This report is made in accordance with 10 CFR 50.72(b)(3)(ii) as a condition resulting in a serious degradation of the Containment liner. During a visual inspection on 10/22/10, corrosion was found in the containment
sump liner on Unit 3, A more detailed inspection was performed on 10/24/10 after the corroded area was cleaned. Evaluation of the inspection results has determined that the corrosion is greater than allowed by the
ASME Code, including through wall areas, and requires repair. At this time, it is not known whether any leakage caused by the through-wall condition would have resulted in exceeding the containment allowed leakage limit. Unit 3 is currently in Mode 5 preparing to return to service following refueling. The corroded areas will be repaired prior to entering Mode 4.
The licensee notified the NRC Resident Inspector