05000382/FIN-2014008-01
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Inadequate Procedures for Securing Dry Cooling Tower Fans |
| Description | A self-revealing non-cited violation of 10 CFR Part 50, Appendix B, Criterion III occurred when the licensee did not assure that design basis information was translated into specifications, drawings, procedures, and instructions. Specifically, after a failure revealed new design basis information regarding the need to place a train of dry cooling tower fan controllers to the off position prior to de-energizing the associated control cabinet, the licensee failed to incorporate this information into procedures. As a result, the failure recurred. The licensee entered this condition into its corrective action program as Condition Reports CR-WF3-2012-05680 and -06908 and updated procedure OP-006-005, Inverters and Distribution, to incorporate the new design basis information into procedures. The licensee documented its failure to timely update design basis information in Condition Report CR-WF3-2014-02981. The failure to assure that design basis information was translated into specifications, drawings, procedures, and instructions as required by 10 CFR Part 50, Appendix B, Criterion III was a performance deficiency. The performance deficiency was more than minor because it was associated with the equipment performance attribute of the Mitigating Systems Cornerstone and adversely affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the failure to incorporate design basis information regarding the need to place the dry cooling tower fan controllers to the off position prior to de-energizing the associated control cabinet into specifications, drawings, procedures, and instructions impacted the capability, availability, and reliability of both trains of dry cooling towers. Using NRC Inspection Manual Chapter 0609, Appendix G, Shutdown Operations Significance Determination Process, the inspectors determined the finding to be of very low safety significance (Green) because the required number of dry cooling towers in the protected train maintained their operability. This finding has a resolution cross-cutting aspect in the problem identification and resolution cross-cutting area because the licensee had not taken effective corrective actions to address an issue in a timely manner commensurate with its safety significance. |
| Site: | Waterford |
|---|---|
| Report | IR 05000382/2014008 Section 4OA2 |
| Date counted | Jun 30, 2014 (2014Q2) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | Self-revealing |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | G Miller P Jayroe S Crane A Sanchez C Speer E Ruesch |
| Violation of: | 10 CFR 50 Appendix B Criterion III, Design Control |
| CCA | P.3, Resolution |
| INPO aspect | PI.3 |
| ' | |
Finding - Waterford - IR 05000382/2014008 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Waterford) @ 2014Q2
Self-Identified List (Waterford)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||