Finding | |
---|---|
Title | Inadequate 10 CFR 50.59 Evaluation for Jet Pump Plugs Affecting Fuel Bundle Cooling |
Description | The inspectors identified a Severity Level IV NCV of Title 10 of the Code of Federal Regulations (10 CFR) 50.59, Changes, Tests, and Experiments, having very low safety significance (Green), for the licensees failure to provide a written safety evaluation supporting the determination that a license amendment was not required for operation with jet pump seal plugs (lost in the reactor vessel in February 2015 during a refueling outage) that could negatively impact fuel bundle cooling during an anticipated operational occurrence (misplaced fuel bundle). The licensee entered this issue into the corrective action program (CAP) as action report (AR) 02486215 and considered the core operable because additional testing demonstrated that with sufficient time (approximately 11 days) at operating temperature, the rubber plugs would degrade and pass through the affected flow orifices. The finding was determined to be more than minor because the inspectors could not reasonably determine that the activity, to operate with jet pump plugs blocking peripheral fuel bundle flow, would not have required prior NRC approval. Specifically, if the licensee operated a peripheral blocked fuel bundle coincident with a misplaced fuel bundle, the minimum critical power ratio limits/margins may not have been assured. Additionally, this finding was more than minor because the underlying technical issue adversely affected the Barrier Integrity Cornerstone objective of design control and cladding performance. The finding involves the potential for a misplaced fuel bundle concurrent with complete flow blockage to a fuel assembly. Given standard refueling practices, an error that results in plant operation with a misplaced fuel bundle is very unlikely due to strict procedural controls and multiple verifications of fuel assembly placement. In addition, the misplaced fuel assembly would have to be located at a peripheral core location to be susceptible to a jet pump plug that could possibly block bundle cooling and this was very unlikely. Further, the inspectors considered the relatively short duration of time where the plug material parameters were sufficient to cause plugging of an orifice coincident with plant power levels that could challenge the fuel integrity limits. Given these factors, the inspectors determined that the likelihood of a misplaced fuel assembly combined with a blocked orifice that could result in fuel clad damage was very low. Given the very low likelihood of the event scenario to occur and the low consequences if it were to occur, the inspectors concluded that the finding was of very low safety significance (Green). The inspectors identified a cross-cutting aspect associated with this finding in the area of Human Performance, Conservative Bias, because the licensee staff did not use a decision-making practice that emphasized prudent choices over those that are simply allowable (H.14). |
Site: | LaSalle ![]() |
---|---|
Report | IR 05000374/2015002 Section 1R18 |
Date counted | Jun 30, 2015 (2015Q2) |
Type: | TEV: Severity level IV |
cornerstone | Barrier Integrity |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.18 |
Inspectors (proximate) | A Dunlop C Hunt D Chyu D Krause J Robbins M Holmberg M Kunowski R Ruiz R Zuffa |
Violation of: | 10 CFR 50.59 |
CCA | H.14, Conservative Bias |
INPO aspect | DM.2 |
' | |
Finding - LaSalle - IR 05000374/2015002 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (LaSalle) @ 2015Q2
Self-Identified List (LaSalle)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||