The observed aging characteristics of the Solid State Relays on two particular Voter Relay Logic Cards Modules present a future challenge to the Power Range Neutron Monitoring System's ability to reliably insert the Average Power Range Monitor High-High/INOP
scram and/or the Oscillating Power Range Monitor
Scram to the
Reactor Protection System in plant conditions warrant such action.
For Relay Logic Cards that have been in operation for over 10 years, Relay Logic Card Module replacement should be scheduled and accomplished at the first reasonable opportunity.
For Relay Logic Cards in operation for less than 10 years, a program should be implemented to replace Relay Logic Card Modules before the 10 years is reached.
Plant affected; Nine Mile Point 2, Fermi 2, Grand Gulf, Limerick 1 & 2, Peach Bottom 2 & 3, Susquehanna 1&2, Brunswick 1 & 2, Hatch 1 & 2, Browns Ferry 1, 2, & 3, Monticello, and Columbia.