05000456/FIN-2009002-01
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Safety Injection Pipe Support Deficiencies |
| Description | A finding of very low safety significance and an associated NCV of 10 CFR Part 50, Appendix B, Criterion III, Design Control, was identified by the inspectors for the licensee\'s failure to properly evaluate the addition of lead shielding to Unit 2 safety injection piping. Specifically, the licensee did not have sufficient rationale and incorrectly concluded that sufficient margin existed in the pipe support design with the additional weight. The licensee entered the issue into their corrective action program, revised associated calculations, and planned modifications as needed to restore required design margins. The finding was determined to be more than minor because compliance with Seismic Category I design requirements was necessary to ensure the Subsystem 2SI06 pipe supports would function as required during a Seismic Category I design basis event. The finding screened as having very low safety significance because the design deficiency was confirmed not to result in loss of operability of the safety injection pipe supports. The cause of the finding is related to the cross-cutting component of Human Performance, Resources, because the licensee did not maintain adequate design margins (H.2(a)) |
| Site: | Braidwood |
|---|---|
| Report | IR 05000456/2009002 Section 1R17 |
| Date counted | Mar 31, 2009 (2009Q1) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.17 |
| Inspectors (proximate) | B Dickson A Garmoe |
| CCA | H.6, Design Margins |
| INPO aspect | WP.2 |
| ' | |
Finding - Braidwood - IR 05000456/2009002 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Braidwood) @ 2009Q1
Self-Identified List (Braidwood)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||