Communicator located in the Control Room via alternate methods (e.g., over the phone - phone lines remained functional throughout the time that the loss of computer connectivity condition existed). Therefore, this event did not result in a major loss of emergency assessment capability and was not reportable to the NRC under 10CFR50.72(b)(3)(xiii). The NRC Resident Inspector has been notified. Notified R1DO (Bickett) and Cyber Assessment Team via email. |
| Where | |
|---|---|
| Calvert Cliffs Maryland (NRC Region 1) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness | |
| Time - Person (Reporting Time:+9.72 h0.405 days <br />0.0579 weeks <br />0.0133 months <br />) | |
| Opened: | Kent Mills 15:07 Oct 1, 2014 |
| NRC Officer: | Dong Park |
| Last Updated: | Oct 27, 2014 |
| 50502 - NRC Website
Loading map... | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
Unit 2 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
WEEKMONTHYEARENS 563552023-02-06T11:30:0006 February 2023 11:30:00
[Table view]10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Communications and Assessment Capabilities ENS 515102015-11-02T14:20:0002 November 2015 14:20:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Radiation Monitoring Equipment Due to Planned Maintenance ENS 506872014-12-17T09:17:00017 December 2014 09:17:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Main Plant Vent Radiation Monitoring Unavailable ENS 505022014-10-01T05:24:0001 October 2014 05:24:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Partial Loss of Communications in Emergency Operations Facility and Joint Information Center ENS 487902013-02-27T20:38:00027 February 2013 20:38:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Planned Maintenance on Unit 2 Plant Process Computer ENS 487202013-02-06T14:00:0006 February 2013 14:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Planned Maintenance on Plant Process Computer ENS 486032012-12-18T19:36:00018 December 2012 19:36:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Partial Loss of Emergency Assessment During Planned Modifications ENS 483682012-10-03T12:00:0003 October 2012 12:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Technical Support Center Outage Due to Planned Maintenance ENS 482522012-08-29T23:30:00029 August 2012 23:30:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Primary Plant Computer Out of Service ENS 480872012-07-11T02:25:00011 July 2012 02:25:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Erds Due to Communications Network Module Failure ENS 480732012-07-06T06:32:0006 July 2012 06:32:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Emergency Response Data System Out of Service ENS 476992012-02-26T20:46:00026 February 2012 20:46:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Plant Assessment Capabilities Due to an Out of Service Plant Process Computer ENS 476842012-02-22T18:45:00022 February 2012 18:45:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Electrical Distribution System Maintenance to Impact Emergency Response Facilities ENS 476322012-02-03T13:22:0003 February 2012 13:22:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness ENS 472922011-09-26T18:00:00026 September 2011 18:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness 800 Mhz Radio System Temporarily Removed from Service Due to Degraded Antenna ENS 472072011-08-27T23:15:00027 August 2011 23:15:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Emergency Sirens Out-Of-Service ENS 465162010-12-29T13:15:00029 December 2010 13:15:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Scheduled Microwave Radio Maintenance Impact to the Ccnpp Control Room and Emergency Operations Facility ENS 464852010-12-16T13:00:00016 December 2010 13:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Planned Maintenance to Microwave Radio System Affecting Eof, State and County Facilities ENS 461082010-07-19T14:30:00019 July 2010 14:30:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Emergency Response Data System Discovered to Be Out of Service ENS 460682010-07-04T15:30:0004 July 2010 15:30:00 Other Unspec Reqmnt, 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Telephone Communications Outage ENS 457052010-02-16T05:00:00016 February 2010 05:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Scheduled Microwave Radio Upgrades Impact to the Control Room and Emergency Operations Facility ENS 453662009-09-20T05:30:00020 September 2009 05:30:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Emergency Sirens Inoperable ENS 450812009-05-19T19:00:00019 May 2009 19:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Emergency Response Data System (Erds) Computer Harddrive Out of Service ENS 448862009-03-02T16:35:0002 March 2009 16:35:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Weather Related Loss of Automatic Notification System Sirens ENS 448562009-02-17T15:00:00017 February 2009 15:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Safety Parameter Display System Due to Planned Maintenance ENS 433842007-05-24T15:00:00024 May 2007 15:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Emergency Operations Facility Out of Service for Planned Maintenance ENS 429532006-11-01T14:08:0001 November 2006 14:08:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Potential Degradation in the Offsite Emergency Siren Notification System ENS 413502005-01-23T17:00:00023 January 2005 17:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Emergency Notification Siren Capability Due to Loss of Power ENS 406622004-04-09T20:30:0009 April 2004 20:30:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Power to Eof ENS 401752003-09-19T01:05:00019 September 2003 01:05:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Emergency Siren Capability Due to Adverse Weather Conditions 2023-02-06T11:30:00 | |