| Title | Failure to Assess a Non-Conforming Condition for its Impact on Component Operability |
| Description | The inspectors identified a finding of very low safety significance (Green) and associated NCV of 10 CFR 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, when Susquehanna staff did not assess component operability following identification of a potentially non-conforming condition. Specifically, Susquehanna did not assess for operability a potential non-conforming condition associated with inadequate testing of the primary containment airlock inboard equalizing valve which was identified during the review of industry operating experience. Susquehannas corrective actions to restore compliance included entering this issue in their CAP as CR-2015-15187, performing a prompt operability determination of the Unit 1 primary containment airlock inboard equalizing valve, including completion of the requirements in SR 3.0.3 for a missed surveillance, and performing testing on the Unit 2 valve which adequately demonstrated that the PCIV was operable prior to entering into a mode of TS applicability. The inspectors determined that the finding was more than minor because it was associated with the SSC and Barrier performance attribute of the Barrier Integrity cornerstone and adversely affected the cornerstone objective of providing reasonable assurance that the physical design barriers (containment) protect the public from radionuclide releases caused by accidents or events. Specifically, inadequate actions to evaluate the impact of the condition adverse to quality on the operability of the Unit 1 PCIV resulted in a reasonable doubt of operability of the barrier. In accordance with IMC 0609.04, Initial Characterization of Findings, dated June 19, 2012, and Exhibit 2 of IMC 0609, Appendix A, The SDP for Findings At-Power, dated June 19, 2012, the inspectors determined that this finding is of very low safety significance (Green) because the performance deficiency did not represent an actual open pathway in the physical integrity of reactor containment and heat removal components or involve the actual reduction in function of hydrogen igniters in containment. This finding has a cross-cutting aspect in the area of Human Performance, Avoid Complacency, because Susquehanna did not perform a thorough review of the work and planned activity but rather relied on past successes and assumed conditions. Specifically, the control room staff did not assess the condition for operability believing that it was similar to previous CRs documenting a review of operating experience. |
| Site: | Susquehanna |
|---|---|
| Report | IR 05000387/2015002 Section 1R15 |
| Date counted | Jun 30, 2015 (2015Q2) |
| Type: | NCV: Green |
| cornerstone | Barrier Integrity |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.15 |
| Inspectors (proximate) | F Bower H Gray J Greives J Kulp N Graneto T Daun A Turilin B Smith C Graves |
| Violation of: | 10 CFR 50 Appendix B Criterion V Technical Specification Technical Specification - Procedures |
| CCA | H.12, Avoid Complacency |
| INPO aspect | QA.4 |
| ' | |