DCL-21-055, Owners Activity Report for Unit 2 Twenty-Second Refueling Outage

From kanterella
(Redirected from DCL-21-055)
Jump to navigation Jump to search
Owners Activity Report for Unit 2 Twenty-Second Refueling Outage
ML21200A252
Person / Time
Site: Diablo Canyon Pacific Gas & Electric icon.png
Issue date: 07/19/2021
From: Gerfen P
Pacific Gas & Electric Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
DCL-21-055
Download: ML21200A252 (51)


Text

Paula Gerfen Site Vice President Diablo Canyon Power Plant Mail code 104/6/605 P.O. Box 56 Avila Beach, CA 93424 805.545.4596 Internal: 691.4596 Fax: 805.545.4234 A member of the STARS Alliance Callaway

  • Diablo Canyon
  • Palo Verde
  • Wolf Creek July 19, 2021 PG&E Letter DCL-21-055 U.S. Nuclear Regulatory Commission 10 CFR 50.4 ATTN: Document Control Desk Washington, D.C. 20555-0001 Docket No. 50-323, OL-DPR-82 Diablo Canyon Unit 2 Owner's Activity Report for Unit 2 Twenty-Second Refueling Outage In accordance with American Society of Mechanical Engineers (ASME) Code Case N-532-5, enclosed is the Owner's Activity Report for inservice inspection (ISI) activities performed at Diablo Canyon Power Plant Unit 2 through the completion of the Unit 2 Twenty-Second Refueling Outage.

Code Case N-532-5 was used as an alternative to the requirements of ASME Section XI, Article IWA-6000, as listed in Regulatory Guide 1.147, lnservice Inspection Code Case Acceptability, ASME Section XI, Division 1, Revision 19, and approved in accordance with 10 CFR 50.55a(b)(5).

There are no new or revised regulatory commitments (as defined by NEI 99-04) in this submittal.

If you have any questions regarding the information enclosed, or other ISI program activities, please contact Mr. Shannon Conner, Manager, Program Engineering, at (805) 545-6171.

Sincerely, Paula Gerfen dqmg/50942981-5 Enclosure cc/enc: Donald R. Krause, NRC Senior Resident Inspector Samson S. Lee, NRC Project Manager Scott A. Morris, NRC Region IV Administrator Diablo Canyon Distribution July 19, 2021 Date Pacilic Gas and Elecmc Company"'

PG&E Letter DCL-21-055 Enclosure Diablo Canyon Power Plant Unit 2 Refueling Outage: 2R22 Operating License No. DPR-82 USNRC Docket No. 50-323 Owner's Activity Report, Rev. 0

DIABLO CANYON POWER PLANT

==

Introduction:==

UNIT 2 REFUELING OUTAGE: 2R22 Operating License No. DPR-82 USNRC Docket No. 50-323 OWNER'S ACTIVITY REPORT Rev. 0 Contents:

OAR-1 Report Number: DCPP-2R22:

Table 1:

Items with Flaws or Relevant Conditions That Required Evaluation for Continued Service.

Table 2:

Abstract of Repair/Replacement Activities Required for Continued Service.

Prepared By:

~ahe,,

ISi Pmgcam Owoe, Date :Z-R-'-d /

Reviewed By:

~~

Date 1 -8'-2..1

---""~-S-ha-w-na-Griffin.lG~r~i i-n,-IS-1-Sp_e_ci-ali-st _____

Approved By: -.~-""------L--~_-_-_-_______ _

Shannon Conner, Manager Program Engineering Document Date: July 8, 2021 Pacific Gas and Electric Company 77 Beale Street, San Francisco, CA 94105 Diablo Canyon Power Plant P.O. Box 56, Avila Beach, CA 93424 Page 1 of 6

INTRODUCTION lnservice inspection (ISi) of scheduled ASME Section XI components and their supports at Pacific Gas and Electric Company's Diablo Canyon Power Plant (DCPP) Unit 2 were inspected during the twenty-second refueling outage (2R22) from March 2021 through April 2021.

2R22 was the first outage in the second period within the fourth 10-year ISi interval.

This Owner's Activity Report, OAR-1, complies with the provisions of Code Case N-532-5 as approved by Regulatory Guide 1.147, Revisiqn 19.

The OAR-1 Report covers any mid-cycle Section XI Repair/Replacement work completed after January 18, 2020 and any applicable 2R22 Section XI Repair/Replacement work completed prior to and including May 17, 2021.

Page 2 of 6

FORM OAR-1 OWNERS ACTIVITY REPORT -- DCPP-2R22 Report Number DCPP-2R22 Unit No.

2 Commercial service date March 13, 1986 Refueling outage no. __,2=R~2=2~

Current inspection interval ---'I-'-W~B~/ ~IW_,_C~/_,_IW~D~/~l_,_W~F_-_4~t~h ___ __,l-'-W~E~ / ~IW

_,_L~- -3~r~d _

(1st, 2nd, 3rd, 4th, other)

Current inspection period __

_,_IW~B'-'/_,l_,_W~C~ / ~IW_,_D~/_,_IW~F_-_2=n~d~ _ __

_,_IW~E~/_,l_,_W~Lc...-_1~s~t _

(1st, 2nd, 3rd)

Edition and Addenda of Section XI applicable to the inspection plans _ _,l_,_W""'B=/=C~/D=/~F.,___,2=0~0'-'-7-'E=d"-'-/ 2=0=0~8'-'A_,_d=d~--

IWE/IWL, 2007 Ed/ 2008 Add Date and revision of inspection plans IWB / IWC / IWD / IWF -- 9/30/2020 Rev. 1 IWE / IWL-4/4/2019 Rev. 0 Edition and addenda of Section X I applicable to repair/replacement activities, if different than the inspection plans No Difference Code Cases used: -----

--'-'N'-'-5=3=2c...-5=-'-N..,_-_,_7=06=--'1..I........C.N~-..,_7=3-',,;1 '-'-'N'--7,....,7....,0'--5=---------

(if applicable)

CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct; (b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI; and (c) the repair/replacement activities and evaluations supporting the completion of 2R22 (refueling outage no) conform to the requirements of Section XI.

Signed~/_.

I Manager, Program Engineering Owner or Owner's designee, Title Date _

_ 7_._-_,11:..,__-;}.;=-.:.,~------ - -

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in this Owner's Activity Report, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/replacement activities and evaluation described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any man perso al injury or property damage or a loss of any kind arising from or connected with this inspection.

I Date ______,_j.L......=

/ g'-L...-/=----cz --

Page 3 of 6

_FORM OAR-1 OWNERS ACTIVITY REPORT -- DCPP-2R22 TABLE 1 ITEMS WITH FLAWS OR REVELANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Examination Category and Item Number Item Description Evaluation Description Pressurizer Spray Line Code Case N-770-5 Line S6-15-4 SPL Successive exam C-1 Class 1 Weld Overlay No change in flaw size WI B-345/WI B-345(SE)(OL)

Pressurizer RV 801 0A Inlet Code Case N-770-5 Line S6-729-6 SPL Successive exam C-1 Class 1 Weld Overlay No change in flaw size WIB-369/WI B-369(SE) (OL)

Pressurizer RV 8010B Inlet Successive & ISi exam Code Case N-770-5 Line S6-728-6 SPL No change in flaw size C-1 Class 1 Weld Overlay WIB-423/WIB-423(SE) (OL)

Pressurizer RV 8010C Inlet Code Case N-770-5 Line S6-727-6 SPL Successive exam C-1 Class 1 Weld Overlay No change in flaw size WIB-359/WIB-359(SE) (OL)

Page 4 of 6

FORM OAR-1 OWNERS ACTIVITY REPORT -- DCPP-2R22 TABLE 2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code Item Description Description of Work Date Repair/Replacement Class Completed Plan Number Replaced by welding:

2 Line-570 Elbow-21, Plpe-13, Elbow-3, and Pipe-04/05/2021 60133322-0040 14 to first flange Replaced by welding:

2 Line-570 & Llne-576 Pipe-18, Elbow-1, and Tee-1 04/05/2021 60133322-0020 Replaced by welding:

2 Line-570 Degraded piping section 04/05/2021 60135944-0020 2

Llne-576 Welding to restore elbow thickness 07/27/2020 60129915-0050 and repair leak 2

Llne-570 Welding to restore pipe thickness 07/29/2020 60130160-0020 2

Line-570 Welding to restore pipe thickness 07/31/2020 60130124-0020 2

413-414R Pipe support clamp replaced 03/30/2021 60133322-0005 2

413-334R Installed by welding:

04/05/2021 60133322-0150 Pipe support sh ims 2

MS-2-101 9 Replace degraded parts 03/29/2021 60134325-0021 2

MS-2-1019 Replaced valve ring & bonnet 03/29/2021 60134325-0030 2

MS-2-PCV-20 Replaced Trimset (plug) 03/26/2021 60123979-0010 2

MS-2-PCV-20 Replaced Bonnet Stud 03/26/2021 60123979-0075 2

MS-2-PCV-22 Replaced Valve Plug 03/28/2021 60129808-0010 2

Line-72 &

Replaced by welding:

03/26/2021 60134808-0030 CVCS-2-8487 A Valve and associated piping 2

Accumulator 2-1 Replaced by welding:

03/26/2021 60135520-0020 Nozzle "D" & associated piping 2

Accumulator 2-1 Replaced by welding:

03/19/2021 60135582-0020 Piping from Nozzle "B" 2

Accumulator 2-1 Replaced by welding:

03/27/2021 60135582-0160 Nozzle "B" & associated piping Page 5 of 6

FORM OAR-1 OWNERS ACTIVITY REPORT -- DCPP-2R22 TABLE 2 (Cont'd)

ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code Item Description Description of Work Date Repair/Replacement Class Completed Plan Number 2

Accumulator 2-4 Replaced by weldin g:

0311912021 60135560-0010 Piping from Nozzle "C-1 B" 2

Accumulator 2-4 Replaced by welding:

03127121 60135560-0015 Nozzle "C-1 B" & associated piping 2

Sl-2-RV-8856A Replaced nozzle / RTS 09116/2020 60016997-0011 2

CCW-2-RV-52 Replaced nozzle / RTS 09/16/2020 60092871-0011 3

CCW HX 2-1 Replaced Corroded Manway cover 03/2412021 64168577-350 Replaced Manway cover that leaked 3

CCW HX 2-1 during Maintenance Verification 04/0812021 60136124-0100 Testing 3

CCWHX 2-2 Replaced Corroded Manway cover 0410412021 64168059-0035 3

404-25R Modify support, added item 16 by 0112612021 60130763-0050 welding 3

414-819R Repair support by welding 1011712020 60131924-0030 3

DIG 2-2 Replaced jacket water pump &

0310412021 64005103-0100 couplings 3

DIG 2-3 TCV-5 Replaced TCV-5 1210812020 64131994-0100 3

DIG 2-2 TCV-3 Replaced TCV-3 03/0212021 64139431-0100 3

SW-2-301 Replaced valve with spare 0711512020 64159867-0100 3

SW-2-303 Replaced valve with spare 0711612020 64159902-0100 3

SW-2-170 Replaced valve with spare 0210112021 64164879-0100 3

SW-2-34 Replaced valve with spare 0210212021 64165009-0100 3

MU-2-803 Replace bonnet bolting 05119/2020 60122244-0010 3

ASWPp 2-1 Replace packing studs using heat 0810612020 64221959-0300 3

ASWPp 2-1 Replace packing studs using heat 0210412021 64231256-0300 Page 6 of 6

FORM NIS-2A REPAIR/REPLACEMENT REFERENCE LIST 1 of 2 Repair/Replacement Plan Number Sys Class Order Op Functional Location (Header)

Operation short text Comments Revision Performed 03 2

60130160 0020 DC-2-03-P-P-LI N E-570 LINE-570: Weld Repair PIPE 13 Welding to restore pipe thickness 2Y22 07/29/2020 03 2

60130124 0020 DC-2-03-P-P-LINE-570 LINE-570: Weld Repair PIPE-14 Welding to restore pipe thickness 2Y22 07/31/2020 03 2

60129915 0050 DC-2-03-P-P-LINE-576 Welding to restore elbow thickness and repair leak Welding to restore pipe thickness 2Y22 07/27/2020 03 2

60130004 0010 DC-2-03-P-P-LI N E-570 Corrosion U2 AFW Line-570 TEE-1 Clean corrosion at tee 2Y22 07/26/2020 03 2

60130005 0010 DC-2-03-P-P-LINE-570 Corrosion U2 AFW Line-570 ELBOW-2 Clean corrosion at elbow 2Y22 07/26/2020 03 2

60130006 0010 DC-2-03-P-P-LINE-570 Corrosion U2 AFW Line-570 ELBOW-4 Clean corrosion at elbow 2Y22 07/26/2020 03 2

60130007 0010 DC-2-03-P-P-LINE-570 Corrosion U2 AFW Line 570 - ELBOW 5 Clean corrosion at elbow 2Y22 07/26/2020 03 2

60130080 0010 DC-2-03-P-P-LI NE-570 Corrosion U2 AFW Line 570 - ELBOW 3 Clean corrosion at elbow 2Y22 07/26/2020 03 2

60133322 0020 DC-2-03-P-P-LINE-570 Elbow1 - Tee1: Replace Piping Replace piping 2R22 04/05/2021 03 2

60133322 0040 DC-2-03-P-P-LlNE-570 Flng Elbw3 - Elbw21: Replace Piping Replace piping 2R22 04/05/2021 03 2

60135944 0020 DC-2-03-P-P-LINE-570 LlNE-570: Replace Degraded Pipe Replace degraded pipe segment 2R22 04/05/2021 03 2

60133322 0005 DC-2-03-P-P-LlNE-570 413-414R: R/R Pipe Clamp 4/ENG lnsp/Coat Pipe support clamp replaced 2R22 03/30/2021 03 2

60133322 0150 DC-2-03-P-P-LINE-570 413-334R: Restore Configuration Installed pipe support shims 2R22 04/05/2021 04 2

60134325 0021 DC-2-04-P-V-MS-2-1019 MS-2-1019: Replace Degraded Parts Replace degraded valve parts 2R22 03/29/2021 04 2

60134325 0030 DC-2-04-P-V-MS-2-1019 MS-2-1019: Replace BonneUSpacer Ring Replace bonnet & ring 2R22 03/29/2021 04 2

60123979 0010 DC-2-04-P-V-MS-2-PCV-20 MS-2-PCV-20: Replace Trimset Replaced Trimset (plug) 2R22 03/26/2021 04 2

60123979 0075 DC-2-04-P-V-MS-2-PCV-20 MS-2-PCV-20: Replace Step Stud Replaced step stud 2R22 03/26/2021 04 2

60129808 0010 DC-2-04-P-V-MS-2-PCV-22 MS-2-PCV-22: Rebuild Valve Replace Valve Plug (in trimset) 2R22 03/28/2021 08 2

60134808 0030 DC-2-08-P-V-CVCS-2-8487 A CVCS-2-8487A: Replace Valve Replace valve and adjacent pipe 2R22 03/26/2021 09 2

60135582 0020 DC-2-09-M-TK-AT1 Accum 2-1 Naz B: Rmv/Rplc Piping(grind)

Remove/Replace piping for Nozz.

2R22 03/19/2021 09 2

60135582 0160 DC-2-09-M-TK-AT1 Accum 2-1: Replace Nozzle "B" Replace Nozzle B 2R22 03/27/2021 09 2

60135520 0020 DC-2-09-M-TK-AT1 Accum 2-1 D Nozzle/Pipe Replacement Replace Nozzle D & pipe 2R22 03/26/2021 09 2

60135560 0010 DC-2-09-M-TK-AT4 Accum 2-4 C-1 B: Rmv/Rplc Piping(grind)

Remove/Replace piping for Nozz.

2R22 03/19/2021

EQBM NIS-28 REPAIBLBEPLACEMEl:'-JT BEEEBENCE LISI I 2 of 2 09 2

60135560 0015 DC-2-09-M-TK-AT 4 Accum 2-4: Replace C-1 B Nozzle Replace Nozzle C-1 B 2R22 03/27/2021 09 2

60016997 0011 DC-2-09-P-VR-Sl-2-RV-8856A 0952938: Replace Nozzle (Sl-2-RV-8856A)

Replaced nozzle / RTS 1P22 09/16/2020 14 2

60092871 0011 DC-2-14-P-VR-CCW-2-RV-52 0952938: Replace Nozzle (CCW-2-RV-52)

Replaced nozzle / RTS 1P22 09/16/2020 14 3

60130763 0050 DC-2-14-P-PSL-404-25R 404-25R: Implement MMD M*51-1 Add item 16 to support 01 01 /26/2021 14 3

64168577 0350 DC-2-14-M-HX-CCWHE1 CCWHX 2-1: ASME XI Replace Manway Replace manway cover assembly 2C22 03/24/2021 14 3

601 36124 0100 DC-2-14-M-HX-CCWHE 1 CCWHX 2-1 : Replace Manway Assembly Replace manway cover assembly 2R22 04/08/2021 14 3

64168059 0035 DC-2-14-M-HX-CCWHE2 CCWHX 2-2: ASME XI Replace Manway Replace manway cover assembly 2C22 04/04/2021 16 3

60122244 0010 DC-2-1 6-P-V-MU-2-803 MU-2-803: Repack/ Rebuild Valve Replaced bonnet studs D1 05/19/2020 17 3

64221959 0300 DC-2-17-M-PP-ASP1 ASP2-1 : Rplc Pkng Glnd Studs/Nuts Replace packing studs using heat D1EO 08/06/2020 17 3

64231256 0300 DC-2-17-M-PP-ASP1 ASP2-1 : Rplc Pkng Glnd Studs/Nuts Replace packing studs using heat D1EO 02/04/2021 17 3

64159867 0100 DC-2-17-P-V-SW-2-301 SW-2-301 : INSPECT & REPLACE VALVE Replace valve with spare D1MX 07/15/2020 17 3

64159902 0100 DC-2-17-P-V-SW-2-303 SW-2-303: INSPECT/ REPLACE VALVE Replace valve with spare D1MX 07/1 6/2020 17 3

64164879 0100 DC-2-17-P-V-SW-2-170 SW-2-170: INSPECT / REPLACE< ASW2-1 >

Replace valve with spare 01MD 02/01 /2021 17 3

64165009 0100 DC-2-17-P-V-SW-2-34 SW-2-34: INSPECT / REPLACE < ASW2-1 >

Replace valve with spare D1MD 02/02/2021 21 3

60131924 0030 DC-2-21 -M-TB-TDE2 Weld Repair Suppt Brkt 414-819R Weld repair support member 2222 10/17/2020 21 3

64005103 0100 DC-2-21-M-EN-DEG2 DG22: STP M-21-ENG.8 Replace JW pump & couplings D1EO 03/04/2021 21 3

64131994 0100 DC-2-21-P-V-DEG-2-TCV-5 TCV-5: Replace Valve M-21-TCV.3 DG23 Replace TCV-5 01EO 12/08/2020 21 3

64139431 0100 DDC-2-21-P-V-DEG-2-TCV-3 TCV-3: Replace Valve M-21-TCV.3 DG22 Replace TCV-3 D1EO 03/022021

FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R21 thru 2R22 I certify that the

{0 l /19/20 thru 05/17/21) activities represented by Repair/Replacement Plan number 60130160-0020 confom1 to the requirements of Section X1 necessary to place the item in service.

Edition and Addenda of Section XI used: __

2~0~0~7~E=d=i=ti~o=n~t=h~ro=u=g=h~2=0~0~8~A=d=d~e=n=d=a __________ ___ _

Code Cases used for repair/replacement activities: ----"N~-5=3=2=-~5~------------------ ----- ----

(If applicable, including cases modified by Case N-532 and later revisions)

Sign~

Owner or Owner's dcsignee Date 7 -~ -.J..., \\

--~- ---~- ----- -

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60130160-0020

, and state that, to the best ofmy knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section X1 necessary lo place the item in service.

13y signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. FurU1ennore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damag or loss of any kind arising from or connected with this inspection.

.FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION REC.Q.l{Q OWNER'S CERTIFICATE OF CONFORMANCE Post 2R21 Ihm 2R22 I certify that the (01119/20 thru 05/17/21) activities represented by Repair/Replacement Plan number 60130124-0020 conform to the requirements of Section X1 necessary lo place the item in service.

Edition mid Addenda of Section XI used: -~2~0~0~7~E=d=1=*1:1~* o=n~t=h.t~*o=u=g=h~2~0~08~/\\.=d~d~c=n=d=a-- - - - ------ - -~

Code Cases used for repair/replacement activities: --'N~-5~3~2~-~5 _ ___________________ ______ _ _

Sig11ed~

(If applicable, including cases modified by Case N-532 and later revisions)

Owner or Owner's designcc CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60130124-0020

, and state that, to the best ofmy knowledge and belief, the Owner has pcrfonned all activities described in the Repair/Replacement Plan in accord mice with the requirements of Section XI necessary to place the item in service.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. FurU1ermore, neither the Inspector nor his employer shall be liable iu any numncr for any personal inju,y or property danu c or loss of any kind arising from or connected with this inspection.

FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORQ OWNIW.'S CERTIFICATE OF CONFORMANCE Post 2R21 thru 2R22 I certify that the (01/19/20 thru 05/17/21) activities represented by Repair/Replacement Plan number 60129915-0050 conform to the requirements of Section XI necessary to place the item in service.

Edition and Addenda of Section Xl used: -

~ 2~0~0~7~"=~d=i=ti=o=n~t=h=ro=u-g=h~2~0=0=8~A=d~d~c=n~d~a. ___ ___ _____ _ _ _

Code Cases used for repair/replacement activities: ------'N~-5=3=2=-~5~-- ----

(If applicable, including cases modified by Case N-532 and later revisions)

Signed~-"---

Date _~7-_Y~-J.,,"---"--'"\\ _ ____ _

Owner or Owner's designcc CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Insr>cction and l11S1Lrancc Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60129915-0050

, and state that, to the best ofmy knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthennore, neither the Inspector nor his employer shall be liable in any manner for any or loss of any kind arising from or connected with this inspection.

Dare_1_h~h~'--

,FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R2I thru 2R22 I certify that the (01/19/20 thru 05/17/21) activities represented by Repair/Replacement Plan number _ ___,6,,,0'--'l=-3-"-00=0e...4,_-=00=l~0'--

confonn to the requirements ofSeetion XI necessary to place the item in service.

Edition and Addenda of Section XI used: ---=2=0~0~7~E=** d='=* t1=

  • o=n~t=h~ro=u,,,g"'l~1 =2=00=8"-'--A=d=d=e=n=d=a _ _ ______ _____ _

Code Cases used for repair/replacement activities: __

N_-5_3_2_-_5 ____________________________ _

(If applicable, including cases modified by Case N-532 and later revisions)

Sign~~"--/

Owner or Owner's designee Date _ ~7_-~K~-,,_J.,__,,_,\\,_, ___ __ _

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection nnd Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60130004-0010, and state that, lo the best ofmy knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.

13y signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthem10re, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damag or loss of any kind arising from or connected with this inspection.

__J~~'1'-_µ__y~~~!'l[__J. _

_ __ Commissions ___ __,_N=B'----'-'15,,_.,0~8=3~~C=A_._2""1,___,8'----'4._____;A_,_l~/ '""IS,,_' _,_/_J,_-N,..,_,-R.,,_ _ ____ __ _

National Board, State, Province, and Endorsements

  • 1/e/2-1 Date _________ ___ _

FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R2 l Ihm 2R22 I certify that the (01/19/20 thru 05/17/21) activities represented by Repair/Replacement Plan number 60130005-0010 conform to the requirements of Section XI necessary to place the item in service.

Edition and Addenda of Section XI used: -~2~0~0~7~E=d=i=ti~o~n~th~r~o~u=g~h~2=0~0~8~A~dd=e=n~d=a~------ ----- --- --

Code Cases used for repair/replacement activities: -~N~--=-5-=-3=2~-5~ -------

{lf applicable, including cases modified by Case N-532 and later revisions)

~

Signed

,c:::::::::..__.

Owner or Owner's designee Date _ ___,.?~--=-¥"_-_)...~\\ _____ _

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement _Plan number 60130005-0010, and state that, to the best of my knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any or loss of any kind arising from or connected with this inspection.

Date _-,~/_g /~c_l __ _

FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R21 thru 2R22 I certify that the (01/19/20 thru 05/17/2 1) activities represented by Repair/Replacement Plan number 60130006-001 0 conform to the requirements of Section XI necessary to place the item in service.

Edition and Addenda of Section XI used: -~2=0~0~7~E=d=i=ti~on~lh~r~o~u=g~h~2=0=0=8~A~dd=e=n~d=a~-----------------

Code Cases used for repair/replacement activities: _ __,N..;.-~5=3=2~--=5 _ _______________________ _ _

Signed~ L----

~ner or Owner's designee (If applicable, including cases modified by Case N-532 and later revisions)

Date _

_ 7_.__- __.lf.._~ -_,t).._"--'--'\\.__ _

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 660130006-001 O

, and state that, to the best of my knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage /r loss of any kind arising from or connected with this inspection.

~ ~

Comm;ss;oa, NB-15083 CA2184 Al/ IS/ 1-N-R nspector's Signture National Board, State, Province, and Endorsements Date _

_ r-=-/_8'--'/2_1 ___ _

FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R21 thru 2R22 I certify that the (01/19/20 thru 05/17/21) activities represented by Repair/Replacement Plan number 60130007-001 O conform to the requirements of Section XI necessary to place the item in service.

Edition and Addenda of Section XI used: -~2~0~0~7~E=d=i=ti=o~n__,t~hr~o~uo.cg~h~2=0~0'--'8~A~d=de=n~d=a~-------- ------

Code Cases used for repair/replacement activities: ------'N___,_-__,5'--'3'-=2=----=5 ________ ______ __________ _

(If applicable, including cases modified by Case N-532 and later revisions)

Signed~-

~

~ner or Owner's designee Date -+-Z-**:B'....,._-~J...,~l _____ _

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60130007-0010, and state that, to the best of my knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damag or loss of any kind arising from or connected with this inspection.

Date _{_/'--=g'-4--fo__,-I _ _ _

FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R2 l thru 2R22 I certify that the

{01 / 19/20 thru 05/17/2 1) activities represented by Repair/Replacement Plan number 60130080-0010 conform to the requirements of Section XI necessary to place the item in service.

Edition and Addenda of Section XI used: -~2~0~0~7~E=d=i=ti=o~n~th~r~o~u__,q~h~2=0~0~8~A~d=d=e=n~d=a~--- -------- ---- --

Code Cases used for repair/replacement activities: _ __,N---'---'-5=3=2=---=5 _ __________ _____________ _ _

(If applicable, including cases modified by Case N-532 and later revisions)

___-:7,_/

~

Signed ~.-!~~"----

- ----- --::::~~~~----_:: ___ ______ _

~wner or Owner's designee Date _

__.7._----=-Y-._--=-..1._c._,\\ _ ____

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60130080-001 O, and state that, to the best of my knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage ss of any kind arising from or connected with this inspection.

---=--=,;ii~----"-=--'----'=5-<<4LJ4;'c...._---Commissions ___

__,N~B=--~1=50=8=3~

~C~A~2~1~8~4~A=l~/~IS~ /~l~-N~-~R~-- ------

ctor's Signatu National Board, State, Province, and Endorsements Date __

7_/~_/2_2_1 __

FORMNIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R2 J thru 2R22 I certify that the (01/19/20 thru 05/ 17/2 1) activities represented by Repair/Replacement Plan number __ 6~0~1=3=3=3=22=*~0=0=2=0 _ _

conform to the requirements of Section XI necessary to place the item in service.

Edition and Addenda of Section XI used: -

~ 2=0=0_7_~~~d~i_ti=o_n~t=h~ro~L~*g=h~2~0~0~8~A=d_d_e_n_da~----- ----- ----

Code Cases used for repair/replacement activities: -~N-=-5~3~2~-=5 __________________ _ ____ _ ___ _

(If applicable, including cases modified by Case N-532 and later revisions)

Signed

~

~

~

Owner or Owner's designec Date -----'7_-_[?':...,__-__.J..=-,.-------

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and employed by The Hartfo,*d Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60133322-0020

, and state that, lo the best of my knowledge and belief, the Owner has perfonned all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. furthermore, neither the Inspector nor his employer shall be I iable in any manner for any

  • s of any kind arising from or connected with this inspection.

Dale ------ -------

FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Posl 2R21 thru 2R22 I certify that the (01/19/20 thru 05/17/21) activities represented by Repair/Replacement Plan number 60133322-0040 conform to the requirements of Section XJ necessary to place the item in service.

Edition and Addenda of Section XI used: -~2~0~0~7~E=<=li=ti~o=n~t=h~ro~u=g=h~2=0~0~8~A=d=d=e=n=d=a--- ----- -----~

Code Cases used for repair/replacement activities: -

~ N~-5~3~2~-=5 _____ _ _ ______ _ ____ _ ______ _ _

(If applicable, including cases modified by Case N-532 and later revisions)

Signed ~~- ~

~

Owner or Owner's dcsignee CERTIFICATE OF INSERVICE JNSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Companv of Connecticut have inspected the items described in Repair/Replacement Plan number 60133322-0040

, and state that, to the best ofmy knowledge and belief, the Owner has pcrfonned all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning lhe activities described in the Repair/Replacement Plan. Furthennore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage o A~w*,

s;,,,, ""

loss of any kind arising from or connected with this inspection.

Commissions - --~NB

~ -~1=5~0=83~~C~A~2=1~8~4____,Al~~/~I=S~/ ~'~-N~-~R~-----

National Board, State, Province, and Endorsements

FORM NIS-2A REPAIR/REPLACEMENT CERTIFICA TlON RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R21 thm 2R22 I certify Urnl the (01/19/20 thru 05/ 17/21) activities represented by Repair/Replacement Plan number 60135944-0020 conform to the requirements of Section XI necessary to place the item in service.

Edition and Addenda of Section XI used: -

~2~0~0~7~F~~d=i=ti=o=n~t=h~ro=u"'g""h~2=0~0=8~A~d~d~e=n=d=a _____________ _

Code Cases used for repair/replacement activities: _ __,N~-5~3~2~-=5 ___________________________ _

(lfappl icable, including cases modified by Case N-532 and later revisions)

Sia~ ~

Owncior Owner's designcc CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Stc:im Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60 l 35944-0020

, and state that, to the best of my knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.

By signing U1is certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning tbe activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any n7ag~ r loss of any kind arising from or connected with this mspection.


=~~!'......,/J-~~~ZJ<::~ ____ Commissions NB-15083 CA 2184 AI/ JS/ 1-N-R National Board, State, Province, and Endorsements Date_f~~-g /2_____,z I~

FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R21 thru 2R22 I certify that the (01/19/20 thru 05/17/21) activities represented by Repair/Replacement Plan number 60133322-0005 conform to the requirements of Section XI necessary to place the item in service.

Edition and Addenda of Section XI used: -~2=0~0~7~E=* d=i=t1=* o~n~t=h~ro~1=1g=h~2=0~0~8~A=d=d=e~n=d-=aa ___________ __ ~

Code Cases used for repair/replacement activities: __

N_-5_3_2_-_5 _ ___ ___ ___________ ______ ___ _

(If applicable, including cases modified by Case N-532 and later revisions)

Signed~-

L-~-

Owner or Owner's designee CERTlFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60133322-0005

, and state that, to the best ofmy knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordm1cc with the requirements of Section XI necessary to place the item in service.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthennore, neither the Inspector nor his employer shall be liable in any manner for any r loss of any kind arising from or connected with this inspection.

FORMNIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R21 thru 2R22 I ccrtLfy that the (01/19/20 Ihm 05/17/21) activities represented by Repair/Replacement Plan number 60133322-0150 conform to the requirements of Section XI necessary to place the item in service.

Edition mid Addenda of Section XI used: _ __;2=0~0~7__,Ecec,,.,li'""li""o.,,n'--'t.""'h1,_,*o'"'u"'g"'h,_,2ce0,,..,0"-08'--'-'A,.,,d,.,,dc-e._,n.,,_d,,,a_~-------------

Code Cases used for repair/replacement activities: ---'N~ -5~3~2~-~5 ___ ___________ _ _____ _ _ _____ _

(If applicable, including cases modified by Case N-532 and later revisions)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Stenm Boiler lnspcction and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60133322-0150

, and state that, to the best ofmy knowledge and belief, the Owner has perfonned all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage r loss of any kind arising from or connected with this inspection.

Date_-1_1/l_8A_'l_/ _

FORM NfS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFJCATE OF CONFORMANCE Post 2R21 thru 2R22 I certify that the

/01/19/20 thru 05/17/21) activities represented by Repair/Replacement Plan number 60134325-0021 conform to the requirements of Section XI necessary to place the item in service.

Edition and Addenda of Section XI used: - ~2=0~0~7~E=* d=i=ti=o=n~t=h~rc~Juc.cg=h~2=0=0=8~A=d=d=e=n=d'-'-a _ ____ _ _____ _ _ _

Code Cases used for repair/replacement activities: _N~-=5=32~-5~------------------ ----- -----

(If applicable, including cases modified by Case N-532 and later revisions)

Signed~

~

~

Owner or Owner's designee Date 7-7-~\\

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60134325-0021

, and stale that, to the best ofmy knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary lo place the item in service.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furlhennore, neither the Inspector nor his employer shall be liable in any manner for any personal inju 1 dam ge or loss of any kind arising from or connected with this inspection.

Dale - - ---- -------

EQRfy1 NIS-2A REPAIR/REPLACEMENT CER.TIFICA TION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R2 l thru 2R22 l certify that the (01/19/20 thru 05/17/21) activities represented by Repair/Replacement Plan number 60134325-0030 conform to the requirements of Section XI necessary to place the item in service.

Ed ition and Addenda of Section XI used: -

---=2=0=0~7~E=d=i'-"ti=o,.,_n~t=h~ro~u"'g""h'--'2=-0=0=8~A=d=d=e,.,_n-"'d,,_a ______ _______ _

Code Cases used for repair/replacement activities: __

N~-5~3~2_-~5 _________________ _ _______ _ _ _

(If applicable, including cases modified by Case N-532 and later revisions)

Signe~

~

L-__

Date 7-S:-J-.,\\

Owner or Owner's designee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspcctinn and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60134325-0030

, and state that, to the best of my knowledge and belief, the Owner has perfonned all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.

By signing this ce11ificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthem10re, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage r loss of any kind arising from or connected with this inspection.

Date _

f_~_8/2_i ( _

FORM NlS-2A REPAIR/REPLACEMENT CERTIFICATION RECORQ OWNER'S CERTIFICATE OF CONFORMANCE Post 2R2 l lhru 2R22 I certify that the (01/19/20 thru 05/17/21) activities represented by Repair/Replacement Plau number 60 I 23 979-00 l 0 conform lo the requirements of Section XI necessary lo place the item in service.

Edition and Addenda of Section XI used: -

~ 2=0~0~7~E=' d=i=li=o=n~t=h1~*o=L=1g=h~2=0~0~8~A=d=d=e=n=d=a _____ _ _____ __ _

Code Cases used for repair/replacement activities: _ ___,N~-5=3~2=-~5~--------------

(If applicable, including cases modified by Case N-532 and later revisions)

Signed

~

- ~

~Owner or Owner's dcsignee Date __ 7_--~--~;)._~\\~ ----

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of l3oiler and Pressure Vessel Inspectors and employed by The Hnrtford Steam Boiler Inspection and Insurance Companv of Connecticut have inspected the items described in Repair/Replacement Plan number 60123979-0010

, and state that, to the best ofmy knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furlhem10re, neither the Inspector nor his employer shall be liable in any maimer for any personal i1tjury or property damage or loss of any kind arising from or connected with this inspection.

J! /

  • Commissions NB-15083 CA 2184 Al / IS / 1-N-R

~pector's s* nature National l3oard, Slate, Province, and Endorsements Date_1~/i_8!--'-z. ( _

FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R21 thru 2R22 I certify that the (01/19/20 thru 05/17/21) activities represented by Repair/Replacement Plan nu111ber _ _,6"'0~1=23~9~7~9---0"-'0~7~5-conform to the requirements of Section XI necessary to place the item in service.

Edition and Addenda of Section XI used: _ _;2,..,,0"'0-'-7_,E""* d,,,,i.,,,ti"'o.,_,n_,l""h""ro"'u""g,.,_h,_2=-0,,_0""'8"-'-'A""d"'d=e=n""'d"°a __________ ___ _

Code Cases used for repair/replacement activities: -~N~-5~3~2~-~5 _______________ _____ ___ ____ _ _

(If applicable, including cases 111odified by Case N-532 and later revisions)

Si 0 ned

~

- ~

0 ~

Owner or Owner's designee Date --"-7_-~l?':~-~~____,_\\ _ _ ___ _

CERTIFICATE OF lNSERVJCE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Co111pany of Connecticut have inspected the items described in Repair/Replacement Plan number 60123979-0075

, and state that, lo the best ofmy knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inju1y

_u,~~~~i_ ___ __ Commissions _ __

_,_N=B~-=l5~0=8=3~~C='A~2=1~8~4.__;A~I~/ ~IS~/_1~-N~-R.,___ _______ _

I National Board, State, Province, and Endorsements

FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R2 I lhru 2R22 I certify that the _

(01/19/20 thru 05/17/21) activities represented by Repair/Replacement Plan number _....,6,,.,0,._,l_.,2"---98"'0"-'8'---"'00""'l,_,O,__

conform lo the requirements of Section X1 necessary to place the item in service.

Edition and Addenda of Section XI used: ---=2=0'-"0'-'-7_,E,e.* d=i=ti,..,o=n....,l"'h""ro""u'°'g"°h~2=-0"-0""8e....,..A=d=d=e"-'nc:d=a _____ _ _______ _

Code Cases used for repair/replacement activities: - ~N~-5~3=2~-~5 ______________ ____ _ ___ _ __ _

s;,,,,,~L---

~ownerorOwner's dcsignee (If applicable, including cases modified by Case N-532 and later revisions)

Date _ _,__7_-~5C:~-~ol,~\\1--- - --

CERTIFICATE OF JNSERVICE INSPECTJON I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Companv of Connecticut have inspected the items described in Repair/Replacement Plan number 60129808-0010

, and state that, to the best ofmy knowledge m1d belief, the Owner has perfonned all activities described in the Repair/Replacement Plan in accordance with the requirements of Section X1 necessaiy to place the item in service.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conccming the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Date _

_ *1_/e._!Z_( _

.FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R2 I thru 2R22 I certify thal the (0 J /19/20 thru 05/17/21) activities represented by Repair/Replacement Plan number _ __,6=0~1=3~48=0=8~-0=0=3~0'---

conform lo the requirements of Section XI necessary to place the item in service.

Edition and Addenda of Section XI used: -

~ 2~0~0~7~E~~d~i~u~* o=n~t=hr~o~t=,g~h~2=00~8~A=d~d~e~n=d~a _ _ _________ __ _

Code Cases used for repair/replacement activities: -~N~-5=3=2~-~5 ____________________ _____ _ _ _

(If applicable, including cases modified by Case N-532 and later revisions)

Signed

~

?----

~

O wner or Owner's designcc Dale 7-J"'- )- \\

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National 13oard of Boiler and Pressure Vessel Inspectors and employed by The Hai-tford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60134808-0030

, and state that, to the best ofmy knowledge and belief, the Owner has perfom1ed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.

By signing this certificate neither the Tnspcclor nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthcm10re, neither the Inspector nor his employer shall be liable in any manner for any personal injury or properly dama e or loss of any kind arising from or connected with this inspection.

Date _

1 _/&/2

_ f I __

FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R21 thrn 2R22 I certify that the

{01/19/20 thru 05/17/21) activities represented by Repair/Replacement Plan number 601 35582-0020 conform to the requirements of Section XI necessa1y to place the item in service.

Edition and Addenda of Section XI used: -

--"2'-"0"'0--'--7_,E""c"'lic-'ti._,,o"-'n-'t..,hr"-'o"--'u"'g,,.h-'-'2=-0"-'0"--'8"----'-A,.,d'"'d=e~n""'d°"a _ _ _ _ ___ _ ____ _ _

Code Cases used for repair/replacement activities: -~N~-5~3~2~-~5 _ _____ __________________ _ _ _ _

(If applicable, including cases modified by Case N-532 and later rev isions)

S. d~?

1gne

~

Owner or Owner's designcc Datc _

_ 7~* -~g-:

~*_-_;c.2--=------- --

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National 13oard of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60135582-0020

, and state that, to the best ofmy knowledge and belief, the Owner has perfonncd all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.

By signing this certificate neither the !11Spector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthennore, neither the iuspector nor his employer shall be liable in any manner for,my r loss of any kind arising from or connected with this inspection.

Dale - - ---

FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RE£.QRD.

OWNER'S CERTIFICATE OF CONFORMANCE Post 2R2 I thru 2R22 T certify that the (01/19/20 thru 05/17/2 l) activities represented by Repair/Replacement Plan number 60135582-0160 confonn to the requirements of Section XI necessary to place the item in service.

Edition and Addenda of Section XI used: ---'2=0~0~7~E=*=d~it~io=n~t=h=ro~u=g=>'h==2~0~08~A=d=d~c=n=d=a'----

Code Cases used for repair/replacement activities: - --'N~-5=3=2~-~5'------------------ ----- ----

(If applicable, including cases modified by Case N-532 and later revisions)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60135582-0160

, and state that, to the best of my knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordm1ce with the requirements of Section XI necessary to place the item in se1vice.

By signing this certificate neither lhc Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in :my manner for any or propertY, damag or loss of m1y kind arising from or connected with this inspection.

FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R2 I thru 2R22 l certify that lhe (01/19/20 thrn 05/17/2 1) activities represented by Repair/Replacement Plan number 60 [35520-0020 conform to the requ irements of Section XI necessary to place the item in service.

Edition and Addenda of Section XI used: __

2~0~0~7~E~::d~it_io_n_t~h~ro~u=g=l_1 _2_00_8~A=d~d~e~n~d_a _ _ _ _____ ____ _ _

Code Cases used for repair/replacement activities: -~N~-5~3~2~-~5 _____________________ ______ _

(If applicable, including cases modified by Case N-532 and later revisions)

Date ?-?" - ]... \\

Sign~

Owner or Owner's designee CERTIFICATE OF INSERVTCE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60135520-0020

, and state that, to the best ofmy knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place U1e item in service.

By signing Uiis certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any Date_

"1_/i--'-a/i_z__,_1 __

Commissions ---~N~13~--1=5=08=3~ -C~A~2~1~8~4~A~l _l_l=S~/~1-~N_-~R~ ------ --

National 13oard, Stale, Province, and Endorsements

FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R21 thru 2R22 I certify that the (01/19/20 thru 05/17/21) activities represented by Repair/Replacement Plan number 60135560-0010 confonn to the requirements of Section X1 necessary to place the item in service.

Edition and Addenda of Section XJ used: -~2=0~0~7~E=* d=i=ti=o=n~t=h~ro=u=g=h~2=0~0=8~A~d=d=e~n=d=a _ _ ________ ___ _

Code Cases used for repair/replacement activities: - --'N~-5=3=2=-~5~-- ---------------- -------

(If applicable, including cases modified by Case N-532 and later revisions)

Datc_~'7-_-_*<'("~--J.-_\\~ ----

CERTIFICATE OF lNSERVICE INSPECTTON I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam lloilcr Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60135560-0010

, and state that, to the best ofmy knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthennore, neither the Inspector nor his employer shall he liable in any manner for any personal injury or properly damag or loss of any kind arising from or connected with U1is inspection.

Date~)ff-~_/@_/Z._J ~

_fORM NJS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R2 l lhru 2R22 I certify that the _

_ (01/19/20 thru 05/17/21) activities represented by Repair/Replacement Plan number 60135560-0015 conform to the requi rements of Section XI necessary to place the item in service.

Edition and Addenda of Section XI used: -~2~0~0~7~E=* d=i=t'~* o~n~t=h~ro~t=1g=h~2=0~0~8~A=d~d~e~n~d=a _ _ _ _ _________ _

Code Cases used for repair/replacement activities: - ~N~-5~3~2~-~5 ___________________________ _

(If applicable, including cases modified by Case N-532 and later revisions)

~c:._

Sioned

" ~ er or Owner's designee Dale 7---':/:-,)._., l CERTJFrCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National 13oard of'Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Companv of Connecticut have inspected the items described in Repair/Replacement Plan number 60135560-0015

, and state that, to the best of my knowledge and belief, the Owner has perfonned all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the activities described in the Repair/Replacement Plan. Furthermore, neither the hispeclor nor his employer shall be liable in any manner for any loss of any kind arising from or connected with this inspection.

Datc _

--1_/ B_

/ z _. ( --

FORM NIS-2A REP AIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R2 I thru 2R22 I certify that the (01/ 19/20 thru 05/J7/21) activities represented by Repair/Replacement Plan number 60016997-001 I conform to the requirements of Section XI necessary to place the ite111 in service.

Edition and Addenda or Section X1 used: -~2=0-"0~7~E=" d=i=ti=o=n~t=h~ro~t=1g=h~2=0~0~8~A=cl=cl=c=n=cl=a _____________ _

Code Cases used for repair/replacement activities: ---'N~-5"-'3"-'2=---"5'-----------------

(If applicable, including cases modified by Case N-532 and later revisions)

~~

Signed Owner or Owner's designee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid co111111ission issued by the National Board of Boiler and Pressure Vessel Inspectors and e111ploycd by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the ite111s described in Repair/Replacement Plan number 60016997-001 I

, and state that, to the best ofrny knowledge and belier, the Owner has perfor111ed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or i111plied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any maimer for any personal injury or properly damage or loss of any kind arising from or connected with this inspection.

Date __

  • --1~/R_f<_Z. I __

FORMNIS-2A REPAIR/REPLACEMENT CERTIFICATION RECOR!)

OWNER'S CERTIFICATE OF CONFORMANCE Post 2R21 thru 2R22 I certify that the (01/19/20 thru 05/17/21) activities represented by Repair/Replacement Plan number 60092871-0011 conform to the requirements of Section XI necessary to place the item in service.

Edition and /\\ddenda of Section XJ used: -~2~0~0~7_r~:d~i~t~io~n~t=h=ro_u=g=h~20=0_8~A=d~d~e=n=d=a- - - --- - ---- - - ~

Code Cases used for repair/replacement activities: -- ~N~-~5~3=2~-~5 _____ ___ ____ ____ _ ____ _ _ _ __ _

(If applicable, including cases modified by Case N-532 and later revisions)

~

~

S.

d

~

1gne Owner or Owner's designcc CERTIFICATE OF INSERVICE JNSPECTION I, the undersigned, holding a valid commission issued by lhc National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam lloilcr Inspection and Insurance Companv of Connecticut have inspected the items described in Repair/Replacement Plan number 60092871-001 1

, and state that, to the best of my knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section X1 necessary to place the item in service.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthennorc, neither the Inspector nor his employer shall be liable in any manner for any or loss of any kind arising from or connected with this inspection.

Date -

~

FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R21 thru 2R22 I certify that the (01/19/20 thru 05/J 7/21) activities represented by Repair/Replacement Plan number --'6=0~1=3=07~6=3~-0=0~5~0'------

conform to the requirements of Section XI necessary to place the item in service.

Edition and Addenda of Section XI used: __

2~0~0~7~E=* d=i~t~io~n~t~h~ro~u=g=h~2=0~0~8~A~d~d~e=n~d=a _____ ________ _

Code Cases used for repair/replacement activities: - ~N~-5~3~2~-~5----------~-------- ------ --

(If applicable, including cases modified by Case N-532 and later revisions) s;o,~ ~

"' ~

Owner or Owner's designee CERTIFICATE OF TNSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by Ilic National Board of l3oiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60130763-0050, and state that, to the best ofmy knowledge and belief, the Owner has pcrfonned all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.

By signing this certificate neither the l11spector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any damag or loss of any kind arising from or connected with this inspection.

Date ----'*1----=cls_.___(l_1 --

FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R21 thru 2R22 l certify that the (01/19/20 thru 05/17/21) activities represented by Repair/Replacement Plan number 64168577-0350 conform to the requirements of Section XI necessary lo place the item in service.

Edition and Addenda of Section XI used:, __ _;2=0=0~7~E=c=li=ti=o'-"n'-'t=h~ro=u,,,g"'-h~2=0~0=8~A""d=d=e=n=d-=-a _ _ ___________ _

Code Cases used for repair/replacement activities: _ _ N_-5~3~2_-~5 _ ___ _______ _ _ _____ _ ___ _ ___ _ _

(If applicable, including cases modified by Case N-532 and later revisions)

Sio11ed~ ~---

" ~wner or Owner's designee Date _

_ 7_5,<-

=. _-_.l.,_\\ ___ _

CERTIFICATE OF INSERVICE INSPECTION J, the undersigned, holding a valid commission issued by the National Board of Boi ler and Pressure Vessel inspectors and employed by The Hartford Steam Boiler inspection and insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 64168577-0350

, and state that, to the best ofmy knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Sec:tion Xl necessary to place the item in service.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthennore, neither the Inspector nor his employer shall be liable in any manner for any or loss of any kind arising from or connected with this inspection.

Date __

-,_/Q_/L_{ _ _

fORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R2 I thrn 2R22 l certify that the (01/19/20 thru 05/17/21) activities represented by Repair/Replacement Plan number 60136124-0IO0 confom1 to the requirements of Section XI necessary lo place the item in service.

Edition and Addenda of Section Xl used: -

--=2=0~0~7-"E""* d=i=ti=o=n~t=h~ro=1""1g""h~2,,_0~0=8~A~d=d=e=n=d=a_~ -

- ---------~

Code Cases used for repair/replacement activities: - ~N~-5~3~2~-=5 _ ___ _ ____ _ ___ _ _ _ _ _ _ ____ _ ___ _

(If applicable, including cases modified by Case N-532 and later revisions)

Signed~

~

Owner or Owner's designee CERTIFICATE OF JNSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board oJ Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Tnspeclion and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60136 124-0100

, and state that, to the best ofmy knowledge and belief, the Owner has pcrfonned all activities described in the Repair/Replacement Plan in accordance with the req uirements of Section XI necessary to place the item in service.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any Commissions _ _ _ ____;NB

~

-~1=5=0=83~~C~A~2~!~8~4---'A~I ~/~l=S~/ ~1-~N~-=R~---

National Board, State, Province, and Endorsements Date~*1_ /g_/z_1 _

,EQRM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R2 l thru 2R22 I certify that the (01/19/20 thru 05/17/21) activities represented by Repair/Replacement Plan number 64168059-0035 confom1 to the requirements of Section XI necessary to place the item in service.

Edition and Addenda of Section XI used: --"2"'0'-"0'-'-7_,E"":'.d,,,i""ti"'o'°'n-'t,.,h~ro"-'u"-'g,.,_h'--'2"'0""'0"-'8"-A...=d,..,,d,..,,e-'-'n.,,_d"'-a _ _ _____ _ ____ _ _

Code Cases used for repair/replacement activities: -~N~-5~3~2~-~5 _____________________ _ ____ _ _

(If applicable, including cases modified by Case N-532 and later revisions)

~~-

SignedEJ--- ------ - ----- - --- - ------ - --

~

Owner or Owner's designcc Dale ~ZL._*

  • ___,-It:..._

.* _-d--=----..,\\'-----

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 64168059-0035

, and state that, to the best ofmy knowledge and belief, the Owner has perfom1ed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessaiy to place the item in service.

13y signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthem1ore, neither the Inspector nor his employer shall be liable in any manner for any

--- ~~-4,.._J~~~~m'f.J.~gle._o_r_lo_s_s_o_f_w:::::::;:::: from oc oo:,::,:*h U:~:*~:1;,:1 1 IS / J-N-R National Board, State, Province, and Endorsements

FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R2 l thru 2R22 I certify that the (01/19/20 thru 05/17/21) activities represented by Repair/Replacement Plan number 60122244-0010 conform lo the requirements of Section XI necessa,y lo place the item in service.

Edition and Addenda of Section Xl used: -~2~0~0~7~E~* d=i=ti~o~n~t~h=n~n=tg=h=2~0~0~8~A~d~d~e~n=d=a.~ - ---

Code Cases used for repair/replacement activities: -

~N~-5=3=2~-~5'------- ---------------- ------

Sigo~ ~

(If applicable, including cases modified by Case N-532 and later revisions)

~

Owner or-Owner's designee CERTIFfCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board ol'Boiler and Pressure Vessel Inspectors and employed by The Hartfonl Steam Iloilcr Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 60122244-0010

, and slate that, to the best of my knowledge and be! ief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.

13y signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in tbe Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any or loss of any kind arising from or connected with this inspection.

FORM NIS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R21 tl1rn 2R22 I certify that the (01/19/20 thru 05/l 7/21) activities represented by Repair/Replacement Plan number 64221959-0300 conform to the requirements of Section Xl necessaiy to place the item in service.

Edition and Addenda of Section XI used: -~2~0~0~7~E=d=i=ti~o=n~t=hr~o~u=g=h~2=0~0~8~A~d~d~e=n=d=a _ _ _ _ _ _____ _ _ _ _

Code Cases used for repair/replacement activities: - ---'N~-5~3=2~-=5 _ __________________ _ _____ __ _

~ (If applicable, including cases modified by Case N-532 and later revisions)

Signed,..~

~ Date Z-V-2...\\

Owner or Owner's designce CERTIFICATE OF INSERVICE INSPECTION l, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Companv of Connecticut have inspected the items described in Repair/Replacement Plan number 64221959-0300

, and stale that, to the best ofmy knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary lo place the item in service.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property d

~'""

Sig, Commissions Nil-15083 CA 2184 Al / IS / 1-N-R National Iloard, State, Province, and Endorsements Date

'1 /a/z I

FORM NIS-2A REPAIR/~EPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R21 lhru 2R22 I certify that the (OI/19/20 thm 05/17/21) activities represented by Repair/Replacement Plan number 64231256-0300 conform to the requirements of Section XI necessary to place the item in service.

Edition and Addenda of Section XT used: _ _ 2~0~0~7~E~_,d~i~ti_o_n_l_h1_*o~u=g=h~2_0~0~8~A_d_d_e_n~d~a _ ____ _ ______ _ _

Code Cases used for repair/replacement activities: -~N~-5~3~2~-~5 _____ __________________ _ _ _ _ _

Sigo~ ~

Owneror Owner's designec (If applicable, including cases modified by Case N-532 and later revisions)

Date_---'-;7_**_-*_0_-_2,_\\ _ _ __ _

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have impected the items described in Repair/Replacement Plan number 6423 I 256-0300

, and state that, to the best of my knowledge and belief, the Owner has perfom1ed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.

By signing this ce11ificale neither the fospcctor nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inJury or property da]na

  • or loss of any kind arising from or connected with this inspection.

_ _ ---(,,,t&_'Y.Ja-n.~~~:__<_ _ _ _ _

Co111111issions NB-15083 CA 2184 Al/ JS / 1-N-R National Board, State, Province, and Endorsements Date ~----'--

1,___/ 8--'-/ l~( ~

FORM NIS-2A REPAIR/REPJ,ACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2 R2 I U1ru 2R22 I certif'.Y that the (01/19/20 thrn 05/17 /21) activities represented by Repair/Replacement Plan number 64159867-0 I 00 conform to U1e requirements of Section XI necessary to place the item in service.

Edition and Addenda of Section XI used: -~2=0=0~7~E=-d=i=ti=o=n~t=h~ro~uc..g""h~2=0~0=8~A=d=d=e=n=d=a _ _ ____ _ _ _____ _

Code Cases used for repair/replacement activities: _ __,N~-5~3~2~-=5 _ ___________ _____________ __ _

(If applicable, including cases modified by Case N-532 and later revisions)

~~.

Signe

~

Owner or Owner's designee CERTIFICATE OF JNSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel l11spectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 64159867-0100

, and state that, to U1e best of my knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan ia accordance with the requirements of Section Xl necessary to place the item in service.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or impl ied, concerning the activities descri.bed in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in llilY manner for any personal injury or property dama]

0 e. r loss of any kind ai ising from or connected with this inspection.

--~

=-=-~'...J:=.~:.E.::t,1.,~'.E...:__ ___

Commissions NB-15083 CA2184 Al/ IS/ 1-N-R National Board, State, Province, and Endorsements Datc __

-1_/_el_i_, -~

FORM NIS-_2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R21 thru 2R22 I certii), that the (01/19/20 thru 05/17/21) activities represented by Repair/Replacement Plan number 64159902-0100 confonn to the requirements of Section X[ necessary to place the item in service.

Edition and Addenda of Section Xl used: _ __;2=0~0_,_7~E=d=i=li=o=n~t=h~ro=t~1g""h~2=0~0=8~A=d=d=c=n=d-"'a _ _____ ______ _ _

Code Cases used for repair/replacement activities: _ __,N_,_-~5=3=2=----"5 _____ ___________ _____ _ _ _ _ _ _ _

s;gaed~ ~

(tr applicable, including cases modified by Case N-532 and later revisions)

Owner or Owner's dcsignee Date_7_-_f"-_-_J.._\\ _ _ _

CERTIFICATE OF INSERVICE INSPECTION T, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 64159902-0100

, mid state that, to the best of my knowledge and belief, the Owner has perfom1ed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.

ily signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage r loss of any kind arising from or connected with this inspection.

Date_1_/8~/(_{ ~

FQRMNJS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R21 thm 2R22 I certify that the (01119/20 thru 05/17/21) activities represented by Repair/Replacement Plan number 64164879-0100 conform to the requirements of Section X1 necessary lo place the item in service.

Edition and Addenda of Section XI used: ---=2=0=0~7~E=d=i=ti=o=n~t=h~ro=Lec<lg""*h~2=0~0~8~A=d=d=e=n=d-=ca _ _ _ ____ ___ ___ _

Code Cases used for repair/replacement activities: _ __,N

'--'--'-5""'3""'2""-""'5~-------------- -------

(If applicable, including cases modified by Case N-532 and later revisions)

Signed~ /--,___

~Owner or Owner's designee CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The m1rtford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 64 164879-0JOO

, and stale that, to the best ofmy knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.

By signing this ce1tificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthennore, neither the Inspector nor his employer shall be liable in m1y manner for any ama,

  • or loss of any kind arising from or connected with this inspection.

Datc ~

1 _/0_/l_l

~

FORM NIS-2A REPAIR/REPLACEMENT CERTJFTCA TlON RECORD OWNER'S CERTIFJCATE OF CONFORMANCE Post 2R2 l thru 2R22 l certify that the (01/19/20 thru 05/17/21) activities represented by Repair/Replacement Plan number 64165009-0100 conform to the requirements of Section XI necessary to place the item in service.

Edition and Addenda of Section XT used: -

--=2'-"0'-"0~7~E=Jd=i=ti"'o=n~l=h~ro=t"'tg"'h-'-=20""0=8~A=d=d=e=n=d=a _ _ _ _______ ___ _

Code Cases used for repair/replacement activities: _ __,N~-5"'3'--'2=---__,,5 ___ _ _ ___________ ___ _______ _ _

~~.

(If applicable, including cases modified by Case N-532 mid later revisions)

Signe Owner or Owner's designee CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 64165009-0100

, and state that, Lo the best of my knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordm1ce with the requirements of Section Xl necessary to place the item in service.

By signing this certificate neither the Inspector nor his employer makes m1y warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any mmmer for any personal inju, or property damag or loss of any kind arising from or connected with this inspection.

Date --------'-+

1 /2-----=--.,_8/----'---'--z

/ _ _

FORM NIS-2A REPAIR/REPLACEMENT CERTffJCA TION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R2 l thru 2R22 I certiiY that the (01/19/20 Ihm 05/17/2 I) activities represented by Repair/Replacement Plan number 60131924-0030 conform to the requirements of Section XI necessary to place the item in service.

Edition and Addenda of Section XI used: -~2=0~0~7~E=* d=i=ti=o=n~t=h=ro~u=g=h~20~0=8~A=d=d=e=n~d=a--

- -~

Code Cases used for repair/replacement activities: -

~N~-5=3~2~-~5 _______ _ ______ _____ _______ _

(If applicable, including cases modified by Case N-532 and later revisions)

'd ~-~

Signe~

Owner or Owner's designee CERTJFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Jnspeclion and Insurance Comnanv of Connecticut have inspected the items described in Repair/Replacement Plan number 60131924-0030

, and state that, to the best of my knowledge and belief, the Owner has performed all activities described in lhe Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Jnspcctor nor his employer shall be liable in any manner for any personal inJury or p1opcrly damag! or loss of any kind arising from or connected with this inspection.

_ _ ___:::_~c__...t;J.~~~n,,.):______ _ _ _ _

Commissions NB-15083 CA2184 AI/ IS/ 1-N-R National Board, State, Province, and Endorsements

FORM NJS-2A REPAIR/REPLACEMENT CERTIFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R2 I thm 2R22 l certify that the (01 / 19/20 lhru 05/17/21) activities represented by Repair/Replacement Plan number -

~6~4=0~05~1~0=3--0=1~0=0-conform to the requirements of Section XI necessmy to place the item in service.

Edition and Addenda of Section Xl used: __

2~0~0~7_E_d_1_* l_io_n~t~h~ro~1=1g=h~2~0~08~A~d~<l_e_n_d~a _ ____________ _

Code Cases used for repair/replacement activities: -~N~-5~3~2~-=5 _____________________ _ _ ____ _

CERTIFICATE OF INSERVICE INSPECTION l, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 64005103-0100

, and slate that, to the best ofmy knowledge and bel ief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XI necessary to place the item in service.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in m1y manner for any or properly damage or. loss of any kind arising from or connected with this inspection.

Da~_ 1_h_h~, __

FORM NIS-2A REPAIR/REPLACEMENT CERTIFICA TrON RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R21 Ihm 2R22 I certify that the (Ol/19/20 thru 05/17/21) activities represented by Repair/Replace111ent Plan number _...,6~4=1=3=19~9~4~-0~I~O=O __

conform to the requirements of Section XI necessary to place the item in service.

Edition and Addenda of Section XI used: -

~ 2~0~0~7~E=d~it~i o~n~t=h~ro=u=g=h~20~0=8~A=d~d~c=n=d~a _ ____________ _

Code Cases used for repair/replacement activities: -~N~-5~3~2=-~5 __________________ _________ _

(If applicable, including cases modified by Case N-532 mid later revisions)

Signe~~

Owner or Owner's designee CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by U1c National l3oard of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Companv of Connecticut have inspected the items described in Repair/Replacement Plan number 64131994-0100

, and state that, to the best ofmy knowledge mid belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordm1ce with the requirements of Section XI necessary lo place the item in service.

By signing this certificate neither the Inspector nor his employer makes miy warrm1ty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthennore, neither the Inspector nor his employer shall be liable in any manner for any or loss of any kind arising from or connected with this inspection.

Date -

FORM NIS-2A REPAIR/REPLACEMENT CERTlFICATION RECORD OWNER'S CERTIFICATE OF CONFORMANCE Post 2R2 I thru 2R22 l certify that the (01/19/20 thru 05/17/21 l activities represented by Repair/Replacement Plan number -

--'6~4~1=3=9~43~1-~0~1=00"'-----

cont<mn to the requirements of Section XI necessary to place the item in service.

Edition and Addenda of Section XI used: _ ___,2=0~0~7--'E=* d=1=*t1~* o=n~t=h~ro=u=g=l~1 =20=0=8~ A=c=lc=le=n=d=a _ _ ______ _ _ ___ _

Code Cases used for repair/replacement activities: _ ___,N~-5=3=2~-~5 _____ __________ ___ _______ __ _

(If applicable, including cases modified by Case N-532 and later revisions)

~~.,

Sign~

Owner or Owner's designee CERTIF[CATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in Repair/Replacement Plan number 64139431-0100

, and state that, to the best ofmy knowledge and belief, the Owner has performed all activities described in the Repair/Replacement Plan in accordance with the requirements of Section XL necessary to place the item in service.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in the Repair/Replacement Plan. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any pe,soa,i ;,j,,y "'prnpo, d,~,"' lo~ of MY k;od.,;,;,g ftom """"""',0,1,,1,;, ;,sp,e,;,,.

---1L-----=Jl£--P-...::=..:=01"'j"---------- Commissions NB-15083 CA2 184 Al/ JS/ I-N-R National Board, State, Province, and Endorsements