ENS 45335
ENS Event | |
---|---|
04:00 Aug 14, 2009 | |
Title | Part 21 Involving Woodward Governors Using Unapproved Supplier Integrated Circuits |
Event Description | The following information was provided via fax:
COMPONENT: Woodward 2301A and DRU with unapproved supplier IC P/N: 9903-303, 9903-337, 9903-444 & 9903-470 DISCUSSION: Engine Systems Inc. (ESI) began a 10CFR21 evaluation on 8/14/09 to evaluate the use of an integrated circuit (IC) used in some 2301A and DRU controls. The suspect IC was obtained by Woodward from an unapproved supplier. The evaluation was concluded on 09/08/09 and was determined to be a reportable defect as defined by 10CFR21. On 8/14/09, Woodward confirmed that they had shipped ESI a total of thirty-four (34) 2301A and DRU controls with nuclear part numbers that contained an IC (Woodward P/N 1688-767) from a suspect lot. The lot was dated 12/12/08 and was received by Woodward from an unapproved supplier. Eight (8) of the 34 controls were subsequently shipped by ESI to nuclear customers (2 domestic plants and 3 foreign plants) before the issue was identified. To date, no operability issues have been reported or observed with 2301A and DRU controls containing the suspect IC. In the DRU, the IC is used in the raise-lower circuit and in the ramp time circuit (the ramp time circuit controls the ramp rate of the DRU). The DRU is primarily used as the speed reference input signal to the 2301A and provides remote speed adjustment for the 2301A (similar to the function of a motor operated potentiometer - MOP). In some applications, the DRU has also been used as a replacement for the voltage regulator MOP; in this case, the DRU provides the voltage adjustment signal to the voltage regulator. Failure of this IC could impact speed (frequency) control (and in some cases voltage control) of the EDG. In the 2301A, the IC is used in the start fuel limit circuit and in the speed signal input (magnetic pickup) circuit. The 2301A is the electronic governor used on many EDG's. It provides speed and/or load control of the diesel engine by communicating with the governor/actuator mounted on the diesel engine. Failure of this IC could impact speed (frequency) control of the EDG. AFFECTED USERS: Thirty-four (34) controls were shipped to ESI containing IC's from the suspect lot. Twenty-six (26) of the suspect controls were in ESI inventory and have been returned to Woodward to have the suspect IC replaced. ESI shipped eight (8) controls with suspect IC's to nuclear customers as safety related items as identified in the tables below. LISTING OF WOODWARD CONTROLS SHIPPED WITH SUSPECT IC's - (DOMESTIC PLANTS) McGuire - P/N # 9903-337, Customer PO # 00114776 Palo Verde - P/N # 9903-470 and # 9903-444, Customer PO # 500529186 LISTING OF WOODWARD CONTROLS SHIPPED WITH SUSPECT IC's - (FOREIGN PLANTS) Korea-KHNP - P/N # 9903-470, Customer PO # K080553241 Almaraz - P/N # 9903-470 and # 9903-337, Customer PO # 2009/015 - ER09AT06805MA KRSKO - P/N # 9903-303, Customer PO # NEK-10271/309 CORRECTIVE ACTION: The controls listed in the tables above should be returned to Engine Systems Inc. to have the suspect IC replaced as soon as possible. Contact ESI's Customer Service department with the part number and serial number of the control to be returned. |
Where | |
---|---|
Engine Systems, Inc Rocky Mount, North Carolina (NRC Region 1) | |
Organization: | Engine Systems, Inc |
Reporting | |
10 CFR 21.21 | |
Time - Person (Reporting Time:+634.83 h26.451 days <br />3.779 weeks <br />0.87 months <br />) | |
Opened: | Paul Stepantschenko 14:50 Sep 9, 2009 |
NRC Officer: | Steve Sandin |
Last Updated: | Sep 9, 2009 |
45335 - NRC Website | |
Engine Systems, Inc with 10 CFR 21.21, Notification of failure to comply or existence of a defect and its evaluation | |
WEEKMONTHYEARENS 476852012-02-17T05:00:00017 February 2012 05:00:00
[Table view]10 CFR 21.21, Notification of failure to comply or existence of a defect and its evaluation Missing Upper Mounting Pads on Subcover Assemblies ENS 476352011-12-01T05:00:0001 December 2011 05:00:00 10 CFR 21.21, Notification of failure to comply or existence of a defect and its evaluation ENS 454592009-08-24T04:00:00024 August 2009 04:00:00 10 CFR 21.21, Notification of failure to comply or existence of a defect and its evaluation Interim Report on Thermostatic Valve Failure on Palo Verde Edg ENS 453262009-08-17T04:00:00017 August 2009 04:00:00 10 CFR 21.21, Notification of failure to comply or existence of a defect and its evaluation Part 21 - Faulty Emergency Diesel Generator Start-Up Solenoid Valve ENS 453352009-08-14T04:00:00014 August 2009 04:00:00 10 CFR 21.21, Notification of failure to comply or existence of a defect and its evaluation Part 21 Involving Woodward Governors Using Unapproved Supplier Integrated Circuits 2012-02-17T05:00:00 | |