ENS Event | |
|---|---|
19:29 Mar 11, 2005 | |
| Title | It Was Determineded That Greater than 1% of Inspected S/G Tubes Must Be Repaired. |
| Event Description | As part of the Cycle 6 refueling outage, inspections are being performed in accordance with Technical Specification (TS) 5.7.2.12, 'Steam Generator (SG) Tube Surveillance Program.' Based on a review of the inspection results to date, it was established at approximately 14:29 EST on March 11, 2005, that greater than 1 percent of the inspected SG tubes must be repaired. In accordance with the criteria stated in TS 5.7.2.12 and the inspection findings, the four SGs must be classified as C-3. The current inspection results do not meet the criteria specified for steam generator tube degradation in Revision 2 of NUREG 1022, 'Event Reporting Guidelines 10 CFR 50.72 and 10 CFR 50.73.' However, for the C-3 classification, WBN TS Table 5.7.2,12-1, 'SG Tube Inspection Supplemental Sampling Requirements,' requires that the results of the inspection be reported under 10 CFR 50.72. At this time, the submittal of a Licensee Event Report in accordance with 10 CFR 50.73 is not planned.
The NRC Resident Inspector was notified. |
| Where | |
|---|---|
| Watts Bar Tennessee (NRC Region 2) | |
| Reporting | |
| Other Unspec Reqmnt | |
| Time - Person (Reporting Time:+-2.38 h-0.0992 days <br />-0.0142 weeks <br />-0.00326 months <br />) | |
| Opened: | Joe Mayo 17:06 Mar 11, 2005 |
| NRC Officer: | Chauncey Gould |
| Last Updated: | Mar 11, 2005 |
| 41482 - NRC Website
Loading map... | |
WEEKMONTHYEARENS 476092012-01-17T22:46:00017 January 2012 22:46:00
[Table view]Other Unspec Reqmnt 24-Hour Report Per Section 2.G of Unit 1 Operating License ENS 468852011-05-14T18:28:00014 May 2011 18:28:00 Other Unspec Reqmnt Violation of License Condition ENS 468392011-05-09T19:18:0009 May 2011 19:18:00 Other Unspec Reqmnt Potential Valve Mispositioning Led to a Condition Prohibited by Technical Specifications ENS 458272010-04-08T04:00:0008 April 2010 04:00:00 Other Unspec Reqmnt Diesel Generators Wired Incorrectly ENS 453312009-09-08T01:20:0008 September 2009 01:20:00 Other Unspec Reqmnt Discovery of After-The-Fact Emergency Condition Unusual Event ENS 426902006-07-07T18:45:0007 July 2006 18:45:00 Other Unspec Reqmnt Alternative Report for Non-Declared Emergency Condition in Accordance with Nureg-1022 ENS 414822005-03-11T19:29:00011 March 2005 19:29:00 Other Unspec Reqmnt It Was Determineded That Greater than 1% of Inspected S/G Tubes Must Be Repaired. ENS 402002003-09-26T12:50:00026 September 2003 12:50:00 Other Unspec Reqmnt Greater than 1 Percent of Steam Generators 1,2 & 4 Tubes Inspected Indicate That the Inspected Tubes Require Plugging. 2012-01-17T22:46:00 | |
Retrieved from "https://kanterella.com/w/index.php?title=ENS_41482&oldid=428059"