| Title | Agreement State Report - Contamination Levels Exceed Action Levels |
| Event Description | The following was received from the Commonwealth of Massachusetts via facsimile:
On Tuesday, 1/31/12, routine contamination surveys discovered approximately 0.5 nCi of Ir-192 outside of the restricted area on the first floor. The calculated dose for an 8-hour exposure to this RAM is 0.7 mrem. The contamination survey results prompted QSA to perform additional surveys to determine the source of contamination. Survey wipes yielded 10,000 to 30,000 dpm over large areas (approximately 2 feet x 2 feet) at different locations. Upon investigation, QSA discovered that the exhaust fan on the Ir-192 source production hot cell had been turned 'off.' The exhaust fan was immediately turned back 'on.' About one week earlier, Ir-192 from a supplier was transferred into the hot cell. This operation requires the hot cell exhaust fan to be turned 'off' temporarily. QSA realized that the exhaust fan had not been turned back 'on.' Radiation workers who performed hot cell production operations during the time the exhaust fan was 'off' were subjected to whole body counts performed at MIT. The whole body counts indicated workers ingested 12 to 20 nCi of Ir-192 and based on the MIT results, the RSO calculated the committed dose to be less than 2 mrem. Since the contamination discovery, QSA has performed cleaning operations on the first and second floors, daily survey monitoring of the first and second floors, and radiation workers performing production operations using the Ir-192 hot cell have worn full protective clothing suits. QSA reports daily surveys results indicate contamination levels have steadily decreased. Docket No: 14-0067 |
| Where | |
|---|---|
| Qsa Global Burlington, Massachusetts (NRC Region 1) | |
| License number: | 12-8361 |
| Organization: | Ma Radiation Control Program |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+555.47 h23.145 days <br />3.306 weeks <br />0.761 months <br />) | |
| Opened: | John Sumares 08:28 Feb 23, 2012 |
| NRC Officer: | Charles Teal |
| Last Updated: | Feb 23, 2012 |
| 47692 - NRC Website | |
Qsa Global with Agreement State | |
WEEKMONTHYEARENS 579092025-09-08T05:00:0008 September 2025 05:00:00
[Table view]Agreement State Transported Package Exceeds Limits ENS 573642024-10-04T16:44:0004 October 2024 16:44:00 Agreement State Missing Category 2 Source ENS 559162022-05-27T11:50:00027 May 2022 11:50:00 Agreement State Lost Sealed Sources in Transit ENS 551732021-04-05T14:40:0005 April 2021 14:40:00 Agreement State Sealed Source Missing in Transit ENS 549662020-10-22T13:26:00022 October 2020 13:26:00 Agreement State Missing Category 2 Material ENS 520952016-07-14T23:35:00014 July 2016 23:35:00 Agreement State Agreement State Report - Radioactive Material Delivered to Private Residence ENS 508052015-02-09T06:00:0009 February 2015 06:00:00 Agreement State Agreement State - Radioactive Shipment Delivered to the Wrong Location ENS 490112013-05-08T14:00:0008 May 2013 14:00:00 Agreement State Agreement State Report - Potentially Lost Radioactive Source Shipment ENS 490072013-05-06T12:00:0006 May 2013 12:00:00 Agreement State Agreement State Report - Source Shipment Did Not Arrive as Expected ENS 485132012-11-15T05:00:00015 November 2012 05:00:00 Agreement State Agreement State Report - Iridium-192 Source Missing During Shipment ENS 476922012-01-31T05:00:00031 January 2012 05:00:00 Agreement State Agreement State Report - Contamination Levels Exceed Action Levels ENS 462562010-09-02T19:59:0002 September 2010 19:59:00 Agreement State Agreement State Report - Source Received with External Contamination ENS 456212010-01-11T05:00:00011 January 2010 05:00:00 Agreement State Agreement State Report - Qsa Global Report of Defect ENS 445362008-10-03T04:00:0003 October 2008 04:00:00 Agreement State Agreement State Report - Defective Component That Could Potentially Cause a Substantial Safety Hazard ENS 439952008-02-19T05:00:00019 February 2008 05:00:00 Agreement State Agreement State Report - Radioactive Material Shipment Missing ENS 438612007-12-11T05:00:00011 December 2007 05:00:00 Agreement State Massachusetts Agreement State Report - Lost Shipment of Iridium-192 Sources 2025-09-08T05:00:00 | |