DCL-23-009, Owners Activity Report for Unit 2 Twenty-Third Refueling Outage
| ML23053A251 | |
| Person / Time | |
|---|---|
| Site: | Diablo Canyon |
| Issue date: | 02/22/2023 |
| From: | Darrell Adams Pacific Gas & Electric Co |
| To: | Office of Nuclear Reactor Regulation, Document Control Desk |
| References | |
| DCL-23-009 | |
| Download: ML23053A251 (1) | |
Text
Pacific Gas and Electric Company"'
PG&E Letter DCL-23-009 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Docket No. 50-323, OL-DPR-82 Diablo Canyon Unit 2 Dallas L. Adams Manager, Program Engineering Owner's Activity Report for Unit 2 Twenty-Third Refueling Outage
Dear Commissioners and Staff:
Diablo Canyon Power Plant Mail code 104/41427 P.O. Box 56 Avila Beach, CA 93424 805.545.6182 Dallas.Adams@pge.com 10 CFR 50.4 In accordance with American Society of Mechanical Engineers (ASME)
Code Case N-532-5, enclosed is the Owner's Activity Report for inservice inspection (ISi) activities performed at Diablo Canyon Power Plant Unit 2 through the completion of the Unit 2 Twenty-Third Refueling Outage.
There are no new or revised regulatory commitments (as defined by NEI 99-04) in this submittal.
If you have any questions regarding the information enclosed, or other ISi program activities, please contact me at (805) 545-6182.
Sincerely, rntt/50942981-07 Enclosure cc/enc:
Mahdi 0. Hayes, NRC Senior Resident Inspector Samson S. Lee, NRC Senior Project Manager Robert J. Lewis, NRC Acting Region IV Administrator Diablo Canyon Distribution A
member of the STARS Alliance Callaway
- Diablo Canyon
- Palo Verde
- Wolf Creek
Enclosure PG&E Letter DCL-23-009 Diablo Canyon Power Plant Unit 2 Refueling Outage: 2R23 Operating License No. DPR-82 USNRC Docket No. 50-323 Owner's Activity Report, Rev. 0
==
Introduction:==
DIABLO CANYON POWER PLANT UNIT2 REFUELING OUTAGE: 2R23 Operating License No. DPR-82 USNRC Docket No. 50-323 OWNER'S ACTIVITY REPORT Rev. O Contents:
OAR-1 Report Number: DCPP-2R23:
Table 1:
Items with Flaws or Relevant Conditions That Required Evaluation for Continued Service.
Table 2:
Abstract of Repair/Replacement Activities Required for Continued Service.
Prepared By:
ex::
Terrance G. Carraher, ISi Program Owner Approved By:
Document Date: February 1, 2023 Pacific Gas and Electric Company 77 Beale Street, San Francisco, CA 94105 Diablo Canyon Power Plant P.O. Box 56, Avila Beach, CA 93424 Page 1 of 6 Internal Date -------
INTRODUCTION lnservice inspection (ISi) of scheduled ASME Section XI components and their supports at Pacific Gas and Electric Company's Diablo Canyon Power Plant (DCPP) Unit 2 was completed during the twenty-third refueling outage (2R23) from October 2022 through November 2022.
2R23 was the second outage in the second period within the fourth 10-year ISi interval.
This Owner's Activity Report, OAR-1, complies with the provisions of Code Case N-532-5 as approved by Regulatory Guide 1.147, Revision 20.
The OAR-1 Report covers any mid-cycle Section XI Repair/Replacement work closed-out after May 17, 2021, and any applicable 2R23 Section XI Repair/Replacement work closed-out prior to and including December 24, 2022.
Page 2 of 6 Internal
FORM OAR-1 OWNERS ACTIVITY REPORT -- DCPP-2823 Report Number DCPP-2R23 Plant -----'D=ia'""bc,.,lo"--"'C-"'a'-'n~yo"'n-'---'-'N"'u""c"'le""a"----r _,__P__,,o"'w'--"e"--r_,_P__,_,la"'n-'-'t,._, --'-P_,_..,,,O"-...,,B"'o~x..,,5""6"-,,_A,_,_v.,_,,ila"--"'B""e""a""c'-'-h,'-'C"'"""al"-'if-"-o'-'-rn"'ia,,__-"-9"'-34"'2,,_4.,__ _______ _
Unit No. _ _,2=-____
C,,_o""mc:..:..:..:m.,_,e"'"r-"-ci"'a"----I ""se"'rv-'-'-"ic,_,,e'-'d""a,_,_te,,___-'-M'""a""r--"c'-'h-'1--"3"-, _,_1-"'9-"-86,,____ Refueling outage no. __,2=-'R_,,2""3'--_
Current inspection interval IWB / IWC / IWD / IWF - 4th IWE / IWL -
3rd (1st, 2nd, 3rd, 4th, other)
Current inspection period IWB / IWC / IWD / IWF - 2nd IWE / IWL -
2nd (1st, 2nd, 3rd)
Edition and Addenda of Section XI applicable to the inspection plans _ _,IC!.W.,_,B""/""'C""'/D"--'/_.,_F_._2""0""'0""'7_E=-d"'--'-/=2-"-00"-'8"--'-'A""d"'-d __
IWE/IWL 2007 Ed / 2008 Add Date and revision of inspection plans IWB / IWC / IWD / IWF -- 9/30/2020 Rev. 1 IWE / IWL -4/4/2019 Rev. 0 Edition and addenda of Section XI applicable to repair/replacement activities, if different than the inspection plans No Difference Code Cases used:
N-532-5 N-722-1 N-731 N-666-1 N-770-5 (if applicable)
CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct; (b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI; and (c) the repair/replacement activities and evaluations supporting the completion of 2R23 (refueling outage no)
Date _
_ J.._-_?-_-_J._3 __ _
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in this Owner's Activity Report, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/replacement activities and evaluation described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Date -
~-----'--'!t'-"-'bfc......:
-z----===3 __
Page 3 of 6 Internal
FORM OAR-1 OWNERS ACTIVITY REPORT -- DCPP-2R23 TABLE 1 ITEMS WITH FLAWS OR REVELANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Examination Category and Item Number Item Description Evaluation Description None None None Page 4 of 6 Internal
FORM OAR-1 OWNERS ACTIVITY REPORT -- DCPP-2R23 TABLE 2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code Item Description Description of Work Date Repair/Replacement Class Completed Plan Number 1
71-57SL Replaced snubber with new snubber 10/20/2022 60141174-0010 1
LINE-1140 Repaired weld by weld overlay 11/8/2022 60148506-0010 1
RCS-2-RV-801 0A Install Rebuilt RV 11/4/2022 64168648-0200 1
RHR-2-8702 Replaced packing studs/nuts 12/12/2022 60136527-0300 2
2033-23SL Replace load pin 11/05/2022 60141251-0080 2
2033-23SL Fab / modify support 11/3/2022 60141251-01 10 2
MS-2-FCV-42 Replaced stud & nut 10/29/2022 60148512-0010 2
MS-2-1056 Replaced valve & associated piping by 11/1/2022 68065800-0020 welding 2
49-10R Cut out & reinstall support. No new 11/3/2022 68065800-0025 parts added, only rewelding 2
CVCS-2-8368B Replaced valve & associated piping by 11/30/2022 60148531-0010 welding 2
41 4-258ASL Replaced snubber with new snubber 10/26/2022 60141247-001 0 2
414-258BSL Replaced snubber with new snubber 10/26/2022 60141248-0010 3
414-73SL Replaced snubber with new snubber 10/18/2022 60141246-0010 3
CCW Hx 2-2 Replaced manway 11/2/2022 64197899-0035 3
CCW Hx 2-1 Replaced manway 10/24/2022 64198264-0350 3
MU-2-1555 Replaced valve disc 10/28/2022 64036910-0115 3
414-665R Installed shims by welding 11/30/2022 60148763-0020 Page 5 of 6 Internal
FORM OAR-1 OWNERS ACTIVITY REPORT -- DCPP-2R23 TABLE 2 (Cont'd)
ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code Item Description Description of Work Date Repair/Replacement Class Completed Plan Number 3
ASW Pp 2-2 Replaced pump 11/4/2022 64177020-0050 3
Diesel Gen 2-1 Replaced jacket water elbow 6/21/2021 60137380-0010 3
Diesel Gen 2-3 Replaced jacket water heater 7/18/2022 60140226-0040 3
Diesel Gen 2-3 Replaced jacket water couplings 6/9/2022 641 06847-01 00 3
Diesel Gen 2-1 Replaced temperature control valve &
6/21/2021 641 31902-0100 jacket water couplings 3
Diesel Gen 2-2 Replaced jacket water heaters 8/27/2022 64140147-0100 3
Diesel Gen 2-1 Replaced jacket water heaters 8/25/2022 64143851-0100 3
Diesel Gen 2-2 Replaced relief valve 9/21/2022 64207022-0100 3
Diesel Gen 2-3 Replaced relief valve 6/9/2022 64208043-0100 3
Diesel Gen 2-1 Replaced relief valve 8/25/2022 6420887 4-0100 Page 6 of 6 Internal
FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R22 thru 2R23 I certify that the (5/18/21 thru 12/24/22) activities represented by Repair/Replacement Plan number 6014117 4-0010 conform to the requirements of Section XI necessary lo place the item in service.
Edition and Addenda of Section XI used: -----=2'-"0-"'0.,_7__.E"'d'-'-its.cio,,,n~th,.,_r-"'o-"-u"'-gl,.._1 _,__2_,,0"'08,,__,_J\\"d"'cl"'e'--'-n-"-d~a- ____ ___ _____ _
(If applicable, including cases modified by Case N-532 and later revisions)
Date _
_ ~_-_7-~ --'J..._J __ _
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60141 174-0010
, and slate that, to the best ofmy knowledge and belief, the Owner has perfonned all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property da age or loss of any kind arismg from or connected with this inspection.
- # I
~
Commissions NB-15083 CA2184 Al / IS / 1-N-R
--L+inspector's 1gnature National l3oard, State, Province, and Endorsements Date _ ~--'---/ 1__,_b /_-z._3 _
Internal
FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIVICATE OF CONFORMANCE Post 2R22 thru 2R23 I certify that the (5/18/21 thru 12/24/22}
activities represented by Repair/Replacement Plan number 60148506-0010 conform to the requirements of Section X1 necessaiy to place the item in service.
Edition and Addenda of Section X1 used: _ __;2._,,0'-"0"-7_.Ec"d.._.i"'lieeo'-'-'n'-'t"'h~ro"'t"'lg,.,h-'----"'2-"0-"-08"----'--A""d"'d'-'e"-n'-"d"'a, _ _ _______ _ _ ___ _
Code Cases used for repair/replacement activities: -
-'-'N,__-6"'6"'6~-~I ~N~-5~3<-2,,__-_.,_5 _____________________ ___ _
(\\
(If applicable, including cases modified by Case N-532 and later revisions)
Signed _ __
~ ~~ ~ ---
Datc _
_ J_-_7-
_,___-_J_J _ _ _ __ _
Owner or Owner's designee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issu,ed by the National Board of Boiler ru1d Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60148506-0010
, and state that, to the best of my knowledge ru1d belief, the Owner has perfonned all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.
By signing this certificate neitl1er the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in ru1y manner for any personal injury or properly damage o loss of any kind arising from or connected with this inspection.
..'.::__~!c_~""---:':'.'.!:".!'cl~'.l'li!'-'---
Commissions _ _ _ __,_N..,.,B"-----'-1"'"'50"'8'-"3"---"""C""A
'--'----"2'-'-18,,__4.,__.!.cAJ"'--'-/- l,_,S'--'-'/ _,_1-_,_N~-=R,___ _ ______ _
National Board, State, Province, and Endorsements Internal
FORMNIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R22 thru 2R23 I certify that the (5/18/21 thru 12/24/22) activities represented by Repair/Replacement Plan number 64168648-0200 conform lo the requirements of Section XI necessary to place the item in service.
Edition and Addenda of Section XI used: _ __;=2=0=0~7~E=d=it=io=1~1 =tl=1r=o=u0gh=2=0=08~A=d=d=e=n=da= _ _ _______ ____ _
Code Cases used for repair/replacement activities: _ _ N'--'--"-5"-3,,_2~-5"------------------------ -----
n (If applicable, including cases modified by Case N-532 and later revisions)
Signed __ ~_v\\
__,..._~
- L--------~---------
Date __ ~_ -_f-_-_J_3 _ ___ _
Owner or Owner's designee CERTJFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 64168648-0200
, and state that, to the best of my knowledge and belief, the Owner has perfonned all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary lo place the item in service.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plar1. Furthermore, neither lhc Inspector nor his employer shall be liable in atl)' manner for any personal injury or proper!)'. damage r loss of any kind arising from or connected with this inspection.
-""--"-"!.,£--+a~=="""P:,c:_---- Commissions -------'N..,_,Bsc.-_,_1.,,_50,,,8,.,,3"--_,C""A"'--"2"-l "-84-'---"--'A,.,_l-'/_1,.,.S'--'-/ _,_l-_,_N.,_-.,_,R,__ _______ _
National Board, State, Province, and Endorsements Internal
FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R22 thru 2R23 I certify that the (5/18/21 thru 12/24/22) activities represented by Repair/Replacement Plan number 60136527-0300 conform to the requirements of Section XI necessary to place the item in service.
Edition and Addenda of Section XI used: _ __;2=0~0~7~E=d=it=io=n~th=r=o=u,,.g=h~2~0=0=8~A~dc=le=1=1c=la 0 _
Code Cases used for repair/replacement activities: -~N'---'-----5"'3,,_2,,_-~5'--------- ------------- ---- -----
(\\
(Tf applicable, including cases modified by Case N-532 and later revisions)
Signed _ ---'ct
..___..~\\J;v-----
e.__________________ Date __ ~_-_7--_ _ -_~_-3 ___ _
'-'ownerorowner's desig11ce CERTIFICATE OF JNSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60136527-0300
, and state that, to the best ofmy knowledge and belief, the Owner has perfonned all activities described in the Repair/Replacement Plan in accordance with the requirements ofScelion XI necessary to place the item in service.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in U1e Repair/Replacement Plan. Furthem10re, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage r loss of any kind arising from or connected with Lhis inspection.
__ _1.,1~~:.._b ;n..,~~k1:'.l.d---Commissions ___ __.,_N_,,13,_-_,_!"'50"-'8'-"3"---'C"'A--'-"2""'18><-4,..._,__,A"--l __,__/----'J"'S'-"/'-----'--l-_,__N,_-R,_,_ _______ _
National Board, State, Province, mid Endorsements Date ----=--
2-_,_
/ _I b--'---/z_s~-
Internal
FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R22 thru 2R23 I certify that the (5/18/21 thru 12/24/22) activities represented by Repair/Replacement Plan number 60141251-0080 conform to the requirements of Section XI necessary to place the item in service.
Edition and Addenda of Section XI used: _ _;2~0~0~7~E=*d=1~*t=io=n~t=h=r=ot=1g""l~1 =2=0=0=8~A~d=d=c=n=d=a,__ ________ ___ __ _
N -532-5 (If applicable, including cases modified by Case N-532 and later revisions)
Owner or Owner's dcsignce CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60141251-0080
, and state that, to the best ofmy knowledge and belief, the Owner has perfonned all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.
By signing this certificate neither the Inspector nor his employer makes,my warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthennore, neither the Inspector nor his employer shall be liable in any manner for any personal injury 01 properly damage or oss of any kind arising from or connected with this inspection.
. / J,.....,r1-*.u,,.
Commissions NB-1 5083 CA 2184 Al / JS / 1-N-R
~ecto;*'s Signatl National Board, State, Province, and Endorsements Date __
'7_,__L_/_,_/b,,.,/_7 __ ~~---
Internal
FORMNIS-2A REPAIR/REPLACEMENT CERTIFICATlON RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R22 thru 2R23 I certify that the (5/18/21 thru 12/24/22) activities represented by Repair/Replacement Plan number 60141251-0110 conform to the requirements of Section XI necessary to place the item in service.
Edition and Addenda of Section Xl used: -~2=0=0~7~E=d=il=io=1~1 =ll=u=o=u0gh=2=0=08~ A=d=d=e=n=d,,a __ ____ ______ _ _ _
Code Cases used for repair/replacement activities: ---"N_,_-~5""3'-"2'--,,_5 _ __________________ ______ _ _
n (If applicable, including cases modified by Case N-532 and later revisions)
Signed _
_ ~__,,_.~
_ __ Date _
_ 'l._-_7--_-_~_]..,,_ _ _ _
Owner or Owner's designee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by T he Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 601 41251-01 10
, and state that, to the best of my knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Date __
7-_L,_/_/ b_,_/_'2...._> _
Internal
FORM NIS::2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R22 thru 2R23 I certify that the (5/18/21 thru 12/24/22) activities represented by Repair/Replacement Plan number 60148512-0010 confonn to the requirements of Section XI necessary to place the item in service.
Edition and Addenda of Section XI used: _ _;2"'0c.s0c..c7_,E"'* d""i,.,,tt,_,* o=nc.ct=h~ro=t,,,1g,,,l"'-1 =2""0.,,,0.,,,8_,,A-"d""d""e""n,_,d""a'---------- ---- ~
Code Cases used for repair/replacement activities: -~N.,_-_,,5"'3"'2~-5"'---- - - ------------------- --
(If applicable, including cases modified by Case N-532 and later revisions)
Signed~
~
~
Date _
_ ~_- _f-_-_:J~3 __
Owner or Owner's dcsignce CERTIFICATE OF lNSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam lloilcl' Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60148512-0010
, and state that, to the best ofmy knowledge and belief, the Owner has perfonned all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plm1. Furthcm1ore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage r loss of any kind arising from or connected with this inspection.
Date-----'-~"---'-/ '~b 1---'---z '"$-<:.,____
Internal
FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R22 thru 2R23 I certify that the (5/18/21 thru 12/24/22) activities represented by Repair/Replacement Plan number 68065800-0020 confonn to the requirements of Section XI necessary to place the item in service.
Edition and Addenda of Section XI used: --=2"-0"-07-'--"'E'-"d"-'it,_,_,io"'n_,_,_,_th,_,_r"'"ot,,,1ge,.,l.,_1 _,,_
2,,_00,,_,8"---'--'A'-"d'-"d"'e,_,_nd,,,a~ _________ _ _ _ __ _
Code Cases used for repair/replacement activities: _ __,_N~-~5=3=2~-5~-----------------------
n (If applicable, including cases modified by Case N-532 and later revisions)
Signed _
_ CA
__,,,,.""\\f---....._
___ Dale _
_ l_-_f--_-_i_J _ ___ _
'""'owneroro~ dcsigncc CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 68065800-0020
, and slate that, to the best ofmy knowledge and belief, the Owner has perfom1ed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section X1 necessary to place the item in service.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furlhcm1ore, neither the Inspector nor his employer shal I be I iable in any manner for any personal injury or property damage or lo s of any kind arising from or connected with this inspection.
Datc __
"7-__ l_lb_,_/ z-=-----..5-c____
Internal
FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTJFICATE OF CONFORMANCE Post 2R22 thru 2R23 I certify that the (5/18/2 I thru 12/24/22) activities represented by Repair/Replacement Plan number 68065800-0025 conform to the requirements of Section XJ necessary to place the item in service.
Edition arid Addenda of Section XJ used: ----=2'-"0-"0-'-7 -"E=d,..,_it,_,_io,,,1,.,_1..,,,th.,_,r=o=u,,.gh,.,_,,2""0=08~A=d=d=e=n=d~a ___ ________ ___ _
Code Cases used for repair/replacement activities: _ __.,_N.,_--"5'-"3'-"2~-5"--------------------- -------
1 (1 (If applicable, including cases modified by Case N-532 and later revisions)
Signed _
---'--~-
=------
~
Datc _
_ J.._ -_7_-_~-----'3 _ _ _ _
Owner or Owner's designee CERTIFICATE OF lNSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National 13oard of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 68065800-0025
, and state that, to the best of my knowledge and belief, the Owner has pcrfom1ed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in m1y maimer for any personal injury or property damage o loss of any kind arising from or connected with this inspection.
Date _
-z_/ _,c
/b~/-==-
zs Internal
FORM NTS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R22 thru 2R23 I certify that the (S/18/21 thru 12/24/22) activities represented by Repair/Replacement Plan number 60148531-0010 conform to the requirements of Section XI necessary to place lhe item in service.
Edition and Addenda of Section XI used: ----"2"'0"'0-'--7--'E,,.,:d,_,_it,.,_i"-on"--"11.,_,11_,,*o"'u6g,.,_h-=2'-"0-"-0"-8-'-A-"d""d,.,c"'n""d.,,a __ ____________ _
Code Cases used for repair/replacement activities: ----'N__,_-~5'-=3'-"2'--"-5 _________________ ________ _ _
(If applicable, including cases modified by Case N-532 and later revisions)
Signed ___ 0\\
___,1.---_,-'-~'------- --- - --- ---- -
Date ___
J.._-_f_" _J_j __
Owner or Owner's designee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60148531-0010
, and state that, to the best of my knowledge and belief, the Owner has perfom1ed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary lo place the item in service.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any loss of any kind arising from or connected with this inspection.
Date_ L--+--/-'-'16~/_-z"--3 __
Internal
FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R22 thru 2R23 I certify that the (5/18/21 thru 12/24/22) activities represented by Repair/Replacement Plan number 6014124 7-0010 conform to the requirements of Section Xl necessary to place the item in service.
Edition and Addenda of Section XI used: -~2=0=0~7~E=**ct=i=ti=o=n~l=h=ro=u'"'g~1=1-=2-"0""0=8~A=d=d=e=n=d=a;__ ___ __________ _
Code Cases used for repair/replacement activities: _ _,_N..,_-....,5'-'3'-'2=---"5'----------- ----------- -------
(If applicable, including cases modified by Case N-532 and later revisions)
Signed ___
~-------- ---- -----------
1\\-7--l~
Date __________ ____ _
Owner or Owner's designee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of 13oiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60141247-0010
, and state that, to the best ofmy knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in U1e Repair/Replacement Plan. furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or oss of any kind arising from or connected with this inspection.
Date ~ -z~/~1 &_,_/l_3 _
Internal
FORM NIS-2A REP A IR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R22 thru 2R23 I certify that the (5/18/21 thru 12/24/22) activities represented by Repair/Replacement Plan number 601 41248-0010 conform to the requirements of Section Xl necessary to place the item in service.
Edition and Addenda of Section XI used: _ _;2,,0'-"0C1'7--'f"-:d,,_i'-"t'-'io'-"n'--'t"'h'-'-ro"-t,,.1g""h"--=2-"0-"0"-8-'-A-"'d"-'d"-'e"'-n'-'d"'a, _ _____ _ ___ ____ _
Code Cases used for repair/replacement activities: _ _,_N.,_--"5'-"3"'2'---5"------------ ---- ------- - - ---
f ()
(If applicable, including cases modified by Case N-532 and later revisions)
Signed _ __
~~
~ -----
Date ___ ).._-_7--_ _ -_J_.,3'-----
Owner or Owner's designee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60141248-0010
, and state that, to U1c best of my knowledge and belief, U1e Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. furthermore, neither the Inspector nor his employer shall be liable in any manner for any ss of any kind arising from or connected with this inspection.
Internal
FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R22 thru 2R23 I certify that the (5/18/21 lhru 12/24/22) activities represented by Repair/Replacement Plan number 60141246-0010 confonn lo the requirements of Section XI necessary lo place the item in service.
Edition and Addenda of Section XI used: _ _;2,.,,0'-"0C!.7_,E"'c"'li"ti"'o"'n'--'t"-'hr"'o"'u,,.g,.,l.,_1 =2,,,,0,,,,08"--'-A""d"'d"'e""n"'d"'a'---
Code Cases used for repair/replacement activities: _ _,_N.,_-_,,,5-"'3_.,.2~*5.,_ _________________ _ _ ______ _
(If applicable, including cases modified by Case N-532 and later revisions)
Signed ____ ~- =-- - - - - --------------
Date _
_ ~_-_?-_ -_ ?-
____,,)"------ -
Owner or Owner's designee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by T he Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60141246-0010
, and stale that, to the best of my knowledge and belief, the Owner has perfom1cd all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.
By signing this ce1tificate neither the Jnspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Fmthermorc, neither the Jnspector nor his employer shall be liable in any manner for any personal injmy or property damage or oss of any kind arising from or connected with this inspection.
Date _
_ ~_/J~h/_-z'3 __
Internal
FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R22 thru 2R23 I certify that the (5/18/21 tluu 12/24/22) activities represented by Repair/Replacement Plan number 64197899-0035 conform to the requirements of Section Xl necessary to place the item in service.
Ed it ion and Addenda of Sect ion Xl used: _ __e2,.,,0'-"0'...!.7_,E""d"'i'-'-l i'-'o"'n'--'t"'h"'ro"'t"'I g,,,h,__,.2,,.0,,;08,,_,_A.,,d,,.,d,,.,e,.,_n'-'d,.,,a'-----
Code Cases used for repair/replacement activities: _ _,_N.,_--"5"'3_,,2cc-5e._ _________________ _ _ ______ _
1 f'i. rn (If applicable, including cases modi~ d ~:
N~ 32;~ater revisions)
Signed ___ ~--'"--------- --~ --- ----------
Date ___ '\\
--=... __ 'r
____ _,)
Owner or Owner's designee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 64197899-0035
, and state that, to tl1e best ofmy knowledge and belief, tl1e Owner has performed all activities described in the Repair/Replacement Plan in accordance with tl1e requirements of Section XI necessary to place the item in service.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal mjury or property damage o?oss of any kind arising from or connected with this inspect10n.
__ _jee"""Jr,,c-_..,,,,...,_-=i,--¥'-"'J=---*--
-Commissions NB-15083 CA 2184 Al / IS / 1-N-R National Board, State, Province, and Endorsements Internal
FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R22 thru 2R23 I certify that the (5/18/21 thru 12/24/22) activities represented by Repair/Replacement Plan number 64198264-0350 confom1 to the requirements of Section XI necessary to place the item in service.
Edition and Addenda of Section XI used: _ ___,2=0~0~7~E=d=it=io=1~1 =th=r=o=u.e.g=h-=2,..,0=0=8'-'A-==d=de=1=1d=a"--- --------- ----
Code Cases used for repair/replacement activities: _ __,N'-'--'-5'--'3'-'2,._--=-5 _ _________________________ _
. (') ~ (} *
(If applicable, including cases modified by Case N-532 and later revisions)
Signed ___ _:~-==---
- --- -~--------- --
Date _
_ J_-_J-__ -_?---=J==------ --
Owner or Owner's designee CERTIFICATE OF INSERVICE INSPECTION l, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel lnspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Conncclicut have inspected the items described in Repair/Replacement Plan number 64198264-0350
, and state that, to the best ofmy knowledge and belief, the Owner has perfom1ed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section Xl necessary to place the item in service.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or I ss of any kind arising from or connected with this inspection.
---~~,L..._..t:,.;r__=~~{;:1,.>f---
Commissions ___
___,_N.,_.B""'-"-1£50.,,8,.,,3"-_,C,,_,A'-'-"2"-I 8"'4'--'-'Al"-'-/~l""S'--'-/ _,_1-:..cN-'-'-.,_,R~---- ----
National Board, State, Province, and Endorsements Dale _
_ "Z-_/~/ 6~/_
z..3_
Internal
FORM NIS-2A REP AIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTJFICATE OF CONFORMANCE Post 2R22 thru 2R23 I certify that the (5/18/21 thru 12/24/22) activities represented by Repair/Replacement Plan number 64036910-0115 conform to the requirements of Section Xl necessary to place the item in service.
Edition and Addenda of Section XI used: _ _,2,,_,0"-'0"-'7'---"'Ec,,d...,it,.,io"'n.,_,_.th,.,_r_,,o.,,u,,.g,.,_h--=2'-"0'-"0"'8c..,A---'--"-d"'-de""n"'d"'a, _____ _____ ____ _
Code Cases used for repair/replacement activities: __ N'---'-----5"-3"-2""*_,5'----------------------------- ---
(If applicable, including cases modified by Case N-532 and later revisions)
Signed ___
~-
= ------------------------
Date __
"_-_+_.,..._J_J _ _ _
Owner or Owner's dcsigncc CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 64036910-0115
, and state that, to the best of my knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section Xl necessary to place the item in service.
By signing this certificate neither the 1;1spector nor his employer makes any warranty, expressed or implied, conccming the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property dm iagc or ss of any kind arising from or connected with this inspection.
- --~~l,L------£>,1-<'.1,4,,C-~'¥'~---Commissions - --~NB-'-"'--*__,__1 "'50"-'8"'3~_,C"'A--'---"'2-'-'18"--4,.______,..,A"-l __,__/_,l""S'-/'-'-I-__,__N,_-,..,R~-- ------
National Board, State, Province, and Endorsements Date_,,Z,_/_f h~/_-z_ $ __
Internal
FORM NIS-2A REPAIR/REPLACEMENT CERTIFICA TJON RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R22 thru 2R23 I certify that the (5/18/21 thru 12/24/22) activities represented by Repair/Replacement Plan number 60148763-0020 conform to the requirements of Section XI necessary to place the item in service.
Edition and Addenda of Section XI used: ---"-2'-"0"'0'-'--7----'E"'d"--'i-'--'ti.,,_on"----"tl'-'-'11'-"*o"'uce,g,._,_h-=2'-"0"'0"-8.,_A.,.,d,,.,d,.,e"'n"'d"'a. _ _______ ____ _ _
Code Cases used for repair/replacement activities: _ ___,N...,_,-5""3"'2,__-=5 __________________________ _
, (\\ IZ ~
(If applicable, including cases modified by Case N-532 and later revisions)
Signed _
_ ~--="---
Date __ )._-_ +-__ -_J_,J=------
Owner or Owner's designee CERTIFICATE OF INSERVICE INSPECTION I, U1c undersigned, holding a valid commission issued by the National Board of 13oiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60148763-0020
, and state that, to U1e best of my knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.
By signing this certificate neiU1er the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, nciU1er the Inspector nor his employer shall be liable in any manner for any personal inj ss of any kind arising from or connected with this inspection.
Date _
_ -1..._~_/ b~/_z 2_> __
Internal
FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATIQl:-1 RECORD_
OWNER'S CERTIFICATE OF CONFORMANCE Post 2R22 thru 2R23 I certify that the _
/5/18/21 Ihm 12/24/22) activities represented by Repair/Replacement Plan number 64177020-0050 conform to the requirements of Section XI necessary to place the item in service.
Edition and Addenda of Section XI used: -----"-2,,,0"'0.,_7--"E"'d,.,_i,..,li""on,..,__,_,th"'1"'*o"'u.ogh"--"2"'0-"'0.,,_8_,_A.,_,d,,,d"e"'n""d.,,_a _ ____________ _
Code Cases used for repair/replacement activities: _ ___,N_,_-....,5"'3"'2,_-=5 _________________ _______
(If applicable, including cases modified by Case N-532 and later revisions)
Signed ___
~-"------- ---~------------
Date __ ~_ - _7-_ - _J_J __
Owner or Owner's designee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Companv of Connecticut have inspected the items described in Repair/Replacement Plan number 64177020-0050
, and state that, to the best ofmy knowledge and belief, U1c Owner has perfonned all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthennorc, neither the Inspector nor his employer shall be liable in any manner for any personal injurY. or property dam a e or loss of any kind arising from or connected with this inspection.
Internal
FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R22 thru 2R23 I certify that the (5/18/21 thru 12/24/22) activities represented by Repair/Replacement Plan number 60137380-0010 confonn to the requirements of Section XI necessary to place the item in service.
Edition and Addenda of Section XI used: -~2=0~0~7~E~d=it=io=1~1 =th=r~o=u=g=h~2~0~0=8~A~d=d=e1=1d=a 0 _
Code Cases used for repair/replacement activities: _ __,N'-'-'-5,..,3,..,2,,_-""5 _ _____________________ ___ _ _
(If applicable, including cases modified by Case N-532 and later revisions)
Signed_ ------'(A,.__~Qh Owner or Owner's designee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hal'lford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60137380-001 0
, and state that, to the best of my knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessaiy to place the item in service.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for ai1y personal injury or property damaoe or loss f any kind arising from or connected with this inspection.
---~~i,,."--IJJ~~~'JLL~-- Commissions ___
__,_NB'-"'----"15,,,.,0"'8""3~...,C..:.A,.=2,.,18""'4'--'A'-'-'-I.,_/_,I""S_,/__,_1-_._,N~-R'-'-----------
National Board, State, Province, and Endorsements Dale __
~_/~/6/_2_3 __
Internal
FORMNIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R22 tlm1 2R23 I certify that the (5/18/21 thru 12/24/22) activities represented by Repair/Replacement Plan number 60140226-0040 conform to the requirements of Section XI necessary to place the item in service.
Edition and Addenda of Section XI used: --"'2,.,,0.,,0_,__7_,E,,_,' d,,_,i"'ti"'o"'n-'t"-'h-'-'ro,,_,te,lg,.,h-'-"'2-"-0-"-08><..!-A..,d,..,d"-'e'-'-n'""d,.,,a. ____ ___ _______ _
Code Cases used for repair/replacement activities: _ _oN__,__-~5c.:3c.:2,_-"-5 _ _________________________ _
(If applicable, including cases modified by Case N-532 and later revisions)
Signed _ _
_ ~~
Date_ ~_- ---'-"7-_-_)~ 5~ --
Owner or Owner's designee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of 13oiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Co1111cctic11t have inspected the items described in Repair/Replacement Plan number 60140226-0040
, and state that, to the best of my knowledge and belief, the Owner has perfor111cd all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.
By signing this certificate neither the Inspector nor his employer 111akes any warranty, expressed or i111plicd, conceming the activities described in the Repair/Replace111cnt Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property da111age or oss of any kind arising fro111 or connected with this inspection.
___ __k'.!'.:::,)L--IC~~n!,IJ',~-
Commissions ___
_,__N=B~-~I 5=0=8=3~~C,.,_A-'-"-2.,_,18'"'4'----A~ I.,_/_,l=S_,/'--'--I--'-'N'""'-1"'Z _______ _ _
National Board, State, Province, and Endorsements Date _
--z.
h 6/ _z 5.c___
Internal
FORM N1S-2A REPAIR/REPLACEMENT CERTIFICA TIQN_RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R22 thru 2R23 I certify that the
/5/18/21 thru 12/24/22) activities represented by Repair/Replacement Plan number 64106847-0100 confom1 to the requirements of Section Xl necessary to place the item in service.
Edition and Addenda of Section XI used: _ __.,,2=0=0~7~E~d=it=io=1=1~th=r=o=u0gl=1~2=0=0=8~A=d=d=e=n=d=.a _ _______ _____ _
Code Cases used for repair/replacement activities: -
--'N'--'---'-5"'3'-'2"---"5 ___ _______________________ _
(If applicable, including cases modified by Case N-532 and later revisions)
Signed_v\\
~ :::....___ _
Date __
')._-_7_-._o1 _J Owner or Owner's designee CERTIFICATE OF INSERVICE INSPECTION l, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 64106847-0100
, and state that, to the best of my kno,vledge and belief, the Owner has perfonned all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any ss of any kind arising from or connected with this inspection.
Date _
_ "2-~//-=+6/_Z_S __
Internal
FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R22 thru 2R23 I certify that the (5/18/21 thru 12/24/22) activities represented by Repair/Replacement Plan number 64131902-0100 conform to the requirements of Section Xl necessary to place the item in service.
Edition and Addenda of Section Xl used: -~2=0~0~7~E=,d=it=i=or~1 ~tl=11~*o=u-c>g=h=2=0=0=8~A=d=d=e=n=d=a __ _ ______ _____ _
Code Cases used for repair/replacement activities: _ ___,N_,_-~5'-"3'-"2'--"-5 _________________________ _
1
()
/,.,.
(If applicable, including cases modi; d ~ y ;.a: ; )532 and later revisions)
Signed _____ ~---- --' ---------- --~ ---~ Date _______ ~ c....----- -
Owner or Owner's designee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement
- Plan number 64131902-0100
, and state that, to the best of my knowledge and belief, the Owner has perfonned all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal in*
.Joi.loss of any kind arising from 01 connected with this inspection.
___ -IA::.J!....l,L--ll.L.-"'14.M!~'-'-'---Commissions NB-15083 CA 2 184 Al / IS / 1-N-R National Board, Stale, Province, and Endorsements Internal
FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE. OF CONFORMANCE Post 2R22 thru 2R23 I certify that the (5/18/21 thru 12/24/22) activities represented by Repair/Replacement Plan number 64140147-0100 confonn to the requirements of Section XI necessary to place the item in service.
Edition and Addenda of Section XI used: -
~2=0~0~7~E=d=it=io=1~1 ~th=r~o=u=gl~1 =2~0~08~A=d=d=e=n=d~a _________ _____ _
Code Cases used for repair/replacement activities: -~N~-~5~3~2~-5~--------------------------
(Jf applicable, including cases modified by Case N-532 and later revisions)
Signed _____ ~------ ----------------
Date ---------------
Owner or Owner's designee CERTIFICATE OF INSERVICE INSPECTION I, U1c undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 64140147-0100
, and state that, to the best of my knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in U1e Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Internal
FOR!'Yl_NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R22 thru 2R23 I certify that the (5/18/21 thru 12/24/22) activities represented by Repair/Replacement Plan number 64143851-0100 confom1 to the requirements of Section XI necessary to place the item in service.
Edition and Addenda of Section XI used: _ ____,,2=0~0~7~E=d=i=li=on~th=1~*o=ucog=h~2=0=0=8~A~d=d=e=n=d=a. _____ ___ _____ _
Code Cases used for repair/replacement activities: _ __,N'"'--"-5"°3'""2~-~5 _______________________ ___ _
J n A (If applicable, including cases modified by Case N-532 and later revisions)
Signed _ __
~__::=---- ------------------
Date __ "_ -__ '7_ -_J--=)'-_* _ _ __ _
Owner or Owner's designee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by lhc National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 64143851 -0100
, and stale that, to the best of my knowledge imd belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Date_-'Z-_/~/1,/_2_3 __
Internal
FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R22 thru 2R23 I certify that the
{5/18/21 thru 12/24/22}
activities represented by Repair/Replacement Plan number 64207022-0100 conform to the requirements of Section Xl necessary to place the item in service.
Edition and Addenda of Section XI used: _ _;2=0~0~7~E=*:=d=it~io=n~t=h=r=ot=1g"'l,._1 =2=0~0=8~A~d=d=e=n~d=a,_~-------------
Code Cases used for repair/replacement activities: _ __,N'-'-'-5"-'3'-'2"---"-5 _ _ _____ ___________________ _
(If applicable, including cases modified by Case N-532 and later revisions)
Signed ___ zyL
~~-----------------------
Datc _
_ ?,_-_/-_,.._A___,,,J,,___ _ _
Owner or Owner's designee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Stearn Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 64207022-0100
, and state that, to the best ofmy knowledge and belief, the Owner has pcrfom1ed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section Xl necessary to place the item in service.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspcclor nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Date _
"'l-"--'-/--'-1 -'-
&/ _-z 3-'----_
Internal
FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R22 thru 2R23 I certify that the (5/18/21 thru 12/24/22) activities represented by Rcpair/Rcplaccmcnl Plan number 64208043-0100 conform to the requirements of Section XI necessary to place the item in service.
Edition and Addenda of Section Xl used: - ~2~0~0_7~E=d=i=ti=on~th=1~*o~u=g~h_2~0_0~8_A~d~d~e~n~d~a ______________ _
Code Cases used for repair/replacement activities: -~N~-5~3_2~-~5 __________________________ _
(If applicable, including cases modified by Case N-532 and later revisions)
Signed _
~..___------~-
Date ---------------
Owner or Owner's designee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board ofUoiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 64208043-0100
, and state that, lo the best of my knowledge mid belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.
By signing this certificate neither the Inspector nor his employer makes m1y warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in imy mmmer for m1y personal injury or property damage or loss of any kind arising from or connected with this inspection.
Date _
-z_/l_ft~/z~ 3 _
Internal
FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R22 Ihm 2R23 I certify that the (5/18/21 thru 12/24/22) activities represented by Repair/Replacement Plan number 6420887 4-0100 conform lo the requirements of Section XI necessary to place the item in service.
Edition and Addenda of Section XJ used: ---=2=0=0~7~E=c=lit=io=1=1 ~tl=
11=*o=u0gh~2=0~0=8~A=d=d~c=n=d"'"a _____________ _
Code Cases used for repair/replacement activities: -~N~*=5=3=2~*~5 _________________ _____ ____ _
(If applicable, including cases modified by Case N-532 and later revisions)
S igned ____
~-------------------~ ----
Date
~ - ]. ') J Owner or Owner's designcc CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 64208874-0100
, and state that, to the best ofmy knowledge and belief, the Owner has pcrfom1ed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XJ necessary to place the item in service.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthennore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or oss of any kind arising from or connected with this inspection.
Internal