0520 hours0.00602 days <br />0.144 hours <br />8.597884e-4 weeks <br />1.9786e-4 months <br /> on 10/16/06 with the plant in Mode 6, with containment shutdown purge system in operation and
core alterations in progress, a Control Room Operator noted that Main Control Board
annunciator L-4 'Safeguard
DC Failure [Containment Isolation] CI and [Containment Ventilation Isolation]
CVI Logic' was illuminated.
ITS LCO 3.9.3 c. 2. requires that 'Each penetration providing direct access from the containment atmosphere to the outside atmosphere shall be either (1) closed by a manual or automatic isolation valve, blind flange, or equivalent, or (2) capable of being closed by an operable Containment Ventilation Isolation System.'
ITS LCO 3.3.5 Containment Ventilation Isolation Instrumentation Table 3.3.5-1 requires that Function 1, 'Automatic Actuation Logic and Actuation Relays' be operable during core alterations and movement of irradiated fuel assemblies within containment.
Contrary to the requirements DC power was removed from the Containment Ventilation Logic and Actuation Relays on Friday 10/13/06. On Saturday 10/14/06 reactor vessel head lift was performed. Between Sunday 10/15/06 from 1559 until Monday at 0514 the movement of fuel and core alterations in containment were conducted. All fuel movement and core alterations were stopped at 0514 on 10/16/06.
The licensee notified the NRC Resident Inspector.