During a routine NRC inspection, the inspector questioned the adequacy of a 5-gallon limit on liquids allowed in certain process areas to prevent accidental nuclear criticality if the other controls in place are missing.
While further investigation is underway, this event is being reported per 10CFR70 Appendix (b)(1) on a conservative basis.
SAFETY SIGNIFICANCE: The safety significance is low
POTENTIAL CRITICALITY PATHWAYS: Liquid from 5-gallon container would have to spill and all enter normally closed equipment, or uranium dioxide powder spilled from the equipment.
CONTROLLED PARAMETERS: Controlled parameters are moderation
CORRECTIVE ACTIONS: A prohibition of spillable liquids exceeding 3-gallons was established in the affected areas.
The licensee will be notifying the NRC Region 2 Senior Inspector.