05000390/FIN-2009004-01
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Failure to Incorporate Existing Design Criteria Into Temporary Secondary Containment Boundary Doors |
Description | A self-revealing, non-cited violation (NCV) of 10 CFR 50 Appendix B, Criterion III, Design Control, was identified for failure to correctly translate the personal access door design basis into the specifications for the temporary ABSCE boundary doors installed to facilitate Unit 2 construction. As a result, the ABSCE boundary was disabled when the temporary doors (R002 and R003) failed during auxiliary building ventilation changes on May 27, 2009. The licensee entered the issue into the corrective action program as PER 172301, made door repairs to reestablish the ABSCE boundary, and took interim actions to minimize differential pressure across the temporary doors during auxiliary building ventilation changes. The licensees failure to utilize existing design criteria for doors R002 and R003 was a performance deficiency. The inspectors reviewed Inspection Manual Chapter (IMC) 0612 and determined that the finding was more than minor because, if left uncorrected, it would have the potential to lead to a more significant safety concern, specifically for loss of the secondary containment boundary. Additionally, the finding was associated with the design control attribute of the Barrier Integrity cornerstone and adversely affected the cornerstone objective of providing reasonable assurance that physical design barriers, such as the secondary containment boundary, protect the public from radionuclide releases caused by accidents or events. Using the phase I screening worksheet of IMC 0609, the inspectors determined that the finding was of very low safety significance (Green) because it only represented a degradation of the radiological barrier function provided for the auxiliary building. The cause of the finding had a cross-cutting aspect in the area of human performance associated with the resources component. It was directly related to maintaining long term plant safety by maintenance of the design margins aspect of the resources component H.2(a). Specifically, the licensee did not utilize the existing design criteria for auxiliary building doors designated as air locks |
Site: | Watts Bar ![]() |
---|---|
Report | IR 05000390/2009004 Section 4OA3 |
Date counted | Sep 30, 2009 (2009Q3) |
Type: | NCV: Green |
cornerstone | Barrier Integrity |
Identified by: | Self-revealing |
Inspection Procedure: | IP 71153 |
Inspectors (proximate) | R Monk R Hamilton W Loo H Gepford E Guthrie M Pribish M Coursey |
CCA | H.6, Design Margins |
INPO aspect | WP.2 |
' | |
Finding - Watts Bar - IR 05000390/2009004 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Watts Bar) @ 2009Q3
Self-Identified List (Watts Bar)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||