| Title | Alert Declared Due to Onsite Release of Fluorine/Chlorinated Fluorine Gas Mixture |
| Event Description | At 0415 CDT while changing out a cylinder of Fluorine/CL3 gas mixture in the C350 building, apparently a gasket failure occurred and an uncontrolled release of the gas mixture began. The licensee estimates that at the time the release began, there was approximately 160 lbs. of material in the cylinder. The release continues at this time. The C350 building was evacuated. There were no personnel injuries as a result of this event. No offsite assistance is being requested by the licensee. The local emergency squad is responding.
The licensee notified the NRC Resident Inspector.
The licensee believes, but has not verified at this time, that the gas leak has been stopped. A 'shelter in place' order has been issued for the following buildings: C337, C337a, C360, C335, C635 and C631. Samples exterior to building C350 are negative. Samples interior to building C350 still show residue and fog in the building. The licensee notified the NRC Resident Inspector.
The licensee has verified that the leak has been stopped.
At 0615 CDT, an employee that was involved with the cylinder change-out and response to the event was transported to the onsite medical facility. He was complaining of a burning sensation to his right arm. At 0625 CDT, samples obtained both inside and outside of building C350 were negative. The licensee notified the NRC Resident Inspector.
At 0631 CDT, the licensee has terminated the Alert. The licensee is controlling access to building C350 for investigation. The licensee has setup a recovery team. As a precautionary measure, a second individual that was involved in the cylinder change-out was also transported to the onsite medical facility. The licensee notified the NRC Resident Inspector. Notified R2DO (Blamey), NMSS EO (Habighorst), IRD MOC (Marshall), DHS (Arnold), FEMA (Hollis), DOE (Connally), EPA (Brett), USDA, and HHS (Jones).
On 7/27/11 at 0710 [CDT], the Paducah Gaseous Diffusion Plant decided to issue a press release describing the Alert issued by the plant earlier in the morning. The Alert issued on a chlorine trifluoride (CIF3) release in the C-350 facility was declared on 07/27/11 at 0415 [CDT] and terminated on 07/27/11 at 0631 [CDT]. . This event is reportable under Criteria P in Appendix D of USEC procedure UE2-RA-RE1030 as any event or situation, related to the health and safety of the public or on-site personnel, or protection of the environment, for which a news release is planned or notification to other government agencies has been or will be made. The NRC Senior Resident Inspector has been notified of this event. Notified R2DO (Blamey), NMSS EO (Habighorst) and PAO (Harrington). |
| Where | |
|---|---|
| Paducah Gaseous Diffusion Plant Paducah, Kentucky (NRC Region 2) | |
| License number: | GDP-1 |
| Reporting | |
| Emergency class: | Alert |
| 10 CFR 76.120(a)(4) Other Unspec Reqmnt | |
| Time - Person (Reporting Time:+-3.53 h-0.147 days <br />-0.021 weeks <br />-0.00484 months <br />) | |
| Opened: | Ken Wallace 05:43 Jul 27, 2011 |
| NRC Officer: | Donald Norwood |
| Last Updated: | Jul 27, 2011 |
| 47099 - NRC Website
Loading map... | |
Paducah Gaseous Diffusion Plant with Other Unspec Reqmnt, 10 CFR 76.120(a)(4) | |
WEEKMONTHYEARENS 495442013-11-17T20:17:00017 November 2013 20:17:00
[Table view]Other Unspec Reqmnt, 10 CFR 76.120(a)(4) Alert Due to Storm Damage on Site ENS 486802012-12-23T05:20:00023 December 2012 05:20:00 Other Unspec Reqmnt Minor Incidental Uranium Hexafluoride Release ENS 473072011-09-30T13:10:00030 September 2011 13:10:00 Other Unspec Reqmnt Hydraulic Leak Contained on Site- State Officials Notified ENS 470992011-07-27T09:15:00027 July 2011 09:15:00 Other Unspec Reqmnt, 10 CFR 76.120(a)(4) Alert Declared Due to Onsite Release of Fluorine/Chlorinated Fluorine Gas Mixture ENS 464872010-12-17T15:37:00017 December 2010 15:37:00 Other Unspec Reqmnt Diesel Fuel Oil Spill Contained on Site - Federal and State Officials Notified ENS 447762009-01-15T02:39:00015 January 2009 02:39:00 Other Unspec Reqmnt Ongoing Recirculating Cooling Water Leak at C337A Facility ENS 447442008-12-28T10:45:00028 December 2008 10:45:00 Other Unspec Reqmnt 24 Hour Report - Actuation of Leak Detection System Due to Minor Process Gas Leak ENS 446042008-10-27T07:39:00027 October 2008 07:39:00 Other Unspec Reqmnt Concurrent Notification to Nrc of Pcb Spill ENS 444482008-08-28T16:43:00028 August 2008 16:43:00 10 CFR 76.120(c)(2), Other Unspec Reqmnt Leak in High Pressure Fire Water System ENS 443102008-06-21T04:25:00021 June 2008 04:25:00 Other Unspec Reqmnt, Part 70 App A (C) Notification to Kentucky Ert Due to Exceeding Permit Limits at Outfall ENS 438642007-12-23T09:58:00023 December 2007 09:58:00 Other Unspec Reqmnt, 10 CFR 76.120(c)(1) Small Uf6 Process Leak ENS 438292007-12-07T02:44:0007 December 2007 02:44:00 Other Unspec Reqmnt, 10 CFR 76.120(c)(1) Unplanned Safety System Actuation and Contamination Event ENS 438282007-12-06T21:50:0006 December 2007 21:50:00 Other Unspec Reqmnt, 10 CFR 76.120(c)(1) Unplanned Safety System Actuation and Contamination Event ENS 437872007-11-15T15:15:00015 November 2007 15:15:00 Other Unspec Reqmnt Safety System Actuation Due to Incidental Uf6 Release ENS 436622007-09-25T05:05:00025 September 2007 05:05:00 Other Unspec Reqmnt Leaking Sulfuric Acid Tank ENS 433852007-05-24T13:15:00024 May 2007 13:15:00 Other Unspec Reqmnt Offsite Notification Made to Another Government Agency ENS 421442005-11-15T19:30:00015 November 2005 19:30:00 Other Unspec Reqmnt Reportable Incident Due to Deviation from Technical Specification Requirements ENS 414652005-03-06T17:40:0006 March 2005 17:40:00 Other Unspec Reqmnt Small Hydrogen Fluoride Leak 2013-11-17T20:17:00 | |