| Title | Reportable Incident Due to Deviation from Technical Specification Requirements |
| Event Description | At 1216 CST, on 11-15-05 the C-333, Unit 4, Cell 8, Process Gas Leak Detection (PGLD) system was declared inoperable by the Plant Shift Superintendent (PSS) in order to perform maintenance. Due to the inoperability of the system, a [Technical Specification Requirement] TSR required continuous smoke watch was put into place according to LCO 2.4.4.1. At 1330 CST a Tornado Warning was issued by the National Weather Service (NWS) for the area affecting the plant and surrounding area that remained in affect until 1400 CST. Based on the NWS warning, radar indications, and visual observations from on-site spotters, the PSS ordered the activation of the plants Take Cover Signal and [Public Address] PA announcements were made instructing the plant population to shelter in their designated 'take cover areas'. Upon activation of the Take Cover Signal, the individual performing the TSR required smoke watch at C-333, Unit 4, Cell 8, discontinued the smoke watch and reported to the 'take cover area' as required by plant emergency procedures. At this time, the PSS entered TSR 1.6.4, 'Conditions Outside TSR' due to discontinuing the TSR required smoke watch. TSR 1.6.4 requires that in an emergency, if a situation develops that is not addressed by the TSR, operations personnel should use their training and expertise to take actions to correct or mitigate the situation. In compliance with the TSR, the PSS instructed the Cascade Coordinator to reduce the operating pressure in the area affected by the Unit 4, Cell 8, PGLD outage, which would place the equipment in a non-applicable TSR mode of operation. Operating pressures were being reduced when the National Weather Service lifted the Tornado Warning at 1400 CST. At this time, the PSS lifted the Take Cover order and the TSR required smoke watch was put back into place at Unit 4, Cell 8 at 1405 CST. At this time the plant came into compliance with TSR LCO 2.4.4.1 and exited TSR 1.6.4.
This event is being reported under the requirements of TSR 1.6.4, 'If emergency action is taken, both a verbal and written notification shall be made in accordance with 10 CFR 76.120'. The NRC Senior Resident Inspector has been notified of this event. |
| Where | |
|---|---|
| Paducah Gaseous Diffusion Plant Paducah, Kentucky (NRC Region 2) | |
| License number: | GDP-1 |
| Reporting | |
| Other Unspec Reqmnt | |
| Time - Person (Reporting Time:+17.22 h0.718 days <br />0.102 weeks <br />0.0236 months <br />) | |
| Opened: | W.F. Cage 12:43 Nov 16, 2005 |
| NRC Officer: | John Knoke |
| Last Updated: | Nov 16, 2005 |
| 42144 - NRC Website
Loading map... | |
Paducah Gaseous Diffusion Plant with Other Unspec Reqmnt | |
WEEKMONTHYEARENS 495442013-11-17T20:17:00017 November 2013 20:17:00
[Table view]Other Unspec Reqmnt, 10 CFR 76.120(a)(4) Alert Due to Storm Damage on Site ENS 486802012-12-23T05:20:00023 December 2012 05:20:00 Other Unspec Reqmnt Minor Incidental Uranium Hexafluoride Release ENS 473072011-09-30T13:10:00030 September 2011 13:10:00 Other Unspec Reqmnt Hydraulic Leak Contained on Site- State Officials Notified ENS 470992011-07-27T09:15:00027 July 2011 09:15:00 Other Unspec Reqmnt, 10 CFR 76.120(a)(4) Alert Declared Due to Onsite Release of Fluorine/Chlorinated Fluorine Gas Mixture ENS 464872010-12-17T15:37:00017 December 2010 15:37:00 Other Unspec Reqmnt Diesel Fuel Oil Spill Contained on Site - Federal and State Officials Notified ENS 447762009-01-15T02:39:00015 January 2009 02:39:00 Other Unspec Reqmnt Ongoing Recirculating Cooling Water Leak at C337A Facility ENS 447442008-12-28T10:45:00028 December 2008 10:45:00 Other Unspec Reqmnt 24 Hour Report - Actuation of Leak Detection System Due to Minor Process Gas Leak ENS 446042008-10-27T07:39:00027 October 2008 07:39:00 Other Unspec Reqmnt Concurrent Notification to Nrc of Pcb Spill ENS 444482008-08-28T16:43:00028 August 2008 16:43:00 10 CFR 76.120(c)(2), Other Unspec Reqmnt Leak in High Pressure Fire Water System ENS 443102008-06-21T04:25:00021 June 2008 04:25:00 Other Unspec Reqmnt, Part 70 App A (C) Notification to Kentucky Ert Due to Exceeding Permit Limits at Outfall ENS 438642007-12-23T09:58:00023 December 2007 09:58:00 Other Unspec Reqmnt, 10 CFR 76.120(c)(1) Small Uf6 Process Leak ENS 438292007-12-07T02:44:0007 December 2007 02:44:00 Other Unspec Reqmnt, 10 CFR 76.120(c)(1) Unplanned Safety System Actuation and Contamination Event ENS 438282007-12-06T21:50:0006 December 2007 21:50:00 Other Unspec Reqmnt, 10 CFR 76.120(c)(1) Unplanned Safety System Actuation and Contamination Event ENS 437872007-11-15T15:15:00015 November 2007 15:15:00 Other Unspec Reqmnt Safety System Actuation Due to Incidental Uf6 Release ENS 436622007-09-25T05:05:00025 September 2007 05:05:00 Other Unspec Reqmnt Leaking Sulfuric Acid Tank ENS 433852007-05-24T13:15:00024 May 2007 13:15:00 Other Unspec Reqmnt Offsite Notification Made to Another Government Agency ENS 421442005-11-15T19:30:00015 November 2005 19:30:00 Other Unspec Reqmnt Reportable Incident Due to Deviation from Technical Specification Requirements ENS 414652005-03-06T17:40:0006 March 2005 17:40:00 Other Unspec Reqmnt Small Hydrogen Fluoride Leak 2013-11-17T20:17:00 | |
Retrieved from "https://kanterella.com/w/index.php?title=ENS_42144&oldid=1184382"