05000443/FIN-2014005-02
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Failure to Identify and Evaluate FSB Deviation from Design Basis |
| Description | The inspectors identified a violation of 10 CFR 50 Appendix B Criterion XVI, Corrective Actions, of very low safety significance because NextEra did not promptly identify a condition adverse to quality in December 2013 that involved a deviation from expected settling assumptions in the Seabrook Station design basis for the FSB. FSB elevation measurements were received by NextEra staff in December 2010 and in December 2013 indicating that settling at some locations of the FSB was occurring. NextEra staff did not enter this condition, a condition adverse to quality, into their CAP until December 8, 2014, in response to questions from the inspectors. NextEra initiated AR02011698 to enter this issue in the CAP and AR02014116 to address their staff not entering this issue previously into the CAP. This performance deficiency was considered to be more than minor because it is associated with the Barrier Integrity Cornerstone objective to provide reasonable assurance that physical design barriers protect the public from radionuclide releases caused by accidents or events, and adversely affected the attribute of design control structural integrity. Specifically, the inspectors concluded that the structural integrity of the FSB was potentially adversely affected because measured settling of the structure deviated from assumed design basis values. Also, this condition exceeded the ACI 349.3R-96 Tier II structural criteria of the Structures Monitoring Program and requires a structural evaluation. This issue was evaluated in accordance with IMC 0609, Appendix A, The Significance Determination Process for Findings At-Power, Exhibit 3, Barrier Integrity Screening Questions, and screened as very low safety significance (Green) because the observed degradation does not adversely impact structural or radiological barrier functions for the FSB. This finding is related to the cross-cutting area of Human Performance - Design Margins. The organization did not maintain the FSB within design margins and did not utilize the systematic and rigorous corrective action process. |
| Site: | Seabrook |
|---|---|
| Report | IR 05000443/2014005 Section 1R12 |
| Date counted | Dec 31, 2014 (2014Q4) |
| Type: | NCV: Green |
| cornerstone | Barrier Integrity |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.12 |
| Inspectors (proximate) | C Newport D Silk G Dentel P Cataldo R Barkley T O'Hara W Cook B Dionne |
| Violation of: | 10 CFR 50 Appendix B Criterion XVI |
| CCA | H.6, Design Margins |
| INPO aspect | WP.2 |
| ' | |
Finding - Seabrook - IR 05000443/2014005 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Seabrook) @ 2014Q4
Self-Identified List (Seabrook)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||