B18942, Steam Generator Tube Inservice Inspection Report
| ML032471591 | |
| Person / Time | |
|---|---|
| Site: | Millstone |
| Issue date: | 08/25/2003 |
| From: | Price J Dominion Nuclear Connecticut |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| B18942, FOIA/PA-2005-0210 | |
| Download: ML032471591 (46) | |
Text
Dominion-Dominion Nudear Connecticut, Inc.
Millstone Power Station Rope Ferry Road Waterford, Cr 06385 AlG 25 213 Docket No. 50-423 B18942 RE: 10 CFR 50.36 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555 Millstone Power Station, Unit No. 3 Steam Generator Tube Inservice Inspection Report This special report is being submitted pursuant to Millstone Unit No. 3 Technical Specification 4.4.5.5.b and 6.9.2.
The end of Millstone Unit No. 3 Cycle 8 Steam Generator tube inspection was completed September 22, 2002.
This report also provides a summary of RFO8 Condition Monitoring and Operational Assessments.
There are no regulatory commitments contained within this submittal.
If you should have any questions regarding this submittal, Mr. David W. Dodson at (860) 447-1791, extension 2346.
please contact Very truly yours, DOMINION NUCLEAR CONNECTICUT, INC.
President - Millstone cc:
See next page Ao(rl
U.S. Nuclear Regulatory Commission B18942/Page 2 Steam Generator Tube Inservice Inspection Report
'A' Steam Generator AVB Indications
'A" Steam Generator Volumetric Indications "A" Steam Generator Single Volumetric Indications XC" Steam Generator AVB Indications "C" Steam Generator Volumetric Indications SC" Steam Generator Single Volumetric Indications cc:
H. J. Miller, Region I Administrator V. Nerses, NRC Senior Project Manager, Millstone Unit No. 3 Millstone Senior Resident Inspector
Docket No. 50-423 B18942 Millstone Power Station, Unit No. 3 Steam Generator Tube Inservice Inspection Report
U.S. Nuclear Regulatory Commission B18942/Attachment 1/Page 1 Millstone Unit No. 3, Cycle 8 Steam Generator Tube Inservice Inspection Report Table of Contents Page Examination Scope...............................................................................................................2 Results...............................................................................................;
2 Tube Repairs
.4 Condition Monitoring Assessment Summary
.5 Operational Assessment Summary
.5 TABLE 1: MILLSTONE 3 RF08 ECT
SUMMARY
.7 TABLE 2: LOCATION OF TUBES PLUGGED FOR AVB WEAR SIZED 2 40% TW DURING MILLSTONE 3 RF08
.8 TABLE 3: LOCATION OF DISCRETIONARY TUBES PLUGGED FOR AVB WEAR DURING MILLSTONE 3 RF8
.8 TABLE 4: LOCATION OF TUBES PLUGGED FOR SVI, OBS, OR PLP DURING MILLSTONE 3 RF08
.8 TABLE 5: TOTAL TUBES PLUGGED TO DATE
.9
It U.S. Nuclear Regulatory Commission B18942/Attachment I/Page i Millstone Unit No. 3, Cycle 8 Steam Generator Tube Inservice Inspection Report Examination Scope A full length eddy current inspection was performed on 11,218 tubes (100 percent of the operable tubes in Steam Generators (SGs) "A" and 'C"), or approximately 50 percent of the total population of tubes in all Millstone Unit No. 3 SGs. Additionally, extensive augmented testing (8,601 tube locations) was conducted in SGs 'A' and "C" utilizing rotating probes Incorporating plus point coils. The plus point probe provides superior detection of both circumferential and axial cracks, and has been qualified for the detection of cracking mechanisms per the Electric Power Research Institute (EPRI)
"PWR Steam Generator Examination Guidelines, Appendix H (Performance Demonstration for Eddy Current Examination)." The rotating probe inspections were performed in areas of special Interest (e.g., hot leg tube sheet areas, low row u-bends, bulges, wear, and dings) where bobbin probe response may be ambiguous, or does not provide adequate detection and/or diagnostic capabilities. The 8,601 tube sample also included a scope expansion at top-of-tubesheet (UTS) locations In the hot and cold legs, triggered by loose part wear.
Results Table 1, "Millstone 3 RFO8 ECT Summary," and the discussion below provide a synopsis of the SG tube inspections and results. Tube specific results are presented in Attachments 2 through 7.
Steam Generator "A" A total of 5965 bobbin and 5499 rotating pancake coils (RPC) examinations were performed in SG "A." This included an expansion of 2260 RPC examinations at the top of the tubesheet, and 133 special Interest locations.
The primary degradation mechanism in SG "A" continues to be mechanical wear, mostly at the anti-vibration bar (AVB) locations. A total of 222 AVB wear indications (112 tubes), containing indications ranging in depth from 9 to 41 percent throughwall, were identified during the bobbin examination.
These results are presented in Attachment 2, "'A' Steam Generator AVB Indications." Of these 112 tubes, 2 tubes (3 AVB locations) exceeded the plugging limit. The plugging limit is defined within Millstone Unit No. 3 Technical Specifications as an imperfection depth of 40 percent nominal tube wall thickness or greater. Additionally, 4 tubes were removed from service on a discretionary basis, with AVB wear exceeding 36 percent.
The RPC examination resulted in 43 volumetric indications affecting 36 tubes.
Twenty-eight of these indications (25 tubes) were determined to be manufacturing burnish marks and not service related. These are reported as VOL in Attachment 3,
"'A' Steam Generator Volumetric Indications." The remaining 15 indications were considered to be loose part wear or manufacturing burnish marks that could not be
f.
U.S. Nuclear Regulatory Commission B18942/Attachment 1/Page 3 confirmed with the bobbin coil. These are reported as single volumetric indications (SVls) and are located at TTS. The SVIs are documented in Attachment 4, "'A" Steam Generator Single Volumetric Indications." All SVIs were sized using an EPRI Appendix H qualified technique. Of these 15 SVI indications, only two exceeded the plugging limit. Table 1, 'Millstone 3 RFO8 ECT Summary," provides a breakdown of the depth distribution of these flaws.
The inspection results from SG WA" were classified as C-2 due to AVB and loose part wear. The C-2 category, per the Millstone Unit No. 3 Technical Specifications, resulted from the identification of "one -or more tubes, but not more than 1 % of the total tubes inspected' being defective.- Since 100 percent of the tubes in the AVB region of both SGs were included In the initial inspection sample, no technical specification scope expansion was required. However, consistent with the Nuclear Energy Institute's'NEI 97-06, "Steam Generator Program Guidelines," and the Millstone Steam Generator Program, a 20 percent expansion was performed at TTS locations in both the hot and cold legs of SG WA" to address the C-2 resulting from loose part wear.
This expansion exceeds the Technical Specification scope expansion requirements for a 0-2 result.
Steam Generator "C" A total of 5983 bobbin and 3129 RPC examinations were performed in SG "C." The RPC examinations included 79 previous history locations and 15 special interest locations.
The only identified degradation mechanism in SG "C" continues to be mechanical wear at the AVB locations. A total of 20 tubes were identified as containing 54 AVB indications, ranging in depth from 10 percent throughwall to 45 percent throughwall.
These results are presented in -Attachment 5, "'C' Steam Generator AVB Indications." One hundred percent bobbin inspection of operable tubes identified that one tube had indications exceeding the plugging criteria. That location, Row 41, Column 61, was removed from service by the installation of Framatone Alloy 690 Rolled Mechanical Tube Plugs.
The RPC examination identified 16 volumetric indications in 14 tubes. Eight of these indications were determined to be manufacturing burnish marks and not service induced. These are reported as VOL in Attachment 6, "'C' Steam Generator Volumetric Indications."
The remaining eight indications were considered to be loose part wear or manufacturing burnish marks that could not be confirmed with the bobbin coil.
These are reported as SVIs and located at TTS.
The SVls are documented in Attachment 7, "'C' Steam Generator Single Volumetric Indications."
All SVls were sized per an EPRI Appendix H qualified technique. None of the 8 SVI indications exceeded the plugging limit. However, one SVI had an associated loose part indication and was discretionally removed from service. Table 1, "Millstone 3 RFO8 ECT Summary" provides a breakdown of the depth distribution of these flaws.
The inspection results from Steam Generator "C" were classified as C-1.
I; U.S. Nuclear Regulatory Commission B18942/Attachment 1/Page 4 Tube Repairs The plugging limit is defined within Technical Specifications as an imperfection depth of 40 percent or greater of the nominal tube wall thickness. The eddy current examination identified AVB flaws greater than or equal to the plugging limit in 3 tubes. These tubes are identified in Table 2, "Location of Tubes Plugged for AVB Wear Sized > 40% TW During Millstone 3 RFO8." Additionally, two tubes were reported with SVIs exceeding the plugging limit. These are identified in Table 4, "Location of Tubes Plugged for SVI, OBS, or PLP During Millstone 3 RFO8."
Four tubes with AVB wear were removed from service on a discretionary basis. These tubes exhibited AVB wear greater than 36 percent throughwall, but less than the plugging limit (see Table 3, "Location of Discretionary Tubes Plugged for AVB Wear During Millstone 3 RF08"). The remaining two tubes were conservatively plugged for the following reasons:
One tube in the "C" SG was identified with an obstruction (OBS) that would not allow the insertion of a probe which would provide sufficient eddy current fill factor. That location, Row 1, Column 115, was removed from service.
One tube In location Row 1, Column 4, of the UC' SG was identified with an SVI and in contact with an adjacent, lodged loose part (PLP). Although only minor tube damage has occurred, the damaged tube was stabilized and removed from service. A Framatone stabilizer was utilized to increase the damping of the tube, thereby reducing possible flow induced vibration, and also to prohibit interaction with adjacent tubes in the unlikely event of a complete severance.
These tubes are identified in Table 4, "Location of Tubes Plugged for SVI, OBS, or PLP During Millstone 3 RF08."
The tubes removed from service during Millstone Unit No. 3 Refueling Outage 8 (RF08) can be grouped into four categories:
Seven tubes exhibited degradation attributed to AVB wear.
This number includes four tubes having Indications less than 40 percent throughwall, but removed on a discretionary basis.
Two tubes exhibited an SVI which exceeded the plugging limit at the TTS.
Millstone used a sizing technique qualified to EPRI Appendix H Guidelines for these Indications.
One tube was identified with an SVI and as being in close proximity to a non-retrievable loose part. This tube was removed from service on a discretionary basis.
One tube was identified with an obstruction that would not allow the insertion of a probe that would provide sufficient eddy current fill factor.
a.
U.S. Nuclear Regulatory Commission B18942/Attachment 1/Page 5 The eleven tubes were removed from service on September 21 and 22, 2002, by the installation of a Frametone Alloy 690 Rolled Mechanical Tube Plug. Table 5, 'Total Tubes Plugged to Date," provides historical documentation of all SG tubes plugged at Millstone Unit No. 3.
Condition Monitoring Assessment Summary The condition of the SGs as determined during RFO8 using non-destructive examination (NDE) techniques qualified to EPRI's PWR Steam Generator Examination Guidelines, Rev. 5, Appendix H, met the three NEI 97-06 performance criteria. All indications of tube degradation Identified during the examination were well below the applicable structural integrity limit, with required allowances for NDE sizing uncertainty.
The examination revealed no evidence of plug degradation or installation deficiencies, and minimal primary to secondary leakage occurred (less than one gallon per day) during fuel cycle eight. No throughwall or near-throughwall defects were Identified and no structural limits were exceeded, therefore the accident leakage performance criteria was not exceeded during the operating period prior to RFO8.
Operational Assessment Summary There is reasonable assurance that the Millstone Unit No. 3 SGs can continue to operate until their next planned tube examinations (Refueling Outage 9 for SGs "B" and
'D," Refueling Outage 10 for SGs 'A" and "C"), without causing any of the NEI 97-06 performance criteria to be exceeded. The observed growth rates associated with AVB wear, foreign object wear, and flow distribution baffle wear supports the conclusion that no wear exceeding the structural limit, with allowances for NDE sizing uncertainty and NDE probability of detection, will occur prior to the next examination in any of the four SGs.
During RFO8, all foreign objects which could be retrieved were removed from the SGs.
Upon completion of the RFO8 tube examination, all tubes with Indications of AVB wear exceeding 36 percent throughwall were removed from service by plugging.
During Refueling Outage 7 (RFO7), visual examinations within the feedrings of all four SGs, and ultrasonic examinations of the feedrings in SGs "B" and SD" provided the data necessary to trend the progression of previously identified erosion. Feedring/J-tube erosion was identified, evaluated, and concluded to be acceptable for at least two additional cycles of operation. Consequently, this degradation will not threaten SG tube integrity during the next operating cycle.
A visual examination of upper internal components in all four SGs during RFO7, and in limited locations in SG "A" during RFO8, revealed no degradation which could threaten tube integrity. Therefore degradation of these components to the extent that could threaten tube Integrity is not expected to occur prior to the next inspection of each of the SGs.
The absence of secondary side structural degradation and plug deficiencies provides a high level of confidence that tube degradation, related to secondary support structure
U.S. Nuclear Regulatory Commission B18942/Attachment 1/Page 6 deficiencies, will not occur during these operating periods. The absence of secondary side structural degradation provides a high level of confidence that tube degradation caused by secondary supp"It deterioration will not occur in any of the SGs prior to the next inspection of each SG.
U.S. Nuclear Regulatory Commission B18942/Attachment 1/Page 7 TABLE 1: MILLSTONE 3 RFO8 ECT
SUMMARY
SG A SG C TOTAL Number of Tubes (SG A and C only) 5,626 5,626 11,252 Number of Tubes Inspected F/L wI 5,561 5,596 11,157 Bobbin Probe X
Number of Tubes Inspected w/
39 21 60 Bobbin Probe Hot Leg and Cold Leg Straight Sections Only (Row 1)
Number of Tubes Incomplete w/
0 1
1 Bobbin Probe due to Obstruction Number of Tube Inspections w/
5,483 3,118 8,601 MRPC (Total)
- Hot Leg Transitions - Original 2,985 2,855 5,840 Scope
- Hot Leg Transitions - Scope 1,134 0
1,134 Expansion
- Row 1 and 2 U-Bends 121 121 242
- Hot Leg Misc. Special Interest 95 98 193
- Diagnostic Exams and from Previous History (tubes)
- Cold Leg Transitions - Scope 1,129 35 1,164 Expansion
- Cold Leg Misc. Special 19 9
28 Interest - Diagnostic Exams and from Previous History (tubes)
Tubes with Max AVB Wear Ž 40%
2 1
3 Tubes with Max AVB Wear Ž 20%
52 13 65 but < 40%
Tubes with Max AVB Wear <- 20%
58 6
64 Tubes with Max SVI 2 40%
2 0
2 Tubes with Max SVI Ž 20% but <
2 3
5 40%
Tubes with Max SVI < 20%
7 4
11 Tubes Plugged as a Result of SVI 2 2
0 2
40%
Tubes Plugged as a Result of AVB 6
1 7
Wear 2 37%
=_.
Tubes Plugged as a Result of an 0
1 1
Obstruction Tubes Plugged on a Discretionary 0
1 1
Basis
U.S. Nuclear Regulatory Commission B18942/Attachment 1/Page 8 TABLE 2: LOCATION OF TUBES PLUGGED FOR AVB WEAR SIZED 2 40% TW DURING MILLSTONE 3 RFO8 ASG l
C SG l
THROUGH THROUGH ROW COLUMN WALL -
ROW COLUMN WALL 35 58 41%, 39%,
41 61 44%, 45%
50____64__
40%
50 64 1
40%
TABLE 3: LOCATION OF DISCRETIONARY TUBES PLUGGED FOR AVB WEAR DURING MILLSTONE 3 RFO8 A SG ONLY ROW COLUMN THROUGHWALL 34 60 37%
42 99 38%, 38%
50 51 37%
51 63 37%
TABLE 4: LOCATION OF TUBES PLUGGED FOR SVI, OBS, OR PLP DURING MILLSTONE 3 RFO8 A SG CSG ROW COLUMN INDICATION ROW COLUMN INDICATION 4
122 SVI: 47%
1 4
SVI, PLP (preventive plug I
I___________
I___________
w /stab ilizer) 1 0 116 SVI: 64% _
1 115 OBS
VI U.S. Nuclear Regulatory Commission B18942/Aftachment lIPage 9 TABLE 5: TOTAL TUBES PLUGGED TO DATE SG A SG B SG C SG D TOTAL Fabrication 1
2 2
0 5
Preservice 2
1 1
1 5
RFOI 1
0 0
1 2
RFO2 4
0 4
RFO3 0
5 5
RFO4 6
1 0
7 RFO5 1 1 10 11 MID CYCLE 2
2 RFO6 12 2
14 RFO7 0
51 51 RFOB 8
- 3 11 TOTAL 34 4
1 1 J 68
.I 117
P.
Docket No. 50-423 B18942 Millstone Power Station, Unit No. 3 "A" Steam Generator AVB Indications
Millstone Unit 3 GROUP TUroES W1-19%TW Indications 90 Millstone Unit 3 1-19%TW Indications 3RO8 - 09/02 P
.A rvNsP mODuMO Von t.
S/G A HOT PRIMARY FACE TOTAL TUBES: 5626 SELECTED TUBES: 90 OUT OF SERVICE (#): NA SCALE: 0.080231 X Thu Oct 10 14:50:11 2002 Ths dranga W Xe OFP of FPrm010" ANP, h-AN W 6bnoud von
- W~
VW kI"i Ch r
" flobed roror Od, h
I te or M OAK or wed 1w fwhhl hkbowt to oh theor for amf lyor PuNrp deolmlm tI Ie W*ehiof runnyDom ANP WiiioVA bme ryd wn neuel._
o00000000000000 o00000000000000000000000oo0oo0 00000000000000000000000000000 90000OO 00000000000000000000000000000000 000000000 OOOO QOOOOOoo0ooooo000000O0000000000000000ooo0 000000000000000000 OOOOOOOOOOOOOOOOOOOwooooooooooooow 0000000000 00000000000000000000 0000000000000000000000000000W 000000000000 OOOOO00oooooOWOWOOQOOOOOOOOO(DOOOOOOOOOOOOOOOOOOOO 50 o 50 0000000000000000000000000000000000000000000000000000000000000000000000 000000008000000000080000000000000000000000000000000000000000000000000000000 WA,00 00 000000000 OOOOOOOOWOOOOOOOOOOQOOOOOOOOOO 00000000000000000000000000 ooooooooooooooooooooooooooooooooooooooooooooooooo00000000000000000000000000 woooooooooooooowooooooooooooooooooooooooooooooooooooooooooo000000000000000oooo OOWOOOOOOOOOOOOOOOooooooooooooooo0ooooo000000o00000000000000000000000000000000 oowooooooooPooooo~ooooooooooooooooooooooooooQooooooooooooooooooooooooooooooooooooo oooow00Owoooooooooooooooooooo~ooooooooowooooo0000000o00000ooo oooooooooooooooooooooo 00000o0000000o0000000woooooowoooooooooooooo~wooooooooo0oo00o000000o000000000o00o000000o00 08 4
0 00 0000ooooooowooo00wooo0ooooooooowoo0ooooo0ooooooooo00000000000000000 8 8 8 8 8 00 000000000000000000000oooooooooooooooooooooooooooooooooooooo00000000000000000000000000000000000 oooooooooooooooo oooooooooooooOOOwooooooowooooooooooooOOOOOooooooooooooooWooo 000000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000000000000 oowoooowoooooooow~ooooooooooooooooooo~wooooooooowoooooooowooovmooooooooowoooooooooooooooO00000000000 oooowoooooooowoooooow oooowoooo~oooooooooooo ooooooowooooooooooowooowoowooooooooooooooooooooooooowooo 00000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 oooooooooooo 000000000000000000000000ooooooo00000000o0000000000000000000000000000000oooooooooooooooooo ooooooooooooooooooooo00o000000000o0o0000000ooooooooo~woooooooooooooooooooopo00oooooQoooooooooooooQoooooo0 30 9
. G-- 30 woooooooooooooo000000000000000000000000*00o oOOOWOOOOOOOOOOOOOOO oooooooowooooO9ooo0ooooooooo0oooooo000000 00000o000000000 0000000000000000000000000 00o0000000000000000000o 000000008oooWo0000000ooooooooooooooooo0oo woo o000000000 0ooooooooooooooooooooooooooooo o
0000000000000000000000000000 00000000000000000000000000000000 ooooooooooooooooooooooooooooooooooooooooooooooo000000000000000000000000000000000000000000000000000000000000000 000000000000000000090000000000000000 80000000o000000000000000000000000000000000000000000000000000000000000000000 OWOOOOO0000000000000oooooooooooooooo0 000000000000000000000oooooooo0ooooooooo 0000000000000000000000000000000000 0088888000000000000 00 000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00000 00o000000000000000000000oooooooooowooooooooooo00000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000000000o000000000000000000000000000000000ooooooooooooooooooooooooooo00000000000000 000000000000000000000000000000000000000 000000000800000000080000000000000000000 0000000000000000000000000000000000000 0000000000000000000000000000000000000000 0000000000 000000000 000000000000000000000000000000000000000000000000000000000 20ooooooooo~ooooooooogo00000000o0000000000 0000000008000000000o0000000000000000000oo000000000o00000o000o0000000000000002 0000000000000 000000000 0000000 0000000000000000000000 000000000 0000000000000000000 0000000000000000000000000000000000000 00000000000 000000000000000000080 000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000800000000000000000000000000000000000000000000000000000000o000800000000000000000000 000000000000000000 00000000 00000000000000 00000000000000000000000000000000000000000000000000000000000000000000000000 10.0~00O00000 000000~00 0000ooooooooooooo0oo000000000000 00000000000 0000000090000000--00000000000 00000000~00000008. 00 ooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000080000000000000000000 00000o00000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000000 000000000000000000000 0000000000000000000000000000000000000000000000000000000000 ooooooooooooooooooooooooooooooo 0000000000 oooooooooooooooooooooooooooooooooooooooooooooooooooooo0oooooooooooooooooooooo oo0ooooooooo0oooooooooooooo00000000000000000ooo0000000o0000000000000000000000000000000000000000000000000000000000000000000 I
120 MANWAY 11 100 90 80 70 60 50 40 30 20 10 NOZZLE
Pramatome ANP Inc.
Customer Name: Millstone Unit 3 10/10/02 14:50:18 Component: S/G A Page I of 2 1-19 %TW Indications QUERY: 1-29%TW Indications ROW COL VOLTS DEG CNN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG 22 78 0.48 0.38 24 116 0.46 27 115 0.66 28 36 0.32 29 40 0.38 29 67 0.64 29 114 0.41 30 10 0.64 30 11 0.33 30 40 0.35 30 114 0.40 31 61 0.35 34 15 0.33 34 41 0.64 0.39 34 44 0.35 34 48 0.62 34 60 0.45 34 85 0.65 34 91 0.50 34 98 0.34 34 107 0.37 35 49 0.63 35 59 0.39 35 60 0.48 35 61 0.54 0.47 35 65 0.51 0.51 0.48 0.47 35 71 0.36 0.48 35 77 0.38 0.55 35 108 0.38 0.47 37 45 0.57 37 56 0.54 0.67 37 69 0.60 0.61 37 90 0.58 0.56 37 91 0.72 0.65 0.68 37 100 0.49 0.35 0.63 37 106 0.48 38 52 0.58 38 79 0.38 39 51 0.43 0.50 39 57 0.44 0.36 39 60 0.80 39 70 0.37 0.62 39 71 0.47 39 75 0.55 39 78 0.38 40 45 0.45 0.50 40 51 0.80 40 58 0.46 0.64 40 65 0.68 40 71 0.64 40 94 0.67 40 100 0.47 41 61 0.50 0.76 42 33 0.34 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 149 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
P 2 TWD 14 P 2 TWD 12 P 2 TWD 14 P 2 TWD 19 P 2 TWO 11 P 2 TWD 12 P 2 TWD 18 P 2 TWD 13 P 2 TWD 16 P 2 TWD 11 P 2 TWD 11 P 2 TWD 12 P 2 TWD 12 P 2 TWD 11 P 2 TWD 18 P 2 TWD 12 P 2 TWD 11 P 2 TWO 18 P 2 TWD 15 P 2 TWO 19 P 2 TWD 16 P 2 TWD 10 P 2 TWD 12 P 2 TWO 18 P 2 TWO 13 P 2 TWD 12 P 2 TWD 18 P 2 TWD 16 P 2 TWD 15 P 2 TWD 1S P 2 TWD 14 P 2 TWD 14 P 2 TWD 12 P 2 TWD 14 P 2 TWD 12 P 2 TWD 16 P 2 TWD 12 P 2 TWO 14 P 2 TWD 16 P 2 TWO 14 P 2 TWD 16 P 2 TWD 17 P 2 TWD 17 P 2 TWD 14 P 2 TWD 14 P 2 TWD 18 P 2 TWD 16 P 2 TWD 17 P 2 TWD 13 P 2 TWD 10 P 2 TWD 16 P 2 TWD 15 P 2 TWD 14 P 2 TWD 12 P 2 TWD 15 P 2 TWD 16 P 2 TWD 1S P 2 TWD 12 P 2 TWD 19 P 2 TWD 11 P 2 TWD 18 P 2 TWO 14 P 2 TWO 16 P 2 TWD 12 P 2 TWD 14 P 2 TWO 15 P 2 TWD 19 P 2 TWO 12 P 2 TWD 16 P 2 TWO 19 P 2 TWD 18 P 2 TWD 17 P 2 TWO 14 P 2 TWD 11 P 2 TWD 16 P 2 TWD 13
=..===t=f.se..==.=...====.
.===
==
AVS
+0.24 TEN TEC AV6
+0.05 TEN TEC AVS
+0.32 TEN TEC AV1
-0.22 TEH TEC AV5
-0.17 TEN TEC AV2
+0.00 TEN TEC AV2
-0.03 TEN TEC AVS
+0.11 TEN TEC AVS
-0.03 TEN TEC AVS
-0.03 TEN TEC AV2
-0.16 TEN TEC AV1
-0.03 TEN TEC AVS
-0.19 TEN TEC AV6
-0.08 TEN TEC AV3
-0.08 TEN TEC AV4
-0.11 TEN TEC AV3
+0.23 TEN TEC AVI
-0.10 TEN TEC AV2
-0.08 TEN TEC AV5
-0.11 TEN TEC AV2
+0.03 TEN TEC AV4
+0.13 TEN TEC AV4
-0.03 TEN TEC AV5
-0.24 TEN TEC AV3
+0.27 TEN TEC AV5
-0.03 TEN TEC AV4
+0.11 TEN TEC AV2
-0.19 TEN TEC AV2 t0.16 TEN TEC AV4
-0.05 TEN TEC AV5
-0.03 TEN TEC AV3
+0.08 TEN TEC AV6 40.00 TEN TEC AVS
-0.25 TEN TEC AV2
+0.11 TEN TEC AV4
-O.OS TEN TEC AV2
-0.08 TEN TEC AV3
-0.08 TEN TEC AV3 t0.22 TEN TEC AV3
.0.03 TEN TEC AV4
+0.10 TEN TEC AVS
-0.05 TEN TEC AV6
-0.08 TEN TEC AVS
+0.14 TEN TEC AV4
+0.03 TEN TEC AV6
-0.06 TEN TEC AV4
-0.19 TEN TEC AV3
+0.03 TEN TEC AVS
-0.16 TEN TEC AV4
-0.25 TEN TEC AV3
-0.22 TEN TEC AVS
-0.03 TEN TEC AV2
+0.26 TEN TEC AV6
-0.13 TEN TEC AV4
.0.16 TEE TEC AV3
-0.08 TEN TEC AV3
+0.05 TEN TEC AVI
+0.11 TEH TEC AV4
+0.05 TEH TEC AV2
+0.11 TEH TEC AV3
+0.03 TEN TEC AVS
-0.19 TEE TEC AV5
-0.08 TEN TEC AV3
-0.05 TEN TEC AV3 t0.13 TEN TEC AVs
-0.05 TEN TEC AVS
+0.03 TEN TEC AV2
-0.16 TEN TEC AV3
-0.16 TEN TEC AV2
-0.08 TEN TEC AV2
.0.05 TEN TEC AV5
-0.05 TEN TEC AV3
-0.13 TEN TEC AV3 40.03 TEN TEC AV4
.0.03 TEN TEC AV4
+0.00 TEN TEC
==s
g=-r=
24 24 48 49 8
8 25 48 4
3 7
48 27 3
29 29 28 28 27 32 32 34 49 28 27 26 27 27 25 25 25 25 25 25 25 25 49 49 29 26 26 25 25 33 33 33 33 33 35 35 35 49 26 24 27 27 27 27 26 25 25 25 25 24 28 28 26 26 26 24 24 34 48 19 19 16 COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE
- ===w==a:
56OUL 56OUL 56OUL 560UL 560UL 56OUL 560UL 56OUL 56OUL 56OUL 56OUL S60UL 56OUL 56OUL S60UL 56OUL 560UL S6OUL 56OUL 56OUL 56OUL 56OUL 56OUL S60UL 560UL 56OUL 56OUL 56OUL 56OUL 56OUL 560UL 56OUL 56OUL 56OUL 56OUL 56OUL 56OUL 56OUL S60UL 56OUL 56OUL 56OUL 56OUL 56EUL 56OUL 56OUL 56OUL S60UL 56OUL 56OUL 56OUL 56OUL 56OUL 56OUL 56OUL 56OUL 56OUL S60UL 56OUL S60UL S60UL 56OUL 56OUL 56OUL 56OUL 56OUL 56OUL 56OUL 56OUL 56OUL 56OUL 56OUL 56OUL S60UL 56OUL
Framatome ANP Inc.
Customer Name: Millstone Unit 3 10/10/02 14:50:18 Component: S/G A Page 2 of 2 1-1
%TW Indications QUERY: 1-19%TW Indications.qry ROW COL VOLTS 42 37 0.48 42 43 0.53 0.46 42 63 0.65 0.44 42 77 0.41 42 93 0.49 0.72 42 101 0.61 43 64 0.43 0.44 0.70 43 80 0.34 0.60 v 43 87 0.65 0.32 43 98 0.58 0.40 43 99 0.69 43 101 0.44 44 64 0.54 44 74 0.44 0.67 0.62 44 75 0.34 44 96 0.45 0.64 0.41 44 98 0.36 45 99 0.51 0.62 46 99 0.63 47 71 0.33 47 98 0.30 47 99 0.56 50 44 0.40 50 64 0.36 50 76 0.65 50 82 0.58 0.66 0.56 50 86 0.51 50 87 0.57 50 90 0.51 0.51 SI 63 0.27 0.54 51 65 0.56 51 66 0.37 53 33 0.71 0.35 53 81 0.45 54 35 0.70 54 49 0.52 DEG 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0*
0 0
0 0
0 0
0 0
0 0
0 0
0 CHN IND %TW LOCATION P 2 TWD 13 AV2
-0.03 P 2 TWD 17 AV2 40.08 P 2 TWD 16 AV3 40.11 P 2 TWD 14 AV3
+0.18 P 2 TWD 10 AV4
+0.03 P 2 TWD 12 AV3 40.05 P 2 TWD 12 AV3
-0.18 P 2 TWD 18 AV4
-0.05 P 2 TWD 17 AV2 40.00 P 2 TWD 10 AV3 O0.oo P 2 TWO 10 AV4
+0.08 P 2 TWD 15 AV5
-0.13 P 2 TWO 11 AV5
-0.06 P 2 TWD 18 AV6
+0.03 P 2 TWD 19 AV2
+0.14 P 2 TWD 11 AV3 40.08 P 2 TWD 15 AV4
+0.03 P 2 TWD 10 AV5
-0.03 P 2 TWD 19 AV4
+0.00 P 2 TWD 14 AV3 40.00 P 2 TWO 18 AV3
+0.00 P 2 TWD 12 AV4
+0.00 P 2 TWO 17 AV5
+0.24 P 2 TWD 16 AV6
+0.08 P 2 TWD 10 AV3
+0.05 P 2 TWD 14 AV2 40.00 P 2 TWD 19 AV4
+0.00 P 2 TWD 13 AV5
-0.11 P 2 TWD 12 AVI
+0.03 P 2 TWD 15 AV5 40.00 P 2 TWD 18 AV4 40.00 P 2 TWD 18 AVS
+0.06 P 2 TWD 12 AV2
+0.11 P 2 TWD 10 AV3
-0.03 P 2 TWD 17 AV6 40.00 P 2 TWO 12 AV4
+0.21 P 2 TWD 13 AV6
-0.14 P 2 TWO 17 AV3
-0.05 P 2 TWD 15 AV2
+0.00 P 2 TWD 17 AV3
-0.10 P 2 TWD 14 AV4
-0.16 P 2 TWD 13 AV2
+0.00 P 2 TWD 14 AV5
-0.11 P 2 TWD 13 AV5
-0.08 P 2 TWD 13 AV4
-0.13 P 2 TWD 11 AV5
+0.00 P 2 TWD 18 AV3
+0.00 P 2 TWD 19 AVS
-0.16 P 2 TWD 9 AV3
+0.26 P 2 TWD 18 AV4
+0.03 P 2 TWD 10 AV6
-0.05 P 2 TWD 14 AVI
+0.06 P 2 TWD 18 AVS
-0.03 P 2 TWD 17 AV2
+0.05 EXT EXT UTIL 1 UTIL 2 T=D TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH TEC TEN TEC TEN TEC TEN TEC TEH TEC TEH TEC CAL #
15 18 18 19 19 23 30 30 47 19 19 19 31 31 31 31 30 30 46 46 20 23 23 23 23 31 31 31 31 46 46 47 22 47 46 17 20 23 30 30 30 30 30 30 30 20 20 20 19 15 15 31 15 18 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 56OUL 56OUL 56OUL 560UL 56OUL S5OUL S60UC 560UC 56OUL 56OUL 56OUL 56OUL 56OUL 560UL 56OUL 56OUL 56OUL 560UC 560UC 560UL 56OUL 560UL 56OUL 560UL 560UL S60UL 560UL 560UL 56OUL 56OUL 56OUL 560UL 56OUL 56OUL 56OUL 560UL 56OUL S60UL 560UL 56OUC 56OUC 560UC 56OUC 560UC 56OUL 56OUL 560UL 56OUL 56OUL 560UL 56OUL 56OUL S60UL 560UL 560UL Total Tubes 90 Total Records: 130
GROUP TUB*TS Millstone Unit 3 W20-36%TW Indications 54 20-36%TW Indications 3RO8 - 09/02 S/G A TOTAL TUBES:
5626 SCALE: 0,080231 X HOT SELECTED TUBES: 54 Thu Oct 10 14:52:24 2002 PRIMARY FACE OUT OF SERVICE(#):
NA mn.
_.0 _
Nr oooooooooooooo ~
~
~
~
(Or~"o 10Moowwo-m~e~ms ft Onqroft aIFfamowns ANP ond wil b* ek~U~ upon mgovst.
00000000000000 000000000000000000000000000000 ooooooooooooooooooooooooooooooooooooooo 000000000000000000000000000000000000000 OOOOOOOOOOOOOO0000OOOOOOOOOOO OOQOOOOOOOOOOOOOOO OOOOOO 0000OO0000000000000000000000000000000000000000000 000000 000000000000000$0000000000000000000000000000 ooo 0000000000000000000 00~0000000000000000000000 0
OOOOOOOOOOOO5OOOOO O00000000W000oW 000000 000 000(00000000060 50 5000000000000,00e-40.OOo~o ooooooooooooo0000 0o~oooooooooooooooooo ooooooeooooooowooooooooooooooooooooooooe.4 OOWOOOOO 000 000O 0O000 000000000000000000000000000000000000000000000000000000000000009000 00000OO QOOOOOOOOOOOOOOOOOOooO00oooooo0000 0
000ooooooo0o0o00 oooo0Ooooooooooo oo8W88888 0000000008 00000000800000000000000000008088880 000 00000000 0080880000000000000000 000000000000000 000000000 000000000000000000000000000000000000000 0000000000000000000000000000 oooooooooooooooooooooowo o
o00000000000000 000000000000 0000000000000000000000000000 oO OOO000000000ooooo0000oo0ooooooooooooooo0ooo0oo0000000 0000000000 00000000000000000000000000000 00000 000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00 0 ooo0 ooooooooooooooooo000000000000000000000000000000000000000000OOOOOOOOOOOOOO00000000000 00000 oo~oooooooooQoooooQOOQOOOOOOQOOOOOOOOWooooooowoooooooooooooooooo000000000000000 00000000000000000000 ooooooo 000000oooooooooooooooo oaoooooooooooooooooooo w
ooooooooooooooooo~ooooooooooooooooooooooooooo OQw0o00OOQOOOOOOOOO oooooooooooooooooo0oooooooooooo000000000o0ooooooooooooooooooooooooooooooooooooo 0000000000000000000000000000000200000000000000000000000000000000000000000000000000000000000000000000 3000ow000000000000000000000000000000000000000000000000000000000000800 000000000000000000000000000000000000000000o 0000000000000000000000000000000000000 00000000000000000000000000000 0000000000000000000000000000000000000000000 oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo ooooooooooooooooooooooooooooooooooooooooooo
- 000000000000000000~000000000..00000000000000000000~000000000e0000000000 0000000000000o 000000 000.0000000000000000000~1 WOOOOOOOOO000000000000000000000000000000000000000000000000000;00000000000000000000 0000000000 0000000000000000 08888 0008 008 008 008 00888888880000 888 88800000000 00000000000000000000000000000 0000000000000000 0000ooo 0000~00OO000 O00000000000000000%000000000000000000000000000000000000000000000000000 000000000O g000 0000000O 00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000080000000 0000000OOOOOOOOOOOOO800000000%000000000000000000000000000000000000 0000 000000000800000000080000000000O000OOOO00o0oo oo o 00000000 0000000000000000000
$o000000000 00000000gOg0oo Oo000ooo000o 00ooo0oooooooooooooooooooooooooooooooo0$0888888 00000000o000000000o000000000o000000000o000000000o000000000o000000000oooooooooooooooooooQOOOOOOOOOOO00000000oo0000 120 10109 07 05 03 01 00000000MA00000000N000000000o000000000o00000WAY0 o000000000o000000000o000000000o000000000N000000000O ZZLE oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo0 0000000000o00000000080000000000000000000o0000000000000000000o000000000o000000000o00000000080000000000000000000800QO000 o 00000000000000000000 00000000000000000000000000000000000000000000000008000000000000000000000000000000000000000 0000oooo o000000000000000000000000000000000000000000000000000000000000000000000090000000000000000000 0000000000000000000000000000 00000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000 0000000000000000000000000000 0000000 000000000o000000000 0000000000 000000000000000000000000900000000o00o090000000000000o000000000o00000o0-ooooooovoooooose 0080000000008000000000000000000080000000800008888800000000000088000080008888800000 00888880000000888888888888888888880g88 00o000000000o000000000o000000000 000000000 000000000o000000000000000000080000000000000000000o000000000 000000000000000000 oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo 00oo0000000ooo0000000o000000000 000000000 000000000ooo0o00000o000000000o000000000oooo0000000oo000000000o0000000ooooo0oooooo 120 110 100 90 so 70 60 50 40 30 20 10 MAN W.AY NO ZZLE
a ft Framatome ANP Inc.
Customer Name: Hillstone Unit 3 10/10/02 14:52:28 Component: S/G A Page 1 of 2 20-36 %TW Indications QUERY: 20-36%TW Indications ROW COL VOLTS 26 115 1.11 28 115 1.38 30 9
1.49 30 113 0.98 32 111 0.77 0.85 34 46 1.35 1.52 34 48 0.73 1.42 34 60 1.25 0.99 34 73 1.27 1.73 34 109 1.28 35 58 1.12 0.87 35 59 0.70 1.09 35 60 0.84 35 71 0.93 35 77 0.74 37 45 1.18 0.75 37 90 1.01 37 91 1.19 37 106 0.73 38 106 0.75 0.80 0.95 39 57 0.64 1.44 39 71 0.99 40 45 1.19 40 65 1.84 0.82 40 71 0.73 1.01 41 102 1.29 42 33 0.87 42 53 0.87 42 77 0.91 42 93 0.87 42 98 1.49 1.69 42 99 0.68 42 101 0.93 1.25 42 102 1.23 1.74 0.82 43 80 0.80 0.92 43 87 0.92 0.93 43 101 0.75 0.81 43 102 0.79 0.71 44 60 2.36 1.25 1.41 44 64 1.12 44 98 1.10 0.73 45 98 0.96 50 44 0.98 50 50 0.75 50 51 0.66 0.67 50 64 0.81 0.89 1.13 50 76 0.90 50 87 0.92 50 90 1.67 DEG 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 CHN IND %TW P 2 TWD 26 P 2 TWO 30 P 2 TWD 32 P 2 TWO 24 P 2 TWD 21 P 2 TWO 22 P 2 TWD 29 P 2 TWD 32 P 2 TWO 20 P 2 TWO 31 P 2 TWD 31 P 2 TWD 27 P 2 TWD 28 P 2 TWO 34 P 2 TWO 29 P 2 TWO 29 P 2 TWD 25 P 2 TWD 21 P 2 TWD 28 P 2 TWD 20 P 2 TWO 24 P 2 TWD 20 P 2 TWD 27 P 2 TWO 20 P 2 TWO 23 P 2 TWO 26 P 2 TWO 20 P 2 TWD 20 P 2 TWO 21 P 2 TWO 24 P 2 TWD 20 P 2 TWD 33 P 2 TWD 24 P 2 TWO 28 P 2 TWO 35 P 2 TWO 21 P 2 TWD 20 P 2 TWO 25 P 2 TWD 29 P 2 TWO 26 P 2 TWD 25 P 2 TWO 22 P 2 TWD 21 P 2 TWO 32 P 2 TWD 34 P 2 TWO 20 P 2 TWO 23 P 2 TWD 27 P 2 TWD 29 P 2 TWD 35 P 2 TWO 22 P 2 TWO 22 P 2 TWO 24 P 2 TWO 24 P 2 TWD 24 P 2 TWD 21 P 2 TWO 22 P 2 TWD 21 P 2 TWD 20 P 2 TWD 36 P 2 TWD 24 P 2 TWD 26 P 2 TWD 29 P 2 TWO 27 P 2 TWO 21 P 2 TWD 24 P 2 TWD 24 P 2 TWD 22 P 2 TWD 21 P 2 TWD 21 P 2 TWD 24 P 2 TWD 25 P 2 TWO 29 P 2 TWD 22 P 2 TWD 22 P 2 TWD 33 LOCATION AVI
-0.37 AVI
-0.40 AV5
+0.0 AV5
+0.17 AVS
+0.00 AV4
+0.00 AVS
-0.03 AV6
+0.08 AV2
-0.05 AV3
-0.03 AV3
+0.00 AV5
+0.00 AV4
+0.24 AVS
-0.16 AV4
+0.00 AV2
+0.05 AV6
+0.11 AV6
-0.11 AV2
+0.33 AV4
+0.03 AV4
+0.19 AV3
-0.03 AV2
+0.03 AVS
-0.19 AV3
+0.08 AV5
-0.08 AV4
-0.14 AVS
+0.00 AV4
-0.08 AV3
+0.00 AV4
+0.08 AV2
-0.05 AV4
+0.27 AV4
+0.05 AV4
-0.05 AV5
-0.18 AV3
-0.16 AV4
-0.18 AV4
+0.03 AV3
+0.05 AV4
-0.06 AV4
+0.05 AVS
-0.05 AV3
+0.03 AV4
+0.08 AV5
+0.00 AV4
+0.03 AVS
+0.00 AV5
+0.00 AV4
+0.00 AV3
+0.00 AV3
-0.03 AV4
-0.03 AV4
- 0.00 AV5
-0.08 AV5
.0.00 AV4
+0.00 AV5
+0.00 AV4
.0.00 AV2
+0.21 AV3
+0.00 AV4
+0.16 AV2
+0.00 AV2
+0.00 AV4
+0.00 AV4
.0.03 AV5
-0.08 AV4
-0.14 AV5
-0.17 AV3
.0.00 AV4
+0.11 AV3
-0.11 AV2
+0.00 AV2
+0.05 AV2
-0.11 AV2
-0.05 EXT EXT TE= TEC TEH TEC TEH TEC TEH TEC TER TEC TEH TEC TEH TEC TEH TEC TEE TEC TEE TEC TEH TEC TEH TEC TEN TEC TEH TEC TEE TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEE TEC TEH TEC TEE TEC TEH TEC TEH TEC TEH TEC TEH TEC TEE TEC TEH TEC TEE TEC TEH TEC TEH TEC TEE TEC TEH TEC TEH TEC TEH TEC TEH TEC TEE TEC TEE TEC TEH TEC TEH TEC TEH TEC TEE TEC TEH TEC TEE TEC TEH TEC TEH TEC TEH TEC TEE TEC TEH TEC TEE TEC TEH TEC TEE TEC TEE TEC TEE TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEE TEC TEE TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEE TEC TEE TEC TEH TEC UTIL 1 UTIL 2
-s===s CAL # LEG 48 COLD 48 COLD 3
COLD 49 COLD 48 COLD 48 COLD 29 COLD 29 COLD 28 COLD 28 COLD 27 COLD 27 COLD 24 COLD 24 COLD 48 COLD 27 COLD 27 COLD 27 COLD 27 COLD 26 COLD 25 COLD 25 COLD 29 COLD 29 COLD 33 COLD 33 COLD 49 COLD 48 COLD 48 COLD 48 COLD 27 COLD 27 COLD 25 COLD 28 COLD 24 COLD 24 COLD 24 COLD 24 COLD 47 COLD 16 COLD 20 COLD 23 COLD 30 COLD 31 COLD 31 COLD 31 COLD 47 COLD 47 COLD 46 COLD 46 COLD 46 COLD 31 COLD 31 COLD 31 COLD 31 COLD 46 COLD 46 COLD 46 COLD 46 COLD 19 COLD 19 COLD 19 COLD 20 COLD 31 COLD 31 COLD 47 COLD 17 COLD 18 COLD 20 COLD 20 COLD 20 COLD 20 COLD 20 COLD 23 COLD 30 COLD 30 COLD PROBE 56OUL 56OUL 56OUL 56OUL S60UL 56OUL S60UL 56OUL 56OUL S6OUL 560UL S60UL 560UL 56OUL 56OUL 560UL S60UL 56OUL S6OUL 56OUL S6OUL 56OUL 56OUL 560UL 56OUL 560UL 56OUL 56OUL 56OUL 56OUL 56OUL S60UL 56OUL 56OUL 56OUL 56OUL 560UL S60UL S6OUL 56OUL S60UL S60UL 56OUC 56OUL 56OUL S60UL 560UL S60UL S60UL 56OUL 56OUL S6OUL 56OUL S60UL 560UL 56OUL S60UL 56OUL S60UL 560UL 56OUL 56OUL S5OUL 56OUL 56OUL 560UL 56OUL 56OUL 56OUL 56OUL 56OUL 56OUL 56OUL 56OUL 56OUC S6OUC
Framatome ANP Inc.
Customer Name: Millstone Unit 3 10/10/02 14:52:28 Component: S/G A Page 2 of 2 20-36 %TW Indications QUERY: 20-36%TW lndications.qry ROW COL so 91 VOLTS 1.49 1.44 1.24 0.72 1.05 1.94 1.38 DEC CHN IND %TW 0
P 2 TWD 31 0
P 2 TWD 30 0
P 2 TWD 27 0
P 2 TWD 22 0
P 2 TWD 28 0
P 2 TWD 35 0
P 2 TWD 31 LOCATION EXT A2======2==s=2=2T======R==
2 AV3
-0.08 TEN AV2
-0.08 TEH AV3
-0.11 TEN AV4
+0.27 TEN AV4
+0.00 TEH AV5
-0.03 TEH AV3
+0.03 STE EXT UTIL I UTIL 2 TEC TEC TEC TEC TEC TEC TEC CAL J 30 30 30 20 20 15 31 LEG COLD COLD COLD COLD COLD COLD COLD PROBE
- =....
56OUC 56OUC 560UC 56OUL 56OUL 56OUL 56OUL 51 52 53 53 63 66 33 81 Total Tubes
- 54 Total Records: 83
GROUP TUBES Millstone Unit 3 W37-100%TW Indications 6
37-1 00%TW Indications 3RO8 - 09/02 FA-AiP. '1P.
madlS e Ve oo.
S/G A TOTAL TUBES: 5626 SCALE: 0.080231 X HOT SELECTED TUBES: 6 Thu Oct 10 14:53:02 2002 PRIMARY FACE OUT OF SERVICE (#): NA =
We Interestofi Flremstorm ANP VW AIt be ret~uponette request.
00000000000000 oo8888 0000000000008 00000000000000o o
o 000000000000000000000000000000000000000000 oooooooooooDPooooooooooooooooooo ooooooooooooooooooooooooooo0 o
°
°
°
°
°
°
°
° o
oo000000000000000000000000 0000000000000000000000oo i j0,000800 0 000000000000000000000000000000000000000000000 10 60 s0000 0
00 0 0 0 4ee000 0 000 000 00 0 000 02010 00000000000000000000000000000~0000000000000000000000000000000000000008000000 0000000000000000000000000000000 0000000000000000000000000000000000000000000000o 00o000000008000000008000000000888000000000000000000000000000000000000000000000000 000 00000000000000 00000000000000000000000000000000000000000000000000000000 0800088088888088 0000000000oo000000000000000000000000000000o00000000000ooo000000000000000000 00000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~4 000000oQOeOOeOOeOee O000000o00000000e00000000e00000000e0000000e000000000000000e0*000 000000000 0000000000000000000000000000 0000000000000000000000: 00000000000000000000000000000000000000 00000000000000000000000000000000000000 00000000000000000000000 00000000000000000000000000000000000000 0000000080000000000000000000080800 000 0000000000000000000880000008008080008008000800800000000000000000000000 00000000 0000000000 00000000000000000000000000 oooooooooo0 00000000000000000000000 OOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOooOOoooooooooooooooooooo0000oo0000000 OO0o0000000 ooo 000000000000088oooo8o8oooooo0000000000O00000000088000000000000000000oo00000000oo0000000 ooooo 8
ooooooo oooOOQOOOOOOOO 000000000000O000008000000000000O0000000 0OO0 10
.0~0000000O000000O 0000000000000 00000000000 100000000 0000000000O0000000001000000000~0000000009000000000~0000000000~00000000000000000000 000000000~00000000000000000000000000o 120 1120008 0605 03 01 MAN 0000 WAY0000000 NOZZLE000 MANWAY NOZZLE
7 Framatome ANP Inc.
Customer Name: Millstone Unit 3 10/10/02 14:53:08 Component: SIC A Pag~e I of I 37_100 Ind s
A 37-100 %TW Indications OUERY: 37-100%TW Indications ROW COL VOLTS
.===z..
34 60 1.90 35 58 2.07 2.38 2.26 42 99 2.11 2.11 50 51 1.84 50 64 2.25 51 63 1.87 DEG 0
0 0
0 0
0 0
0 0
CHN IND %TW
.=..
P 2 TWD 37 P 2 TWD 39 P 2 TWD 41 P 2 TWD 40 P 2 TWD 38 P 2 TWD 38 P 2 TWD 37 P 2 TWD 40 P 2 TWD 37 LOCATION EXT EXT UTIL 1 UTIL 2
AV4
-0.03 TEH TEC AV4
+0.00 TEH TEC AV3
+0.00 TEH TEC LAR AVS
+0.23 TEH TEC LAR AV3
-0.05 TEH TEC AV4
-0.08 TEH TEC AV4
-0.03 TEH TEC AVS
-0.16 TEH TEC LAR AV2
+0.27 TEH TEC CAL # LEG
-s..s t=======
27 COLD 27 COLD 27 COLD 27 COLD 31 COLD 31 COLD 20 COLD 20 COLD 20 COLD PROBE 56OUL 560UL 560UL 56OUL 560UL 56OUL 56OUL 56OUL 560UL Total Tubes
- 6 Total Records: 9
Docket No. 50-423 B18942 Millstone Power Station, Unit No. 3
'A" Steam Generator Volumetric Indications
- v GROUP TUBS M illstone U n it 3 V
VOL Indications 25 VOL Indications 3RO8 - 09/02 FRA.ANP. FOWS mao,edufl VqbV 2.1 S/G A TOTAL TUBES: 5626 SCALE: 0.080231 X HOT SELECTED TUBES: 25 Thu Oct10 15:51:47 2002 PRIMARY FACE OUT OF SERVICE (#): NA
_ " 4 bo RNv.ft" Womsst to 0, tof l
or8*W DwOU demet" to vie iterst of rr P
o~etOP ANP and wfil be rehmdtwyv nuw request.
00000000QOOOOO 000000000000000000000000000000 0000000000000000000000000000000000000000000 0
0 00000000o0000000000000000000000ooooo00ooooooooooo0oooo00000000000000000000 00 00v0000000000000000000000000000000000000000800000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000000000000 ooooovoooooooooooooooooooooooooooooooooooooooooooooo00000oo0000008000000o 0000000000000000000000 800000000000000000000000000000000000000000000000000000000000 0000000~ggooooo00 00000000000000000000000000000000000000000000000000000800000000%
08888o88888oo$888o88$888oog888888888888888 88$8e888 088888888o888 08 0 o$$
40OO-oOoooooooooooooooooooooooo0000oo 000oooooooooooooooooooooooooooooooo00oo0oooooo v
0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000OOOO0 00000000000000000000000000000000000000000000000000000000000000000000000000000000000000 OOOOCOOO0O0OOOQO0OO00000000000000 0000000000000000000 0000000?00000000000 00000000080 OOOOO00 OOOOOOOOO0OOO000000000000000090000 00000000000000000000000 0000000000000000000VOOOOOOOO 30 oovooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooovehosooooooooooooooooooooooooooe430 ooooooo00000000000000000000000000000000000 ovoooooooooooooooooooo 00000000000000000000000oooooooo0ooooo0 o
o o
o oo00000000o o00000000o00000000000000000 0000000000000000000000: 0000000000000000000000oooo0ooooooooooo0 000000000000 08 00000000OOOOOOOOOOO 0000000000000000000000000000000ooooooooooooooooooooooo oooooooooooooooooooooooooooooooooo J00 000 000000000000000 00000000000 0000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000090000000008000000000000000000000000000000000000000 0000000 00000000000000oooooovoo 00000000000000000000000000000 000000000 0000000000000000000 OOOOQOOOOO00000000000000000000000 00000000000000 0000000000008000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000 oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo 0000000000000000000000000000000 20 2
00000000000000000 0000000000000000000800 000000000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000 0000000 0000000000000000000000000000000000000000000000000000000000000000000000000 00000 10 o oooooooooooooooooooooooooooooooooooo ooooooooooooooooooooooooooooooooooooooooooooo0000000000000000000000000 ooooooo0oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo ooooooo ooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo 80000000000000000 ooooooooQooooooooooooooooooooooooooooooooo0oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo 00000000000000000000000000000000000000000o0000000000000000000000000000000000000ooooooooooooooooooooo00000000000000 20 110 100 90 80 70 650 40 30 20 1020 00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000A00WAY0NOZZ0E 00000000000000000000000000000000000000000000000000000000000(000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000000000000000000000000000000000000000000o00000000000000000000000000000000000000000 00000000000000000000000000000080000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000O00000000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000 10 50s0000000000000v0000000000v0000e0000o0000o000--oooooooooosoooe10 00000000000000000000o0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00000000000 000000000 0000000000000000000000000ooooooooooooooooooo0000000000000000000000000000000000000 000000000000000000 00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000800000000000000000000000000000000000000000000000000000000000000000000000000000000 000000000000800000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00o000000000 000000000 000000000o0 0000000o000000000o000ooooooooovoooooooooooo0000o000000000oo00000000o00000o000o000000000 00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00TOO00000000900000000000000000000000000000TOO0000000900o0VOOOOOmOOOOOOOOOO 0000000000000000000000000000000000000OT0000000000 120 110 100 90 80 70 60 50 40 30 20 10 MANWAY NOZZLE
Framatome ANP Inc.
Customer Name: Millstone Unit 3 10/10/02 15:51:51 Component: SIG A ID-e I of I
COLrIndt Yc A
VOL Indications QVERY: VOL Indications ROW COL VOLTS 1
66 0.12 3
57 0.90 10 119 0.60 28 100 0.17 29 71 0.14 31 25 0.71 34 17 0.66 35 16 1.98 35 105 0.67 35 107 0.93 36 24 1.03 38 26 2.72 39 21 1.08 40 30 0.32 40 34 0.48 41 42 1.71 46 91 0.74 49 64 0.46 49 77 0.92 0.85 0.67 0.76 49 92 3.20 51 38 0.76 54 50 0.22 54 62 0.47 55 41 0.19 55 69 0.25 DEG 113 85 69 S
142 107 61 112 90 87 97 157 111 88 36 114 93 26 86 73 73 78 11 82 75 70 89 115 CNN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL I
=-
=
-s =
==
=
==s s
e
=====-
=
r
4 3
3 4
4 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
I 3
3 3
3 3
3 3
VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL VOL TSC 02H TSH 011 01H 06C TSN 02H TSC TSC TSH 03H TSC TSH 08H 06N 04C 03C TSH 05C TSH TSH TSH TSH TSH 02C TSC TSH
+4.12
+12.25
+3.17
+8.79
+0.08
+22.76
+0.67
+24.11
+3.21
+4.81
+7.47
+0.34
+1.99
+2.44
-0.06
+35.94
+6.37
+34.98
+3.28
+2.19 42.93
+3.28
-1.05
+7.81
+2.23
+25.55
+4.03
+5.31 TSC TSC 028 03H TSH TSH 0lH 02H 01H 02H 06C 07C TSH TSH 02H 03H TSC TSC TSC TSC TSH TSH 031 03H TSC TSC TSH TSH 08H 08H 06H 07H 04C OSC 03C 04C TSH TSH 05C 06C TSH 01H TSH TSH TSH TSH TSH TSH TSH TSH 02C 03C TSC TSC TSH TSH 86 38 39 67 67 64 7
67 74 74 68 67 67 7
67 38 64 64 79 83 36 73 24 68 12 64 78 72 LEG COLD HOT HOT HOT HOT COLD HOT HOT COLD COLD HOT HOT COLD HOT HOT HOT COLD COLD HOT COLD HOT HOT HOT HOT HOT COLD COLD HOT PROBE 56OPP 56OPP 560PP 56OPP 560PP S6OPP 560PP 56OPP 560PP 560PP 560PP 560PP 560PP 560PP 560PP 56OPP 56OPP 56OPP 56OPP 56OPP 56OPP 560PP S60PP 560PP 560PP 560PP 560PP 560PP 56 0PP HR Total Tubes
- 25 Total Records: 28
Docket No. 50-423 B 18942 Millstone Power Station, Unit No. 3 "A" Steam Generator Sinole Volumetric Indications
GROUP TUBfS Millstone Unit 3 W1-19%TWforSVI 10 1-1 9%TW for SVI 3RO8 - 09/02 tttANP. PINo ma modsie Veb 2.
S/G A TOTAL TUBES: 5626 SCALE: 0.080231 X HOT SELECTED TUBES:
10 Thu Oct10 15:48:54 2002 PRIMARY FACE OUT OF SERVICE(#):
NA 0,0 W*tgl of Pramato"ii ANP ar~~
4 w
C~iN b *%
0upo r~uesI.
00000000000000 000000000000000000000000000000 000000000000000000000000000000000000 OO0000000000000000000000000000000000000000o oooooooooooooo(oooo0oooooooooooooooooooooooogo 00000000000000OOOO00000000000000000000000000000000000 000000000 00000000000 000000000000000000000Q00 00000 00000000 00000000000000000000000000000000000000000000000000000000000000 50s oo0ooooooooooooooooo ooo ooooooooooo 50 000000OQOOOOOOOOO0OOOO0000030000000000000000000000000000000000000000000 00000000 000000000000000000000000000000000000000000000000000000000000000000 0000000000 00000000000000000000000000000000000000000000000000000000000000000o 0000000000000000000000000000000000000000000000000000000oooooooooooooooooooo0 00000000000000000000000000000000000000000 000000000000000000000000000000000000000 0000000000000000000000000000000000000000000 00000000000000000000000000000 0000000000 oooooooooo0000000000000000000000000000000000000000000o000000000000000000 40 00 0oooooo00o00ooo00oo0o000oooooooooooooo0ooo00oooooooo~oooo o
o e-4 0
000000000o000000000000000000000000000000000000000000000000000 0
00000000000000 000000000 000000000 000000000000000000000000000000000000000000000000000000 000000000000000000 000000000000000000o0000000000o00000000000000000000000000000000000000000000 00000000000000000000000000000000000000000 00000000000000000000000000000000000000000000000000000000 000000000000800000000000000000008000000000 000000000000000000000000000000000000000000000000000000000 000000000 0000000000000000000 000000000 000000000000000000000000000000000000000000000000 000000000 0000000000800000000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000o 0000 00000OO000~000000000
~0000000000000000000000000000000o000000000000
.~-000000000000000000000000000000000000 0000000000000000 0000000 00000 00000000000-3 OOWOOOOOOOOOOOOOOOOOOOOQOOOOOOO000000000000000000poooo0000000000:000000000000000000000000000000 0000000000 000000.0000000000000000000000000000000000 0000000000000000000000: 00000000000000000000000000000000000000000 0000000000oooooooooooooooooooooooooooooooooooooooooooooo0000:oooooooooooooooooooooooo 000000000 000000000000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000O000000000O0000000000000000000OO000000000O0O000O000O000000000O0OOOOOOoopooO 00000000000000000 000000000008000000000000000000000000000000000000000000000000000000000000000000000000000000000000 20 20 00000000000000000080000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000 000000000080000000000000000000000000000000000000000000000000000000000000000000o0000000000000000000 00O0000000000000000% 00000000000 000000000000000000000000000000000000000000000000000000000000000000000OOOOOOOOOOOOOOOOWO 000000000000000000000000000000000 000 0000 000oooooooooooooooooooooo00000000000000OOOOOOOOOOOOOOOOOO WO000000000008000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000000 v00000000 g000000000 g0000000000000000000000000000000 00000000 00000000000000 120 110 100 90 80 70 60 50 40 30 20 1~~~~~~~~~~~~~000 0 e
-1 MAN OOOOOOOOOOO0040 WAY8NO8ZL80E0000000800000800000000080 00 80000000003000000000000 0
00000000000000000000004 000000000000000 00000000 000000000 000000000 000000000 000000000 0000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000TOOOOOOOOOOOOOOOOTOOO0000000000000000000000000000000000OT000000 120 110 1ooooot00000a00000y0000000000o000z0e00000p00t00000000 90 so 7
60 so 4
30 2020 MANWAY NOZZLE
1
Framatome ANP Inc.
Customer Name: Millstone Unit 3 10/10/02 15:49:00 Component: S/G A Page I of I 1-19% TW Indications for SVI Sizing QUERY: 1-19%TW for SVI ROW COL. VOLTS DEG 5
121 0.09 249 0.05 0
5 122 0.17 0
0.34 0
0.23 255 6
122 0.04 65 0.06 0
7 3
0.18 0
8 3
0.06 95 0.05 0
10 116 0.07 0
24 11 0.22 67 0.18 0
29 109 0.12 85 0.09 0
29 110 0.06 71 0.04 0
0.13 78 0.11 0
43 103 0.09 102 0.07 0
C8N 4
P12 P12 P12 P12
.4 P12 P12 4
P12 P12 4
P12 4
P12 4
P12 4
P12 4
P12 IND
- TND, TWD TND TWD TWD TWD TWD TWD TWD
- TWD, TWD TWD TWD TWD TWD TWD TWD TWD TWD TND TWD
%TW LOCATION 11 TSH
+1.13 2
TSH
.1.13 7
TSH
+0.51 14 TSN
+0.97 9
TSH
.1.71 9
TSH
+4.12 2
TSH
+4.12 6
+0.09 12 TSC
.0.50 1
+0.50 3
TSH
+0.61 19 TSH
+0.10 7
TSH
+0.10 is TSC
+0.08 3
+0.08 15 TSC
+0.03 1
+0.03 18 TSC
+0.09 4
+0.09 16 TSC
.0.73 2
+0.73 EXT EXT TSH TSH TSH TSH TSH TSH TSH TSH TSH TSH TSH TSH TSH TSH TSC TSC TSC TSC TSC TSC TSH TSH TSH TSH TSH TSH TSC TSC TSC TSC TSC TSC TSC TSC TSC TSC TSC TSC TSC TSC TSC TSC UTIL 1 UTIL 2 CAL #
=.52.
52 52 52 52 52 52 S2 66 66 66 S2 52 52 81 81 81 81 81 81 81 81 LEG HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD PROBE 560PP 56OPP 560PP 560PP 560PP S60PP S60PP 560PP 560PP 560PP 560PP 560PP 560PP 560PP 560PP 560PP 560PP 560PP 56OPP 560PP 56OPP Total Tubes
- 10 Total Records: 21
pI, GROUP TUB^ES Millstone Unit 3 W 20-39%TW for SVI 4
20-39%TW for SVI 3RO8 - 09/02 FRA.ANP. FDMS mmn maDje Venom 2.1 S/GA TOTAL TUBES: 5626 SCALE: 0.080231 X O T SELECTED TUBES: 4 Thu Oct 10 15:50:01 2002 PRIMARY FACE OUT OF SERVICE (#):
NA bar IwnMe k*ofmln@ lo otu. u'tr WIOhIP.
- ften4I b
-w intsts of FramsW ANP aid wlt b weed upon r"uest.
00000000000000 000000000000000000000000000000 000000000000000000000000000000000000 000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000 QoooooooooQOoooooooo00000o000000000o000000o0OOOOOQoOOg00g 0 0000000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000000000000000000000000000 SOoooooooooooooooolooooooooooooooooooooo000oooooooooooooooooooooooooooe-00 ooooooooooooo000ooooooooooooooooooooo00000000000000000000000000000000000 oooooooooooooooooooooo000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000000000 0 000000000000000000000000000000000000000000000 000000008000000000000000 oooooooooooooooooooooooooooooooooooooooooooooooo000000000000000000000 0.oo oooooooooooooooooooooooooooooooooooooooooooo 0000 oooeo0 0ooooooooooooooo 40 00000000000000000000000000000000000000000000000000000000000000000000000 00000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000:00000000000000000000000000000000000000 0*000000000000000000000000000000000000000 0000000000000000000000000 00000000000000000000 00000000000000000 0
00000000000000000000000ooooooooooooooooo0ooooo 00000000000000000o000000000000000000000000000000000000000
~~~~~00000000000 000000000 0000000000000000000000000000000000 0000000000000000000000000000000000000 000000000000000000000ooooooooooo oooooooooooooooooooooo.0 ooooooooo000000000ooooooooooooooooooooooooooooo 0
0~~000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000888888g8 0000000000000000000000:00000000000000000000000000000000000000000000 00000000000000000000000000000000 0000000000000000000000 0000000000000000000000000000000000000000000 ooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0888g8 888888888888g888888*8gg8888888g88888g8888g888 888g8g888888888°8888888888888888888g~888888888go8888838888888888888 0000000000000000000000000000000 0000000000000000000000000000000000000000000000000 0000000000000000000000000000 0
ooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo 00000000000000000000000000000000o0 W000000000 00000000000000000000000000000000000o0000000000000000 ooooooo00ooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo WOOOOOOOOO0000000000800000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 000000000000088888888 8888000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 ooooooooooooooooooooooooooooo0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000o 12ooooo0 10oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo00oo080o0ooo5040o0o2oo ooooooooooooooooooooooooAoooooWAYoooooNoooooooooooooooooooooooooooooooooooooooooooooooooooooooooo oooooooooooooOoooo ooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo ooooooooooooooooooooooooooooo0 ooooooooooooooooooopooooooooooooooooooooooooooooooooooooooo0oooooooooooooooooooooooooooo 0000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000ooo0000000000ooo00000000 ooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo WOOOOOOOOO00O000000000000000000 000000000000000000000000000000000000000oo0000 000000000oooo0000o000ooo000000000oo00000000oo wooooooooooo o000000000o000000000 000000000o000000000o0000000000000000000o00000o000o0o0000000o000000000o000000000o000000000 wooooooooooo ooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo ooooooo ooooooooooooooooooooooooooooooooooooooooooooo0000ooooooooOO0oooooooooooooooooooooooooooooooooooooooooooooooooooo00 00o000000000oo000000ooo000000000oO00000000o000000000o000oooooooooooooooooooooo0000o000000000o0000000ooooooooooooooooooooooo 120 1t0 100 90 80 70 60 so 40 30 20 10 MANWAY NOZZLE
Framatome ANP Inc.
Customer Name: Millstone Unit 3 10/10/02 15:50:04 Component: SIG A Page 1 of I 20-39% TW Indications for SVI Sizing QUERY: 20-39%TW for SVI ROW COL VOLTS DEG 4
122 0.65 5
122 0.25 0.47 0.29 7
3 0.21 10 116 1.13 0.11 0
267 71 259 89 0
228 CHN IND %TW LOCATION
- =-
5==
5=............
=
...=-=
P12 TWD 24 TSN
- 0.65 4
TWD 20 TSH
+0.51 4
TWD 31 TSB
+0.97 4
TWD 23 TSH
+1.71 4
TWD 21 TSC
+0.09 P12 TWD 38 TSR
+0.26 4
TWD 20 TSU
+0.61 EXT EXT UTIL 1 UTIL 2
=..
==S
=
=T TSH TSH TSH TSH TSH TSH TSH TSH TSC TSC TSH TSH TSH TSH CAL #
52 52 52 52 66 52 52 LEG HOT HOT HOT HOT COLD HOT HOT PROBE 56=PP 560PP 560PP 56OPP 560PP 560PP 56OPP Total Tubes
- 4 Total Records: 7
GROUP TUBES Millstone Unit 3 W40-100%TWforSv 2
40-1 00%TW for SVI 3R08 - 09/02 F"A.ANP. FOMS mvp modyle Vesmon 2.1 SIG A TOTAL TUBES: 5626 SCALE: 0.080231 X HOT SELECTED TUBES:
2 Thu Oct 10 15:51:01 2002 PRIMARY FACE OUT OF SERVICE (#): NA 0OW nMM ptob00MdaWmedAN0Rpd. Im-f0In.toofused fo, kuroWhV Wo~toi n bo o~. Or for any oftw. pum.oss debWo*.t to thr hknts of Framnalome ANP d wil h. 'Wumod uponl rmqUgst.
00000000000000 000000000000000000000000000000 000000000000000000000000000000000000 000000000000000000000000000000000000000000 0000 00000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000000000000000000000000000 50 *0 ooeeooooooooGe**50 000000000000000000000000000000000000000000000000000000000000000000oooo 00000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000000000000oo 0000000000000000000000000000000000000000000oooooooooooooooooooooo00000000000000000 000000000000000000000000000000000000000000000000000000000000000000000000000000oooooQ 00000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000oo0000000000 40 0o&
40 00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000300 00000300 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 30-30 o00000oo000000000oo000000000o00000000000000ooo ooo ooooooooo oooooooooooooooooooooooooooooooooooooooooooooooooo ooooooooooooooooooooooooooooooooooooooooo 00ooooooooooooooooooooe ooooooooooooooooooooooooooooooooooooooooo o ooooooooo0ooooooooooooooooooooooooooooooooooo000000oooo0oooooooooo oooo0ooooooooooooooooooooooooooo0ooooooooo0o ooo0oooooooooooooooooooooooooooooooooooo ooooo oooo0ooooooooo ooooooooo oooo ooooooooo0oooo oooooooooooooo oo ooooo0o oooo0 20 110 100 0
80 70 60 50 40 0
20 10 20 000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000ooooooooooooooooooooooooooooooo0oooo0oooo0ooooooooo0ooooooooo0ooooooooooooooooo0ooooo ooo0oooo0o oooo00 ooooooooo0oooooooooooooooooooooooooooooooooooooooo0oooooooooooooo00000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000o0000000o oooooooooooooooooooooooooooooooooooooooooo00000000000000000000000000000000000o0000000000000000000 oooooooooooooooooo00000 o0000000000000000000000000000000000000000000000000000000000000000000000C>000000000OO0ooooo0oooo00000000000000000o0ooooooooo 00000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000 00000000000000 000 0000000000 00000000000000000000000000000 00000000000000000 00000000000000000000000000000000000000000 000000000000000 00000000000000 100oowooooooooooo I-oooooooooo 0oooooooooo woooooooooooooooooooo000000000000000000000000000000000000o000000000 00 000000000o000 000000000000000000 00000000000 0000000 00000 oo o0ooooooooooooooooooooooooooooooooooooooooo ooooooooooooooo0000ooo0000000000000000000ooooooooooooo0ooooooooooo0oo0oooo000000 120 110 100 90 80 70 60 50 40 30 20 10 MANWAY NOZZLE
I Framatome ANP Inc.
Customer Name: Millstone Unit 3 10/10/02 15:51:04 Component: S/G A Pace I of I 40-100% TW Indications for SVI Sizing QUERY: 40-100%TW for SVI ROW COL VOLTS 4
122 0.90 10 116 1.61 DEG CHN 250 4 52 4 IND %TW LOCATION TWD 47 TSH
+0.65 TWD 64 TSH
+0.26 EXT EXT UTIL I UTIL 2 CAL #
art====r===-======
==
TSH TSH 52 TSH TSH S2 LEG HOT HOT PROBE S6OPP==
560PP 560PP Total Tubes
- 2 Total Records: 2
Docket No. 50-423 B18942 Millstone Power Station, Unit No. 3 UC" Steam Generator AVB Indications
GROUP TUBIES M illstone Unit 3 lW1-19%TW Indications 14 1-19%TW Indications 3RO8 - 09/02 FRAANP. PF" mm V
S/G C TOTAL TUBES: 5626 SCALE: 0.080231 X HOT SELECTED TUBES:
14 Fri Oct 11 11:44:53 2002 PRIMARY FACE OUT OF SERVICE (#):
NA Ym Wi1n.o
- A Pntr^p.
rn pw b b rfu ni o*
Wcfmaw" to
~. at for sny WrpmOM de*"W lao VW :eWut ot Frimom. ANP nd wN be rfumcO won raqes 00000000 00000000 000000000000000000000000000000 000000000000000000000000000000000000
.0000000000000OOOOOOOOOOOOOOOOOOWOOW 0000o§00000000000 0000000000000000000000000000000 000000000 0000000000000000000000000000000000000000000W0 o000000008000000000800000000000000000000000000000000000000 OQ OOO~gOOOOO000000000000000000000000000000000000000000
'0000000000 000000000000000000000000000000000000000000000000 50 50 00000000000000000000000000000000000000000000000000000000000000000 000 000000000000000000 0000000000000000000000000000000000000000000000000 000000 WQOQOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOO 5000000000000000%0o0000000000000000000 OOOOO0000000000000000000000000000000000 080000000000800000800000000000000o000008000000000000000000000000000000000000000000 00000000000000000000000000000OOOOOOOO 00000000000000000000000 00000000000000000000 0000000000000000000000000000000000000000000000000000000000000 0000000008000000000 00000000000000000000000000000000000000000000000000000000000000000000000000000000000%0 400-00o0oe0oo oooo00 oov ooooooooooooooooeooooo ooooooooooooooooooo0oe000oo oooo0oooo000e00000
- 40 OOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOQOOOOOOOOOOO0000wooooooooooooooo000000000000000oooooooooooowo 000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 ooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo ooooo0000000000000000000 000000 00555oo0000000o 0OOOOOOOOOOOOOOOOOOOOO0ooooooooooooooooooooooooOOOOOOOOOO0000000 o000000000 00000000000 30 55 5
5 55 5
55 5 5 58 5 5 55 5 5 55 5 5 85 5 5 855555o 0000000000000000000000000000000000000000 ooooo0000000000000000000000o 00000000000000000000000000000000000 000000000000000000000000000000000000000 ooo oooooooooooooooooooooo oooooooooooooooooooooooooooooooooooooooo0000 ooooooooooooooooooooooooooooooooooooooooooooooooooooooooloooooooooooooooooooooooooooooooooooooooooo0000000O000000 200 0000000000.00000.00g0000000 000000000000000000000000000000000 0
2 ooooo0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000 0000000000000000000000000000000000000000000oo00000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000090000000008000000000000080000000000000000000000000000000 000000000000000000000000000OOOOOO 000000000000000000000000000 000 0000o o00000000o o000oo0ooooo 0000000000000000000000000000ooooooooooooooooooooooooooo 10000000$
$$8888 88888$0000000000000000000000g000 0000000000000000000000000080000000 -0 O000000000000000oo8o0000 10 20 20 ooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooO 00000000000000000000000oooo0oooo0oooooo ooooo0oooooooooooOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOO0000000000000000000000000000000000000 00000000000000000000800000000000000000000000000 500 0000000000000000000000000000000000000000000000000000000000000000000 00000000000000000000000000o0 000000000000000000000oooooooooooooooooooooo0000000000000000000000000000000000000000000000 ooooooooooooooooooooo0000000009000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 ooooooooooooooooooooQOrOOOOOOOOOOOOOOO0000000000000000000000000000000000000000000OO000000000 000000000000000000000000000 00000000000000000000000000000 0
00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000 000000000000500000000000000000000 0000000000000000000000000000000 120 11 100ooooo0oo80oo70ooo60 50oooooooooooooooooooooooooooooo 40 30oooooosooooo e
20 10 MAN ooooooooWAYooooooooNOZZLEooooooooooooooooooooooooooooooooooooooooooooooooooo oooooooooooooooooooooooooooooooooooooo 00o000000000o000000000o000000000o000000000o000000000 000000000o000000000o000000000o000000000o000000000o000000000o000000000 ooooooooooooooooooooooooooooooooc 0000000000000000000o00o00000oo000000000o000oo0000o000000000o000000000o000000000o000000000 00o000000000o000000000o000000000o00000o000o000000000o000000000o00ooooooooooooo0000so00ooooooooooooooooooooooooooooooooooooo 120 110 100 go 80 70 60 5040 30 20 10 MANWAY NOZZLE
Framatome ANP Inc.
Customer Name: Millstone Unit 3 1-19% TW Indications QUERY: 1-19%TW Indications 10/11/02 11:45:00 Component: S/G C Page 1 of I ROW COL VOLTS DEG CHN IND 4TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL I LEG 34 14 0.33 0.32 36 15 0.33 0.49 37 15 0.44 0.45 0.42 39 17 0.43 0.39 0.57 39 79 0.71 41 54 0.39 0.70 0.67 41 62 0.74 0.74 0.84 0.67 41 65 0.58 42 20 0.66 0.63 47 99 0.65 50 28 0.30 54 36 0.47 0.40 0.46 56 41 0.32 0.45 0.57 56 44 0.47 0
0 122 65 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
P 2 TWD 11 AV2
-0.03 P 2 TWD 11 AV5
+0.05 P 2 TWD 11 AV5
+0.11 P 2 TWD 15 AV6
+0.16 P 2 TWD 13 AV4
+0.00 P 2 TWD 14 AV3
.0.00 P 2 TWD 17 AV6
+0.14 P 2 TWD 13 AV6
+0.13 P 2 TWD 12 AV3
-0.05 P 2 TWD 17 AV2
-0.03 P 2 TWD 18 AV3
-0.38 P 2 TWD 10 AV1
-0.03 P 2 TWD 17 AV3
-0.40 P 2 TWD 16 AV4
-0.24 P 2 TWD 17 AV3
+0.32 P 2 TWD 17 AV4
-0.42 P 2 TWD 19 AV4
+0.24 P 2 TWD 16 AV3
-0.37 P 2 TWD 18 AV4
+0.49 P 2 TWD 17 AV2
-0.26 P 2 TWD 16 AV6
-0.16 P 2 TWD 16 AV6
-0.03 P 2 TWD 11 AV4
+0.03 P 2 TWD 12 AV4
-0.05 P 2 TWD 10 AV5
-0.13 P 2 TWD l1 AV3
-0.05 P 2 TWD 10 AV2
+0.11 P 2 TWD 13 AV4
+0.00 P 2 TWD 16 AV6
+0.00 P 2 TWD 12 AV4
-0.05 TEH TEC TEH TEC TEN TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC
-TEH TEC TEH TEC
=========...=..
6 6
4 4
2 2
2 2
2 2
36 25 25 25 25 25 25 25 26 23 23 45 26 25 25 25 32 32 32 31 COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE
.SEOU:=L 560UL 560UL S60UL 560UL 56OUL 560UL 560UL S60UL S60UL 56OUL 560UL 560UL S60UL S60UL S6OUL S60UL S6OUL S6OUL 560UL S60UL 560UL S60UL S60UL S60UL 560UL S60UL 560UL S60UL 56OUL 560UL Total Tubes 14 Total Records: 30
GROUP TUBES Millstone Unit 3 W20-36%TW Indications 14 20-36%TW Indications 3RO8 - 09/02 S/G C TOTAL TUBES: 5626 SCALE: 0.080231 X vO T SELECTED TUBES:
14 Fri Oct 11 11:46:00 2002 PRIMARY FACE OUT OF SERVICE (#): NA
'=-:o-
= d d
PRIMARY FACE W k,,W" vdonr~~~~~~~~~~~~~~~~~~~~~~~~tjon la ~. or for &W ~ purpme deofwvW*l i"n"bflW tHw. r "r4WO 1r u0e etnmW ft kaovst@ olFm km M
00000000000000 000000000000000000000000000000 000000000000000000000000000000000000 ooooooooooooooooooooooooooooooooooooooooooooooooo 5 00000000000000000000000000 000000000000000000000000000000000 00 50 ~ ~ ~ ~
~
~
~
~
~
~
~
~ ~ ~ ~ ~~~~~~
~~~~50 w000000000000000000000000000000000000000000000000000000000000000000000 oo00o0000oo0o0000000oo0oo000000oo000000oo00o0000ooooopoooooooooooooooo0000o 0000000000800000000000000000000000000000000000000 00000000000000000oo00000000o 0000000%000 0000000000000000000000000000000000000000000000000000000000000000000 OOOOOOOOQOOQOOOOOOOOOg0000000000000000000000000000%00g00000 0 0 00 0 0 00 0 0 000000000W00.
00000000000000000OOOOOOOOQOOOOOOOOOOOOOO 0000000000000000000000000 40 ~~~~oooooooooooooooooooooooo oooooooooeoooo ooooo ooooooooooooeeoo~ooo 40 0000000000000000 000000000000000000000000000000800000000000000000000000000000 0OOOOOOOOOOOW 0000 o0000000o0000ooooooooQooooooooooooooooooooooooooooooooooooooo00oo woooogoooooo ow 000000000~00 00 00000000000000000000000000000000000000800000000000000000008000000000000000000oow 000009008000000000 00000000000000000000000000000000000000000000000000000000000000000W 080000000000 0000 00008 0000000000000000000000000000 0000 000000000000000000000000W 0000000000000000 80000~00000000000 000000000000000 00000000000000000000000000000 000000000000000000 ooooooooooooooooooooooooooooooooooooo0oooooooooooooooooooooooooooooooooooooooo0000000000000000000 30.. o oooooooooooooo eo~oooooooooooooooooooooooooooooooooooooooo oooee ooooo e
- 3 ooooooooooooooooooooooooooo0000ooooooooooooowooQMooooWOO0 oooooOOO00ooooOOOOOO000o0oooOOO 00o0oO 8 8~8~8~8 88$88$88888 888888888888888 8888°o88888 °88888888888888888888888888888°888888° 88 0000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000 00000o000000000o00000000000000000000000000000000000000000000000000000000000000o000000000000000000000oo 00
'00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 20 2000000IDCo 0
0 00000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000 000000000000000000000000000008 0..,00 00000000000 oooooooooo0000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000000 000000000000000000000000000o0000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000 0000000000000000000 0000000000000000000000000000000000000000 00000000080000000000000000 0000000 000000008000000000 000000000%0800000000000000000000 80000000000000000000000000000 000000000 000000000000000000 0
0000000000000 0000000000000o0000000000000000 0oooooooooooooooooooooo000000000 0
00000000000000000000000000000000000 0000000000000000000008000000000 000000008000000000000000000008000000000800000000o0 0000OO0000000000000000000000000000000 0000000000000000000000 0000000000000000 0000000000000000000000 000000000 000000000 0000 0000000000008000000000000000000 0
OOOO OOOOOOOOOOOOooooo00 00 0OOOOOOOOOOOOOOOOOO OOOOOOOOOOOOOOOo 00 0000000000000000000000000000 000000000000000000 00000000000 0000000000000000000000000000000000000000000000000000000000000000000008000000000000000000000000000000000000000 080880088800000000000800000000080000000008000O00000000000000000000000000000000000 000000000000000000000000000000000000000 ooooooooooo ooooooooooooooooooooo oooooooooooooooooooooo.
ooooooooo o0oo00o08o00o00000o080 0oo00000000o o00000 0000 0000000000000000000000 0000000000~0000O0000000000000000000000000000000000080000000000000000000000000000080000000000000000000 oo ooooooooooooo000000000 000 o00ooooo0oo0o0oooo00000oooo 000000000o000000000000000000o000000000oooooooooooooooooooo 120
.00 0 110 10 8.7.0504 0
01 ooo Nooooooooo ZooE ooooooo000ooo0000ooooooooosooooooooooo000000000 ooooooooo~ooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo oooooooooooooooooooooooooo90ooooooooooooooooooooooooooooooooooooooooooooooooo I
MANWAY NOZZLE
Framatome ANP Inc.
Customer Name: Millstone Unit 3 10/11/02 11:46:03 Component: SIG C Page 1 of I 20-36% TW Indications QUERY: 20-36%TW Indications ROW COL VOLTS 25 116 0.84 37 15 0.93 1.31 39 17 0.76 0.70 41 42 0.87 41 54 0.96 41 61 1.06 41 62 0.90 1.62 41 65 0.74 42 20 1.02 1.05 1.14 42 23 0.82 1.50 1.19 46 33 0.76 49 96 0.84 1.11 50 28 0.69 56 41 0.96 DEG CHN
==.
0 P 2 0
P 2 P 2 0
P 2 0
P 2 0
P 2 0
P 2 0
P 2 0
P 2 0
P 2 0
P 2 0
P 2 0
P 2 0
P 2 65 P 2 79 P 2 90 P 2 0
P 2 0
P 2 0
P 2 0
P 2 0
P 2 IND TAD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TAD TWD TWD TWD TWD TWD TWD TWD
%TW LOCATION 23 AV6
.0.00 24 AV2
-0.11 33 AV5
+0.14 21 AV5
+0.03 20 AV4
-0.05 20 AV3
-0.03 21 AV5
-0.26 27 AV3
+0.00 20 AV2
.0.03 31 AV5
-0.16 21 AV5
-0.08 23 AV3
-0.13 24 AV4
-0.13 25 AV5
.0.29 23 AV3
-0.08 32 AV4
-0.11 29 AV5
-0.05 22 AV6
+0.45 20 AV5
+0.00 24 AV6
-0.05 20 AV5
+0.05 23 AV5
+0.14 EXT TEH TEH TEH TEN TEH TEN TEH TEH TEN TEH TEH TEH TEE TEE TEE TEH TEE TEH TEH TEH TEH TEH EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC UTIL I UTIL 2 a...====
=
=.
CAL #
66 2
2 2
2 25 25 26 25 25 26 23 23 23 24 24 24 26 45 45 26 32 LEG COLD====
COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 56OUL 56OUL 560UL 56OUL 56OUL 560UL 560UL 560UL 560UL 560VL 560UL 560UL 560UL 560UL 560UL 560UL 560UL 560131 560UW 560UW 560131 560UL 560UL Total Tubes
- 14 Total Records: 22
GROUP TUBES M illstone Unit 3 W37-100%TW Indications 1
37-1 00%TW Indications 3RO8 - 09/02 Rk"NON.FomS mID modu&e Venibn 2.1 S/G C TOTAL TUBES:
5626 SCALE: 0.080231 X HOT SELECTED TUBES:
1 Fri Oct 1111:47:032002 PRIMARY FACE OUT OF SERVICE (#)N NA _
VW b
is W.
i PRIMARY FACE
~~~~~~
~
~
~~~~~~~~~~~~
=ufMgb~~aln fooDo o Pycvw pufpat 4e.fr.W 0 oo00°000,0,0,0g0088088 00888800000000 000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000 00000000000OOOOOOOOO00000000000000000000000000 00000000 0000000000000000000000000000000000000000000000000000000000000 000 000000000000000000000000000000000000000000000080000000 0000000 00000o0000000000000000000000000000000000000000000 00 00000000000000000000000 00000000000 0O00OOO0 0000000000000000000 0000000000 o o000000000000o oooooooooooooooooo000000000o0000000000oooo 000000000o 00000000000000000 000oo0000000000000000000 00000000000000000000000000000000000000000000000000000oO 0000000000000000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000000000000000000 40-~ooeooooop~<ooooeoooooooooeoooooooooepooooooooDooooeoioooooooooooooooo00000000000000000 0
ooe-4 0 0000000000000000000000000000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000000000000000000000000000000000000000000000000 40000 000000000000000000000000000000000000000000000000000000040 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00000800000 000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000 000000000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 30 000 oO OooO O
O 00000000000000000000000 00000 0000000000000000000000000000000000000000-0000000000000000000000000000000000000000 0000000000000000000000: 0000000000000000000000000000000000000000 oooooooooooooooooooooooooooooooo~ooooo0ooo00000000000000000000000000000000000000000000000000000000000000000 30 OoOoOooooOOo 30oOOOOOOOOOO~oooOOO 0000000000000000000008000000008000:000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 oooooo0oooooooooooooo0o0000000000000000000o00 00000000000000000000000000000oo0000000o00000000000000000000000000o 0
10 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000001ooooooooooooooooooooo1 000000000000000000000000000000000000000 00000000000000000008000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 20-oooooeooooooooooooooooooooooooooooooooo(0000000000000000000000000000000000000000000000000000000000000000000 00000 oooooooooooooooooo0oo000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 000000008000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000000000888880000000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00000000000000000000009000000000000000000000000000000000000000000000000000000000oo0000000000000000000000000000000000000 oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo 120 110
¶00 90 8~~~~)
0 7011 605 4
0 01 00000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000 WAY NoZZLE ooooooooooo0ooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo ooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo ooooooooo00ooooooooooooooooooooooooooooooooooooooooooooooooooooo0ooooooooooooooooooooooooooooooooooooooooooo0ooooooooooooo 120 110 100 90 80 70 60 50 40 30 20 10 MANWAY NOZZLE
a Framatome ANP Inc.
Customer Name: Millstone Unit 3 10/11/02 11:47:06 Component: S/G C Page 1 of 1 37-100% TN Indications QUERY: 37-200%TW Indications ROW COL VOLTS 41 61 3.07 3.28 DEG 0
0 CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL #
=
-~
=.. =-
=====-
.=== =-=
.=
P 2 TWD 44 AV4
-0.05 TEH TEC LAR 26 P 2 TWD 45 AVS
-0.03 TEH TEC LAR 26 LEG COLD COLD PROBE 56OUL 56OUL Total Tubes
- 1 Total Records: 2
-il
O 4-Docket No. 50-423 B1 8942 Millstone Power Station, Unit No. 3
'C" Steam Generator Volumetric Indications
4 GROUP TUNES Millstone Unit 3 V
VOL Indications 7
VOL Indications 3R08 - 09/02 MA.ANP. POW4 Mu m"edj Vmo 21' SIGC TOTAL TUBES: 5626 SCALE: 0,080231 X HOT SELECTED TUBES:
7 Fri Oct 1112:05:502002 PRIMARY FACE OUT OF SERVICE(#):
NA
_ go for oWr*.
f"orwo inor poo derfoterWa f
WA.
kdW"%f of Frammtme ANP and..d be rewmed ugon request 00000000000000 00v000000000000000000000000000 000000000000000000000000000000000000 000000000000000000000000000000000000000000 0 000000000000000000000000000000000000000000000000 0000000000000000000000000000 0000000 000000000000000000 0000000000000000000000000000000000000000000000000000000000 000000O00000000 00000000000000000000000000000000000000000 0
50 -
0000OOOOOOOOOOOOOOOOOOeOOeOOOO0 eOC)
OOOOOOOOOeOOOOOOOOOOeOOOOOOeOOOO50 0000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000ooooooooooo000000000000000 ~00000000O000000o 00000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000 000000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000V 00000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000000000oo0 00000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 40000000000000000000000000000000000000000000000000000000000000040000000000000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000 o000000000000000000000ooooooooo 0000000000 0000000000000000000000000000000 00000000000000000000 0000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000 80000000800000000000000 0000000800000000000000 0000000000000000000000000000000000 00000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0
00000000000000000000000000000 00000000000000000000000000000000000 00000000000000000000000000000000000000000000 00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0000 00o000000o000gEo0000000000000000000000000 0
0000000000000000000 00000000 000000 0000000000-.020 000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000 000000000000000ooooooooooooooooooo00OQOOOooo 00000000000OOOOOOOOOOC)OOOOOO0000000000000000000000000000000000 000000000000000000000000000000000000000000000000000o 00000 0000000000000000000000000000 o0000000000000000oooooQooooooooooooo O000000000000000000000 0000000000000000000000000000 1 -0000000000 00000010000000---
000 00000000000000000000000000000000000000000000000000000000- 0000000000 000000 00000009-1 g
00000000 000 0000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000 00000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 OOOOO0OOOOQOOOOOOOOOQO0000008000 000000000PO0000000000000000000000000000000000000000000000 0000000000000000000 0000000 000 000000000000 0000000000000 000 0000000 0000000000000000000000000 00000000000000 000000000000000000 000000000 00000 000000 00 10000000000000000000000000000000o00000v000000or0900000--0i0000000v000000000r8ooooroorr000o000000000v0000000- oooorso300r00 0000000000000000000000000000000000000000000000 00000000000000000000000000000000000000000 00000orooo0000000000000000000000 i20 1110 08 0605 03 01 M
0 000000 WAYL0000000000000E0000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000 E
000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00000000000000000000000080000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000008000000000 00o0000000003000000000000000o000o000000000oooooooooooooooooooooooo000000o000o00000o0000000o0o000000000oo00000000oooooooooo 000000000000 000000000 00000000000000000000000000000000000000000000000000000000000800000000000000000o0oo000000000o000000000 00000000000000000000000000000000000000000000000000000000000000000000000000 000000000 000000000900000000000000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000000080000000000000000000 00000000000000000000000000000 00000000000OO000000000000000TOO00000000o O
0000o00000000oOO00oOoToo0000000oo 000000000oo 0000000000000000000oo000000000 i20 110 100 so 80 70 60 so 40 30 20 10 MANWAY NOZZLE
Framatome ANP Inc.
Customer Name: Millstone Unit 3 10/11/02 12:05:54 Component: S/G C Page I of 2 Component:nd/icCaPageionofsI VOL Indications QUERY: VOL Indications ROW COL VOLTS 1
54 1.83 8
113 0.31 0.83 12 111 0.70 26 70 0.85 36 20 0.64 42 31 1.91 58 74 0.57 DEG CNN IND tTW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG 132 67 72 111 105 64 130 122
==
3 3
3 3
3 3
3 VOL VOL VOL VOL VOL VOL VOL VOL
=z
===.
07H
+39.15 TSH
+0.63 TSH
+3.13 02H
+7.75 04H
+25.76 TSN
+3.66 07H
+218.21 04H
+13.63 07H TSH TSH 02H 04H TSH 07H 04H 08H TSH TSH 03N 05H TSH 08H 058 50 HOT 31 HOT 31 HOT 52 HOT 45 HOT 7
HOT 49 HOT 58 HOT PROBE 560PP 560PP 560PP 560PP S60PP 560PP 560PP 560PP Total Tubes
- 7 Total Records: 8
Is
-~T'.
I Docket No. 50-423 B18942 Millstone Power Station, Unit No. 3 "C" Steam Generator Single Volumetric Indications
GROUP TUBES Millstone Unit 3 W1-19%TWforSVI 7
1-1 9%TW for SVI 3RO8 - 09/02 FRA.ANP
. FOMS map moduLf Vemso 2.1 S/G C TOTAL TUBES: 5626 SCALE: 0.080231 X HOT SELECTED TUBES: 7 Fri Oct 11 11:50:21 2002 PRIMARY FACE OUT OF SERVICE (#): NA
, =:o "
3 A i S:i tot NfwYthkV Inhomat~n to OV*eq. or for any other putol$ dftrnngntal tO ooo oeoots Of POm ANP ando W01
'tw ttUOo leouest 00000000000000 000000000000000000000000000000 000000000000000000000000000000000000 WO00oooooooooooooooooo00000000000000000000 0
0 0ooooooooooooo0oooo0000000000000000000000000 0000000000000o00000000ooooooooo0000000000000000000000 0000000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000000000000000000000000000 50 - O~oo~ooeoo&
~
~~50 0000000000000000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000000000000000000000000000000o000000000o 000000000000000000000000000000000000000000000000000000000000000000000000000000oo 0000000000000000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 40 -ooe oo ooooooo ooosooEoooooooeoooeoooooeeoooe oooooo o
40 00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 300000000000000000000000030000000000000000000000000000000000000000000000000000000000000000000000000000000000 30 0000000000000000000000000000000000000000 0000000000000000000000:
00000oo00oo00o00000o000000000o0000000o0o0 00000000000000000000000000000000000000000 0000000000000000000000.
00000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo 000000000000000000o000000000o000000000o000o00000o0o0oo0000000000000o000000000o0000000000000000000o0ooooooooooooo 10 10 12011 100oooooooooooooooooooooooo o
ooo9oo oooooooooo oooooo 00 807o6o03 200 1000 0000000000000000 000000000000000000000000000000000000000000000000000000000000 ooooooooooooooo oooooowooooooooooooooooooooooooooooooooooo00ooooooooooooooooooooooooooooooooooooooooooooooooo0ooooooooooo0oooooooooo 00000000o0o000000000o0000000000000000000000000000000000o0000o000000000o000000000o0000000000000o00000o000000000o0000000 00000000000o00000000000000000 o000000000o000000000o0o0000000o000000000o000000000o0o00000 o000000000o000000000o00000000 00000000000000000000000000000000000000000000000000000000000000000000000000000000oo0oooooo00000000000000 00000000000000oo0o 00000000000O000000000o000000000o000000000o000000000o000000000o00000000oo0000o0000o0o0000000o000000000o0000000o0o000000o oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo ooooooooooooooooooooo0oo000000000QoooooooooO0000000000000000ooo000oo00o000000000000000o0o0o00000o000o0o00o0oo0oo0o000o00 oo00000000000000000000000000000000000000000000000000000000000000000000000000000o0000o0000000o0o00000o00o00o000000o000o0000 00o00000000000000000000000000000000000000000000000000000000000000oOOOOOOTOOOOO00000000000000ooo0oo0oooooooooooooooooooooA/0 120 110 100 90 80 70 ooooooooooooooooooooooo60 oooooo5oooo40 ooooo30 oooo20 o
oooooo MANWAY NOZZLE
Framatome ANP Inc.
Customer Name: Millstone Unit 3 10/11/02 11:50:24 Component: S/G C Page 1 of 1 1-1iTW Indications for SVI Sizing QUERY: 1-19%TW for SVI ROW COL VOLTS DEG CUN IND %TW LOCATION EXT EXT UTIL I UTIL 2 CAL # LEG
-~==s.
1 4
0.13 0.12 1
5 0.18 0.16 17 113 0.09 54 64 0.12 54 65 0.28 55 68 0.14 0.08 56 82 0.06 0.05 0.08 0.06 83 0
87 0
0 0
0 69 0
75 0
59 4
P12 4
P12 P12 P12 P12 4
P12 4
P12 4
==2
=
TWD 16 TWD 4 TWD 19 TWD 5 TWD 5 TWD 6 TWD 16 TWD 15 TWD 5 TWD 12 TWD I TWD 13
=S=2====5562==s
=
=
S=
55f TSC
.3.12 TSC TSC TSN
-0.03 TSH TSU TSN
+0.16 TSN TSH TSH
+0.05 TSH TSH TSU
+0.69 TSH TSH TSH
+0.69 TSN TSH TSC
+0.56 TSC TSC 79==
79 79 79 79 44 47 44 44 44 79 79 79 COLD COLD COLD COLD ROT HOT HOT HOT HOT COLD COLD COLD PROBE 560PP 560PP 56OPP 560PP 560PP 560PP 560PP 560PP 560PP 560PP 560PP 0
P12 TWD 2 TSC 40.56 TSC TSC 79 COLD 560PP Total Tubes : 7 Total Records: 13
-~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
GROUP TUBWS Millstone Unit 3 W20-39%TW for SVI 3
20-39%TW for SVI 3RO8 - 09/02 RA.AN. P~DMS Map moodpleVemilo 2./
S/G C TOTAL TUBES: 5626 SCALE: 0.080231 X HOT SELECTED TUBES: 3 Fri Oct 11 12:03:14 2002 PRIMARY FACE OUT OF SERVICE(#):
NA c
tr "
o
?kW reu4 a of FrrAMammoANP andw~i b. roflwnd uaoreq eff 00000000000000 000000000000000000000000000000 000000000000000000000000000008000000 o o 800800000000000000000000000000000 00000000000 00000000000 000000000000 00000000000000000000000000000 oooooo0000000800000000000OOOOOOOOOOOOOOOOOOOOOO0OO0000O00000 0
88 8gg888gg888g888 g g
ggggggg888g$888 g88888888g~ggg888 000000000oo0000000000000000000000000000000000000000000000000o o
50 o000000000005000000000000000000000000000000000000000 0
0000000000000000000000000000000000000000000000000000000000000000000000 000000000000000008000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000 00000000000000000000 00000000000000000000000000000000000000000000000000000000 0000000000000000000 0000000000000000000000000000000000000000000000000000000000o 0000000000000000000000000000000000000000000000o 0000000000000000000000000 00000000000000000000000000000000000000000000000000000000000 00000 00000000000000000000000000000000000000000000000000000000000000000000000000000000 0000 00000000000000000000000000000000000000000000000000000000000000000000000000000 0
000000000000000000000000000000000000o00 00000000 000000000000000000000000000000000000000000004 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0
000000000000000000000000000000000000000000000000000000000000000OOQOOO000000000000000000000 00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000 0000000000 000000000 00000000000000000000000000000000000000000000000000000000000 000000000000000000 000000000000000000000010000~00000000030000000 8888888888 8888088000000000000000000~00080888888888888888800 0000000Q000O 00000 0000 0000000000000000000000000000 000000000 000000000000 30--oooooooooo oooooooooooooooooooooooooooomooooooooooooo-30 oooooooooooooooooooooooooooooooo09oooooo oooooooooooooooooooooo: oooooooooooooooooooooooooooooooooooooooo 00000ooo000000000oooooooooooooooo 000000000000 00000000000000000: ooooooooooooooooooooooo0o0ooooooooooooooO 000000 0000000000000000000000000000000000000000000000000000000000o000000000000000000000000000000000000000000 00000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000 00oooO o000000000000000000000000000000000000000000000000000000000000000 OOOOOOOOOOOOOOOOOOOOOOOOO00000 0 0 0 0 0 0000 00000000000000000000000000000 0000000 000000000000000000000000000000000080000000 00000000000000000000000000000000000 20
.00oooooooooo0 000 00000000000oooooooooooo 000000 00000 0ooooooo o0 000000000000000000 000000000000000000000000000000000000000000000000000000000000o00000000000000000000 000000000000000 00000000000000000000OOOOOOOOOOOOOOOOOQsOOOO0000000000000000000ooooooooboooooooogooooooooooooooooooooo00000000000000 0000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 ooooooooooooooooooooooooooooOOoooooooooo00000000000000000000000000000000000000000000000000000000oo000000000000000000 0000000o 00000000000 ooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo808808000000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00000000000 000000000000000000000000000003000000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000 OOOOOQOOOOOOOOOOOOOOOOOOOOOOQOOOO 000000000000000000000000000000000000000000OQ0000000 000000000000000000000000 800000000000000000p000000000000000000000000000000000000000000000000 0000000000000000000000000000 120
¶1000 0
10000000000 900700 40..30..
20 1
0M000000000L0000000000000000000000000000000000000000000000000000000000000000000000000000E00000000000000000000000000000 808°oo°8000 ° 8°b ° °8 °°00000°8 00008o8
°0°8o0$00000 0000000o8°
° oo°°°8 0°
° 0o 8oo°80°o 00°0 o8°°000000
°000000000o000o 0880000000008080000000 0000000008000000000 00000000080000000008000000000 000000000800000000080000000008000000000800008000 ooooooo oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo00000 00oo000000000o000000000o000000000o000000000oo00000000o0o00000000000000000o00000ooooo00ooooooooooooooooooooooooooooooooooooo 00oo0000000o 000000000oo000000000ooO00000OO0000000oO000000000OTOO0 o00OoOOOTOwOOOOOOOOTooooooooooo000000000000000o0 120 110 100 90 so 70 60 so 40 30 20 10 MANWAY NOZZLE
Framatome ANP Inc.
Customer Name: Millstone Unit 3 10/11/02 12:03:17 Component: SIC C Page 1 of 2 20-39%TW Indications for SVI Sizing QUERY: 20-39%TW for SVI ROW COL VOLTS 17 113 0.31 54 64 0.18 54 65 0.43 DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL #
=
-=
-=
-S
=
=
s
= ~
=s -
=
23 4
TWD 30 TSH
-0.09 TSH TSH 44 91 4
TWD 25 TSH
+0.16 TSH TSH 47 275 4 TWD 33 TSH 40.0S TSH TSH 44 LEG HOT HOT HOT PROBE
.... O-56OPP 560PP S60PP Total Tubes
- 3 Total Records: 3