05000387/FIN-2011002-04
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Failure to Replace Piping on\'B\' CS Chiller |
Description | An NRC-identified, Green NCV of 10 CFR 50, Appendix B, Criterion XVl, Corrective Actions, was identified because FPL failed to correct a condition adverse to quality, an adverse trend of Freon leaks, by identifying that previous work orders (WOs) have not been implemented as required prior to new leaks occurring. Three separate refrigerant leaks were identified that collectively led to the inoperability of the \'B\' CS chiller due to an inability to meet its mission tiine. The leaks occurred on a section of pipe that was prescribed to be replaced as part of the extent of condition review of similar Freon leaks. However, the corrective actions to replace the line were not implemented as planned. PPL entered this issue into their CAP as CR 1387934. The finding was more than minor since it was associated with the equipment performance attribute of the Mitigating systenls cornerstone and affected its objective to ensure the availability, reliability and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the availability and reliability of the control room emergency outside air supply (CREOAS) and CR floor cooling systems was impacted by the \'B\' CS chiller failure. In accordance with IMC 0609, Appendix A, Determining the Significance of Reactor Inspection Findings for At-Power Situations, the finding was determined to be of very low safety significance (Green) because the finding was not a design or qualification deficiency, did not represent a loss of a system/train safety function and did not screen as potentially risk significant due to external events. This finding is related to the cross-cutting area of Pl&R - CAP, because PPL did not thoroughly evaluate problems such that the resolutions address the causes and extent of conditions, to include properly classifying, prioritizing, and evaluating for operability. Specifically, despite four condition reports generated in 2010 that identified adverse trends in Freon leaks or chiller performance issues, PPL failed to appropriately evaluate the trend so as to identify causes, evaluate the effectiveness of past corrective actions, include similar equipment in extent of condition reviews, or identify that the \'B\' CS chiller filter/dryer line was not replaced as planned. (P.1(c)) |
Site: | Susquehanna |
---|---|
Report | IR 05000387/2011002 Section 4OA2 |
Date counted | Mar 31, 2011 (2011Q1) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71152 |
Inspectors (proximate) | E Dipaolo J Furia A Rosebrook P Finney J Tomlinson J Greives D Molteni |
CCA | P.2, Evaluation |
INPO aspect | PI.2 |
' | |
Finding - Susquehanna - IR 05000387/2011002 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Susquehanna) @ 2011Q1
Self-Identified List (Susquehanna)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||