14:41 Jan 26, 2004 | |
| Title | Unusual Event (Transitory) Due to Low Intake Bay Level Caused by Icing |
| Event Description | This is a notification of a transitory Notification of Unusual Event. Nine Mile Point Unit 1 experienced a transitory low intake bay level due to icing. This condition was resolved by shifting circulating water flow from reverse flow to normal flow. This met Emergency Action Level 8.4.3 for low fore bay level less than 238.8 feet. The duration of this event was from 0941 (EST) to 0943.
While returning reactor power to 100%, an unrelated problem [plant computer] halted power ascension at 92.4% [from a stable 90% reactor power]. The licensee notified the NRC Resident Inspector and the state and local government through their "warning point" emergency notification system. |
| Where | |
|---|---|
| Nine Mile Point New York (NRC Region 1) | |
| Reporting | |
| Emergency class: | Unusual Event |
| 10 CFR 50.72(a) (1) (i), Emergency Class Declaration | |
| Time - Person (Reporting Time:+-3.43 h-0.143 days <br />-0.0204 weeks <br />-0.0047 months <br />) | |
| Opened: | Fred Ringwald 11:15 Jan 26, 2004 |
| NRC Officer: | Arlon Costa |
| Last Updated: | Jan 26, 2004 |
| 40478 - NRC Website
Loading map... | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (90 %) |
WEEKMONTHYEARENS 537652018-12-02T05:00:0002 December 2018 05:00:00
[Table view]10 CFR 50.72(a)(1)(i), Emergency Class Declaration Alert Declared Due to Emergency Diesel Generator Damage ENS 531902018-02-01T16:08:0001 February 2018 16:08:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event - Fire in the Turbine Building Lasting Greater than 15 Minutes ENS 484332012-10-22T23:01:00022 October 2012 23:01:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Notification of Unusual Event Due to a Fire Greater than 15 Minutes ENS 480432012-06-21T19:05:00021 June 2012 19:05:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Declared Due to a Lagging Fire in a Feed Pump ENS 471292011-08-06T07:22:0006 August 2011 07:22:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration, 10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown Unusual Event and Plant Shutdown Due to Drywell Unidentified Leakage Greater than 10 Gpm ENS 469852011-06-25T11:55:00025 June 2011 11:55:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Declared Due to Fire Lasting Greater than 15 Minutes ENS 467042011-03-29T05:55:00029 March 2011 05:55:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Electrical Fire in the Drywell on a Piece of Lifting Equipment ENS 442062008-05-13T12:25:00013 May 2008 12:25:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.72(a)(1)(i), Emergency Class Declaration, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Unusual Event Declared Due to Loss of Offsite Power ENS 436522007-09-19T19:04:00019 September 2007 19:04:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Alert Declared Due to Inadvertent Discharge of Co2 Into Switchgear Room ENS 404782004-01-26T14:41:00026 January 2004 14:41:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event (Transitory) Due to Low Intake Bay Level Caused by Icing ENS 400662003-08-14T21:00:00014 August 2003 21:00:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Noue Was Declared at 1700 Due to Loss of Offsite Power ENS 400712003-08-14T20:35:00014 August 2003 20:35:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Declared Due to Loss of Offsite Power Greater than 15 Minutes. 2018-02-01T16:08:00 | |